Digital pressure balance Model CPD8000

Similar documents
Precision hand-held pressure indicator Model CPH6400

Precision high-pressure controller Model CPC8000-H

Pneumatic high-pressure controller Model CPC7000

High-end pressure controller Model CPC8000

Digital dead-weight tester Model CPD8500

Pneumatic high-pressure controller Model CPC7000

Intrinsically safe hand-held pressure indicator (Ex version) Model CPH62I0-S1 (1-channel version) Model CPH62I0-S2 (2-channel version)

Precision pressure indicator Model CPG2500

Digital deadweight tester Model CPD8500

Dead-weight tester High-pressure version Model CPB3800HP

Precision digital pressure gauge Model CPG1000

Hand-held pressure calibrator with integrated pump Model CPH6600

Primary standard differential pressure balance Model CPB6000DP

Precision pressure sensor Basic version Model CPT6020

Hydraulic pressure balance Model CPB5800

DPG10G DIGITAL PRIMARY STANDARD METROLOGICAL RANGE. SEVERAL RANGES UP TO 50 MPa GAUGE POSITIVE OR NEGATIVE PRESSURE

Pneumatic dead-weight tester Model CPB3500

Digital pressure gauge Model CPG500

Pneumatic service kit Model CPG-KITP

Industrial pressure controller Model CPC4000

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

FPG8601 Force Balanced Piston Gauge

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

High-speed pressure sensor Model CPT6140

Industrial pressure controller Model CPC4000

Hydraulic hand test pump Models CPP700-H and CPP1000-H

Primary standard pressure balance Series CPB6000

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Absolute Digital Piston Gauge

High-performance submersible pressure transmitter For level measurement Model LH-20

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Digital pressure gauge Model CPG500

Gas density monitor With integrated transmitter Model GDM-100-TI

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

High-performance submersible pressure transmitter For level measurement Model LH-20

Digital Piston Standard

PG9607 Piston Gauge. Automated primary pressure reference for absolute and gauge pressures to 500 kpa

Series Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features

Deadweight Tester / Pressure Balance High pressure up to 5,000 bar / 70,000 psi CPB5000-HP. Applications. Special features. Description. Rel.

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Series 7250 Ruska High-Speed Digital Pressure Controller. GE Sensing. Features

High-performance submersible pressure transmitter For level measurement Model LH-20

Modular pressure controller Model CPC6050

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Bourdon tube pressure gauge, stainless steel For extremely low ambient temperatures down to -70 C Model PG23LT, with case filling

7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications

Differential pressure gauge For the process industry Model , all-metal media chamber

PPC4E Pressure Controller/Calibrator Superior rangeability and reliability

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators Selection Guide

Submersible pressure sensor High-performance Model LH-20

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators

High-performance submersible pressure transmitter For level measurement Model LH-10

159 mm 154 mm. Subject to changes 10/2012

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

HumiSys HF High Flow RH Generator

Automatic Isokinetic Sampler. ST5 Evo

Additel 780 Series Pressure Controller

628 Differential Pressure Decay Leak Tester

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

Pressure transmitter PASCAL Ci4

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Pneumatic High-Speed Pressure Controller Model CPC3000

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Pressure calibration. 20

[Instruments for vacuum measurement, checking and adjustment] 3

Mass Flow Controller (MFC) for Gases

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Digital Pressure Gauge Main features: Data Sheet: BIT02B.417.R6.EN COVER on request

Additel 780 Series Pressure Controller

How to specify a product. Process Sensors and Mechanical Instruments

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

ADT 761 Automated Pressure Calibrator

PRODUCT CATALOGUE DIGITAL GAUGES

Pressure Calibrators. Series PC..., PM...

Automatic Isokinetic Sampler. ST5 Evo

Digital pressure gauges

Mass Flow Controller (MFC) for Gases

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Product review. Calibration technology

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Additel 780 Series Pressure Controller

Calibration Technology

Mass Flow Meter (MFM) for Gases

Automated Mass Handling for High Performance Pressure Balances

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Code Basic module and level control complete with optionals code

P3000 Deadweight Tester Setup, Part 1: Limited Partial Correction Method

Sartorius CCL kg Prototype Mass Comparator

Transcription:

Calibration technology Digital pressure balance Model CPD8000 WIKA data sheet CT 32.04 for further approvals see page 7 Applications High-level digital primary standard Reference instrument for calibration laboratories and high-end sensor production for the testing, adjustment and calibration of pressure measuring instruments Complete, stand-alone system, also suitable for on-site use Special features Absolute and gauge pressure Unique working principle 15 measuring ranges up to 50 MPa Total measurement uncertainty down to 20 ppm of reading Ideal for automatic calibration systems Model CPD8000-AL digital pressure balance, fitted with low-pressure measuring head Description Reference primary standards Pressure balances are high-precision fundamental pressure standards that define the derived unit of pressure directly from the fundamental units of mass, length and time following the formula p = F/A. The model CPD8000 digital pressure balance is a worldwide exclusivity combining two high-level technologies: High-end piston-cylinder systems, whose effective area (A) converts the pressure into the respective force. High-accuracy force cell which measures the force F. CPD8000 is defined as a digital pressure balance and is thus a high-precision pressure measurement standard. Functionality The CPD8000 measuring concept is a primary principle. It combines the measurement uncertainty and reliability of fundamental pressure standards with the ease of use of automatic digital pressure measuring instruments. Easy to use The model CPD8000 offers the same high measurement uncertainty as a high-end pressure primary standard with the benefits of: Mass load not necessary Built-in reference mass for auto calibration Displaying and digital transmission of fully corrected reference pressure WIKA data sheet CT 32.04 01/2018 Page 1 of 13 Data sheets showing similar products: Primary-standard pressure balance; series CPB6000; see data sheet CT 32.01 Primary-standard differential pressure balance; model CPB6000DP; see data sheet CT 32.02 Automatic pressure balance; model CPB8000; see data sheet CT 32.03 CalibratorUnit; models CPU6000-W, CPU6000-S, CPU6000-M; see data sheet CT 35.02 Calibration software; model WIKA-Cal; see data sheet CT 95.10

The working principle The pressure is applied on the effective area of the piston and turned into a proportional force. The force is transferred to the measuring-force cell. The measuring-force cell continously measures and calculates the pressure-generated force. A microprocessor converts the measured force to the measurement parameter pressure and corrects the environmental influences. Pressure p Effective area A p = F A Force F Model CPD8000 basic principle Gauge and absolute pressure The model CPD8000 is available in two versions: CPD8000-GH (gauge pressure) Available measuring ranges up to 500 bar (5.000 psi oder 50 MPa) with atmospheric pressure reference. CPD8000-AL and CPD8000-AH (gauge and absolute pressure) Available measuring ranges up to 20 bar (2 MPa) in gauge mode and absolute pressure. The installation of a measuring-force cell in a vacuum-sealed reference pressure chamber enables operation in gauge and absolute pressure mode. Continuous measuring process in absolute pressue is possible without interruption contrary to classic absolute pressure balances, where the reference vacuum has to be interrupted with each pressure change. Model CPD8000-GH The measurement is placed under a reference vacuum chamber. Absolute pressure measurement is a simple and fast solution. It is capable to operate in an absolute pressure mode without interrupting the vacuum between each pressure point, as it is with the classical pressure balances. Model CPD8000-AL or CPD8000-AH Page 2 of 13 WIKA data sheet CT 32.04 01/2018

General assembly CPD8000's measurement quality and long-term performance are based on five key concepts. Piston-cylinder measuring system Key element The role of the piston-cylinder system is to precisely convert the pressure into force. The quality of this transformation is due to its excellent geometry and very low sensitivity to external disturbances. The Desgranges & Huot s piston-cylinder systems (PCUs) are manufactured in a special grade of tungsten carbide, which has been perfected for more than 50 years. The manufacturing tolerances are typically below 0.1 µm, promoting best possible sensitivity, linearity and repeatability. Tungsten carbide has the advantage of minimal distortion under pressure and temperature. Therefore, the pistoncylinder system maintains the metrological qualities regardless of the operating conditions. A large choice of pressure ranges Desgranges & Huot manufactures 21 different piston-cylinder systems (6 for the CPD8000-AL/-AH, 15 for the CPD8000- GH). For easier handling and assignment, the effective area of the piston-cylinder systems are dimensioned with a nominal conversion factor (Kn). The auto-calibrating function (ACF) The CPD8000 force cell response may drift with time. This drift is a result of the change in the environmental parameters ambient temperature, relative humidity and atmospheric pressure. The measuring-force cell is associated with an auto-calibrating function which, whenever necessary, enables easy application of a reference mass (F = M x g) for recalibration purposes while the measuring head is connected. Optionally a set of external standard masses can be used for linearisation of the measuring-force cell. 1 1 4 3 The measuring head A comfortable unit The measuring head contains the piston-cylinder systems. Trouble-free force transmission from the rotating piston to the measuring-force cell is ensured by the coupled drive system. It is equipped with a 4-wire platinum resistance thermometer allowing for the necessary temperature measurement. The coupling of the measuring head with the force cell allows for simple and fast exchange of the measuring heads. The measuring cell A force-transferring function The electronic measuring-force cell has been developed for the highly accurate production of mass comparators. It uses the MONOBLOC technology manufactured by electro erosion. This technology reflects the latest innovations realised in mechanics, electronics, computer science and opto-electronics, hence eliminating operations that require comprehensive maintenance. Basic principle of the auto-calibrating function (ACF) 1 Measuring-force cell 2 Internal standard mass 3 Computer connection 4 EMM sensors The environment monitoring module (EMM) In order to determine whether it is necessary to use the ACF, the CPD8000 is equipped with an environment monitoring module which consists of three sensors for ambient temperature, relative humidity and barometric pressure. After the calibration, the EMM keeps on monitoring the evolution of the ambient conditions in real time. If these conditions vary in proportions that might noticeably affect the measuring accuracy, the CPD8000 displays a warning flag. The user s attention is drawn to the fact that the ACF has to be activated in order to readjust the measuring instrument to the new operating conditions. The warning is also sent to the command software if the CPD8000 is operated from a remote computer. WIKA data sheet CT 32.04 01/2018 Page 3 of 13

Displayed pressure calculation The pressure displayed by the CPD8000 is calculated according to the following formula: P = Kn x N x g l x (1 - ( λ PC x P )) x (1 - α PC x ( t - 20 )) x ( ρ αc - ρ m ) + P Vαc N k g n ρ αn - ρ m Legend: Kn Specific coefficient of the piston-cylinder system N Indication of the measuring-force cell in count N k Sensitivity of the measuring-force cell g l Local gravitational acceleration in m/s² g n Normal gravitational acceleration in m/s² λ PC Pressure-distortion coefficient of the piston-cylinder system α PC Thermal-dilation coefficient of the piston-cylinder system t Temperature of the piston-cylinder system in C ρ ac Air density during the adjustment of the measuringforce cell in kg m -3. This parameter is null when the CPD8000-A operates in absolute mode. ρ m Density of the adjustment mass in kg m -3 ρ an Normal air density in kg m -3 P Vac Residual gas pressure in the vacuum chamber Variable parameters The variable parameters affecting the calculation of the pressure are automatically measured and integrated in the expression of the pressure: Temperature of the piston-cylinder system (t) Ambient temperature 1) Humidity 1) Atmospheric pressure 1) Residual vacuum (P Vide ) 1) Defining the air density during the calibration (ρ αc ) The pressure is automatically converted into any of the common pressure units and the user has the possibility to configure the system to special units. This rigorous metrology enables an ease of use as well as speed of measurement operation. Display of the model CPD8000 Constant parameters The constant parameters entering in the computing of pressure are stored in the memory of the CPD8000: Kn of the piston-cylinder system Sensitivity of the measuring-force cell (N k ) Normal gravitational acceleration (g n ) Local gravitational acceleration (g l ) Pressure-distortion coefficient of the piston-cylinder system (λ PC ) Thermal dilation coefficient of the piston-cylinder system (α PC ) Density of the calibration mass (ρ m ) Normal air density (ρ an ) Some of these parameters are specific to each pistoncylinder system and are determined during the calibration. You can easily modify them if necessary. The parameters of six different piston-cylinder systems can be stored. Page 4 of 13 WIKA data sheet CT 32.04 01/2018

Measuring ranges The pressure measuring ranges of the CPD8000 depend on the specific coefficient (Kn) of the piston-cylinder systems with which the measuring head is equipped. The CPD8000 can be used with various measuring heads. Measuring Pressure ranges Resolution Measurement uncertainty 1) Piston-cylinder Usable head Standard Premium system Kn medium Absolute and gauge pressure with model CPD8000-AL and CPD8000-AH A01 0.001 mbar... 1 bar 0.001 mbar 0.005 % 0.0025 % 0.1 bar/kg Pure gas A02 0.002 mbar... 2 bar 0.002 mbar 0.005 % 0.0025 % 0.2 bar/kg Pure gas A03 0.005 mbar... 5 bar 0.005 mbar 0.005 % 0.0025 % 0.5 bar/kg Pure gas A04 0.01 mbar... 10 bar 0.01 mbar 0.005 % 0.0025 % 1 bar/kg Pure gas A05 0.02 mbar... 20 bar 0.02 mbar 0.005 % 0.0025 % 2 bar/kg Pure gas Gauge pressure with model CPD8000-GH G01 0.001 mbar... 1 bar 0.001 mbar 0.005 % 0.0025 % 0.1 bar/kg Pure gas G02 0.002 mbar... 2 bar 0.002 mbar 0.005 % 0.0025 % 0.2 bar/kg Pure gas G03 0.005 mbar... 5 bar 0.005 mbar 0.005 % 0.0025 % 0.5 bar/kg Pure gas G04 0.01 mbar... 10 bar 0.01 mbar 0.005 % 0.0025 % 1 bar/kg Lubricated gas G05 0.02 mbar... 20 bar 0.02 mbar 0.005 % 0.0025 % 2 bar/kg Lubricated gas G06 0.05 mbar... 50 bar 0.05 mbar 0.005 % 0.0025 % 5 bar/kg Lubricated gas G07 0.1 mbar... 100 bar 0.1 mbar 0.005 % 0.0025 % 10 bar/kg Lubricated gas G08 0.2 mbar... 200 bar 0.2 mbar 0.005 % 0.003 % 20 bar/kg Lubricated gas G09 0.5 mbar... 500 bar 0.5 mbar 0.005 % 0.0035 % 50 bar/kg Lubricated gas G20 0.0002... 200 psi 0.0002 psi 0.005 % 0.0025 % 20 psi/kg Lubricated gas G21 0.0005... 500 psi 0.0005 psi 0.005 % 0.0025 % 50 psi/kg Lubricated gas G22 0.001... 1,000 psi 0.001 psi 0.005 % 0.0025 % 100 psi/kg Lubricated gas G23 0.0025... 2,500 psi 0.0025 psi 0.005 % 0.003 % 250 psi/kg Lubricated gas G24 0.003... 3,000 psi 0.003 psi 0.005 % 0.003 % 300 psi/kg Lubricated gas G25 0.005... 5,000 psi 0.005 psi 0.005 % 0.003 % 500 psi/kg Lubricated gas 1) The total measurement uncertainty is defined as the uncertainty in measurement attributed via the reference standard uncertainty, influence of environmental conditions, resolution of the instrument, repeatability and hysteresis characteristics during the measurement with the coverage factor (k = 2). Other pressure ranges on request. WIKA data sheet CT 32.04 01/2018 Page 5 of 13

Specifications Model CPD8000 Piston-cylinder system Material Poisson's ratio 0.218 Young's modulus Typical geometry researched Straightness Roundness Parallelism Clearance between the piston and the cylinder Stability of the effective area Tungsten carbide 6 10 11 N/m 0.1 µm (typical manufacturing tolerance) 0.1 µm (typical manufacturing tolerance) 0.1 µm (typical manufacturing tolerance) 0.2... 0.4 µm according to the model 1 ppm/year Standard masses Internal masses Material 304L non-magnetic stainless steel Mass density 7,900 kg/m³ ±10 % External optional calibration masses Material 304L non-magnetic stainless steel Mass density 7,920 kg/m³ ±10 % Composition of the set 5 x 2 kg (5 x 4.4 lbs) Base instrument Case Dimension (L x W x H) Weight Display Screen Indication Front foil Sensor specifications Maximum overpressure Pressure transmission medium Voltage supply Power supply Power consumption 530 x 400 x 320 mm (20.87 x 15.75 x 12.60 in) 20 kg (44.1 lbs) LC display back-lighting graphic screen with contrast setting Pressure display in 12 pressure units and a user unit EMM parameter display Permanent display of the residual gas pressure TARE button CAL button, automatic calibration function (ACF) 110 % FS Clean, dry, non-corrosive gases AC 110... 240 V, 50/60 Hz 60... 80 VA Environmental measuring module (EMM) Sensor type Accuracy Alarm setting Ambient temperature 4-wire Pt100 ±0.2 C ±2 C Relative humidity Capacitive sensor ±5 % r. h. ±20 % r. h. Atmospheric pressure Strain sensor ±2 mbar ±10 mbar PCA temperature DIN 43760 4-wire Pt100 ±0.1 C N/A Residual vacuum Pirani gauge 1 Pa ±1 E -4 Page 6 of 13 WIKA data sheet CT 32.04 01/2018

Base instrument Researched metrological specifications Linearity Hysteresis Repeatability Temperature effect Measurement uncertainty Permissible ambient conditions Operating temperature Relative humidity Communication Interface Sampling rate 2 E -6 FS 2 E -6 FS 5 E -6 FS Full compensation down to 25 ppm of reading, depending on the measuring range 18... 28 C (64... 82 F) 15... 85 % r. h. (non-condensing) RS-232-C 100 ms Approvals Logo Description Country EU declaration of conformity EMC directive EN 61326 emission (group 1, class B) and immunity (electrical equipment for measurement, control and laboratory use) Low voltage directive RoHS-directive European Union EAC Electromagnetic compatibility Low voltage directive KazInMetr Metrology, measurement technology - MTSCHS Permission for commissioning Eurasian Economic Community Kazakhstan Kazakhstan Certificates Certificate Calibration Recommended recalibration interval Standard: COFRAC calibration certificate Option: LNE/PTB calibration certificate 3 to 5 years (dependent on conditions of use) Approvals and certificates, see website WIKA data sheet CT 32.04 01/2018 Page 7 of 13

Dimensions in mm Model CPD8000-AL and CPD8000-AH Side view (left) Rear view 1 312 (12,28) 63 (2,48) 148 (5,83) 30 (1,18) 2 63 (2,48) 23 (0,91) 35 (1,38) 137 (5,39) 110 (4,33) 22 (0,87) 432 (17,01) Ø 12 (0,47) 5 6 7 9 8 10 Top view Front view 3 4 11 174 (6,85) 21 (0,83) 150 (5,91) 130 (5,12) 73 (2,87) 360 (14,17) Ø 19 (0,75) Ø 30 (1,18) 89 (3,50) 194 (7,64) 316 (12,44) 158 (6,22) 25 (0,98) 526 (20,71) 1 Measuring head 2 Measuring cell 3 Levels 4 Digital display 5 Levelling feet 6 COM port to PC 7 Connection port for motor and platinum resistance thermometer (PRT) 8 Mains supply 9 Connection for gas lubrication (for AH version) 10 Reference vacuum connections 11 Connection flange to the test item Page 8 of 13 WIKA data sheet CT 32.04 01/2018

Model CPD8000-GH Side view (left) Rear view Ø 110 (4,33) 170 (6,69) 130 (4,12) 63 ( 2,48) 65 (2,56) 1 2 106 (4,17) 105 (4,13) 5 6 7 8 Top view Front view 3 4 296 (11,65) 130 (5,12) 125 (4,92) 444 (17,48) 252 (9,92) 126 (4,96) 1 Measuring head 2 Measuring cell 3 Levels 4 Digital display 5 Levelling feet 6 COM port to PC 7 Connection port for motor and platinum resistance thermometer (PRT) 8 Mains supply WIKA data sheet CT 32.04 01/2018 Page 9 of 13

Remote control All of the CPD8000 functions, even the ACF running command, can be executed from an external computer through serial interface (RS-232-C), which enables it to be integrated in an automatic calibrating system. Maintenance The CPD8000 is delivered with the operating instructions, accessories and tools allowing its general maintenance. No other maintenance is necessary if the standard is used in accordance with the routine instructions described in the operating instructions. Recalibration is recommended every five years depending on the operating conditions. Calibration All CPD8000 are delivered with a gauge COFRAC calibration certificate by Degranges & Huot. The COFRAC calibration guarantees the traceability of the measurements done by the CPD8000 to the national and international standards, and it takes into account: The Kn specific coefficient determination The automatic calibration function (ACF) The uncertainty calculation presented in the certificate respects the ISO TAG4 and EAL recommendations and shows the enlarged measurement uncertainty of the CPD8000 with a coverage factor k = 2. Summary of the functions The CPD8000 has a great variety of functions aimed at facilitating its use and assuring the quality of its long-term operation: Menus in English, French, German and Spanish Saving of the metrological characteristics for 6 pressure ranges Overpressure visual and sound warning Mechanical protection against overpressure up to 110 % User-adjustable pressure stability criterion Choice between internal/external calibration Visual warning when the calibration of the force cell is necessary Temperature measurement at the piston-cylinder system with a platinum resistance thermometer (PRT) Auto-calibrating function (ACF) including the acquisition and correction calculation of the environment parameters (EEM) It takes into account the CPD8000 s intrinsic measuring deviations, the uncertainty of the reference standards as well as the influence of the ambient conditions. Option By using a special adaptation kit, it is possible to use the measuring head of model CPD8000-GH with the CPD8000- AL/-AH. These heads can be used to work only in gauge mode but allow extending the range capability of the CPD8000-A up to 500 bar (50 MPa). Conclusion Due to the design and performance, the model CPD8000 digital pressure balance is unique in the world. The operations with the balance do not necessitate a bell to create the vacuum and masses load. Connected to an automatic controller (CPC6000 or CPC8000), the CPD8000 enables performing fast calibrations, without having to break the vacuum between each pressure point, with a high metrological reliability. These instruments are used by national laboratories, calibration labs, meteorology, the R&D laboratories, sensor manufacturers and aerospace or avoinic companies. Page 10 of 13 WIKA data sheet CT 32.04 01/2018

Further pressure balances within our calibration technology programme Primary-standard pressure balance, model CPB6000 Measuring ranges: Pneumatic up to 1,000 bar (14,500 psi) Hydraulic up to 5,000 bar (72,520 psi) Measurement down to 0.002 % of reading, depending uncertainty: on model For specifications see data sheet CT 32.01 Primary-standard pressure balance, series CPB6000 Primary-standard differential pressure balance, model CPB6000DP Measuring range = (static pressure + differential pressure): Pneumatic up to 800 bar (11,600 psi) Measurement uncertainty: 0.005 % of reading up to 0.002 % of reading (optional) For specifications see data sheet CT 32.02 Primary-standard differential pressure balance, model CPB6000DP Automatic pressure balance, model CPB8000 Measuring ranges: Pneumatic up to 1.000 bar (14.500 psi) Hydraulic up to 5.000 bar (72.520 psi) Measurement 0.005 % of reading uncertainty: up to 0.003 % of reading (optional) For specifications see data sheet CT 32.03 Automatic pressure balance, model CPB8000 WIKA data sheet CT 32.04 01/2018 Page 11 of 13

WIKA-Cal calibration software Easy and fast creation of a high-quality calibration certificate The WIKA-Cal calibration software is used for generating calibration certificates or logger protocols for pressure measuring instruments and is available as a demo version for a cost-free download. A template helps the user and guides him through the creation process of a document. In order to switch from the demo version to a full version of the respective template, a USB key with the template has to be purchased. The pre-installed demo version automatically changes to the selected full version when the USB key is inserted and is available as long as the USB key is connected to the computer. Creation of calibration certificates for mechanical and electronic pressure measuring instruments A calibration assistant guides you through the calibration Automatic generation of the calibration steps Generation of 3.1 certificates per DIN EN 10204 Creation of logger protocols User-friendly interface Languages: German, English, Italian and more due with software updates For further information see data sheet CT 95.10 Calibration certificates can be created with the Cal-Template and logger protocols can be created with the Log-Template. Cal Demo Generation of calibration certificates limited to 2 measuring points, with automatic initiation of pressures via a pressure controller. Calibration certificate Calibration certificate Kalibrierzeugnis Kalibrierzeugnis Certificate No. 00000122 Zeugnis-Nr. General Device under test (DUT) Allgemein Calibration certificate Elektrisches Druckmessgerät Customer Demo customer Demo street DE-12345 Demo city Kunde Customer order No. Kundenbestellnummer Order date Model Date of calibration 01/02/2017 Operator Demo User Datum der Kalibrierung Bearbeiter Typ Serial number demo1234 (0... 10) bar g Accuracy 0.05 % FS Genauigkeit Resolution (scale division) 0.0001 bar Measuring point No. demo tag Auflösung (Skalenwert) Messstellen-Nr Reference value WS Reading DUT bar bar Referenzwert GN D-10 Scale range Seriennummer Anzeigebereich Bestelldatum Certificate No. 00000122 Messergebnisse Electrical gauge Kalibrierschein Zeugnis-Nr. Measurement results Kalibriergegenstand (KG) 0.00000 10.00000 Ablesung KG 0.0000 10.0010 0.0010 10.0020 Statement of compliance Konformitätsaussage Object keeps the specifications! Der Kalibriergegenstand hält die Herstellerspezifikationen ein! Environmental conditions Cal Light Generation of calibration certificates with no limitations on measuring points, without automatic initiation of pressures via a pressure controller. Place of calibration Umgebungsbedingungen Temperature Ort der Kalibrierung (20,0 ± 0,1) C Temperatur Atmospheric pressure (1013,0 ± 0,1) hpa Rel. humidity (40 ± 1) % Atmosphärischer Luftdruck Rel. Luftfeuchte Demo place Musterort g = (9.80946 ± 0.01) m/s² Measurement conditions Messbedingungen Working standard (WS) Pressure controller Gebrauchsnormal (GN) Druckcontroller Model Demo CPC Calibration mark Demo 12345 Typ Kalibrierzeichen Scale range (0... 10) bar g Accuracy 0.02 % FS Anzeigebereich Genauigkeit Demo laboratory Demo street 123 12345 Demo city Demo country Tel.: 01234/56789 Fax: 01234/56789 E-Mail: demo@demo.com www.demo.com Page Seite 1/2 Demo laboratory Demo street 123 12345 Demo city Demo country Tel.: 01234/56789 Fax: 01234/56789 E-Mail: demo@demo.com www.demo.com Page Seite 2/2 Log Demo Creation of data logger test reports, limited to 5 measured values. Log Creation of data logger test reports without limiting the measured values. Page 12 of 13 WIKA data sheet CT 32.04 01/2018

Scope of delivery Digital pressure balance, model CPD8000 incl. transport case Measuring head Pt100 probe Cover for measuring head and measuring cell Power cord RS-232 interface cable Set of accessories for standard operation of the CPD8000 Operating instructions COFRAC calibration certificate Options Premium uncertainty incl. LNE/PTB calibration certificate Ordering information Model / Base / Head with piston-cylinder system / Calibration for piston effective area gauge / Calibration for piston effective area absolut / Mass set / Motor controller / Vacuum pump / Additional approvals / Additional order information 05/2014 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 01/2018 EN WIKA data sheet CT 32.04 01/2018 Page 13 of 13 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de