Installation Guide. buoy.ai

Similar documents
How Do I Install My Garden Master Bucket Garden?

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

Installation Instructions

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

Engineering Excellence. Installation Guide

Installation Instructions

INSTALLATION INSTRUCTIONS

Bladder Tank Installation & System Design Information

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

MIDDLESEX COUNTY COLLEGE EDISON, NJ LOCAL SUPPLIER BLANKET ORDER SPECIFICATIONS

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

OWNER S TECHNICAL MANUAL

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual STOP!

LARGE DRY CHEMICAL, TWIN-AGENT, AFFF, HALON 1211, AND AQUASONIC (NITROGEN-OPERATED SYSTEMS) Pressure Regulator Test Manual

UltRo Dual Flow Reverse Osmosis Water System

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

DESIGN AND PRE - INSTALLATION INFORMATION

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

1 Exam Prep. Tabs and Highlights

TECHNICAL DATA. Trimpac 244a. September 16, 2013

LP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957

INSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS

Summary of Accumulators These operating instructions apply to the accumulators listed in the table shown below.

Sanitizer Parts. Sanitizer Parts. Replacement Parts for Sanitizers

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Model PSI Compressor with 3-Gallon Air Tank 12VDC

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Your safety and the safety of others are very important.

TECHNICAL DATA. Page 1 of 12

6890 GC Site Preparation

CO2 Tank Conversion Kit P.N , P.N , and P.N

SINORIX Valve Reconditioning

Aquor House Hydrant V2

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Installing ASI Umbilical Delivery Systems

VERTICAL BLADDER TANK

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

HORIZONTAL BLADDER TANK

Wet pipe low flow foam/water system

D05 Pressure Regulating Valves

ATD /8 x 50 Retractable Air Hose Reel Owner s Manual

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

Chlorinator. MODEL C-731 (Floor Mounted)

Booster Pump PB4-60 Replacement Kits

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

INSERT FITTINGS INSERT FITTINGS

Retractable Hose Reel with 3/8" x 50' PVC Hose

Horizontal Bladder Tanks

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

TECHNICAL DATA CAUTION

For every inch of rain that falls on a catchment area of 1,000 square feet, you can expect to collect about 600 gallons of water.

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Basic layout 2016 IRRIGATION-MART. Check (Non- Leak) Valve. Friction Fit. Sprinkler. Figure 1 - Hanging Sprinkler & Check Valve Assembly

URINAL FLUSHING SYSTEM WITH MICROWAVE SENSOR

Vertical Bladder Tanks

INSTALLATION INSTRUCTIONS

Natural Gas Conversion Kit

OPERATING INSTRUCTIONS

VOLUMATIC WATER REGULATOR

Setup Guide for your HVO Naked Drone

FOAM TANK (1/2) DATA SHEET

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Axial Compression Packing Method

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

LEAK TROUBLESHOOTING

Build Your Own Flamethrower Step-by-step Manual

EXOTHERMIC TORCH ADAPTER. Instruction Manual

Speed control assembly model A-1

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

INSTALLATION INSTRUCTIONS 1/2 THERMOSTATIC VALVE AND TRIM

Model MTB-ASME Vertical Bladder Tanks

Wirsbo / AquaPEX. AquaPEX Tube. White Coils. White Straight Lengths. Wirsbo AquaPEX plus Tubing. Red Coils. Blue Coils PAGE 055-1

Vessel Installation and Operating Manual

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Installation Instructions

PLUMBING WATER & GAS TRADE CATALOGUE

VOLUMATIC WATER REGULATOR

KJ4000 Operating Instructions & Parts Manual NSN

Model MTB-ASME Horizontal Bladder Tanks

Beverage Systems. Component Inspection and Service TSB-Y Date: Subject: Products Affected: Description: July Inspection of CO 2

Model MTB-ASME Vertical Bladder Tanks

BGC258 Series BASOTROL Gas Valve

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

TECHNICAL DATA. than the water inlet pressure to the concentrate

Medical Gas Control Panel

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Flow Material Length. Weight GPM LPM. Style 3095

2.0 INSTALLATION & SERVICE

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)

Continental Industries STEEL SERVICE TEES or FAX Visit

MyControl Bathing System Signature Series

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

accidents which arise due to non-observance of these instructions and the safety information herein.

Transcription:

Installation Guide buoy.ai

Notes

In the Box Buoy unit Battery and Charger assembly 3/4 meter couplings (2) Rubber gaskets (6) Also included: Buoy Quick Start Guide Buoy Installation Guide Buoy sticker Buoy tape measure PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Contact a licensed plumber for professional installation of your Buoy 1

Prepare for Installation Please note: Buoy may only be installed in homes with an existing main water shutoff, and should NOT be installed on fire sprinkler water lines or fire suppression systems. Checklist prior to installation Before starting, take a photo of the main water line where the Buoy will be installed. This is a good reference for the installation process. Locate the water main into the house. Locate the house shutoff valve. The Buoy must be installed after the water main s manual shutoff and the utility water meter, if any. Additional fittings may be required. House valve Main line into house Main shutoff (utility) OR supply tank shutoff (well) 2 Remove the battery and charge until full, using the battery charging kit. If installing indoors, and plugging the Buoy in permanently, locate a nearby 110v power outlet. If there is no convenient outlet, or installing outdoors, the battery pack will power Buoy for up to 8 months between charges.

Outlet Outlet Outlet Inlet Inlet Inlet (Optional) waterhorn installation Checklist prior to installation (continued) Identify a space for the Buoy. The device can be installed horizontally or vertically. Make sure the Buoy logo with LED light faces out. For vertical installations, be sure the outlet is above the inlet. Identify the diameter (adapters are required for anything other than ¾ ) and type of pipe (PVC, copper, galvanized). Turn off water at the home s main supply valve. Verify it is off by trying both hot and cold water in the house. Turn off the water heater input to prevent drain-out. Drain water from the entire house via any nearby hose bib. Protect the Buoy from scratches during setup by laying it on a soft surface or cardboard. Measure and mark the pipe for cutting. With pipe cutter or hacksaw, cut the pipe at your mark. Clean the ends of the cut pipe with steel wool or a similar sanding agent. 3

Option 1: Install In-Line In-line installation requires a minimum pipe gap length of 13 for the Buoy and 5 for the optional 3/4 union joints. Allow extra space for any additional adapters needed (not included). Outlet Outlet 13 (33cm) Inlet Inlet 1. Install the optional couplings (included) using the thickest possible rubber washers (included). Use a smooth-jawed wrench for tightening. Do not use force or overtighten. Use teflon tape only if needed. Liquid thread sealer is not recommended. 2. Use the two rounded rubber gaskets (included) between the Buoy or coupling and the copper adapter compression nuts (not included). 3. Put the Buoy in place and tighten the compression nuts between the Buoy and the water lines. Make sure the Buoy logo is facing outward and the LED is visible. 4. Make sure the Buoy is securely braced. 4

Option 2: Install with Optional Waterhorn Accessory Minimizes cut space with purchase of waterhorn accessory. Requires pipe gap length of approximately 4. 4 (approx 10cm) 1. Install copper FPT female adaptor (not included) on each pipe. 2. Place one white gasket inside each of the union fittings at the top and bottom of the waterhorn. 3. Assemble waterhorn union fittings, copper FPT female adaptors and the waterhorn. Tighten all fittings. Teflon/plumber s tape may be needed. 4. Place the Buoy in the waterhorn with a black gasket on each side, and tighten the swivel adaptors (do not overtighten). Make sure the Buoy logo is facing outward and the LED is visible. 5. Make sure the Buoy is securely braced. 5

Option 3: Install with Flexible Line (not included) 1. Attach the ¾ couplings with rubber gaskets (included) to each end of the Buoy. 2. Attach flexible lines to each coupling. 3. Use professional judgement to secure the Buoy to the wall with strapping, such as Unistrut or similar. The Buoy should be securely braced. 4. Make sure the Buoy logo is facing outward and the LED is visible. 6

Post-Installation Be sure the blue end of Buoy faces the water INLET and the gray end of Buoy faces the water OUTLET. Outlet Inlet BLUE end = Inlet GRAY end = Outlet Verify the Buoy s fit and check that the device is level and secure. Use the LED indicator to verify that the Buoy s power is on. The LED will glow white when power is connected, then begin to flash. It will stop flashing after about one minute. Turn on the water at the main. Verify that there are no leaks and that the house pressure is between 50 psi and 80 psi. Turn on the water heater input. Test: Ask the homeowner to run water through the system to verify normal water flow. Consult the Quick Start Guide to connect the Buoy to WiFi. Setup is now complete! Questions? Contact Customer Service at support.buoy.ai. 7

Notes 8

buoy-installation-guide-091217 9

2017 Buoy Labs, Inc.