Technical Report by Peter Guenther and Charles D. Keeling Carbon Dioxide Research Group Scripps Institution of Oceanography La Jolla, CA

Similar documents
Methods Used in Measuring Surface Seawater pco 2 Aboard RVIB Nathaniel B. Palmer

The Production of Methane and Nitrous Oxide Gas Standards for SCOR Working Group #143

Chapter 10 Gases. Characteristics of Gases. Pressure. The Gas Laws. The Ideal-Gas Equation. Applications of the Ideal-Gas Equation

Kinetic-Molecular Theory

2 Chlorouorocarbons, 3 He-tritium and Small Volume Radiocarbon{July CFC Standards During WOCE, eorts should be made to insure that the standa

CHEM 1211 Gases-Part 1 Worksheet 4-2. Name(s):

ISO INTERNATIONAL STANDARD

Chapter 13 Fluids. Copyright 2009 Pearson Education, Inc.

Chem 110 General Principles of Chemistry

Taro Takahashi, Colm Sweeney, S. C. Sutherland. Lamont-Doherty Earth Observatory of Columbia University Palisades, NY

F:\Ships\lmgould\2003\lmg03_2\surface\LMG03_2_data_report.doc Page 107/27/17 12:55 PM

Gas Laws. Introduction

Three Columns Gas Chromatograph Analysis Using Correlation between Component's Molecular Weight and Its Response Factor

LAB 06 Organismal Respiration

METHOD 3C - DETERMINATION OF CARBON DIOXIDE, METHANE, NITROGEN, AND OXYGEN FROM STATIONARY SOURCES

Lecture Handout 5: Gases (Online Text Chapter 6)

Part 1 - Data Processing and Quality Control.

F:\Ships\NBPalmer\2003\nbp03_4a\surface\NBP03_4A_data_report.doc

F:\Ships\NBPalmer\2002\nbp02_2\surface\NBP02_2_data_report.doc Page 104/25/17 3:33 PM

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

What factors affect the rate of cellular respiration in multicellular organisms?

B. As the gas particles move and strike a surface, they push on that surface 1. If we could measure the total amount of force exerted by gas

Part 1 - Data Processing and Quality Control.

REPORT OF UNDERWAY pco 2 MEASUREMENTS IN SURFACE WATERS AND THE ATMOSPHERE DURING February - March (RVIB Nathaniel B. Palmer Cruise 01/2)

Gases and Pressure. Main Ideas

SCRIPPS REFERENCE GAS CALI3RATING SYSTErt FOR CAR~ON DIOXIDE IN AIR STANDARDS: REVISION OF 1981

ISO Vacuum gauges Calibration by direct comparison with a reference gauge

Part 1 - Data Processing and Quality Control.

REPORT OF UNDERWAY pco 2 MEASUREMENTS IN SURFACE WATERS AND THE ATMOSPHERE DURING July (RVIB Nathaniel B. Palmer Cruise 00/5)

Chapter 5. Nov 6 1:02 PM

World of Chemistry Notes for Students [Chapter 13, page 1] Chapter 13 Gases

Chapter 10 Fluids. Which has a greater density? Ch 10: Problem 5. Ch 10: Problem Phases of Matter Density and Specific Gravity

Name Chemistry Pre-AP

Unit 9 Packet: Gas Laws Introduction to Gas Laws Notes:

F:\Ships\NBPalmer\2001\nbp01_4\surface\NBP01_4_data_report.doc Page 106/02/15 11:21 AM

QC for Hydrographic Data GEOSECS to GO-SHIP. Susan M. Becker Scripps Institution of Oceanography Oceanographic Data Facility

Part 1 - Data Processing and Quality Control.

Lecture Presentation. Chapter 10. Gases. John D. Bookstaver St. Charles Community College Cottleville, MO Pearson Education, Inc.

Part 1 - Data Processing and Quality Control.

F:\Ships\NBPalmer\2002\nbp02_1\surface\NBP02_1_data_report.doc Page 103/19/15 11:16 AM

Section 8: Gases. The following maps the videos in this section to the Texas Essential Knowledge and Skills for Science TAC (c).

A SIMPLE, ACCURATE METHOD OF ESTIMATING CARBON MONOXIDE IN BLOOD

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Chapter 13 Gases, Vapors, Liquids, and Solids

Supporting Information for Micro-Collection of. Gases in a Capillary Tube: Preservation of Spatial

Part 1 - Data Processing and Quality Control.

General Chemistry II CHEM 116

How is pressure handled when we have a mixture of gases?

Part 1 - Data Processing and Quality Control.

Chapter 10: Gases. Characteristics of Gases

EN ISO/IEC Technical Requirements

Section 10-1: The Kinetic-Molecular Theory of Matter. 1) How does the word kinetic apply to particles of matter?

Part 1 - Data Processing and Quality Control.

INTERNATIONAL STANDARD

Chapter 5: Gases 5.1 Pressure Why study gases? An understanding of real world phenomena. An understanding of how science works.

F:\Ships\NBPalmer\2001\nbp01_3\surface\NBP01_3_data_report.doc Page 104/26/17 4:13 PM

The analysis of complex multicomponent

REPORT OF UNDERWAY pco 2 MEASUREMENTS IN SURFACE WATERS AND THE ATMOSPHERE DURING February - April RVIB Nathaniel B. Palmer Cruise 03/4

Part 1 - Data Processing and Quality Control.

Gas Laws Chapter 14. Complete the following pressure conversion. Be sure to show how units cancel.

CORESTA RECOMMENDED METHOD N 6

Organic Elemental Analysis Series II Nitrogen Analyzer. proven performance. reliable results

States of Matter Review

Legendre et al Appendices and Supplements, p. 1

CORESTA RECOMMENDED METHOD Nº 67

Basic Concepts of Chemistry Notes for Students [Chapter 10, page 1] D J Weinkauff - Nerinx Hall High School. Chapter 10 Gases

Density and Specific Gravity

Central scientific research automobile and automotive engine institute

Analysis of a KClO3 Mixture and Determination of R

CONCENTRATION CARBON DIOXIDE

Retention Time Locking: Concepts and Applications. Application

Preparation of high precision standards (with ± 1 ppm) using a gravimetric method for measuring atmospheric oxygen

Applied Physics Topics 2

Kinetic Molecular Theory imaginary Assumptions of Kinetic Molecular Theory: Problems with KMT:

Gas Pressure. Pressure is the force exerted per unit area by gas molecules as they strike the surfaces around them.

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

CALCULATING THE SPEED OF SOUND IN NATURAL GAS USING AGA REPORT NO Walnut Lake Rd th Street Houston TX Garner, IA 50438

(NIST Special Publication )

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Date of Shipment: Xxxxx 00, 20xx 3402c National Institute of Advanced Industrial Science and Technology National Metrology Institute of

COOMET TECHNICAL COMMITTEE 1.8 PHYSICAL CHEMISTRY

Chapter 13. Gases. Copyright Cengage Learning. All rights reserved 1

Honors Chemistry - Problem Set Chapter 13 Classify each of these statements as always true, AT; sometimes true, ST; or never true, NT.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

KNOWN: Mass, pressure, temperature, and specific volume of water vapor.

PROPERTIES OF GASES. [MH5; Ch 5, (only)]

Chemistry HP Unit 6 Gases. Learning Targets (Your exam at the end of Unit 6 will assess the following:) 6. Gases

Pressure of the atmosphere varies with elevation and weather conditions. Barometer- device used to measure atmospheric pressure.

Completed ALL 2 Warm-up IC Kinetic Molecular Theory Notes. Kinetic Molecular Theory and Pressure Worksheet

CHAPTER 31 IDEAL GAS LAWS

ISO INTERNATIONAL STANDARD

Gas mixtures. Individual solutions specifically for your application

The Preparation of Low Concentration Hydrogen Sulfide Standards Gulf Coast Conference September 12, 2002 Galveston, TX Paper 050,12:45 pm Moody F

Under pressure pushing down

METROLOGICAL ASSURENCE OF O3, CO2, CH4 AND CO CONTROL IN ATMOSPHERE

Intertek Testing Services Taiwan Ltd.

Heat Capacity Ratio of Gases. Kaveendi Chandrasiri Office Hrs: Thursday. 11 a.m., Beaupre 305

Chemistry 12 Notes on Graphs Involving LeChatelier s Principle

CHEMISTRY - CLUTCH CH.5 - GASES.

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Transcription:

Manometric AnaIyses of NOAA Primary C02 Reference Gas Standards at SIO Technical Report by Peter Guenther and Charles D. Keeling Carbon Dioxide Research Group Scripps Institution of Oceanography La Jolla, CA 92093-0244 Submitted to Climate Monitoring and Diagnostics Laboratory National Oceanic and Atmospheric Administration Boulder, CO 80303 March 16, 2000

Introduction In March and April of 1999, the Carbon Dioxide Research Group at Scripps Institution of Oceanography (SIO) made analyses on its constant-volume mercury-column manometer (CMM) of the C02 content in 8 primary natural air reference standards of the Climate Monitoring and Diagnostics Laboratory (CMDL) of the National Oceanic and Atmospheric Administration. These 8 gas mixtures are a subset of 15 primary reference gas standards whose C02 contents have been determined on the CMDL manometer. The CMDL became the Central COz Calibrating Laboratory (CCL) of the World hileteorological Organization in 1995. The set of 15 reference gases constitutes the calibration standard for international measurements of atmospheric C02. The intercomparison exercise was designed to compare closely the manometric calibration of CMDL with that of SIO, the designated CCL prior to 1995. The Data: Table 1 The results of each measurement, in mole fraction (X) of C02, are listed in Table 1. (For a detailed description of the methods of measurement and calcula- tion of the results from the original manometric data, see Guenther and Keeling (19811). Calculation of the mole fraction of C02 has until now been based provi- sionally on a manometric volume ratio (VR), V5000ce/V4cc, determined in 1974 to be 1320.61. "Individual Determinations," in Table 1, represent replicate measure- ments (usually two) of the C02 gas fraction in the small volume chamber (nomi- nally 4 cc) of the manometer combined with a single measurement of the total gas fraction in the large volume chamber (nominally 5000 cc) of the manometer. The column in Table 1 labeled "Run Difference" lists the difference between two independent measurements of each reference gas, determined for two separate ali- quots of total gas drawn from the reference gas cylinder. In cases where there are

more than two runs, the differences between successive runs are listed. The column labeled "Overall Average" lists the average of all measurements, usually four, for a particular reference gas. In 1998 the primary reference gas standards of SIO were measured on the CMM [Keeling et al, 2000]. Based upon a hypothesis that the mole fractions of CO, of the SIO primary reference gases have, on average, not drifted, a provisional 1998 VR of 1322.30 was assigned. The column in Table 1 labeled "Volume Adjusted" shows the CMDL gas results calculated using the VR assigned in 1998. The natural air reference gases of both CMDL and SIO contain approximately the normal atmospheric abundance of N20, i.e. approximately 1 part in 1000 of the CO, abundance. This N20 gas is included in the manometric measurement of the extracted C02 gas. The mole fraction of N20 in each reference gas, determined by gas chromatography in the laboratory of R.F. Weiss at SIO, is listed on Table 1 in the column labeled "N20." The last column in Table 1, labeled "1999" value, lists the C02 mole fraction with the N20 fraction subtracted. Imprecision of the Data The data in Table 1 include two sets of replicate measurements. The first replicate is of individual determinations of the C02 gas fraction on the small manometer combined with a single total gas fraction measurement, all shown on one line. The second replicate is of completely independent calibrations (termed "Runs" in Table I), shown on succeeding lines. Estimates of the imprecision of the data set have been made from both kinds of replicate data. The sample standard deviation, s;, of an individual 4 cc volume measurement, as calculated from the 41 individual determinations of 20 runs, is 0.087 ppm, a dispersion slightly higher than the previous performance (repeatability) of the CMM, arising mostly

from errors in the 4 cc volume measurements. A similar calculation of the si from the replicate run data estimates the imprecision of an ent,ire calibration of a specific gas mixture including the gas transfer and extraction of the C02 fraction. The resultant sj from the data on 18 selected "good" runs of the set of 8 reference gases is 0.192 ppm. This sc is approximately three times greater than previous performance of the CMM. For comparison, the si calculated from the 50 runs of SIO primary reference gases in 1998 was 0.056 ppm. The high dispersion was primarily caused by the analyses of Reference Gases 103 and 105. In both cases, a run had to be rejected due to a blunder that resulted in incomplete extraction of C02 from the aliquot. In both cases a total of three "good" runs were eventually made, but with the result that no two of the runs were in satisfactory agreement. The si for a run improves to.0.139 ppm if the results for gas 103 are rejected. Discussion: Table 2 The CMDL and $10 manometric calibration data are compared in Table 2. The result for Reference Gas 103 is about two times the standard deviation away from the average. Because of the difficulties in reproducibility discussed above, it seems justifiable to reject the results for Reference Gas 103. The SIO results on average are then lower than the CX4DL calibration data by 0.17 ppm (si=0.14 ppm) for the remaining 7 gases. This average difference between the CMDL and SIO manometric calibration data may be due to an incorrectly assigned 4 cc chamber volume in the SIO manometer. Based on the hypothesis that the SIO primary reference gases have not drifted, the volume of the 4 cc chamber for 1998 was determined to be 3,7927 cc. This assignment disagrees with a direct calibration, using 5 calibrated plenums, made in December 1998 and January 1999 yielding 3.7953 cc [Keeling et al,

20001. Perhaps the effective volume of the SIO small manometer changed between mid-1998, when the SIO primary reference gases were measured manometrically, and the spring of 1999, when the CMDL reference gases were measured. If we use the CMDL manometric values for the seven gases (rejecting Reference Gas 103) to determine the effective VR of the SIO manometer, we find 1321.70 (si=0.44). Using the same 5000 cc chamber volume (5015.09 cc), this VR implies a 4 cc chamber volume of 3.7944 cc. If the 1998-1999 volume of 3.7953 cc derived from plenums is used to calculate the CMDL reference gases, the average difference between SIO and CMDL for the seven gases becomes 0.08 ppm, the SIO values higher. The results report.ed here should be considered provisional pending further measurements. \Ve have approximately 500 C02 samples stored in breakoff tubes that have been measured on the mercury manometer between 1990 and its shutdown in April 1999. This period of time encompasses the period during which measurements of the SIO primzry reference gases imply that the effective volume of the 4 cc chamber was shifting to lower values. We plan to run a subset of the saved samples on our Ruska electronic manometer to determine whether the shifting 4 cc chamber hypot.hesis is supported. There is also a small possibility that the mercury manometer itself may be placed back into operation sometime in the future, and that further calibrations may provide evidence bearing on its performance in 1998 and 1999.

References Guenther, P. R. and C. D. Keeling, Manometer Report 111: Manometric Calibrations of Primary C02 Reference Gases During 1974, SIO Reference Series No. 81-19, Scripps Institution of Oceanography, La Jolla, CA, 71 pp., 1981. Keeljng, C. D., P. R. Guenther, G. Emanuele, A. Bollenbacher, and D. J. Moss, Scripps Reference Gas Calibration System for Carbon Dioxide-in-air Standards: Revision of 1999, in preparation, SIO Reference Series, Scripps hstitution of Oceanography, La Jolla, CA, 2000.

m 0 t-w t- n Q Q O m 9 2 q * 5 a 9 C!???? a 0

Table 2. NOAA and SIO Manometric Analyses of NOAA Primary Reference Gas Standards Cylinder No. * Rejected X(N0AA) (PP~) X (SIO) (PP~) 246.47 323.86 352.72 360.70 369.32 381.30 395.93 452.96 Av. of 8-0.23 Si 0.21 Av. of 7* -0.17 Si 0.14