The Facts & Myths About Shorted Casings

Similar documents
New Hampshire Public Utilities Commission CFR 49 Part 192 Regulations. MINIMUM Pipeline Safety Regulations

EASIDEW TRANSMITTER with Current Source Output

DK46 - DK800 Supplementary instructions

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Baseline Two-Wire Technology

Designing an ICCP System for the Hull of an Arctic Ice-Breaking Vessel

Cathodic Protection and Underwater Survey for an Floating Storage Offloading (FSO) System

Instrumentation & Data Acquisition Systems

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

Corrosion problems in seawater pump caissons. Practical solutions.

High-performance submersible pressure transmitter For level measurement Model LH-10

Owners Manual Release Date: Thursday, December 29, 2011

CONSIDERATIONS FOR THE USE OF SEA WATER IN FIREFIGHTING. Prepared and Presented by Lenny Naidoo (Chief Fire Officer), Engen Petroleum Company

Application Information: carbon steel (TiN, black oxide) cast iron (TiN, black oxide) non-ferrous materials (bright)

Primary Terminals & Connectors

DRAFT. NEW Products SWIVEL LOOP HANGER 100 LOOP HANGER SURGE RESTRAINT LHSR6. See page 20. See page 20

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

NATURAL GAS MAINTENANCE. Part 192 Subpart "M"

Re-usable Riser and Flowline System for Deep Water Application. C. DIEUMEGARD SUBSEA ASIA - 11 th June 2008

OPTIBAR P 1010 C Technical Datasheet

INSTALLATION OPERATION MAINTENANCE

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

GA24 Technical Datasheet

Covered Task 409OP Training Guide Inspecting Interference Bonds

Casing Spacer Technology Leaders

The Application Of Computer Modeling To Improve The Integrity Of Ballast Tanks

User Information Sheet 015

SDX Submersible Depth Transmitter User Manual

Instructions for Installing and Operating Clark Reliance EA101 Series Levalarm

7 Common Cattle Fencing Mistakes. Seven of the most common errors in livestock fencing, and how to avoid them.

NO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice

High-performance submersible pressure transmitter For level measurement Model LH-10

Structural Assessment. USS Yorktown CV-10

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

Copper Bonded Ground Rod / Grounding Rods / Copper Bonded Earth Rod / Earthing rods

Polatrak ROV II - Tip Contact Probe Operation Manual

We re good at what we do! Anywhere, TX SITE

Notable Clarifications to Directive 077 Requirements

Sizing Enclosures for SCR Power Controllers

TECHNICAL DATA. Q = C v P S

Investigation of failures

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA. Q= Cv S

CSO/STORMWATER MANAGEMENT. HYDROVEX VHV / SVHV Vertical Vortex Flow Regulator

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TABLE OF CONTENTS PART 2 - CONFINED SPACES

Differential Pressure Transmiter

Geopress. Instructions for Use. Year built: from 01/2004 en_int

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

tubepress press procedure

PSI Compakt - Special Seals

FIRE PROTECTION. In fact, hydraulic modeling allows for infinite what if scenarios including:

CHAIN LINK FENCE GATE

Part 3: Safety Rules for the Installation and Maintenance of Underground Electric Supply and Communication Lines

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

Accident Investigations: Finding the Root Cause is NOT Enough

Expert Hydrostatic Level Transmitters

Pressure Reducing Valve DMV 755

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

WP2 Fire test for toxicity of fire effluents

PANACEA P100 LOW PRESSURE USER MANUAL

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

Sept 23, 2014 LAB MANUAL

OPERATING MANUAL. Contents. Bottom outlet ball valve Type ecoline

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS

Printview: End and intermediate plate; 1 mm thick - Item No.:

Committee Input No. 59-NFPA [ Section No. 5.9 ]

GENERAL NOTES FOR SWIMMING POOLS AND SPAS

Features. RP011 - Compact Multimedia X-Slim Keyboard. Brief Specification Product Dimension: Keyboard:320(L) 160(W) 14.5(H)mm

Bermad Pressure Reducing. Model: 42T

9700 Transmitter Submersible hydrostatic level transmitter

Basic layout 2016 IRRIGATION-MART. Check (Non- Leak) Valve. Friction Fit. Sprinkler. Figure 1 - Hanging Sprinkler & Check Valve Assembly

FLANGED TWO-PIECE BALL VALVES

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

Amador Circle Tank. City of Rio Vista. Report of Findings From the Diving Operations Conducted on. March 28, 2011

RESIDENTIAL IRRIGATION WORKSHOP IRRIGATION 101 AND BEYOND FOR WEST BENCH RESIDENTS

Pipe-Away Pressure Vacuum Vent /Conservation Vent

CS10 # Network Safety Performance Objectives (2016)

SDX Submersible Depth Transmitter User Manual

Installation, Operation and Maintenance Instructions for Direct Hot Water Storage Vessels

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Wirsbo / AquaPEX. AquaPEX Tube. White Coils. White Straight Lengths. Wirsbo AquaPEX plus Tubing. Red Coils. Blue Coils PAGE 055-1

Osborne Engineering Limited. OEJ Equalised thrust bearing internals

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

FLANGED TWO-PIECE BALL VALVES

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

OXYGEN MONITORING SYSTEM OMS

Product Catalogue. February We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping

Wild Card Horse Ranch

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Residential and Small Commercial

New MacLean-Dixie 4-1/2 Strength Squared Pipe Piles/Anchors (Patent Pending) for Compression and Tension Applications

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Recommendations for Marking Communication Facilities

WALLAS LEAD-THROUGHS 1066, 2460, 2466, 2467, 3467, 3468

FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS

Transcription:

The Facts & Myths About Shorted Casings Presented to TEG 292X [35,05] Direct Assessment Methodology Application 10 September 2006 by Earl L. Kirkpatrick, P.E. ELK Engineering Associates, Inc.

There Ain t No Such Thing As a Water Short!!! A direct metallic contact: Pipeline Steel to Casing Steel Or Test Lead Wire to Casing Steel IS A SHORT If there s water in a casing annulus, it may cause a potential shift on the casing, but IT IS NOT A SHORT

Office of Pipeline Safety Code of Federal Regulations 192.467 External corrosion control: Electrical isolation. (c) Except for unprotected copper inserted in ferrous pipe, each pipeline must be electrically isolated from metallic casings that are a part of the underground system. However, if isolation is not achieved because it is impractical, other measures must be taken to minimize corrosion of the pipeline inside the casing.

ASSUMPTIONS Casing end seals keep rocks, dirt, and creepy-crawly critters out of casings, not water Moderately corrosive low resistivity soils Free Corrosion Potentials: -550 Bare Casing Pipe -450 Well Coated Pipeline* * Typically well coated pipelines exhibit lower P/S potentials than bare pipelines in the same soil conditions 2 ma/ft 2 required to polarize to -850 on (from -450) or 200 mv/ma polarization Linear polarization characteristics over a reasonable P/S potential range Ignore IR drops in water in the annular space

Therefore we may assume the following polarized P/S potentials, based upon assumed current densities per square foot of bare surface area. C.P. Current Density (ma/ft 2 ) Coated pipeline or casing (V) Base casing (V) Free Corrosion Potential -0.450-0.550 1 2 3 4 5 6 7 8-0.650-1.050-1.450-1.850-2.050-0.750-0.950-1.150-1.350-1.550-1.750-1.950-2.150

POST MOUNTED TEST STATION PIPELINE MARKER 4'-0" 3'-0" 2-#12 STR CU THW WHITE TEST LEADS CASING PIPE CASING INSULATOR (TYPICAL) CASING END SEAL (TYPICAL) CARRIER PIPE LOW END OF CASING NOTES : 1. TEST STATION REQUIRED AT ONE END OF CASING ONLY. INSTALL AT MOST CONVENIENT OR PROTECTED SITE. SKETCH b232901

Dry or water below the carrier pipe No pipeline CP current demand inside of the casing

Annulus partially full of water Holidays on bottom of pipe Minimal CP current demand

Annulus flooded All holidays in contact with the electrolyte Maximum CP current demand

SCENARIO I PIPE 2% Bare Bare Casing Pipe Condition Surface Area (ft 2 ) Resulting Polarized P/S Potentials 2 ma/ft 2 4 ma/ft 2 6 ma/ft 2 Holidays Holidays Holidays 100 ft 12 Pipe 333.8 3.338 6.676 ma 20.028 ma Pipe Submerged 6.672 100 ft 16 Casing 418.9 Casing potential 418.9-0.5516-0.5532-0.5548 Casing Potential Pipe 418.9

SCENARIO I PIPE 2% Bare Bare Casing Pipe Condition Surface Area (ft 2 ) Resulting Polarized P/S Potentials 2 ma/ft 2 4 ma/ft 2 6 ma/ft 2 Holidays Holidays Holidays 100 ft 12 Pipe 333.8 3.338 6.676 ma 20.028 ma Pipe Submerged 6.672 26.704 ma 40.056 ma 100 ft 16 Casing 418.9 Casing potential 418.9-0.5516-0.5532-0.5548 Casing Potential Pipe 418.9-0.5532-0.5564-0.5596

SCENARIO II PIPE 2% Bare Coated Casing 50% Bare Pipe Condition Surface Area (ft 2 ) Resulting Polarized P/S Potentials 2 ma/ft 2 4 ma/ft 2 6 ma/ft 2 Holidays Holidays Holidays 100 ft 12 Pipe 333.8 3.338 6.676 ma 20.028 ma Pipe Submerged 6.672 100 ft 16 Casing 418.9 Casing potential 209.45-0.5532-0.5564-0.5596 Casing Potential Pipe 209.45

SCENARIO II PIPE 2% Bare Coated Casing 50% Bare Pipe Condition Surface Area (ft 2 ) Resulting Polarized P/S Potentials 2 ma/ft 2 4 ma/ft 2 6 ma/ft 2 Holidays Holidays Holidays 100 ft 12 Pipe 333.8 3.338 6.676 ma 20.028 ma Pipe Submerged 6.672 26.704 ma 40.056 ma 100 ft 16 Casing 418.9 Casing potential 209.45-0.5532-0.5564-0.5596 Casing Potential Pipe 209.45-0.5564-0.5628-0.5691

SCENARIO SCENARIO III PIPE III 2% Bare Coated Casing 2% Bare Pipe Surface Area Condition (ft 2 ) 100 ft 12 Pipe 333.8 Resulting Polarized P/S Potentials 2 ma/ft 2 4 ma/ft 2 6 ma/ft 2 Holidays Holidays Holidays 3.338 6.676 ma 20.028 ma Pipe Submerged 6.672 100 ft 16 Casing 418.9 Casing potential Casing Potential Pipe 8.378 8.378-0.5297-0.6094-0.6891

SCENARIO SCENARIO III PIPE III 2% Bare Coated Casing 2% Bare Pipe Surface Area Condition (ft 2 ) 100 ft 12 Pipe 333.8 Resulting Polarized P/S Potentials 2 ma/ft 2 4 ma/ft 2 6 ma/ft 2 Holidays Holidays Holidays 3.338 6.676 ma 20.028 ma Pipe Submerged 6.672 26.704 ma 40.056 ma 100 ft 16 Casing 418.9 Casing potential Casing Potential 8.378-0.5297-0.6094-0.6891 Pipe 8.378-0.6094-0.7687-0.928

SCENARIO SCENARIO IV PIPE IV 2% Bare Coated Casing 1% Bare Pipe Surface Area Condition (ft 2 ) 100 ft 12 Pipe 333.8 Resulting Polarized P/S Potentials 2 ma/ft 2 4 ma/ft 2 6 ma/ft 2 Holidays Holidays Holidays 3.338 6.676 ma 20.028 ma Pipe Submerged 6.672 100 ft 16 Casing 418.9 Casing potential Casing Potential Pipe 4.189 4.189-0.6094-0.7687-0.9281

SCENARIO SCENARIO IV PIPE IV 2% Bare Coated Casing 1% Bare Pipe Surface Area Condition (ft 2 ) 100 ft 12 Pipe 333.8 Resulting Polarized P/S Potentials 2 ma/ft 2 4 ma/ft 2 6 ma/ft 2 Holidays Holidays Holidays 3.338 6.676 ma 20.028 ma Pipe Submerged 6.672 26.704 ma 40.056 ma 100 ft 16 Casing 418.9 Casing potential Casing Potential 4.189-0.6094-0.7687-0.9281 Pipe 4.189-0.7687-1.087-1.406

SCENARIO SCENARIO V Coated Pipe V 5% Bare Coated Casing 2% Bare Pipe Surface Area Condition (ft 2 ) 100 ft 12 Pipe 333.8 Resulting Polarized P/S Potentials 2 ma/ft 2 4 ma/ft 2 6 ma/ft 2 Holidays Holidays Holidays 5% Holidays 9.345 16.69 ma 33.38 ma 50.07 ma 5% Holidays Pipe Submerged 16.69 100 ft 16 Casing 418.9 Casing potential Casing Potential Pipe 4.189 4.189-0.8484-1.247-1.645

SCENARIO SCENARIO V Coated Pipe V 5% Bare Coated Casing 2% Bare Pipe Surface Area Condition (ft 2 ) 100 ft 12 Pipe 333.8 Resulting Polarized P/S Potentials 2 ma/ft 2 4 ma/ft 2 6 ma/ft 2 Holidays Holidays Holidays 5% Holidays 9.345 16.69 ma 33.38 ma 50.07 ma 5% Holidays Pipe Submerged 16.69 33.38 ma 66.76 ma 100.14 ma 100 ft 16 Casing 418.9 Casing potential Casing Potential 4.189-0.8484-1.247-1.645 Pipe 4.189-1.249-2.048-2.847

If it ain t shorted don t call it a short