B84G - Excelon Plus Modular System General purpose filter/regulator

Similar documents
B84G - Excelon Plus Modular System General purpose filter/regulator

R84G - Excelon Plus Modular System Pressure regulators

B74G - EXCELON Modular System General purpose filter/regulator

R18 General purpose pressure regulators

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators

F68G - Olympian Plus plug-in system General purpose filter

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

Precision and Instrument Regulators 1/4" port size

EXCELON QUIKCLAMP SYSTEM Pressure relief valves V72G, V74G - G1/4... G 3/4

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

Series K Air service units G 1/8, G 1/4

Regulators/valves Compressed air regulators Without filter

SPCH/ Blowing block

Modular Type Regulators

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

VPPC02, VPPC08 3-way proportional pressure control valve, electronic closed loop control

PARTICULATE FILTER/REGULATOR

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Air service units series K G1/8, G1/4

How to Order. Rc NPT 1/8 1/4 3/8 1/2

AIR TREATMENT H Z E 0. Air Treatment Units CHARACTERISTICS CODIFICATION KEY. Filter. Ambient temperature Fluid Working pressure Max pressure Size Body

MINIATURE COMBINATION UNITS Filter/regulators and lubricators P1H - G1/8, G1/4

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Nugget 120 V14 Series

INDUSTRIAL PNEUMATICS - air treatment units. FIL filter

Series MX pressure regulators 3/

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Direct Operated Precision Regulator Modular Style. Standard Specifications

ALF400 to 900, ALT-5/-9

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (

Type 4708 Supply Pressure Regulator

KM/31000 (Stainless steel end plates) Air bellows, single acting

Type 4708 Supply Pressure Regulator

Related Products: Auto Drain Valve. Model/Specifications. Model

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Air-service devices, Series MU1

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Precision pressure regulators LRP/LRPS

Non-Return Valves T55 Series

Air preparation units

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Air service units series Y G1/4 to G1

Modular Air Combination Units

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

Nugget 120 V14 Series

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

1 8 A N D 2 8 S E R I E S

MF2M Monnier Miniature Compressed Air Filter

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

Filter-Regulator-Lubricator

FILTER REGULATOR. We produce with artistic attitude.

Symbols. Bowl type Poly bowl with bowl guard G Metal bowl without sight gauge M. Drain type 5μ Element

FR12MD FR38MD. Modular filter-regulators, suitable for compressed air FEATURES. Filter-regulator for inlet pressure up to 30 bar (435 psi).

Avenger Model 33M Installation & Operation Instructions

VACUUM REGULATORS CONTENTS

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

Modular F.R.L. Units. New. New. Series AC 46% Better visibility and environmental resistance. Energy saving regulator

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

Standard Specifications

Airpel -FFR Overview PUB# FFRP-04R. Airpot, Airpel, and Anti-Stiction are registered trademarks of Airpot Corporation

Booster Regulator/Air Tank

Filter-Regulator-Lubricator

Precision Regulator. Series Model Regulating pressure range Port size Page

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

NEWS 66. VALVES & AIR SERVICE UNITS STEEL LINE Series

LRS(H)4 Pressure-Reducing Regulator User Manual

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

C 0G 00 N/US

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

1200 Series Pressure Regulators

Precision Pressure Regulators

Pilot Check Valve: Metal Body Type

IR1000-A IR1010-A IR1020-A

Compressed Air Cleaning Filter Series

Hand lever valves VHER

Float Operated Level Controllers

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

Regulator/Modular Style AR1000 to 6000

essentialsguide World leading airline solutions Air preparation When you need it fast. Issue contents 03 FRLs with an added component.

FR12MD FR38MD. Modular filter-regulators, suitable for compressed air FEATURES. Filter-regulator for inlet pressure up to 30 bar (435 psi).

Quick Release Couplings 233 Series

Model AWG20 AWG30 AWG40 AWG20K AWG30K AWG40K

SATURNSERIES INTERCHANGE > ISO (for the couplings)

ISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4

4/2 way Pneumatic Solenoid Valve

ALF400 to 900, ALT-5/-9

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Transcription:

> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant feature > Metal bowl with prismatic liquid level indicator lens > 5 or 40 micron particle and high efficiency water removal (> 98%) > Double safety lock bowl > Light weight Polycarbonate bowl > Easy to read flush mounted integrated pressure gauge as standard Technical features Medium: Compressed air only Maximum supply pressure: Polycarbonate bowl: 10 bar (145 psi) Metal bowl: 20 bar (290 psi) Outlet pressure ranges: 0,3...10 bar (4... 145 psi), 0,3... 4 bar (4... 58 psi) optional, 0,7... 17 bar (2... 250 psi) optional Filter element: 5 μm & 40 μm Port size: G3/8, G1/2, G3/4, 3/8 PTF, 1/2 PTF, 3/4 PTF Gauge: Integrated as standard Gauge port 1/8 as option Flow: 100 dm 3 /s At port size: 1/2, inlet pressure 10 bar (145 psi), 6,3 bar (91 psi) set pressure and a Δp: 1 bar (14,5 psi) droop from set. Filter element: 40 μm Diaphragm Type: Relieving Drain: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0,35 bar (5 psi) Bowl pressure required to open drain: 0,2 bar (2.9 psi) Minimum air flow required to close drain: 1 dm 3 /s (2 scfm) Ambient/Media temperature: Polycarbonate bowl: -10... +60ºC (+14... +140ºF) Metal bowl: -20... +65ºC (-4... +149ºF) Air supply must be dry enough to avoid ice formation at temperatures below +2 C (+35 F). Materials: Body: Die cast aluminium Body covers: ABS Bonnet: Acetal/ Aluminium Valve: PP Bowl: Transparent PC with PP guard or die cast aluminium Liquid level indicator lens (metal bowl): PA Filter element: sintered PP Bowl o - ring: Chloroprene Elastomers: NBR Technical data B84G - standard models Symbol Port size Drain Pressure range Filter element Bowl Weight Model *1) (bar) (µm) (kg) G3/8 Auto 0,3... 10 40 Guarded polycarbonate 0,73 B84G-3GK-AP3-RMG G1/2 Auto 0,3... 10 40 Guarded polycarbonate 0,73 B84G-4GK-AP3-RMG G3/4 Auto 0,3... 10 40 Guarded polycarbonate 0,73 B84G-6GK-AP3-RMG G3/8 Auto 0,3... 10 40 Metal with level indicator 0,88 B84G-3GK-AD3-RMG G1/2 Auto 0,3... 10 40 Metal with level indicator 0,88 B84G-4GK-AD3-RMG G3/4 Auto 0,3... 10 40 Metal with level indicator 0,88 B84G-6GK-AD3-RMG G3/8 Manual 0,3... 10 40 Guarded polycarbonate 0,73 B84G-3GK-QP3-RMG G1/2 Manual 0,3... 10 40 Guarded polycarbonate 0,73 B84G-4GK-QP3-RMG G3/4 Manual 0,3... 10 40 Guarded polycarbonate 0,73 B84G-6GK-QP3-RMG G3/8 Manual 0,3... 10 40 Metal with level indicator 0,88 B84G-3GK-QD3-RMG G1/2 Manual 0,3... 10 40 Metal with level indicator 0,88 B84G-4GK-QD3-RMG G3/4 Manual 0,3... 10 40 Metal with level indicator 0,88 B84G-6GK-QD3-RMG *1) All models shown here are supplied with integrated gauge applicable for flow direction left to right. With flow direction right to left please use the online configurator www.imi-precision.com/air-preparation-configurator or contact IMI Norgren without notice, the specifications given in this document. (2017-9217b) 2015 Norgren Ltd en 8.200.350.01

Option selector *1) Port size 3/8 3 1/2 4 3/4 6 Thread form PTF A ISO G parallel (standard) G Adjustment Knob (standard) K T-bar T*2) Drain Manual (standard) Q Auto drain (standard) A Bowl Metal with liquid indicator D Transparent with guard P (standard) *1) All models shown here are applicable for flow direction left to right. With flow direction right to left please use the online configurator www.imi-precision.com/air-preparation-configurator or contact IMI Norgren *2) Units with 17 bar outlet pressure range are available only with the T-bar adjustment; therefore substitute T at the 7th position and S at the 9th position. T-bar handle only available with 17 bar option. B84G- - -R Gauge With integrated gauge G Without integrated gauge N but with gauge port 1/8 Pressure range *3) 0,3... 4 bar F 0,3... 10 bar (standard) M 0,7... 17 bar S*2) Element 40 µm (standard) 3 5 µm 1 *3) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges. Flow characteristics Inlet pressure: 10 bar (145 psi) Port size: 1/2, 40 µm element Outlet pressure (bar) B84G - 10 bar inlet 9,0 8,0 7,0 6,0 5,0 4,0 3,0 2,0 1,0 0,0 0 10 20 30 40 50 60 70 80 90 100 110 120 Air flow (dm 3 /s) en 8.200.350.02 without notice, the specifications given in this document. (2017-9217b) 2015 Norgren Ltd

Accessories Quikclamp Quikclamp with bracket assembled NECK mounting bracket & Panel nut Panel mounting nut Mounting bracket Page 6 Page 6 Page 6 Page 6 Page 6 840014-51KIT 840014-52KIT 840068-51KIT 840048-89KIT 840024-50KIT Integrated gauge 10 bar gauge Integrated gauge 20 bar gauge Gauge adaptor kit 1/8 PTF Gauge adaptor kit R 1/8 840073-01KIT 840073-02KIT 840100-01KIT 840100-02KIT Pressure sensing block 1/4 PTF Pressure sensing block G1/4 Padlock Lockout device Page 7 Page 7 840016-50KIT 840016-51KIT 840055-01KIT 840055-02KIT Full flow porting block 3/4 PTF Full flow porting block G3/4 Pressure switch interface block (18D pressure switch) Pneumatic pressure switch 18D (0,5... 8 bar) *1) Digital pressure switch 51D (-1... 10 bar) *2) Page 7 Page 7 Page 7 Page 7 Page 8 840028-50KIT 840028-53KIT 0337717000000000 0881300 0860810 *1) Flanged version. For other pressure ranges, please see data sheet 5.11.001 *2) For other pressure ranges, please see data sheet 5.11.385 Gauges (For regulators with gauge port instead of integrated port ) Port Adaptors Center back connection, white face (for full technical specification see datasheet 8.900.900) Page 7 3/8 PTF 840015-02KIT 1/2 PTF 840015-03KIT 3/4 PTF 840015-04KIT G3/8 840015-10KIT G1/2 840015-11KIT G3/4 840015-12KIT Pressure range (bar) *3) (MPa) (psi) ø Thread size Model 0... 6 0... 0,6 0... 84 50 mm R1/8 18-015-012 0... 10 0... 1 0... 145 50 mm R1/8 18-015-013 0... 25 0... 2,5 0... 362 50 mm R1/8 18-015-014 *3) primary scale without notice, the specifications given in this document. (2017-9217b) 2015 Norgren Ltd en 8.200.350.03

Maintenance/Service Auto drain kit with metal Nut - Imperial Auto drain kit with metal Nut - Metric R84 / B84 Elastomer Kit Filter cartridges 5 micron Filter cartridges 40 micron 6000-61KIT 6000-60KIT FRLB84-KIT 840038-50KIT 840038-51KIT Spare parts (Guarded Poly bowl with auto drain 6 mm PIF) (Guarded Poly bowl with manual drain) (Metal with S/Glass & auto drain, 6 mm PIF) (Metal with S/Glass & manual drain) 840025-51KIT 840025-50KIT 840003-51KIT 840003-50KIT (Guarded Poly bowl with auto drain, 1/4 PIF) (Metal with S/Glass & auto drain, 1/4 PIF) 840025-53KIT 840003-56KIT en 8.200.350.04 without notice, the specifications given in this document. (2017-9217b) 2015 Norgren Ltd

39 16 43 115 124 143 38 74 # 25 # 25 181 43 39 16 115 124 B84G - Excelon Plus Modular System Dimensions Dimensions in mm Projection/Third angle 58 70 1 1 43 2 205 178 178 1/4 Turn Manual Drain Automatic Drain 1/4 Turn Manual Drain With knob With T-bar # Minimum clearance for bowl removal 1 Main ports 3/8, 1/2 or 3/4 (ISO G/PTF) 2 Gauge port Rc 1/8 for ISO G and 1/8 PTF for PTF main ports without notice, the specifications given in this document. (2017-9217b) 2015 Norgren Ltd en 8.200.350.05

29 36 47 57 5 8 23 7.2 35 2 50 85 35.2 49 119 54.3 56 47 54 B84G - Excelon Plus Modular System Accessories Dimensions in mm Projection/Third angle Quikclamp with wall bracket Quikclamp 76 51 14 7 60 11.5 4 5 Neck mounting bracket Panel mounting nut 60 8 36 15 Mounting bracket 8.9 15 58 71 15 4 18 66 31 en 8.200.350.06 without notice, the specifications given in this document. (2017-9217b) 2015 Norgren Ltd

40 40 38.5 30 5 45 18 A/C 46 57 51 B84G - Excelon Plus Modular System Pressure sensing block Full flow porting block Dimensions in mm Projection/Third angle 80 51 68 45 21 33 Porting block for 18D pressure switch 18D Pressure switch 27.5 32 44 G1/2 40 30 35 72 18D Porting block and 18D assembled Pipe adaptor 38.5 18 32 44 G1/2 40 57 without notice, the specifications given in this document. (2017-9217b) 2015 Norgren Ltd en 8.200.350.07

51D Pressure switch - digital 31 36,5 Dimensions in mm Projection/Third angle 1 2 ~30 ~300 31 6 5 G1/8 7 1 Switch OUT 1, green LED 2 Switch OUT 2, red LED 3 Dustproof protector 4 Connector M12 x 1 5 Inlet port 6 Alternative inlet port G1/8 plugged 7 Thread for mounting screw 3 4 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, Norgren Ltd. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. en 8.200.350.08 without notice, the specifications given in this document. (2017-9217b) 2015 Norgren Ltd