Title of Manual: Specimen Collection Document Number: GPA.SPC To provide the proper collection protocol for Trichomonas Vaginalis testing.

Similar documents
Title of Manual: Specimen Collection Document Number: GPA To provide the proper collection protocol for Candida Vaginitis testing.

Title of Manual: Specimen Collection Document Number: GPA.SPC.45.0

TEV-TROPIN [somatropin (rdna origin) for injection] 5 mg & 10 mg

RayBio Human vwf ELISA Kit

Department of Laboratories St. Louis, MO ISSUE DATE: June 2007 REVISION DATE: July 2010 REVIEWED DATE: May 2017 PRINCIPILE:

HemoCue Hb Procedure Template

Exeter Clinical and Health Research

Standard. Standard. Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00332

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Blue Thumb Test Procedures

MOLEBIO LAB #1: Microquantity Measurement

COLLECTION OF BLOOD. Types of patients

Pipetting and Determining Protein Concentration

M.M.C. International B.V.

Specimen Collection Procedures

PREPARING GAS SAMPLES IN LARGE PLASTIC SYRINGES

RayBio Human TNF-alpha ELISA Kit

Measuring Mass and Volume

PERFORMANCE OF A FINGERSTICK

University of New Haven DEPARTMENT OF CHEMISTRY and CHEMICAL ENGINEERING

Cryogenic Materials Operating Procedure and Safety Requirements

Unblocking the MicroSprayer Aerosolizer Model IA-1C With the High Pressure Reverse Cleaning Adapter. Instructions for Use

VAPOMATIC ANESTHETIC VAPORIZER

Unblocking the MicroSprayer Aerosolizer Model IA-1B With the High Pressure Reverse Cleaning Adapter. Instructions for Use

Laboratory #2 Pipetting Technique and Micropipette Calibration Skills=40 pts

Skills & Scenarios 81

Standard. Bag & Stand Advanced Venepuncture Arm. Light. Part No: Brown. Part No: Black. Part No: 00442

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Cleaning rod: spring steel, stainless steel or carbon fibre cleaning rod - only use a one-piece rod. Avoid using snakes.

Multiplate Platelet Function Analyzer: An Overview

RECOMBINATE. [Antihemophilic Factor (Recombinant)] (For intravenous use only)

MCHS-Mankato Cytology. Cytology Specimens

Biochemistry Laboratory I CHEM 4401 Pipetting & Scales

limbsandthings.com Advanced Venepuncture Arm User Guide For more skills training products visit Limbs & Things Ltd.

Instruction Manual Updated 5/26/2009 Ver. 2.0

Basic Flows in a Microfluidic Device

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Natural Reaction Boosters C. V. Krishnan

INJECTABLE TRAINING ARM

Skills & Scenarios 81

Standard Operating Procedures (v9 5/1/17)

Ti-Pure TITANIUM DIOXIDE DETERMINATION OF SLURRY RHEOLOGY METHOD: T WP

ab IgG1 Human ELISA Kit

RayBio Human IFN alpha/beta R2 ELISA Kit

Emulsiflex C3 Homogenizer Protocol

Aseptic Techniques. Techniques for Sterile Compounding. Pharmacy Technician Training Systems Passassured, LLC

Laboratory Chemical Hygiene Plan

Laboratory Standard Operating Procedure: Specimen Preservatives

1.0 PURPOSE The purpose of this procedure is to describe the use of basic aseptic technique.

CHILD INJECTABLE TRAINING ARM INSTRUCTIONS FOR INSTALLING LF03629U REPLACEMENT SKIN ON IV ARM LF03612U

Page: Page 1 of 6 Author: Dylan Lennon MAL Director: Dr. Peggy Borum FSHN Chair: Dr. Neil Shay

Proficiency Testing Corrective Action Checklist: PT PROVIDER: PT EVENT: TEST:

Techcon Systems TS1258 Pressure Pot

Tools to Enhance Laboratory Biosafety and Biosecurity Performing Risk Assessments

Techcon Systems TS1254 Pressure Pot

An Inuit Yo-Yo Sandra J. Walton

Chester Chest Model 2400 User s Manual

Chester Chest Model 2400 User s Manual

Material Safety Data Sheet

UNCC Biotechnology and Bioinformatics Camp. Dr. Jennifer Weller Summer 2010

Operating Instructions

TJF-Q180V Cleaning and Disinfection Checklist

Any laboratory is equipped with specific tools, equipment,

Safety In the Science Lab

MULTICHANNEL. Labnet International, Inc.

1. If grams of the vapor of a volatile liquid can fill a 498 ml flask at o C and 775 mm Hg, what is the molecular mass of the gas?

Hammar LifeJacket Inflator

Safety Huber Needles

Installation of Your SprayMaster System

Hydrofluoric Acid. Syracuse University Laboratory Standard Operating Procedure. I. Purpose: Physical and Chemical Properties: Potential Hazards:

RG1200 Service and Repair Manual

Aerobic Respiration. Evaluation copy

VOLUMETRIC TECHNIQUES

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Laboratory Standard Operating Procedure: Irritants

Standard Operating Procedures (v5 5/1/17)

PRODUCT SHEET. Order probe only as RXPROBE02

Experiment 1 Use of Micropipettes: measuring volume accurately

Pipetting Small Volumes

Laboratory Standard Operating Procedure: Sensitizers

Part A: 20 minutes plus 30 minutes setting time Part B: day 1, 20 minutes; then 5 minutes each day for about 5 days

Roy G. Biv Charles W. McLaughlin

Behavior of the Simple Pendulum

biosensis Mouse CXCL10/IP-10 ELISA Kit Protocol

Laboratory Safety Training. Environmental Health and Safety

of Carbon Dioxide (CO 2

CHEMISTRY FACULTY LABORATORY SAFETY CONTRACT CENTRAL CAMPUS

MODEL 1329 Tank Gauge

For accurate measurements and to prevent damage to the micropipets, follow these important guidelines:

Blood Sampling: Arterial Lines

Assisting with Insertion. Care of Intraspinal Catheters

Under Basin Storage Unit

SCIENCE EXPERIMENTS ON FILE Revised Edition Tornado Model. Safety Please click on the safety icon to view safety precautions.

Tissue-Plus. User Manual. O.C.T. Compound. Optimal Cutting Temperature Embedding Medium for Frozen Tissue Specimens

Standards of Practice Emergency Shower/Eyewash Installation, Use, Testing & Maintenance

Human Strength Data Tables 10/24/06

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

Biological Activity Assay for Gibco Recombinant Proteins Chemotaxis Assay

Real World Metric System

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Transcription:

Page 1 of 5 I._PURPOSE To provide the proper collection protocol for testing. II. MATERIALS Reagents Supplies Equipment Cervical sampling: CytoBrush & Spatula or Broom in ThinPrep or SurePath Liquid Based Collection Vial [Adjunct to Pap] APTIMA vaginal swab and tube APTIMA unisex swab and tube APTIMA urine tube III. PROCEDURE ThinPrep or SurePath Liquid Based Pap Test: One specimen will be used to provide samples for both the Pap test and/or the (Trich) test. Follow the appropriate Pap collection instructions for testing of Trich. This test can be performed adjunctively from the Pap vial. APTIMA Vaginal Swab Collection [Separate from Pap]: 1. Partially peel open the swab package. Do not touch the soft tip or lay the swab down. If the soft tip is touched, the swab is laid down, or the swab is dropped, use a new Aptima Vaginal Swab Kit. 2. Remove the swab. 3. Hold the swab, placing your thumb and forefinger in the middle of the swab shaft.

Page 2 of 5 4. Carefully insert the swab into the vagina about two inches past the introitus and gently rotate the swab for 10 to 30 seconds. Make sure the swab touches the walls of the vagina so that moisture is absorbed by the swab. 5. Withdraw the swab without touching the skin. 6. While holding the swab in the same hand, unscrew the cap from the tube. Do not spill the contents of the tube. If the contents of the tube are spilled, use a new Aptima Vaginal Swab Kit. 7. Immediately place the swab into the transport tube so that the tip of the swab is visible below the tube label. 8. Carefully break the swab shaft at the scoreline against the side of the tube and discard the top portion of the swab shaft. Do not spill the contents of the tube. If the contents of the tube are spilled, use a new Aptima Vaginal Swab Specimen Collection Kit. 9. Tightly screw the cap onto the tube. APTIMA Endocervical/Male Urethra Swab Collection [Separate from Pap]: Endocervical swab specimens 1. Remove excess mucus from the cervical os and surrounding mucosa using the cleaning swab (white shaft swab in the package with red printing). Discard this swab. Note: To remove excess mucus from the cervical os, a large-tipped swab (not provided) may be used. 2. Insert the swab (blue shaft swab in the package with the green printing) into the endocervical canal. 3. Gently rotate the swab clockwise for 10 to 30 seconds in the endocervical canal to ensure adequate sampling. 4. Withdraw the swab carefully; avoid any contact with the vaginal mucosa. 5. Remove the cap from the swab specimen transport tube and immediately place the swab into the transport tube. 6. Carefully break the swab shaft against the side of the tube at the scoreline and discard the top portion of the swab shaft; use care to avoid splashing of contents. 7. Re-cap the swab specimen transport tube tightly. Male urethral swab specimens: 1. The patient should not have urinated for at least 1 hour prior to sample collection. 2. Insert the swab (blue shaft swab in the package with the green printing) 2 to 4 cm into the urethra. 3. Gently rotate the swab clockwise for 2 to 3 seconds in the urethra to ensure adequate sampling. 4. Withdraw the swab carefully. 5. Remove the cap from the swab specimen transport tube and immediately place the swab into the transport tube.

Page 3 of 5 6. Carefully break the swab shaft against the side of the tube at the scoreline and discard the top portion of the swab shaft; use care to avoid splashing of contents. 7. Re-cap the swab specimen transport tube tightly. Urine Collection: 1. The patient should not have urinated for at least 1 hour prior to specimen collection. 2. Direct patient to provide a first-catch urine (approximately 20 to 30 ml of the initial urine stream) into a urine collection cup free of any preservatives. Collection of larger volumes of urine may result in rrna target dilution that may reduce test sensitivity. Female patients should not cleanse the labial area prior to providing the specimen. 3. Remove the cap and transfer 2 ml of urine into the urine specimen transport tube using the disposable pipette provided. The correct volume of urine has been added when the fluid level is between the black fill lines on the urine specimen transport tube label. 4. Re-cap the urine specimen transport tube tightly. This is now known as the processed urine specimen. IV. QUALITY CONTROL Minimum Volume: 1 ml Storage Requirements: Cervicovaginal ThinPrep/SurePath liquid based Pap vial at 2 C to 30 C. Vaginal APTIMA swab specimen transport tube at 2 C to 30 C. Endocervical APTIMA swab specimen transport tube at 2 C to 30 C. Urine APTIMA urine specimen transport tube at 2 C to 30 C. Fresh at 2 C to 8 C. Stability Requirements: Cervicovaginal, Vaginal, & Endocervical APTIMA swab specimen transport tube or ThinPrep liquid based Pap preservative vial 4 weeks from collection. SurePath is 2 weeks from collection. Urine APTIMA urine specimen transport tube 4 weeks from collection. Urine samples that are still in the primary collection container must be transported to the lab and transferred into the APTIMA urine specimen transport tube within 24 hours of collection. V. CALCULATIONS/CALIBRATION

Page 4 of 5 VI. INTERPRETATIONS VII. METHOD PERFORMANCE SPECIFICATIONS VIII. REFERENCES IX. RELATED DOCUMENTS

Page 5 of 5 X. DOCUMENT HISTORY Minor Revision (Laboratory Director s Signature on Original Subsequent Document Attached) Major Revision (Requires Laboratory Director & Department Director Signature - where applicable) Reason for Change 1/02/14 New Document Control Format Laboratory Director: Natalie Depcik-Smith, MD Department Director: Designee: