TGA200 Trace Gas Analyzer Overview 9/11

Similar documents
TGA100A Trace Gas Analyzer Overview

PWC100 Present Weather Sensor Calibrator Revision: 3/12

PWC100 Present Weather Sensor Calibrator

INSTRUCTION MANUAL. CS115 Barometric Pressure Sensor 3/03. Copyright (c) Campbell Scientific, Inc.

Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision: 12/06

TGA100 TRACE GAS ANALYZER USER AND REFERENCE MANUAL

INSTRUCTION MANUAL. Using the CS400/CS405 (KPSI Series 169/173) Submersible Pressure Transducer with Campbell Scientific Dataloggers.

Campbell Scientific CS511-L Sensorex Dissolved Oxygen Probe Revision: 6/12

Overview. Front Panel: Keypad and Display

52202/52203 Tipping Bucket Raingauge

INSTRUCTION MANUAL. CRS451/CRS456 Submersible Water-Level Recording Sensor Revision: 12/15. Copyright Campbell Scientific, Inc.

CS431 Submersible Pressure Transducer Revision: 3/09

CS470/CS471 Compact Bubbler System Revision: 7/11

USER MANUAL. CRS451/CRS456 Submersible Water-Level Recording Sensor. Issued:

In Vivo Scientific, LLC INSTRUCTION MANUAL

CS115 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

PM105 PRESSURE METER USER S MANUAL

UNIVERSAL MASK TEST SYSTEM

TR Electronic Pressure Regulator. User s Manual

Laser Spectrometers for Online Moisture Measurement in Natural Gas. Ken Soleyn GE M&C

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

FOURIER TRANSFORM INFRARED SPECTROSCOPY

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

MODEL CALIBRATION GAS DELIVERY SYSTEM

Digital Vacuum Regulator

Columbus Instruments

Your local gas generation partner. Precision series Modular gas generation solution for GC.

Purpose and Scope: Responsibilities: Warnings and precautions: Background Beers law

Your local gas generation partner. Precision series Modular gas generation solution for GC.

92831 TEL: (714) FAX:

Basic Nitriding Sampling System Hydrogen Analyzer with Calculated % DA, % NH 3, and K N Values. Operations Manual

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

Your local gas generation partner. Precision series Modular gas generation solution for GC.

FTIR Users Group Meeting FTIR development

ASDX Series Silicon Pressure Sensors

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

Geotech Portable Bladder Pumps Installation and Operation Manual

CSA Sample Draw Aspirator Adapter Operator s Manual

MATRIX-MG Series. Innovation with Integrity. Automated High-Performance Gas Analyzers FT-IR

INSTRUCTION MANUAL. Tipping Bucket Rain Gauge. Issued: Copyright 2017 Campbell Scientific Ltd. CSL 1194

Discovery HP-TGA 75/750. Site Preparation Guide

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS

For Models: 55A00-2 (HAI UPB 1500W Wall Switch Dimmer) 55A00-3 (HAI UPB 2400W Wall Switch Dimmer) 37A00-1 (HAI Auxiliary Switch)

INSTRUCTION MANUAL. CS106 Barometric Pressure Sensor Revision: 4/17. Copyright Campbell Scientific, Inc.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

HCL MONITORING. ICAC MARAMA WORKSHOP May 18-19th, Presented by: Ty Smith. CEMTEK

GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL

RAM 4021 Operation Manual

92831 TEL: (714) FAX:

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

MODEL 100 NITROGEN INFLATION CART

User s Guide Temperature Sensor Converter TSC-599

Mitos Fluika Pressure and Vacuum Pumps Datasheet

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

Model DPC3500 Continuous Low Range Dew Point Analyzer. Operations Manual

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

GasSense NDIR User Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RAM 4021-DPX Operation Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual

CSBUOY-DT INSTRUCTION MANUAL

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Alphasense Application Note AAN NDIR: Gas Concentration Calculation Overview

SC-888 Instructions. The following illustration provides the operation of pushbuttons and location of indicators for the Robic SC-888.

BULLETIN E485B. Poppet Valve Construction Customized Solutions Plug-and-Play Design. Subject to technical modifications.

ENVIRONMENTAL INSTRUMENTS, LLC

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Geotech 1.66 Auto-Reclaimer

Geotech 1.66 Auto-Reclaimer Installation and Operation

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Agilent Auxiliary Gas Module AGM 2. User s Guide

TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual

Digital Vacuum Regulator

Series Environmental Chambers

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

Auto-Zero Calibration Technique for Pressure Sensors

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

P5523. Users Manual. Liquid to Gas Separator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RGC-IR Remote Gas Calibrator for IR400

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Varian 310

Laser Gas Analyzer LG2000. The Laser Technologies

DEEPSEA. Power & Light. Micro SeaLaser. Operator s Manual Ruffin Road San Diego, CA USA T: (858) F: (858)

EXPERIMENT XI. Careful!! Improper handling of the vacuum line may result in the release of SO 2 which is an irritating and suffocating gas.

Advanced Test Equipment Rentals ATEC (2832)

HLM-2000-TX Gas Transmitter User Manual

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Measuring Sound Speed in Gas Mixtures Using a Photoacoustic Generator

SPS-5. Rate Computing Scale. Operation Manual

HAI UPB Wall Switch and Auxiliary Switch Installation and Operating Instructions

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

CALIBRATION KIT. Instruction Manual

Transcription:

TGA200 Trace Gas Analyzer Overview 9/11 C o p y r i g h t 2 0 1 1 C a m p b e l l S c i e n t i f i c, I n c.

Warranty PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. ( Campbell ) to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless otherwise specified on the corresponding Campbell invoice. Batteries, fine-wire thermocouples, desiccant, and other consumables have no warranty. Campbell's obligation under this warranty is limited to repairing or replacing (at Campbell's option) defective products, which shall be the sole and exclusive remedy under this warranty. The customer shall assume all costs of removing, reinstalling, and shipping defective products to Campbell. Campbell will return such products by surface carrier prepaid within the continental United States of America. To all other locations, Campbell will return such products best way CIP (Port of Entry) INCOTERM 2010, prepaid. This warranty shall not apply to any Campbell products which have been subjected to modification, misuse, neglect, improper service, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied. The warranty for installation services performed by Campbell such as programming to customer specifications, electrical connections to products manufactured by Campbell, and product specific training, is part of Campbell s product warranty. CAMPBELL EXPRESSLY DISCLAIMS AND EXCLUDES ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Campbell is not liable for any special, indirect, incidental, and/or consequential damages.

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit www.campbellsci.com to determine which Campbell Scientific company serves your country. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) 227-9000. After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. Campbell Scientific's shipping address is: CAMPBELL SCIENTIFIC, INC. RMA# 815 West 1800 North Logan, Utah 84321-1784 For all returns, the customer must fill out a "Statement of Product Cleanliness and Decontamination" form and comply with the requirements specified in it. The form is available from our web site at www.campbellsci.com/repair. A completed form must be either emailed to repair@campbellsci.com or faxed to (435) 227-9106. Campbell Scientific is unable to process any returns until we receive this form. If the form is not received within three days of product receipt or is incomplete, the product will be returned to the customer at the customer's expense. Campbell Scientific reserves the right to refuse service on products that were exposed to contaminants that may cause health or safety concerns for our employees.

TGA200 Overview Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to specific sections. 1. System Components...2 2. Theory of Operation...3 2.1 Optical System...3 2.2 Laser Scan Sequence...4 2.3 Concentration Calculation...5 3. Trace Gas Species Selection...5 4. Multiple Ramp Mode...6 5. User Interface...6 6. Specifications...7 6.1 Measurement Noise...7 6.2 TGA200 Frequency Response...8 6.3 Physical Specifications...10 Figures Tables 1-1. TGA200 system components...2 2-1. Schematic diagram of TGA200 optical system...3 2-2. TGA200 laser scan sequence...4 5-1. Real-time graphics screen...6 6-1. Concentration time series showing response of TGA200...9 6-2. Frequency response of the TGA200...9 6-1. Typical Concentration Measurement Noise...7 6-2. Typical Concentration Measurement Noise for Multiple Scan Lasers...7 6-3. Typical Isotope Ratio Measurement Noise...8 i

TGA200 Trace Gas Analyzer Overview The TGA200 Trace Gas Analyzer measures trace gas concentration in an air sample using tunable diode laser absorption spectroscopy (TDLAS). This technique provides high sensitivity, speed, and selectivity. The TGA200 is a rugged, portable instrument designed for use in the field. It can measure one of a large number of gases by choosing appropriate lasers and detectors. 1

TGA200 Trace Gas Analyzer Overview 1. System Components Figure 1-1 illustrates the main system components as well as additional equipment needed to operate the TGA200. These system components include: TGA200 Analyzer Sample intake (15838 shown): Filters the air sample and controls its flow rate. Sample pump (RB0021-L shown): Pulls the air sample and reference gas through the analyzer at a low pressure. Reference gas: Tank of reference gas, with pressure regulator (supplied by user). Reference gas connection (15837 shown): Flow meter, needle valve, and tubing to connect the reference gas to the analyzer. Datalogger (CR3000 shown) Computer (supplied by user): Used to check status and set parameters in the TGA200. FIGURE 1-1. TGA200 system components 2

TGA200 Trace Gas Analyzer Overview 2. Theory of Operation 2.1 Optical System The TGA200 optical system is shown schematically in Figure 2-1. The optical source is a lead-salt tunable diode laser that operates between 80 and 140 K, depending on the individual laser. The TGA200 LN2 Laser Dewar includes a laser mount that can accommodate one or two lasers. The LN2 Laser Dewar mounts inside the analyzer enclosure. It holds 14.5 liters of liquid nitrogen and must be refilled once per week. FIGURE 2-1. Schematic diagram of TGA200 optical system The laser is simultaneously temperature and current controlled to produce a linear wavelength scan centered on a selected absorption line of the trace gas. A beam splitter allows most of the energy from the laser to pass through a 1.5 m sample cell, where it is absorbed proportional to the concentration of the target gas. A lens at the outlet of the sample cell focuses the beam onto the sample detector. The portion of the beam that is reflected by the beamsplitter passes through a reference cell similar to the sample cell and is focused on the reference detector. A prepared reference gas having a known concentration of the target gas flows through the reference cell. The reference signal provides a template for the spectral shape of the absorption line, allowing the concentration to be derived independent of the temperature or pressure of the sample gas or the spectral positions of the scan samples. The reference signal also provides feedback for a digital control algorithm to maintain the center of the spectral scan at the center of the absorption line. The simple optical design avoids the alignment problems associated with multiple-path absorption cells. The number of reflective surfaces is minimized to reduce errors caused by Fabry-Perot interference. 3

TGA200 Trace Gas Analyzer Overview 2.2 Laser Scan Sequence The laser is operated using a scan sequence that includes three phases: the modulation phase, the zero-current phase, and the high-current phase, as illustrated in Figure 2-2. The modulation phase performs the actual spectral scan. During this phase the laser current is increased linearly over a small range (typically ±0.5 to 1 ma). The laser s emission wavenumber depends on its current. Therefore, the laser s emission is scanned over a small range of frequencies (typically ±0.03 to 0.06 cm -1 ). During the zero-current phase, the laser current is set to a value below the laser s emission threshold. Zero signifies that the laser emits no optical power; it does not mean the current is zero. The zero-current phase is used to measure the detector s dark response, i.e., the response with no laser signal. The reduced current during the zero-current phase dissipates less heat in the laser, causing it to cool slightly. The laser s emission frequency depends on its temperature as well as its current. Therefore, the temperature perturbation caused by reduced current during the zero-current phase introduces a perturbation in the laser s emission frequency. During the high-current phase, the laser current is increased above its value during the modulation phase to replace the heat lost during the zero-current phase. This stabilizes the laser temperature quickly, minimizing the effect of the temperature perturbation. The entire scan sequence is repeated every 2 ms. Each scan is processed to give a concentration measurement every 2 ms (500 Hz sample rate). High-Current Phase (Temperature Stabilization) Modulation Phase (Spectral Scan) Zero-Current Phase (Laser (Laser Off) Off) Laser Current Omitted Used in Calculation Detector Response 2 ms FIGURE 2-2. TGA200 laser scan sequence 4

TGA200 Trace Gas Analyzer Overview 2.3 Concentration Calculation The reference and sample detector signals are digitized, corrected for detector offset and nonlinearity, and converted to absorbance. A linear regression of sample absorbance vs. reference absorbance gives the ratio of sample absorbance to reference absorbance. The assumption that temperature and pressure are the same for the sample and reference gases is fundamental to the design of the TGA200. It allows the concentration of the sample, C S, to be calculated by CRLRD C S = L S Where C R = concentration of reference gas, ppm L R = length of the reference cell, cm L S = length of the sample cell, cm D = ratio of sample to reference absorbance 3. Trace Gas Species Selection The TGA200 can measure gases with absorption lines in the 3 to 10 micron range by selecting appropriate lasers, detectors, and reference gas. Lead-salt tunable diode lasers have a limited tuning range, typically 1 to 3 cm -1 within a continuous tuning mode. In some cases more than one gas can be measured with the same laser, but usually each gas requires its own laser. The laser dewar has two laser positions available (four with an optional second laser mount), allowing selection of up to four different species by rotating the dewar, installing the corresponding cable, and performing a simple optical realignment. The standard detectors used in the TGA200 are Peltier cooled and operate at wavelengths up to 5 microns. These detectors are used for most gases of interest, including nitrous oxide (N 2 O), methane (CH 4 ), and carbon dioxide (CO 2 ). Some gases, such as ammonia (NH 3 ), have the strongest absorption lines at longer wavelengths and require the optional long-wavelength, liquid nitrogen-cooled detectors. These detectors operate to wavelengths beyond 10 microns. The detector dewars have a liquid nitrogen capacity of 6.0 liters and must be filled twice per week. A prepared reference gas having a known concentration of the target gas must flow through the reference cell. The beam splitter directs a small fraction of the laser power through the reference cell to the reference detector. This gives a reference signal proportional to the laser power, with the spectral absorption signature of the reference gas. The reference signal provides a template for the spectral shape of the absorption feature, allowing the concentration to be derived without measuring the temperature or pressure of the sample gas, or the spectral positions of the scan samples. 5

TGA200 Trace Gas Analyzer Overview 4. Multiple Ramp Mode 5. User Interface The TGA200 can be configured to measure two or three gases simultaneously by alternating the spectral scan wavelength between nearby absorption lines. This technique requires that the absorption lines be very close together (within about 1 cm -1 ), so it can be used only in very specific cases. The multiple ramp mode is used to measure isotope ratios in carbon dioxide by tuning each ramp to a different isotopolog. The multiple ramp mode may also be used to measure some other pairs of gases, such as nitrous oxide and carbon dioxide or nitrous oxide and methane, but the measurement noise will generally be higher than if a single gas is measured. For measurements of a single gas, the laser wavelength is chosen for the strongest absorption lines of that gas. Choosing a laser that can measure two gases simultaneously involves a compromise. Weaker absorption lines must be used in order to find a line for each gas within the laser s narrow tuning range. The TGA200 includes TGA Windows software. Illustrated in Figure 5-1, TGA Windows displays data in real time, allows modification of control parameters, and saves data to the hard disk. FIGURE 5-1. Real-time graphics screen 6

TGA200 Trace Gas Analyzer Overview 6. Specifications 6.1 Measurement Noise The typical 10 Hz-concentration measurement noise, given in Table 6-1, is calculated as the square root of the Allan variance with 100 ms averaging (i.e., the two-sample standard deviation). This is comparable to the standard deviation of the 10 Hz samples calculated over a relatively short time (10 s). The typical 30-minute average gradient resolution is given as the standard deviation of the difference between two intakes, averaged over 30 minutes, assuming typical valve switching parameters. Gas TABLE 6-1. Typical Concentration Measurement Noise Wave number (cm -1 ) 10 Hz Noise (ppbv) Nitrous Oxide N 2 O 2208.575 1.5 30 Methane CH 4 3017.711 7 140 Ammonia NH 3 1065.56 6 200 30-min Gradient Resolution (pptv) The TGA200 multiple-scan mode can be used to measure suitable pairs of gases. Typical performance for some examples is given in Table 6-2. TABLE 6-2. Typical Concentration Measurement Noise for Multiple Scan Lasers Gas Nitrous Oxide and Methane Nitrous Oxide and Carbon Dioxide Wave number (cm -1 ) 10 Hz Noise (ppbv) N 2 O 1271.077 7 140 CH 4 1270.785 18 360 N 2 O 2243.110 1.8 35 CO 2 2243.585 300 6000 30-min Gradient Resolution (pptv) Typical performance for isotope ratio measurements is given in delta notation. For example, the δ 13 C for CO 2 is given by 13 R δ C = R S VPDB 1 1000 where R s is the ratio of the isotopolog concentrations measured by the TGA200 ( 13 CO 2 / 12 CO 2 ) and R VPDB is the standard isotope ratio ( 13 C/ 12 C). δ 13 C is reported in parts per thousand (per mil or ). The 10 Hz noise is the square root of the Allan variance with no averaging. The calibrated noise assumes a typical sampling scenario: two air sample intakes and two calibration samples measured in a 1-minute cycle. It is given as the standard deviation of the calibrated air sample measurements. 7

TGA200 Trace Gas Analyzer Overview Gas TABLE 6-3. Typical Isotope Ratio Measurement Noise Isotope Ratio Wavenumber (cm -1 ) 10 Hz Noise Calibrated Noise ( ) Carbon Dioxide CO 2 2293.881 0.15 ppm 0.03 ppm δ 13 C only δ 13 C 2294.481 0.5 0.1 Carbon Dioxide δ 13 C and δ 18 O CO 2 2310.686 0.5 ppm 0.1 ppm δ 13 C 2310.347 1.5 0.3 δ 18 O 2310.206 1.5 0.3 6.2 TGA200 Frequency Response There are several issues related to the frequency response of the TGA200, including measurement rate, sample rate, digital filtering, synchronicity, and flow and pressure in the sample cell. Measurement rate: 500 Hz Onboard digital filter: user-configurable Sample cell volume: 420 ml Frequency response (half-power bandwidth at 10 slpm, 20 mb): 7.5 Hz The TGA200 s frequency response was measured by quickly injecting a small amount of CO 2 into the sample flow, at the TGA200 s sample inlet. The data were sampled at 50 Hz, and the onboard digital filter was disabled. An example of the concentration time series is shown in Figure 6-1. The flow was 10 slpm and the pressure was 20 mb, for a calculated residence time of 50 ms. The width of the pulse at half-peak height is approximately 50 ms, as expected. The measured frequency response (Fourier transform of the measured pulse) is shown in Figure 6-2. The blue curve is the measured frequency response. The purple curve is a model of the frequency response. This model includes two components, shown individually in green and red. The green curve is a sync function, which is the ideal frequency response assuming no mixing of the air sample as it travels to, or through, the sample cell. The blue (measured) curve is below the green (ideal modeled) response, indicating some mixing does occur. The red curve is the frequency response of an ideal mixing volume, with a residence time (exponential time constant) of 14 ms. This residence time is chosen empirically such that the combined effect (purple curve) matches the measured response. These results and data at other flows and pressures confirm that the TGA200 s frequency response is well represented by the combination of an ideal sync function and an exponential function with time constant equal to 1/5 of the sample cell residence time. 8

TGA200 Trace Gas Analyzer Overview Concentration (ppm) Time (seconds) FIGURE 6-1. Concentration time series showing response of TGA200 Amplitude Frequency (Hz) FIGURE 6-2. Frequency response of the TGA200. The blue line is the measured response, the red line is the model response, the green line is the ideal response, and the red line is the response time of an ideal mixing volume with residence time of 14 ms. 9

TGA200 Trace Gas Analyzer Overview 6.3 Physical Specifications Length: 211 cm (83 in) Width: 47 cm (18.5 in) Height: 55 cm (21.5 in) Weight with peltier-cooled detectors: 78.6 kg (173 lb) Weight with LN2 detectors: 84.1 kg (185 lb) Power Requirements Analyzer: 90-264 Vac, 47-63 Hz, 50 W (max) 30 W (typical) Heater: 90-264 Vac, 47-63 Hz, 150 W (max) 30 W (typical) 10

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za cleroux@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 444 Thuringowa Central QLD 4812 AUSTRALIA www.campbellsci.com.au info@campbellsci.com.au Campbell Scientific do Brazil Ltda. (CSB) Rua Luisa Crapsi Orsi, 15 Butantã CEP: 005543-000 São Paulo SP BRAZIL www.campbellsci.com.br suporte@campbellsci.com.br Campbell Scientific Canada Corp. (CSC) 11564-149th Street NW Edmonton, Alberta T5M 1W7 CANADA www.campbellsci.ca dataloggers@campbellsci.ca Campbell Scientific Centro Caribe S.A. (CSCC) 300 N Cementerio, Edificio Breller Santo Domingo, Heredia 40305 COSTA RICA www.campbellsci.cc info@campbellsci.cc Campbell Scientific Ltd. (CSL) Campbell Park 80 Hathern Road Shepshed, Loughborough LE12 9GX UNITED KINGDOM www.campbellsci.co.uk sales@campbellsci.co.uk Campbell Scientific Ltd. (France) 3 Avenue de la Division Leclerc 92160 ANTONY FRANCE www.campbellsci.fr info@campbellsci.fr Campbell Scientific Spain, S. L. Avda. Pompeu Fabra 7-9, local 1 08024 Barcelona SPAIN www.campbellsci.es info@campbellsci.es Please visit www.campbellsci.com to obtain contact information for your local US or International representative.