dpd Seattle Permits Tip Getting a Grip on Handrails PURPOSE OF HANDRAILS

Similar documents
Single Family Dwellings

CHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS

Small. Regulation Reference: (see page 23 for link to the regulation)

Chapter 5. General Site and Building Elements

ADA Library Accessibility Checklist

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 8 RECREATION FACILITIES

i. f ;->s- Handrails & Railings Safe Stairs LD ~ V.P.I. & S.U. LIBRARY RECOMMENDATIONS: from the series Design for Safe Habitat

OSHA 29CFR 1910 Subpart D Walking-Working Surfaces Content

ADA Access Standards for Swimming Pools, Wading Pools, and Spas

IBC: 404.1, 404.9, , , , , , TABLE

BP 344 IMPLEMENTING RULES AND REGULATIONS (IRR) AMENDMENTS MINIMUM REQUIREMENTS FOR ACCESSIBILITY

ACCESSIBILITY STANDARDS for the BUILT ENVIRONMENT

TOWN of CHEEKTOWAGA Permit Application for Swimming Pools, Hot Tubs, or Personal Spas

Location: Cariboo, One Hundred Mile House, Cariboo Chilcotin Coast - Provincial : Park (Heritage Discovery Circle Route)

FINAL EXPRESS TERMS FOR PROPOSED BUILDING STANDARDS OF THE CALIFORNIA DEPARTMENT OF PUBLIC HELATH

Van Ness Avenue Bus Rapid Transit

Park Inspection Details From 7/21/2013 To 7/21/2013

Design Overview. Section 4 Standard Plans for Design. Pedestrian Access Routes. Pedestrian Access Routes. Overview. Cross Slope

CTC Area of study Climbable Guards 2007/2008 Code Changes SECTION GUARDS

ADA PRESENTATION (CURB RAMPS)

ACCESSIBILITY CHECKLIST

NEW ZEALAND BUILDING CODE. In relation to Tredsafe

Welcome to the AccessibilityOnline Webinar Series

Discussion Paper Designing Means of Access and Related Access Aids

Field guide for Accessible Public Rights-of-Way Edition

RESIDENTIAL BUILDING PLAN REVIEW CHECKLIST

ADA Design Overview. Section 2. ADA Design Overview. Pedestrian Access Routes. Pedestrian Access Routes. Overview

Standards vs. Guidelines. Public Right-of Way Accessibility Guidelines (PROWAG)

Why Update. OSHA updated Walking Working Standard. Who & What it Covers. Housekeeping (a) 6/25/ nd Leading cause of Workplace fatalities

Figure 3B-1. Examples of Two-Lane, Two-Way Marking Applications

FINDLAY TOWNSHIP BUILDING INSPECTION DEPT

Town of Poughkeepsie Received: Permit # Aboveground/Inground Pool Building Permit Application

STAKING TRAFFIC CONTROL SIGNAL SYSTEMS

REVIEW OF ACCESSIBILITY FEATURES

Subparts D and I Walking-Working Surfaces & Personal Protective Equipment Final Rule

CHAPTER 8 STAKING SIGNALS AND LIGHTING FIELD GUIDE. 8.1 Staking Traffic Control Signal Systems

ADA COMPLIANCE CHECKLIST (RESTAURANT) Meet Fail N/A. Parking Lot

Accessible Swimming Pools and Spas

ADA Training Standard Plans

CPWR - The Center for Construction Research and Training. Fall Hazard Identification and Control Audit of the Aria Building. City Center Project

INTEGRATED ACCESSIBILITY STANDARDS REGULATION. Training Module for the Design of Public Spaces Standard

IMPLEMENTATION. PEDESTRIAN USERS (Continued /) A: Class 2 Pedestrian / Cycle Ways. Pedestrian and Cycle Ways:

Driveway Design Criteria

AMITY TWP POOL REQUIREMENTS

TGSI Tactile Ground Surface Indicators

Segment Number Quick Pathways Accessibility Tool. Name of Street: Segment Identification:

The Agility Association of Canada

FALL PROTECTION LADDERS ACCESSWAYS

WORKPLACE SAFETY INSPECTIONS TABLE OF CONTENTS INTRODUCTION...2 OBJECTIVE...2 REFERENCES...2 PREREQUISITES...2 PRECAUTIONS...2 CHECKLISTS...

ADA Operations Contact Info

Department of Public Works Office of Disability Affairs February 23, 2017 Presented by Mark Zwoyer, PE

Walking Working Surfaces Compliance Checklist

National Grain and Feed Association. NGFA Guidance Document for OSHA Walking-Working Surfaces (D)

PUBLIC POOL CHECKLIST. (This checklist is based on the Ministry of Municipal Affairs and Housing checklist)

IMPLEMENTATION. PEDESTRIAN USERS (Continued /) Building Frontages: A: Stair Applications. Geometry (Accessed from the Sidewalk) Refer to A:

Alberta Infrastructure HIGHWAY GEOMETRIC DESIGN GUIDE AUGUST 1999

TAMPA ELECTRIC COMPANY ENERGY SUPPLY WORK AREA PROTECTION PROGRAM

VISUAL AIDS FOR DENOTING OBSTACLES

Fall Protection- Part 2

SAFETY PROGRAM MANUAL INJURY & ILLNESS PREVENTION PROGRAM

VISUAL AIDS FOR DENOTING OBSTACLES

SECTION 1A NEW JERSEY TURNPIKE GEOMETRIC DESIGN

Applying Construction Fall Protection Concepts to General Industry

1/2 METER FLYTE-DECK II FIBERGLASS STAND (6' BOARD) (8' BOARD) (10' BOARD)

Let s Walk Together Safe Guiding Techniques for Individuals with Intellectual Disability and Vision Loss

CHAPTER 16 PEDESTRIAN FACILITIES DESIGN AND TECHNICAL CRITERIA TABLE OF CONTENTS

C A M P U S W I D E G U I D E L I N E S S T R E E T F U R N I T U R E

Product Catalog and Pricing

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

MEMORANDUM. NFPA Technical Committee on Lightning Protection Systems. NFPA 780 Supplement ROC TC FINAL Ballot Results (F2012Cycle)

Wisconsin Contractors Institute Continuing Education. OSHA Safety Course Course # Hours

ADA Transition Plan. Washington County. Inventory Manual. June, 2014 DRAFT

Palmer township, Pennsylvania. Pool & Fence Details Based on the 2009 International Residential Code (Designed and Printed January 2012)

PROCEDURE FOR ACCOMMODATING PEDESTRIANS IN WORK ZONES FOR CONSTRUCTION AND MAINTENANCE

WHEELCHAIR SKILLS PROGRAM (WSP) 4.1 OBSTACLE COURSE GUIDELINES

Norton Shores Building Division 4814 Henry Street, Norton Shores, Michigan Telephone: (231) Pool Requirements

1 & 3 Meter Tower CAT 1M 203R RIGHT MOUNT CAT 3M 203R CAT 1M 203L LEFT MOUNT CAT 3M 203L CAT 1M 203D DUAL MOUNT CAT 3M 203D

Circular Turning Space. 8 Significant Changes to the ICC A

Information on RESIDENTIAL SWIMMING POOLS

RESIDENTIAL SWIMMING POOL REQUIREMENTS

Swimming Pool Barrier 2015 International Swimming Pool and Spa Code

newly constructed and altered recreation facilities guidelines for newly constructed and altered buildings and facilities subject to the ADA.

This information has been developed by an OSHA Compliance Assistance Specialist and is intended to assist employers, workers, and others as they

DETECTABLE WARNING SURFACES SHALL BE PROVIDED AT THE FOLLOWING LOCATIONS ON PEDESTRIAN ACCESS ROUTES:

PEAK ALUMINUM FENCING AQUATINE Review for compliance with 2015 International Swimming Pool and Spa Code

THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD

ADA STANDARD OVERVIEW AND SPEAKMAN APPLICABLE PRODUCTS

Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards

CHAPTER 2G. PREFERENTIAL AND MANAGED LANE SIGNS

Chapter 10 SWIMMING POOLS

KDOT Access Management Policy (AMP)

Walking-Working Surfaces

RESOLUTION A.1045(27) RECOMMENDATION ON PILOT TRANSFER ARRANGEMENTS

Hot Tub Pre-Delivery Guide

KERN COUNTY PUBLIC HEALTH SERVICES DEPARTMENT ENVIRONMENTAL HEALTH DIVISION

Information Required on Building Permit Applications and Building Plans for the Installation of Swimming Pools, Spas, and Hot Tubs

Advanced Code Requirements for Residential Construction Internet Course

10 SHERFORD Town Code

Sterling Stairlifts. Lifting expectations

Transcription:

dpd Department of Planning and Development Tip 319 Seattle Permits part of a multi-departmental City of Seattle series on getting a permit Getting a Grip on Handrails Updated March 2, 2007 PURPOSE OF HANDRAILS Handrails are for safety. On stairs and ramps, they provide something to grasp for support. If someone trips or needs help with balance, handrails are there to be grasped. They are particularly important at the top and bottom of a stair or ramp, where pedestrians may need extra help in orienting themselves. The size, placement and number of handrails are governed by the either the Seattle Residential Code (SRC for single family, duplex or townhouses all with 3 or fewer stories) or the Seattle Building Code (SBC all other residences and other buildings). The type of building determines which code to use. Each of these codes gives the minimum requirements for handrails, but designers should always keep in mind the purpose of handrails, and consider adding additional ones if safety warrants them. The following rules apply equally to stairs and ramps, unless noted otherwise. (Guardrails and areas with tiered seating are not discussed here.) Projects Under the Seattle Residential Code (Section R311.5.6 Handrails) Single family houses, duplexes and townhouses have the following requirements: Number of handrails Handrails shall be provided on at least one side of each continuous flight with four or more risers. (This rule also applies to exterior stairs.) On ramps, a handrail is required on at least one side if the ramp slope exceeds 1 unit vertical to 12 units horizontal (8.33 percent slope). See Figures A.2, C.2. Height Handrails shall be mounted so that the top of the handrail is between 34 and 38 inches above the stair tread at the nosing. See Figure A.1. City of Seattle Department of Planning & Development Continuity Handrails shall be continuous the full length of the flight or ramp. They cannot be interrupted by newel posts, except at a turn. They shall start at least directly above the top riser, and extend to at least the top of the lowest riser. The most dangerous places on stairways, where people are the most likely to trip, are at the top and bottom. Having a handrail extend beyond the end of a stair or ramp provides a great deal of extra safety and is required on ramps. See Figures A.2. and C.2. Figure A.1 Handrail height and minimum length Figure A.2 handrail must extend full length from top step to bottom 34" above nosing 36" minimum clear width extending handrail at top and bottom improves safety www.seattle.gov/dpd 700 5th Avenue, Suite 2000 P.O. Box 34019 Seattle, WA 98124-4019 (206) 684-8600 Printed on totally chlorine free paper made with 100% post-consumer fiber

DPD Tip #319 Getting a Grip on Handrails page 2 Handrail configuration The ends of the handrails must either be returned, or end in safety terminals. (A return, for example, is where the end of the handrail turns into the adjacent wall.) These returns and safety stops prevent items such as sleeves, packages or briefcases from getting caught by the ends of the rail, or prevent the end of the rail from poking someone approaching the rail. At the lowest tread, a newel post, volute, turnout or starting easing is permitted in the handrail. See Figures B.1 and A.2. Figure B.1 SRC Section R311.5.6.2 Handrail grip size The handrail must be easily grasped. To meet code, a handrail that is round in cross section must be between 1¼ to 2 inches in diameter. If a handrail is not round, it must provide an equivalent surface that is easily grasped. There are two alternate types: Handrails with a perimeter dimension between 4 and 6¼ inches, with a maximum cross section of 2¼ inches. Handrails with a perimeter dimension greater than 6¼ inches must have a graspable finger recess area. For specific dimensions of this recess, see SRC Section R311.5.6.3.2. See Figure E (pg. 5) for some acceptable handrail profiles. Newel post at bottom may be over lowest tread Handrail Balustrade Clearance The handrail must also be far enough away from the wall so it can be easily grasped. The minimum clear distance is 1½ inches between the handrail and the wall. Projects Under the Seattle Building Code (Section 1009.11 Handrails) Newel post edge may be at landing nose Figure B.2 SBC Section 1009.11.5 1 tread Down Projects that are not single family houses, duplexes or townhouses (3 or fewer stories) are governed by the Seattle Building Code (SBC) and have slightly different requirements. (Residential units in larger buildings are also under the SBC.) NUMBER OF HANDRAILS Generally, all stairs and ramps for projects falling under the SBC are required to have handrails on both sides. Below are the exceptions: NO HANDRAILS are required in the following situations: Inside any dwelling or sleeping unit with only one riser elevation change (R2 or R3 classifications) At each residence (R3 classification) that has only one riser change at an egress or entrance door landing 12" On decks, patios and walkways with only one riser elevation change, provided there is an area equivalent to the required landing size on each side of the riser On ramps with a rise of 6 inches or less ONE HANDRAIL is sufficient for: Handrail must be continuous on stair runs Stairs within an individual dwelling unit Spiral stairs

DPD Tip #319 Getting a Grip on Handrails page 3 MORE THAN TWO HANDRAILS The code specifies that every part of the required width of a stair or ramp be within 30 inches of a handrail. Below is a chart showing when intermediate handrails are required, and how many. Remember, it is the required width of a stair or ramp that matters, not the actual width. Figure C Handrail extensions and allowable mounting heights 1 tread minimum 12" minimum at top # of intermediate Required egress width handrails required less than 5 feet 0 between 5 feet up to 10 feet 1 between 10 feet up to 15 feet 2 between 15 feet up to 20 feet 3 between 20 feet up to 25 feet 4 between 25 feet up to 30 feet 5 Figure C.1 - Stair 34" above nosing A 20-foot wide stair could have only two handrails, if the required width was only 60 inches. The handrails must be located on the most used path of travel on a stair. Designers can always place extra handrails if safety warrants it. See Figure D (pg. 4) for some options on how to place multiple handrails. HANDRAIL HEIGHT, LENGTH, AND SHAPE Handrails must be easy to grasp, be at a comfortable and safe height, and extend beyond the ends of stairs and ramps for extra safety. They must also be continuous along a stairway or ramp. Length Handrails must be continuous along the length of a stair. Handrails must also be continuous between flights that is, they cannot stop and start again between adjacent stair runs. See Figure B.2 (pg. 2). Exception Handrails on stairs that are not a required means of egress are not required to be continuous. Mounting Height The handrail must be mounted with the top of the rail between 34 and 38 inches above the nosing of the stair tread, or above the walking surface of the ramp. See Figure C. Extensions The most dangerous places on stairways and ramps, where people are the most likely to trip, are at the top and bottom. Having a handrail extend beyond the end of a stair or ramp is very important for this reason. The handrails must extend at least 12 inches beyond the top riser, and a minimum of 12 inches one tread beyond the bottom riser. The extensions must return. See Figure C. 12" minimum 12" minimum Figure C.2 - Ramp 34" above ramp Exceptions Handrails in dwelling units not required to be accessible for people with disabilities are not required to have extensions. Stairways that are not required means of egress also do not require extensions. Safety Stops and Returns The ends of the handrails must either be returned or end in newel posts or safety terminals. A newel post can only be used on the lowest point of the handrail (A return is where the end of the handrail turns into the adjacent wall or turns back on itself.) These returns and safety stops prevent items such as sleeves, packages or briefcases from getting caught by the ends of the rail, or prevent the end of the rail from poking someone approaching the rail. Exceptions Handrails in dwelling units are permitted to have a newel post at a landing as well as at the lowest tread.

DPD Tip #319 Getting a Grip on Handrails page 4 Size and Shape of Handrails The size and shape of handrails must be easily graspable. If the handgrip is too large, too small, or too close to the wall, if will not be effective. A clear space of at least 1½ inches is required between the handrail and the wall. There can be a projection of up to 4½ inches below each handrail into the required stair or ramp width. See Figure D. To meet code, a handrail that is round in cross section must be from 1¼ to 2 inches in diameter. If a handrail is not round, it must have a perimeter dimension from 4 to 6¼ inches, with a maximum diameter thickness of 2¼ inches. All edges must be eased with a minimum radius of 1/100th inch. See Figure E (pg. 5) for some acceptable handrail profiles. Projections into Stairs and Ramps The code requires ramps and stairs to be specific widths so that there is enough room for people to leave quickly in case of an emergency. This width must be clear, and free from obstructions such as door swings, posts, columns and protrusions. These features could get in the way of people trying to leave the building. The code allows handrails to project into this required width by a small amount. In general, a handrail can extend into the required width by a maximum of 4½ inches on each side of the stair or ramp. Handrails generally cannot protrude into the required width of an intersecting corridor or other passageway. In an existing building having new handrails installed, the building official may allow the handrail extensions to be omitted if they would reduce the required width or compromise safety in other ways. The designer should check with the plans examiner or building inspector before planning any projection into a passageway. See Figure F (pg. 5). Figure D There are several different options for placing handrails on a stair depending on the calculated exit width and most probable path of travel. Example: 120" required; 120" provided Example: Calculated required exit Width = 180" Monumental stair width = 300" 120" required width (all 30" from handrails) 60" 60" 60" 60" 30" 120" not required for exiting 30" most direct route required exit width calculation 60" + 60" + 30" + 30" = 180" => okay

DPD Tip #319 Getting a Grip on Handrails page 5 Figure E.1 Figure F Exemption for handrail extensions where safety is compromised SUMMARY max. max. Handrails are meant to provide a safe and practical aid to those using stairways and ramps. Effective handrails have an easily grasped size and shape, are mounted at a comfortable height, and are available along the entire length of a stair. They extend beyond the stair or ramp at the crucial top and bottom in nonresidential buildings and buildings containing several residences. The handrails are also sufficient enough in number to make users feel they can be easily grasped from all points. The codes list the minimum standards for handrails, but good design often provides more than the minimum, to make users safe and secure. Figure E.2 required stair width Relevant building code sections include the Seattle Residential Code (SRC 2003) - Section R311.5.6 Handrails; Section R311.5.6.3 Handgrip, for single family, duplex, and townhouses; and Seattle Building Code (SBC 2003) - Section 1009.11 (1 through 5) Handrails; Section 1010 Handrails (ramps). clear from wall max. offset from wall Access to Information Links to electronic versions of DPD Tips, Director's Rules, and the Seattle Municipal Code are available on the "Tools & Resources" page of our website at www.seattle.gov/dpd. Paper copies of these documents, as well as additional regulations, are available from our Public Resource Center, located on the 20th floor of Seattle Municipal Tower at 700 Fifth Ave. in downtown Seattle, (206) 684-8467.