3M Water Filtration Products

Similar documents
FlashGARD HP Reverse Osmosis Filtration System Model Number FSTMO75 Part Number

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 3035 INSTRUCTION MANUAL

Installation, Operation and Maintenance Manual

Vessel Installation and Operating Manual

Installation, Operation, and Maintenance Manual

INSTALLATION INSTRUCTION

Installation & Instruction Manual For Portable Series R.O. units:

1020 Industrial Drive, Orlinda, TN fax

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

Installation and Operating Manual

Light Commercial Reverse Osmosis System. EE-1000 Manual

INSTALLATION INSTRUCTION & OWNER S MANUAL

SpectraPure PUMPED RO SYSTEMS (PSP) User s Manual for PSP-1500 Systems

Accu-Tab Systems 2000 P Series by Axiall Corporation

3M Liqui-Cel EXF-14x28 and 14x40 Series Membrane Contactor

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

Owner s Manual AMERICAN. LiquaGen 5 Stage (RO/DI) Aquarium Reef System. YEAR Y 1

INSTALLATION, OPERATION AND MAINTENANCE MANUAL ZERO WASTE REVERSE OSMOSIS SYSTEM

TOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

TOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual

UltRo Dual Flow Reverse Osmosis Water System

Accu-Tab Systems 1000 Series by Axiall Corporation

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

MN-800-TF REVERSE OSMOSIS TREATMENT SYSTEM OWNERS MANUAL

US WATER DENTAL OFFICE PURIFICATION SYSTEM

User Instruction Manual

453 Series Steam Heated Vaporizing Regulator

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

4 and 8 Station PDS Control Installation & Operators Manual

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

PoolNaturally. Pure. Simple. Genius. Installation and Product Use Instructions In ground and above ground pools

Installation Guide & Owner s Manual. Model V4700. Water Filtration for Dental & Medical Instrument Washing Equipment

Acid- Rite ph Adjustment System 2500 by Axiall, a Westlake Company

Iron Filter Installation / Operation Manual

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

BS Series Basket Strainer

Pure Water Power Purification System 4-Stage RODI Operations Manual

D Series Air and Water Kit Part# 02550

3M Liqui-Cel EXF-4x13 and 4x28 Series Membrane Contactors

J Air and Water Kit Instructions Part# 02584

SElECTING A MOUNTING location OPERATING SPECIFICATIONS* * For individual cartridge specifications, refer to cartridge literature.

Remineralized Reverse Osmosis System

Owners Manual Models: 200-CHS-XXXX-XX. US Water Systems Cobalt Hyper-Safe Reverse Osmosis System. Visit us online at

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

ROPV R40 E Series User Manual

Pressure Dump Valve Service Kit for Series 2300 Units

Crystal Quest Voyager Series Inline Water Filter Systems INSTALLATION AND OPERATION GUIDE

REVERSE OSMOSIS INSTALLATION Watermark 4 Stage

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

3M Liqui-Cel EXF-10x28 Series Membrane Contactor with ANSI or JIS Connections with Integrated End Caps

Types 749B and R130 Changeover Manifolds

U S E R M A N U A L CAUTION. SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician.

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Twin System Triple System Quad System

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

Accu-Tab PowerBase 3012AT by Axiall Corporation

FLUSHMATE III FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual. 503 Series. 503 Series

MANUAL BE SERIES Test Benches

RK-IR Sample Draw Aspirator Adapter Operator s Manual

TABLE OF CONTENTS. Purchase Records... Introduction... Component List... Diagram... Specifications... Quick Connect Guide...

Purifier for Vinyl Lined Pools

Interface Devices, Inc. Hydraulic Mini Mule

HAYWARD FLOW CONTROL FLV SERIES, PVC/CPVC FILTER VESSEL INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Model ASSEMBLY and OPERATING INSTRUCTIONS

Operation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax

CHEMICAL INDUCTION KIT (Pt.No Issue 6, October 2015)

Sterisil Ac+ Installation & Operating Manual

Freedom8 ShoeBox Compressor Manual

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

Easy Nest Kits. Installation Suggestions

accidents which arise due to non-observance of these instructions and the safety information herein.

Nitrogen Supply System

Accu-Tab PowerBase 3070AT by Axiall Corporation

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

3 Scotch-Weld Polyurethane Reactive Adhesive Applicator Replacement Part Installation Guide

PURITY INSTALLATION INSTRUCTIONS MODEL P40

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

PC1131 Electric Air Compressor

APCO ASU-SCAV & ASU-CAV SINGLE BODY COMBINATION AIR VALVES

Your safety and the safety of others are very important.

Installation and Operation 370ESP (Electric Single-Point Purger) & 370ESPR (Retrofit Purger)

KJ4000 Operating Instructions & Parts Manual NSN

Pressure Dump Valve Service Kit for Series 3000 Units

RK LEL Sample Draw Aspirator Adapter Operator s Manual

CART FOR CENTURION 1500+

4-in-1 Professional Inflator Kit

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

200 PSI FAST-FILL AIR SOURCE KIT

User's Manual. MixRite TF 10. Edition 05.08

Transcription:

3M Water Filtration Products Installation and Operation Instructions for ScaleGard TM HP Reverse Osmosis System Installer: Please leave this manual with owner/operator. Owner/Operator: Please retain for operation and future instructions.

Table of Contents Safety Information...2 Caution Statements...3 Parts List...4 Feedwater Requirements...5 Other Requirements...5 Equipment Set-Up and Installation...6 SAFETY INFORMATION System Start-Up...9 Troubleshooting Guide...10 Product Replacement Parts...10 Routine Maintenance...11, Back Cover Limited Warranty... Back Cover Read, understand, and follow all safety information contained in these instructions prior to installation and use of the 3M Water Filtration Products ScaleGard HP reverse osmosis system. Retain these instructions for future reference. Intended use: The ScaleGard TM HP reverse osmosis system is intended for use in filtering potable water for foodservice coffee, espresso, cold beverage, ice, vegetable mister and steamer equipment and has not been evaluated for other uses. This system is a centralized multi-equipment reverse osmosis system, and must be installed by a qualified professional installer according to these installation instructions and local codes. EXPLANATION OF SIGNAL WORD CONSEQUENCES WARNING Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or property damage. Indicates a potentially hazardous situation, which, if not avoided, may result in property damage. WARNING To reduce the risk associated with the ingestion of contaminants: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. EPA Establishment #070595-CT-001 An approved air gap must exist between the RO system reject drain line and the drain opening to comply with state and local plumbing codes. To reduce the risk associated with choking: Do not allow children under 3 years of age to have access to small parts during the installation of this product. To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric or water pipes in the area of installation: Do not install near electric wiring or piping which may be in path of a drilling tool when selecting the position to mount the system bracket. To reduce the risk of physical injury: Depressurize system as shown in manual prior to cartridge removal. All hydro-pneumatic pressurized tanks must have an appropriate pressure relief valve installed. To reduce the risk of injury associated with household bleach: Read and follow manufacturer s directions and cautions. Keep out of the reach of children. DO NOT intermix with other chemicals. To reduce the risk associated with ingestion of water contaminated with sanitizer: After installation, sanitizers must be flushed from the system before first use as directed within the installation instructions (dilute bleach solution). To reduce the risks associated with hazardous voltage: Do not modify this product in any way. Use only 3M-approved replacement parts. To reduce the risks associated with hazardous voltage: Do not use this product if any damage has occurred to the electrical portion of this product. Refer repairs to 3M authorized service provider before putting product back into service. 2

To reduce the risks associated with hazardous voltage: Remove power from product before performing maintenance or service. To reduce the risk associated with back strain: Follow safe lifting procedures. WARNING To reduce the risks associated with environmental contamination: At the end of useable life, dispose of this system in accordance with applicable local regulations or laws. To reduce the risk associated with property damage due to water leakage: Read and follow Use Instructions before installation and use of this system. Installation and use MUST comply with all state and local plumbing codes. Before starting installation, shut off main water supply and drain pipes. Protect from freezing, remove filter cartridge when temperatures are expected to drop below 40 F (4.4 C). Do not install systems in areas where ambient temperatures may go above 110 F (43.3 C). Do not install on hot water supply lines. The maximum operating water temperature of this system is 100 F (37.8 C). Do not install if water pressure exceeds 125 psi (862 kpa). If your water pressure exceeds 80 psi (552 kpa), you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure. Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition. Where a backflow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion must be installed. Do not use a torch or other high temperature sources near system, cartridges, plastic fittings or plastic plumbing. On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic. Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if over tightening occurs. Do not install in direct sunlight or outdoors. Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket. Mount system in such a position as to prevent it from being struck by other items used in the area of installation. Ensure that the location and fasteners will support the weight of the system when installed and full of water. Ensure all tubing and fittings are secure and free of leaks. The RO cartridge MUST be replaced every twenty four (24) months, or sooner if a noticeable increase in TDS occurs. The disposable filter cartridges MUST be replaced every six (6) months, at the rated capacity or sooner if a noticeable reduction in flow rate occurs. Tank Pre-charge Pressure should be checked yearly. All hydro-pneumatic pressurized tanks must have an appropriate pressure relief valve installed. Use flexible plumbing lines to system inlet and outlet connections. IMPORTANT NOTES Failure to follow instructions will void warranty. Allow a minimum of 3 (6.72 cm) clear space under filter to facilitate cartridge change. Install with the inlet and outlet ports as labeled. Make sure not to reverse connections. Some local codes may require the use of a licensed plumber or certified installer when disrupting a potable water line. 3

Parts List The following parts comprise the ScaleGard TM HP reverse osmosis system. Please unpack the contents from the product box and check to verify that all of the parts listed below are included. Should any parts be missing, please contact 3M Purification Inc. at 1-866-990-9785. Description Quantity Part Number ScaleGard TM HP Reverse Osmosis System 1 5629101 (110V with Pre-filter and RO) 6239301 (110V w/out Pre-filter and RO) 6239302 (220V w/out Pre-filter and RO) HF90-CL-RO (Pre-Filter) 1 5613529 HFRO 500 (RO membrane) 1 5626903 Optional Equipment Sold Separately Description Quantity Part Number BEV140/BEV160 Post Filter (not included) 1 5616201/5616301 Pressure Tank (not included) 1 56-1517161 Install Kit (not included) 1 6841441 4

Feedwater Requirements To reduce the risk associated with property damage due to water leakage: Read and follow Instructions before installation and use of this system. Installation and use MUST comply with all state and local plumbing codes. Before starting installation, shut off main water supply and drain pipes. Do not install on hot water supply lines. The maximum operating water temperature of this system is 100 F (37.8 C). Do not install if water pressure exceeds 125 psi (862 kpa). If your water pressure exceeds 80 psi (552 kpa), you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure. Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition. IMPORTANT NOTES Be sure to confirm that the feedwater falls within the limits shown below. If unsure of the feedwater quality, check with your 3M Water Filtration Products distributor. Inlet water pressure...30-125 psi (207-862 kpa) Feed TDS... 1,000 ppm Maximum Hardness...<10 grains (171 mg/l) Iron (Fe)... <0.1 mg/l Hydrogen Sulfide... None Allowed Feed ph...4-11 Free Chlorine... <0.1 mg/l Manganese (Mn)...<0.05 mg/l Turbidity...<5 NTU Other Requirements Power...110V (PN-5629101, 6239301), 220V (PN-6239302) 5

Equipment Set-Up and Installation To reduce the risk associated with property damage due to water leakage: Read and follow Instructions before installation and use of this system. Installation and use MUST comply with all state and local plumbing codes. Before starting installation, shut off main water supply and drain pipes. Protect from freezing, remove filter cartridge when temperatures are expected to drop below 40 F (4.4 C). Do not install systems in areas where ambient temperatures may go above 110 F (43.3 C). Do not install on hot water supply lines. The maximum operating water temperature of this system is 100 F (37.8 C). Do not install if water pressure exceeds 125 psi (862 kpa). If your water pressure exceeds 80 psi (552 kpa), you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure. Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition. Do not use a torch or other high temperature sources near system, cartridges, plastic fittings or plastic plumbing. On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic. Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if over tightening occurs. Do not install in direct sunlight or outdoors. Ensure all tubing and fittings are secure and free of leaks. The RO cartridge MUST be replaced every twenty four (24) months, or sooner if a noticeable increase in TDS occurs. The disposable filter cartridges MUST be replaced every six (6) months, at the rated capacity or sooner if a noticeable reduction in flow rate occurs. Equipment Location Prior to installing the ScaleGard TM HP reverse osmosis system, carefully plan the installation location for all system components. Position the ScaleGard TM HP reverse osmosis base unit and the pressure tank in desired locations as per (Figure 1). 1. Access to feedwater and drain line connection are required. 2. The ScaleGard TM HP reverse osmosis system components should ideally be accessible and have at least 3 inches (7.62 cm) clearance on all sides of the system to facilitate servicing. 3. The ScaleGard TM HP reverse osmosis base unit should ideally be installed within 15 ft (4.6 m) of the pressure tank and 0.5 or larger tubing diameter is required to complete installation. Figure 1 Plumbing Diagram Bypass (Provided by Installer) Check Valve (Provided by Installer) RO sample valve To Equipment 1/2 NPT Feed Water Inlet Install kit shutoff valve (Sold Separately) Pre-Filter sample valve 3/8 Tube Out to drain HF90-CL-RO (Pre-Filter) HFRO 500 (RO Membrane) 1/2 Outlet to tank 1/2 NPT Outlet to Equipment Install kit shutoff valve (Sold Separately) 20 Gal. Pressure Tank (Sold Separately) Tank shut off valve (Comes with Tank) BEV140/BEV160 (Post Filter-Sold Separately) Legend Provided by Installer Installation Kit 6

Wall Mounting the ScaleGard TM HP Base Unit 1. Draw a level line on the wall where the bracket is to be mounted. Hold bracket key holes on level line and mark locations for screws. 2. Install mounting screws (not included) into each of the intial key holes as shown in figure 2. Be sure to leave 1/8 to 1/4 (0.3 to 0.6 cm) space between the bottom of the screw head and the wall so that the bracket can be hung. (assume system weight of 50lbs.) To reduce the risk associated with property damage due to water leakage: Mount ScaleGard TM HP base unit in such position as to prevent it from being struck by other items being used in the area of installation. Ensure that the location and fasteners will support the weight of the system when installed. IMPORTANT NOTES Allow a minimum of 3 (7.62 cm) clear space under filter to facilitate cartridge change. 3. Hang manifold from the mounting screws. 4. Once the bracket is hung, tighten the mounting screws so that the bracket is snug between the screw and the wall. 5. Install remaining mounting screws in locations as shown in figure 2. MOUNTING HOLES Figure 2 Installing Mounting Screws MOUNTING HOLES MOUNTING HOLES 7

Plumbing Connections tank pre-settings of 40-60 psi ([276-414 kpa]) 1. Install feed water line to marked Inlet 1/2 NPT inlet connection. 2. Install RO water line from marked Tank Outlet to pressure tank (Sold Separately). (Assemble and install pressure tank per instructions provided with tank.) 3. Install RO water line from marked Equipment Outlet to the foodservice equipment. If connecting to Beverage/Coffee equipment then the installation of an optional post filter is recommended. 4. Install drain line from marked Drain Outlet to the drain. An approved air gap must exist between the RO system reject drain line and the drain opening to comply with state and local plumbing codes. 5. Install 1/2 Bypass line as shown on Figure 3-Plumbing Diagram. 6. Check air pressure on the pressure tank using the valve on the tank. With the tank empty, the pressure should read between 7-18 psi (48-124 kpa). Adjust as required. 7. Plumbing connections for the ScaleGard TM HP reverse osmosis system is now complete. Install cartridge per instructions below. To complete the System Start Up procedure for the ScaleGard TM HP reverse osmosis system please refer to the System Start Up section in page 9. Figure 3 Plumbing Diagram Bypass (Provided by Installer) Check Valve (Provided by Installer) 1/2 NPT Feed Water Inlet Install kit shutoff valve (Sold Separately) Pre-Filter sample valve 3/8 Tube Out to drain HF90-CL-RO (Pre-Filter) HFRO 500 (RO Membrane) RO sample valve 1/2 Outlet to tank 1/2 NPT Outlet to Equipment Install kit shutoff valve (Sold Separately) 20 Gal. Pressure Tank (Sold Separately) Tank shut off valve (Comes with Tank) To Equipment BEV140/BEV160 (Post Filter-Sold Separately) Legend Provided by Installer Installation Kit HF90-CL-RO Cartridge (blue label) Installation: 1. Remove red sanitary cap from new cartridge. Install with a quarter turn to the right until cartridge come to a complete stop. NOTE: Cartridges are keyed to fit in proper location only. HFRO 500 Cartridge (green label) Installation: 1. Take out reject tubing by pushing in the collet and pulling out the tubing. (See figure 6 on back page). 2. Remove sanitary cap from new cartridge. Install with a quarter turn to the right until cartridge comes to a complete stop. NOTE: Cartridges are keyed to fit in proper location only. 3. Place new flow control in reject tubing (supplied with cartridge). 4. Connect reject tubing to cartridge. 8

System Start Up 1. Turn ON the feedwater supply by plugging system into electrical outlet. 2. Press reset button on top of electrical enclosure (see Figure 4). 3. Open Pre-filter flush valve to vent air from system and flush for five (5) minutes. 4. Close flush valve. 5. Complete blending valve adjustment procedure below. 6. Allow tank to fill until the RO unit turns OFF on full tank (see chart). 7. Turn OFF the feedwater supply by unplugging system from electrical outlet. 8. Open pressure tank sample valve and empty tank to drain. Close tank sample valve. 9. Sanitize the Storage Tank and Filtration System as per instructions below Sanitizing the storage tank generally requires: Common household bleach (5.25% non-scented) or sanitizing agent Eye dropper or plastic oral syringe a.) Disconnect the 1/2 line from marked Tank Outlet to pressure tank. b.) Insert 1 tablespoon of bleach or sanitizing agent into 1/2 line to pressure tank. c.) Reconnect the 1/2 line to pressure tank. d.) Turn ON the feedwater supply by plugging system into electrical outlet. e.) Wait 4-5 hours. f.) Open pressure tank sample valve and empty tank to drain. g.) Sanitizing is now complete. h) If there is any residual chlorine/bleach taste in the next tank full, drain tank completely a second time. 10. Allow tank to fill again. System is now ready for use. Figure 4 (Reset Button) Optional Tanks (Sold Separately) Part Number Pressure Volume Reset Button Approximate Time to Fill 5598407 10 gallons (38 liters) 0.3 hours 5598408 20 gallons (76 liters) 0.6 hours 5598409 40 gallons (151 liters) 1.2 hours Blending Valve Adjustment Procedure IMPORTANT NOTES: Typical TDS (Total Dissolved Solids) values for coffee are 80-200 ppm and occasionally lower for espresso, depending upon taste preference. The blending valve should be set at start-up and checked periodically, for example when changing filter cartridges. The valve is a precision metering valve, that may be locked by tightening lock nut. In order to set the blending valve, bypass valve must be closed. The system TDS output can be measured via the TDS meter position out. The system TDS input can be measured via the TDS meter position in. 1. Close the outlet shut-off valve to downstream equipment and the tank shut-off valve and open the RO sample valve at the tank. 3. To adjust blending, rotate the blending valve to the left (counterclockwise) to increase the product water TDS and to the right (clockwise) to decrease the product water TDS. The valve should be opened intermittently at 1.0 to 1.5 turns at a time. Check the TDS after each incremental adjustment and again two (2) minutes after the desired TDS value is reached. Re-adjust and check, as needed. 4. Lock the blending valve using the lock nut. IMPORTANT NOTE: The TDS Meter is push-button operated and requires two (2) 357A batteries. (included in TDS meter) 9

Troubleshooting Guide Problem Possible Cause Solution Notes Unit Runs Low or Out of Water System shuts down and service indicator light turns on TDS of product water too low TDS of product water too high TDS of product water too high with no blending Undersized tank for store demand Install additional storage tank capacity Contact Dealer RO production is to low for store demand Slow leak in the distribution line RO membrane flow control improperly installed or missing Install RO add-on head and cartridge Upgrade from HFRO 500 to HFRO 700 Cartridge Repair leak Properly install RO membrane Flow control Contact Dealer The unit produced RO water slowly. A dripping leak can prevent the tank from filling. Note: Reference RO cartridge change-out instructions Pre-Filter plugs Replace Pre-Filter A more frequent schedule change-out may be needed RO membrane fouls (normal conditions) RO membrane fouls (high feed water hardness/tds) Interrupted feedwater supply Low feedwater pressure (below 30 psi) Blend too low Blend to high Replace RO membrane Ensure drain line is not kinked or plugged. Replace if needed. Install RO add-on head and cartridge Install water softener upstream Press Reset button on top of electrical enclosure Contact plumber to resolve problem Re-adjust blending valve to allow more blending Re-adjust blending valve to allow less blending Check for: 1. feedwater pressure, 2. production flow rate, 3. drain flow rate before replacing RO membrane Contact Dealer Reference system startup procedure Reference system startup procedure once low feed water problem is resolved Reference Blending Valve Adjustment Reference Blending Valve Adjustment RO membranes defective Replace RO membranes TDS meter not operating Low battery Replace TDS meter batteries Replacement Parts Part Number Description 96-410501 Pressure Reducer/Regulator (Contact Dealer) 60-9052 Inlet ball valve (Contact Dealer) 22-518801 PLC (Contact Dealer) 8500557 Pressure Gauge (Contact Dealer) 60-125001 Permeate Solenoid (Contact Dealer) 85-9274 Shroud (Contact Dealer) 89-3220101 Pump Head (Contact Dealer) 89-2302 Pump Motor (Contact Dealer) 5613529 HF90-CL-RO Pre-Filter 5626903 HFRO 500 Cartridge 6232631 TDS Monitor 24-5500101 Flow Switch 25-15503Z Pressure Switch (40/60 psi) 50-92101/Z Inlet Solenoid (Contact Dealer) 10

Routine Maintenance Cartridge Change-Out Instructions (Pre-Filter and RO Cartridge) WARNING To reduce the risk associated with the ingestion of contaminants: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. To reduce the risk associated with choking: Do not allow children under 3 years of age to have access to small parts during the installation of this product. To reduce the risk of physical injury: Depressurize system as shown in manual prior to cartridge removal. To reduce the risk of injury associated with household bleach: Read and follow manufacturer s directions and cautions. Keep out of the reach of children. DO NOT intermix with other chemicals. To reduce the risk associated with ingestion of water contaminated with sanitizer: After installation, sanitizers must be flushed from the system before first use as directed within the installation instructions (dilute bleach solution). To reduce the risk associated with property damage due to water leakage: Protect from freezing, remove filter cartridge when temperatures are expected to drop below 40 F (4.4 C). Do not install systems in areas where ambient temperatures may go above 110 F (43.3 C). The RO cartridge MUST be replaced every twenty four (24) months, or sooner if a noticeable increase in TDS occurs. The disposable filter cartridges MUST be replaced every six (6) months, at the rated capacity or sooner if a noticeable reduction in flow rate occurs. IMPORTANT NOTE: The RO cartridges have green labels and will only fit into the head on the right side of the manifold (head has a green 3M label). Shut-Off procedure: HFRO 500 Cartridges will need to be changed at least every twenty four (24) months. HF90-CL-RO cartridge will need to be changed every six (6) months. 1. Unplug system from the wall outlet, which will shutoff feedwater to RO system. 2. Open Pre-filter sample valve until flow stops and pressure gauge reaches 0 psi to relieve pressure. HF90-CL-RO Cartridge (blue label) Replacement: 1. Remove red sanitary cap from new cartridge. Install with a quarter turn to the right until cartridge come to a complete stop. NOTE: Cartridges are keyed to fit in proper location only. HFRO 500 Cartridge (green label) Replacement: 1. Take out reject tubing by pushing in the collet and pulling out the tubing. (See figure 6 on back page). 2. Remove sanitary cap from new cartridge. Install with a quarter turn to the right until cartridge comes to a complete stop. NOTE: Cartridges are keyed to fit in proper location only. 3. Place new flow control in reject tubing (supplied with cartridge). 4. Connect reject tubing to cartridge. System Start Up 1. Turn ON the feedwater supply by plugging system into electrical outlet. 2. Press reset button on top of electrical enclosure (see Figure 5). 3. Open Pre-filter valve sample valve to vent air from system and flush for five (5) minutes. 4. Close sample valve. Figure 5 (Reset Button) Reset Button 11

Routine Maintenance (Cont.) Cartridge Change-Out Instructions (Pre-Filter and RO Cartridge) System Start Up cont. 5. Sanitize the Storage Tank and Filtration System as per instructions below Sanitizing the storage tank generally requires: Common household bleach (5.25% non-scented) or sanitizing agent Eye dropper or plastic oral syringe a.) Disconnect the 1/2 line from marked Tank Outlet to pressure tank. b.) Insert 1 tablespoon of bleach or sanitizing agent into 1/2 line to pressure tank. c.) Reconnect the 1/2 line to pressure tank. d.) Turn ON the feedwater supply by plugging system into electrical outlet. e.) Wait 4-5 hours. f.) Open pressure tank sample valve and empty tank to drain. g.) Sanitizing is now complete. h) If there is any residual chlorine/bleach taste in the next tank full, drain tank completely a second time. 6. Allow tank to fill again. System is now ready for use. To Attach Tubing Figure 6 (How to Use Push-in Connectors) This product is outfitted with a user friendly Push In connector at the vent valve. Proper use of the connectors is shown in the figure below. It is most important that the tubing selected for use with these connectors be of high quality, exact size and roundness, and with no surface nicks or scratches. If it is necessary to cut the tubing, use a plastic tubing cutter or sharp razor knife. Make a clean square cut. Should a leak occur at a Push-In connector, the cause is usually a problem with the tubing. To Fix: 1. Relieve pressure 2. Release tubing 3. Cut off at least 1/4 from end 4. Reattach tubing 5. Confirm connection is leak free To Release Tubing Push tubing straight in as far as it will go Tubing is secured in. Push in collet to release tubing. Pull tubing straight out. Limited Warranty 3M Purification Inc. warrants this Product (excluding disposable filter cartridges(s)) will be free from defects in material and manufacture for one (1) year from the date of purchase. The disposable filter cartridge or membrane is warranted from defects in material and manufacture for a period of one (1) year from the date of purchase. This warranty does not cover failures resulting from abuse, misuse, alteration or damage not caused by 3M Purification Inc. or failure to follow installation and use instructions. No warranty is given as to the service life of any filter cartridge or membrane as it will vary with local water conditions and water consumption. 3M PURIFICATION INC. MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOMER OR USAGE OF TRADE. If the Product fails to satisfy this Limited Warranty during the warranty period, 3M Purification Inc. will replace the Product or refund your Product purchase price. This warranty does not cover labor. The remedy stated in this paragraph is Customer s sole remedy and 3M s exclusive obligation. This warranty gives you specific legal rights, and you may have other rights which may vary from state to state, or country to country. For any warranty questions, please call (866) 990-9785 or mail your request to: Warranty Claims, 3M Purification Inc., 400 Research Parkway, Meriden, CT 06450. Proof of purchase (original sales receipt) must accompany the warranty claim, along with a complete description of the Product, model number and alleged defect. Limitation of Liability 3M Purification Inc. will not be liable for any loss or damage arising from the use of the Product(s), whether direct, indirect, special, incidental, or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. 3M Purification Inc. 400 Research Parkway Meriden, CT 06450, U.S.A. Tel (866) 990-9785 (203) 237-5541 Fax (203) 238-8701 www.3mfoodservice www.3mpurification.com 3M is a trademark of 3M Company. ScaleGard is a trademark of 3M Company. 2012 3M Company. All rights reserved. Please recycle. Printed in U.S.A. INSTR4400 1012