COATINGS SPRAY GUIDE Fast Set Urethane 530

Similar documents
COATINGS SPRAY GUIDE Urethane 520

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212)

GACOFLEX TWO-COMPONENT LIQUID POLYURETHANE SPRAY GUIDE UA-60, U-64, UB-64, UA-7090, U-66

TECTYL 1422S APPLICATION PROCEDURES AND TROUBLESHOOTING GUIDE

As Supplied : 1.67 lbs/gal (200 g/l) Plasite Thinner #71 : 10% by volume 2.18 lbs/gal (261 g/l)

Aerodur 2111 Chrome Free Primer

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

ISONATE M 125. Technical Data Sheet. Diphenylmethane Diisocyanate. General Description

Two coats are normally recommended. Some service may require mils DFT

SAFETY IN CONFINED SPACES AND HEALTH SAFETY EXPLOSION HAZARD - TOXIC HAZARD

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

Epoxy Non-chromate Corrosion Inhibiting Primer. Alumigrip 4101P001 Alumigrip 4901 (CS4901) AkzoNobel Aerospace Coatings. Bombardier Hawker Beechcraft

Hardener: at least 24 months when stored cool and dry

Note: Only Sherwin-Williams Dimension Undercoats should be used to ensure optimum performance. 1 Dimension Hardener DH657

Positive displacement proportioning of two-component epoxy intumescent coatings for passive fire protection

SAFETY AND HEALTH IN THE USE OF CHEMICALS AT WORK

ACCU-PULSE Installation and Operation Instructions

PRODUCT DATA SHEET. Advanced Industrial Coatings 2.1 VOC Epoxy Primer AIP302 Gray, AIP303 White PERSONAL PROTECTION SURFACE PREPARATION

APPLICATION GUIDE ECOSPEED FOR ALUMINIUM SURFACES

ELASTOMER PROCESSING

ICYNENE INSTALLATION INSTRUCTIONS

PRESSURISED PAINT CONTAINER

two component solvent free amine cured phenolic epoxy coating (1 g/cm³ = 8.25 lb/us gal; 1 m²/l = 40.7 ft²/us gal) (data for mixed product)

Vision Painting Inc Safety Management System

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

*Valid if manufactured at a certified location. Light Grey (0700), White (0800), and Light Blue (0100). Colors are unmatched

Carboguard 893 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

43P Airless Gun MODEL: DESCRIPTION

TABLE OF CONTENTS PART 2 - CONFINED SPACES

DFT in excess of 8.0 mils per coat is not recommended.

*RTS not recommended for immersion service. Do not exceed 10 mils in a single coat (without additives)

two component solvent free amine cured phenolic epoxy coating

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

SAFETY DATA SHEET. Allied Food Grade AW 68 SECTION 1: PRODUCT IDENTIFICATION

Moving Fluids Concept and Theory

TC751 Tec/BASE High Performance Clearcoat

DISPENSING VALVE MODEL VDP100 INSTRUCTION MANUAL

CONFINED SPACE PROGRAM

Binks SV100 Conventional Suction Feed Spray Gun

MATERIAL SAFETY DATA SHEET

Polidura Glossy PU Topcoat Component A: 6103 Component B: 6199

ProAir Clear LV 2 Pack

INSTRUCTION MANUAL AIRMIX AUTOMATIC SPRAY GUN

Pressure Regulators. Operating Instructions. Instrumentation

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Autoclear Superior Pack FOR PROFESSIONAL USE ONLY

SAFETY DATA SHEET Rain-X Multi-Surface Water Sealer. 1. Product and Company Identification

TECHNICAL DATA SHEET

ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL

Heresite VR-514 T E C H N I C A L D A T A S H E E T

REFLECTIT. Reflectit Spray Application Instructions DS % Acrylic Coating Providing a Pearlescent Appearance

118 - Quick-Start Processing

General Precautions for handling compressed gases

3500 PSI Airless Spray Gun

ITW RANSBURG REA AND VECTOR

NORMAL OPERATING PROCEDURES Operating Parameter Information

Hodge Clemco Ltd. SG-300 Suction Gun. Owner s Manual. Hodge Clemco Ltd

LABORATORY FUME HOOD SPECIFICATION AND MAINTENANCE PROGRAM

INDUSTRIAL - SOLVENT PARTS CLEANER

Title: Contaminated Equipment

Installation Instructions

PRODUCT DATA SHEET Planet Color Barrett-Jackson Restoration System Single Stage Color VOC

General Instructions:

Imron Industrial Strength Ultra Low VOC Polyurethane Clear Reduced Gloss Modifications

JEFFERSON COLLEGE PAINT I

Guide for Evaluating Your Hose Assembly Supplier

Binks MACH 1 PCX HVLP SPRAY GUN

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

NHR-X-X Encore Feed Hoppers

7500 PSI Airless Spray Gun

CONTENTS INSTRUCTIONS SET SAFETY. Optimum Temperature Dwell Time Re-application Removal + Cleanup

OPERATION / 3Z9305G 1:1 RATIO TRITON / Spray Packages / / / List of Models, page 2 / / / 100 psi (7 bar, 0.7 MPa) Maximum Working Pressure

COMPONENT CAS NUMBER CONCENTRATION Salmon Oil %

ARCHITECTURAL GUIDELINES FOUR-PIECE COMMERCIAL

3 Choosing the Right Respirator

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Safety Powder Spray Systems

Safe Work Practices / Procedures / Instruction CONFINED SPACE

Title: Abrasive Blasting Effective Date: 11/17/2014 Control Number: THG_0034 Revision Number: 1 Date: 10/22/2015 Annual Review Completed: 5/13/2015

MATERIAL SAFETY DATA SHEET

Tentec. Instruction Document. Mini Air Driven Pump Unit Model: HTT.627X Series. Part Identifier

SOLAR ENERGY. solutions. adhesives, sealants, and Potting encapsulants For solar energy applications

PANACEA P200 STAINLESS STEEL USER MANUAL

Standard and Low-Flow Metric Powder Feed Pumps

BINKS SV100 HVLP PRESSURE FEED SPRAY GUN

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Advanced Fluid Handling Cart Owner s Manual

Plasma 40 Torch Operating manual

Instructions-Parts List

Controlling Benzene Exposure

Intended Use of Product: For R&D materials science use only, not intended for drug or household use.

SECTION 1: PRODUCT IDENTIFICATION

Desoprime. HS Primers. CA 7700 Series Application Guide. Where Smart Solutions Take Flight

Safety Manual Section 6 Confined Space

HIGH PRESSURE DRILLING FLUID PUMP

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016

PACKAGING: Component A W-THANE HBA CD (2,7 L) Component B W-THANE 5057 CD (0,9 L)

RPE with a UK Standard Assigned Protection Factor 10 (APF10)

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

Transcription:

This guide covers handling and plural component airless spray application of AWS FAST SET URETHANE 530 elastomeric coating systems. This system is two component, 1:1 ratio by volume, liquid applied coatings which polymerize through chemical reaction of the mixed components. The cured product is a tough, waterproof and weatherproof elastomeric membrane suitable for a variety of applications. AWS FAST SET URETHANE 530 is a fast set coating systems that has a 30-second or less pot life. Cure time can vary depending on substrate temperature and product being sprayed. Coating can be walked on in a matter of minutes depending cure time. Substantial cure is achieved in two to six hours. These features make plural component airless spray the only practical application method. Personnel using this product must familiarize themselves with procedures for personal safety, workplace precautions and equipment operation. Refer to Product Data Sheet and Material Safety Data Sheets for product information. Refer to equipment manufacturer's instructions for equipment operation, maintenance and safety. SAFETY EQUIPMENT AND VENTILATION AWS FAST SET URETHANE 530 is a one to one ratio by volume two component systems in which separate components are mixed together to form the finished product. One component is identified as ISO (isocyanate) component and the other as POLY (polyol) component. Heated spray application of the mixed components creates finely atomized particles and vapor which requires specific procedures to minimize both health and safety risks. Protective Equipment 1. Use supplied air-breathing apparatus with full-face mask or hood during any spray application unless monitoring demonstrates MDI exposure below OSHA permissible limits. 2. Fabric coverall. 3. Impervious gloves. Indoor Spraying Precautions 1. Isolate the area to be sprayed from the rest of the building. 2. Spray only on well ventilated area. Air exhausted from the spray area must be directed in a manner that prevents return through windows, doors or intake vents. 3. Keep spectators and other non-essential personnel away from spray area. 4. Be sure to take proper precautions to not spray over unprotected energized lighting or electrical outlets. Doing so could be a fire hazard. Electrical wiring and conduit can be sprayed on as long as open energized circuits are protected. WWW.AMERICANWEATHERSTAR.COM Page 1 of 5

Outdoor Spraying Precautions 1. Rope off the area within 150 feet of spray area depending on wind and weather conditions. 2. Seal off ventilation intakes within the affected area. 3. Use windbreaks, where necessary to confine spray mist and avoid damage to nearby surfaces due to overspray or drift. 4. Keep spectators and other non-essential personnel away from spray area. 5. Be sure to take proper precautions to not spray over unprotected energized lighting or electrical outlets. Doing so could be a fire hazard. Electrical wiring and conduit can be sprayed on as long as open energized circuits are protected. STORAGE AND HANDLING Storage 1. Keep containers closed. Store in a dry place away from heat sparks open flame and moisture. 2. Store material above 40 F and below 100 F. Handling 1. The ISO component will freeze if exposed to temperatures below 40 F during shipping and storage. Graininess or cloudiness in the ISO indicates frozen material that must be thawed before use. 2. Mix poly component separately before use to suspend any settled pigment and assure uniform consistency. WWW.AMERICANWEATHERSTAR.COM Page 2 of 5

EQUIPMENT Plural component airless spray equipment must be capable of metering components within +/- 2% of 1:1 ratio by volume. AWS FAST SET URETHANE 530 is a 100% solids fast cure coating which require high material spray pressure and warm components to lower viscosity. This allows for the impingement mixing action provided by most plural component spray guns. The following equipment parameters have been proven effective. These equipment systems allow for the material pressures, temperatures and flow rates to generate intensive and thorough mixing of the components for optimum physical properties of the applied product. Airless spray equipment generates very high fluid pressure. Spray equipment must be properly maintained and operated. Any misuse of spray equipment (such as overpressurizing, modified parts, or worn or damaged parts) can result in serious bodily injury, explosion, or property damage. Read and follow equipment manufacturer's instructions and recommendations. 1. Drum transfer pumps are required to adequately supply the metering pumps. Drum transfer pumps must be 2:1 or 5:1 fluid to air ratio pumps with a minimum 200 psi delivery pressure. 2. Primary material heaters must be capable of heating each component 170ºF to 185ºF at the flow rate generated by the proportioning system. 3. Heated Airless spray hoses must be employed to maintain temperature developed by the primary heaters and deliver adequately heated material to the spray gun. Follow the equipment manufacturer's recommendations on maximum hose length possible while supplying adequate operating pressure at the gun. Increasing the hose length and/or raising the spray gun high above the proportioning pump, i.e., spraying on a high building with the unit at ground level will reduce the operating pressure at the gun. 4. Satisfactory results have been achieved with Graco's Fusion Air Purge gun using an AF4242 flat mix chamber and FT0838 flat fan tip. Product results may vary with different gun set ups and pressures, the bigger the mix module and fan tip the more pressure required. 5. Mix chamber and spray tip will determine the volume and spray pattern of the applied material. Choose a tip appropriate for the nature of the project. 6. Proportioning systems are available from several manufacturers. In addition, hybrid systems are offered by various equipment distributors. The following recommendations are examples of appropriate equipment systems. WWW.AMERICANWEATHERSTAR.COM Page 3 of 5

Equipment System Examples Name Model Maximum Rated Pressure Heat Rating Maximum Hose Length Graco Reactor EXP 2 3500 15,300 watts 310 2 Graco Reactor HXP2 3500 15,300 watts 310 1.5 Graco Reactor HXP3 3500 15,300 watts 310 3 GPM EQUIPMENT OPERATION After the equipment system is assembled and its proper operation verified, fill the system with product. Note: If using a system that has had other chemical products in it, verify component compatibility with AWS FAST SET URETHANE 530 components before filling equipment. Many chemical systems have polyol and iso components. It is common for plural component application systems to have a dedicated and identified iso side and a dedicated and identified poly side. Do not cross contaminate equipment supply. Always identify components with proper supply feed; do not rely on letters or numbers since they may be misleading. In some cases it may be necessary to solvent clean system to assure effective results. A. Equipment heat - Application temperature is nominally 170 F to 185 F for both components. Set primary material heaters and hose heat controls accordingly. Preheating the material to 100 F may be necessary for application depending on ambient air, material and substrate temperatures. B. Static pressure - Static or stall pressure must be set to a minimum of 2500 psi. Long hose lengths or spraying at elevations considerably above equipment level may require higher stall pressure. C. Spray pressure - Spray pressure is the dynamic pressure as measured while the spray trigger is open and material is being applied. Spray pressure registered at the proportioning pumps must be a minimum of 2200 to 2300 psi. Due to variables in component chemistry and equipment operation it is possible that there will be a difference in pressure readings between iso and poly components. A difference of up to 200 psi is allowable and is not a sign of equipment malfunction. In the event that the pressure difference is greater than 200 psi, check and clean all gun filters and low pressure filters. If the pressure difference is still above 200 psi, please call American WeatherStar or your equipment supplier for assistance. D. Spray gun - Satisfactory results have been achieved with Graco's Fusion Air Purge gun using an AF4242 flat mix chamber and FT0838 flat fan tip. Product results may vary with different gun set ups and pressures, the bigger the mix module and fan tip the more pressure required. WWW.AMERICANWEATHERSTAR.COM Page 4 of 5

E. Inline filters - Plural component spray systems commonly have one or more filters for both iso and poly components. Filters may be low pressure on the feed side or high pressure on the spray side of the system or a combination of both. Check and clean filters daily. Filter screens should be 30 or 40 mesh. F. Dry air or nitrogen purge - If the contents of a container are not to be used within one day's time, it is advised that dry air or nitrogen gas be used to blanket the iso and poly components to eliminate product skinning. APPLICATION TECHNIQUE AWS FAST SET URETHANE 530 is applied by airless spray to desired thickness in one pass. The fast cure and zero VOC features of these products allow unlimited application thickness on smooth, flat surfaces. On vertical or rough surfaces, apply two or more passes allowing no more than three to ten minutes between passes. For additional information refer to the product data sheet. WWW.AMERICANWEATHERSTAR.COM Page 5 of 5

This Page Intentionally Left Blank.