Supplemental Type Certificate Number: ISA01232SEI Precise Flight Inc. Semi Portable Oxygen System

Similar documents
SUPPLEMENT ORIGINAL ISSUE

DESCRIPTION AND OPERATION OXYGEN SYSTEM OXYGEN SYSTEM

Instructions for Continued Airworthiness Mooney M20M, M20S, M20R, and M20TN Fixed Oxygen System STC Number SA01830SE

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Rev. B. Operating Instructions

EMERGENCY EQUIPMENT Table of Contents CHAPTER 8 - EMERGENCY EQUIPMENT

NO SMOKING WHEN OXYGEN IS IN USE.

Home Oxygen Therapy Patient Handbook

DRAFT U S E R M A N U A L CAUTION. Model: 19MFA1001 Series. Federal (USA) law restricts this device to sale by or on the order of a physician.

European Technical Standard Order (ETSO)

Dash8 - Q400 - Oxygen

SR22 Airplane Flight Manual (AFM) Temporary Change

Welcome to the Specialized Medical Services Respiratory training webinar series!

AUTOVENT 4000 VENTILATOR

Breathing Devices. Chapter 8 KNOWLEDGE OBJECTIVES SKILL OBJECTIVES. 6. List four precautions to take when using oxygen.

ALERT SERVICE LETTER

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS AND EQUIPMENT MAINTENANCE MANUAL FOR OXYGEN BOTTLE MOUNT

CHAPTER 17 MISCELLANEOUS SYSTEMS

Ice Protection System

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

Glider Oxygen Systems

Product Information News

MMR Air Mask With. with Quick-Connect Hose


RD(H)20/25 Pressure-Reducing Regulator User Manual

CHAPTER EMERGENCY EQUIPMENT

why did my provider prescribe supplemental oxygen?

NIOSH Task Number 18388

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

NO SMOKING WHEN OXYGEN IS IN USE.

AIRPLANE AIRWORTHINESS; TRANSPORT CATEGORIES SUPPLEMENTAL OXYGEN REQUIREMENTS

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS AND EQUIPMENT MAINTENANCE MANUAL FOR OXYGEN BOTTLE MOUNT

STAYING ACTIVE WHILE USING OXYGEN. Karla Schlichtmann, RRT

U S E R M A N U A L. (CGA 870 Connection)

4 mm Red inlet connects to the regulator

S-TEC. Pilot s Operating Handbook

DAHER-SOCATA Customer Support. TBM700 - TBM850 - TBM900 Review of high altitude operations

RC 195 Receiver-Controller

Revision Number Revision Date Insertion Date/Initials 1 st Ed. Oct 26, 00 2nd Ed. Jan 15, 08

SUPPLEMENT SEPTEMBER 2010 HIGH ALTITUDE TAKEOFF AND LANDING (ABOVE 14,000 FEET PRESSURE ALTITUDE) MODEL AND ON 68FM-S28-00 S28-1

Complex Care Hub Manual: Oxygen Therapy

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

U.S. Patent No. 7,922,246. Patents Pending

PRODUCT INFORMATION AND INSTRUCTIONS OM-810

BioPak 240 Revolution

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

300 Held Drive Northampton Pa

TECHNICAL DATA. Q = C v P S

TITLE: Pulse Oximetry COMPETENCY #: Resp #1 NEW COMPETENCY REVISION DATE: 10/18/12 EMPLOYEE NAME. DATE INITIAL RE-EVALUATION ANNUAL (if required) PRN

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

Baron Oxygen STC Installation Instructions (Front Baggage Installation) GAMI/Tornado Alley Turbo 2009

Flow meter. bellow vaporizer. APL valve. Scavenging system

1811G/H PITOT-STATIC TEST SET

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

Table of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.

Oxygen Concentrator Instruction

Liquid Oxygen- Helios & Helios Marathon A Guide for Patients in the Home

DASSAULT AVIATION Proprietary Data

AIR CONDITIONING AND PRESSURIZATION CONTROLS AND INDICATORS

TECHNICAL DATA. Q = C v P S

Rejuvenation Instructions

TECHNICAL DATA. Q = C v P S

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

Helium-Oxygen Blender

( SC) NOTE: KMDSI strongly recommends that all repairs be performed by trained Personnel.

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

TECHNICAL DATA. Q = C v P S

SECRETARY OF THE AIR FORCE 1 JUNE 2000 LOADMASTER PROCEDURES

WIKA INSTRUMENT CORPORATION

installation instructions

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

ACCESSORY KIT INSTALLATION MANUAL

DFB FLOW METERS (DESIGNED FOR BLENDERS, DUAL TAPER)

Pressure Regulators. Operating Instructions. Instrumentation

Procedure 85 Attaching The Humidifier To The Oxygen Flow Meter Or Regulator. Procedure 86 Administering Oxygen Through A Nasal Cannula

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

ROTORCRAFT FLIGHT MANUAL SUPPLEMENT. TO THE BELL MODEL UH-1H ROTORCRAFT FLIGHT MANUAL for the APICAL EMERGENCY FLOAT KIT

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

OPERATION MANUAL NTF-15

CIRRUS AMM TEMPORARY REVISION

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PDY TON HYDRAULIC CRIMPING TOOL WARNING

Checklist for care of Respirators

ACRYLIC FLOW METERS 0-30, 0-70 & LPM

TECHNICAL DATA. Q = C v P S

Hallowell EMC Anesthesia WorkStation Operating Manual

DRAFT 12/17/03 KMB 18/28 (BANDMASK) OVERHAUL, MAINTENANCE, AND INSPECTION CHECKLIST APPENDIX A

RE: PROPANE SYSTEM & REGULATOR TESTING/INSPECTION PROCEDURE

Section - III SYSTEMS DESCRIPTION

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

HELiOSTM Plus & Marathon

Oxygen Dialflow Meter. Instructions for Use

Dialflow Regulator. Instructions for Use

Powers Controls RC 195 Multiple Input Receiver- Controller

Operation Manual Piston Sensed Gas Pressure Regulators

Transcription:

Cirrus Design Models: SR20, SR22 Approved Oxygen Systems Precise Flight, Inc. Section 9 Supplements Pilot's Operating Handbook and Airplane Flight Manual Supplement For Supplemental Type Certificate Number: ISA01232SEI Precise Flight Inc. Semi Portable Oxygen System Aircraft Serial Number: Registration Number: -------- When supplemental oxygen is required by the applicable operating rules (FAR Part 91 or FAR Part 135), this Supplement is applicable and must be inserted in the Supplements Section (Section 9) of the Cirrus Design Corporation Models SR20, and SR22, Pilot's Operating Handbook (Handbook). Information in this supplement adds to, supersedes, or deletes information in the basic Handbook. NOTICE The Airworthiness Limitations section (Section 9.0) of this Supplement is and Specifies maintenance required under Sections 23.1529, 23 Appendix G, 43.16, and 91.403 of the Federal Aviation Regulations unless an alternative program has been. FAAAPPROVED<~ DATE ~ Seattle Aircraft Certification Office Federal Aviation Administration PIN 11934-S09 PFI Document: Revision: 003NMAN0001 C Initial Issue of Supplement: 6/27/2003 Page 1 of 47

Semi Portable Oxygen System Revision History Rev. B C Description of Changes Updated revision history table; Added List of Active Pages; Updated AFMS Footers; Updated Section 1.3 to allow Nonin GO 2 Achieve Pulse Oximeter as alternative option Updated revision history table; Updated AFMS Footers; Updated Section 1.3 to recommend Oxi-Go Quick check Pro as an alternative option J. Ruhl PFI Approved By PFI Approved Date W. Ashforth 09/30/09 January 20, 2011 FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 2 of 47 Revision: C

List of Active Pages PAGE REV PAGE REV 1 C 41 C 2 C 42 C 3 C 43 C 4 C 44 C 5 C 45 C 6 C 46 C 7 C 47 C 8 C 9 C 10 C 11 C 12 C 13 C 14 C 15 C 16 C 17 C 18 C 19 C 20 C 21 C 22 C 23 C 24 C 25 C 26 C 27 C 28 C 29 C 30 C 31 C 32 C 33 C 34 C 35 C 36 C 37 C 38 C 39 C 40 C P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 3 of 47

Service Bulletin Configuration List The following is a list of service bulletins applicable to the operation of the airplane, and have been incorporated into this Supplement. This list contains only those service bulletins that are currently active. Number Title Airplane Serial Effectivity Revision Incorporated Incorporated in Airplane FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 4 of 47 Revision: C

Table of Contents Revision History... 2 List of Active Pages... 3 Table of Contents... 5 Section 1 General System Overview... 6 1.1 Constant Flowmeters... 8 1.2 PreciseFlow Oxygen Conservers (PFOC)... 10 1.2.1 Dual Lumen Cannula Use... 14 1.2.2 Dual Supply Demand Mask Use... 16 1.3 Optional Pulse Oximeters... 18 1.3.1 Optional Nonin Medical FlightStat Pulse Oximeter... 18 1.3.1.1 How to Use and Read the FlightStat... 19 1.3.2 Optional Nonin Medical GO2 Achieve Pulse Oximeter... 20 1.3.2.1 How to Use and Read the Nonin GO2 Achieve... 22 1.3.3 Optional Oxi-Go Non-Medical Oxi-Go Quickcheck Pro Pulse Oximeter.. 23 1.3.3.1 How to Use and Read the QuickCheck Pro... 25 1.4 Mask and Cannula Use... 26 Section 2 Limitations... 26 Section 3 Emergency Procedures... 28 3.2 Smoke and Fume Elimination... 28 Section 4 Normal Procedures... 29 4.2 Preflight... 29 4.3 Before Starting Engine (If Oxygen is required or preferred)... 30 4.4 Enroute (If Oxygen is required or preferred)... 30 4.5 Shutdown... 31 Section 5 Performance... 32 5.2 A4 Constant Flow Meter with Oxymizer Oxygen Conserving Cannula... 33 5.3 A4 Constant Flow Meter with Standard Cannula or Constant Flow Mask... 34 5.4 A5 Constant Flow Meter with Oxymizer Oxygen Conserving Cannula... 35 5.5 A5 Constant Flow Meter with Standard Cannula or Constant Flow Mask... 36 5.6 PreciseFlow Oxygen Conserver (PFOC) Normal Operation... 37 Section 6 Weight & Balance... 38 Section 7 System Description... 38 Section 8 Handling, Service, & Maintenance... 39 8.1 Support/Strap Mounting Instructions... 39 8.2 Bottle Mounting Instructions... 40 8.3 Refilling the Oxygen Bottle... 40 8.4 Oxygen Component Cleaning... 42 Section 9 Instructions for Continued Airworthiness... 43 9.1 Introduction... 43 9.2 Changes to Instruction for Continued Airworthiness... 43 9.3 System Description... 43 9.4 Specialty Tools Required... 43 9.5 Maintenance Instructions... 43 9.6 Troubleshooting Guide... 44 9.7 Airworthiness Limitations... 44 9.8 Scheduled Maintenance Intervals and Inspections for Continued Airworthiness... 45 9.9 Contact Information... 46 P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 5 of 47

Section 1 General System Overview This supplement provides information that should be observed when using the Precise Flight is installed to provide supplemental oxygen for the Pilot and passengers. The system consists of a 22 cu. ft. bottle and pressure regulator located between the aft passenger seats. A manual shutoff controls oxygen supply to the regulator and a pressure gauge indicates oxygen quantity. Four flow devices may be connected to the oxygen regulator consisting of manually operated oxygen supply constant flowmeters, or demand flow conservers. The A4 and A5 constant flowmeters are calibrated and adjustable for altitude to supply oxygen to either oxygen conserving cannulas or masks for altitudes up to the maximum operating altitude of the Cirrus SR20 or SR22 or 25,000ft whichever is less. The PreciseFlow demand flow conservers are calibrated and adjusted by the user for altitude to supply oxygen to either dual lumen cannulas, or dual sensing masks for use to altitudes up to the maximum operating altitude for the Cirrus SR20, or SR22 or 25,000ft whichever is less. Note Facemasks covering the nose and mouth are required above 18,000ft per 14 CFR Part 23.1447. The system requires the pilot and passengers to don either a cannula or an oxygen mask first, and then the pilot will open the oxygen valve and noting oxygen quantity and subsequently set the flow devices to the pressure altitude chosen for flight or at a setting above the altitude chosen to meet the pilot and passenger physiological requirements. The flow devices provide the means to distribute the appropriate amount of oxygen for the pressure altitude of flight and indicate the presence of flowing oxygen to the pilot or passengers. The Flowmeter or flow indicator should be checked periodically (Less than 10 min.) as well as the oxygen quantity gauge. Each flow devise should be reset with each change in pressure altitude. Prior to flight, the pilot must ensure sufficient oxygen quantity (pressure) exists for the flight and for passenger requirements using the duration charts included in this Supplement. The System is turned ON at the oxygen bottle/regulator at pilot discretion to meet personal physiological or FAA flight rule requirements. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 6 of 47 Revision: C

All delivery systems must be properly set to the corresponding altitude with each change in pressure altitude. This supplement lists the only FAA approved semi-portable oxygen system components that may be used in the SR20 or SR22 when supplemental oxygen is required by the applicable operating rules, as well as providing mounting instructions. Figure 1 - Installed Semi-Portable System with Aft Left Seat Hidden for Clarification P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 7 of 47

1.1 Constant Flowmeters The flow controls are calibrated and adjustable for altitude to supply oxygen to either oxygen conserving cannulas or masks for altitudes up to the maximum operating altitude of the installed aircraft, or a maximum of 25,000 ft MSL. The System requires the pilot and passengers to don either an oxymizer cannula, standard cannula, or an oxygen mask first, then the pilot and passengers will open the oxygen valve, noting oxygen quantity, and subsequently set the flowmeter ball to the pressure altitude chosen for flight, or at a setting above the altitude chosen to meet the physiological requirements of the pilot. Figure 2 A4 Constant Flow Oxygen Flowmeter Figure 3 A5 Constant Flow Oxygen Flowmeter The flowmeters provide the means to distribute the appropriate amount of oxygen for the pressure altitude of flight and indicate the presence of oxygen flowing to the pilot and/or passengers. The flowmeter should be checked periodically (recommended intervals of less than 10 min) as well as the oxygen quantity gauge. The flowmeter should be readjusted with each change in pressure altitude or physiological requirement. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 8 of 47 Revision: C

This Supplement is applicable when supplemental oxygen is required by the applicable operating rules, and provides mounting instructions. Figure 4 Oxygen Flowmeter Caution Use of cannulas is recommended only for persons with a demonstrated ability to be properly oxygenated using these types of delivery devices. Precise Flight, Inc. encourages the use of a pulse oximeter (see Section 1.3) while using a supplemental oxygen system, as a person s physiological differences may alter oxygen saturation, and these effects may change day-to-day depending on health or respiratory challenges such as allergies, etc. Note When using a face mask, ensure a tight seal around the face. Users with facial hair should not use a face mask. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 9 of 47

1.2 PreciseFlow Oxygen Conservers (PFOC) The PreciseFlow Oxygen Conserver is a Demand Regulator calibrated and adjustable for altitude to supply oxygen to Standard Dual Lumen Cannulas or Dual Supply PFOC Masks for to a maximum operating altitude of 25,000 ft, or the maximum operating altitude of the aircraft whichever is lower. The system requires the pilot to don either a Dual Lumen Cannula or a PFOC Mask first, then the pilot will open the Oxygen Valve, noting oxygen quantity, and subsequently set the Altitude Dial to the pressure altitude chosen for flight, or at a setting above the altitude chosen to meet the pilot physiological requirements. Additionally the PreciseFlow Oxygen Conserver can be set to constant flow for additional oxygen when required. Figure 5 - PreciseFlow Oxygen Conserver Breathing Station Kit (with Dual Lumen Cannula and Standard Dual Supply Mask Shown) There are three major reasons for using the PreciseFlow Oxygen Conserver on a general aviation aircraft. One is the conservation of oxygen, allowing smaller portable or fixed oxygen bottles to be used or to increase the duration of usable oxygen for a given volume. The second is that the manner of delivery for a demand conserver is physiologically better. Third being that interrupted flow is better for the user s nasal passages. Conservation - Utilizing demand flow and interrupting the flow of oxygen can provide a potential savings of 3 fold over continuous flow systems. The three fold savings is derived FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 10 of 47 Revision: C

from a standard breathing cycle with 1/3 of the cycle being inhalation and exhalation taking the remaining 2/3. The PreciseFlow conserver defaults to constant flow with rapid breathing (breathing over 22 breaths per minute) as hysteresis in the mechanical system defaults the unit to constant flow. Delivery The ability to deliver a bolus of oxygen improves oxygen saturation by allowing the first air of the inhalation cycle to be more fully enriched with oxygen. It is this gas that participates in gas exchange in the lungs with the remainder of the breath providing the pressure to allow the gas to exchange across the lung surface into the blood. This bolus of oxygen can be felt and encourages the user to breathe through the nose. Comfort The ability to interrupt flow keeps the dry oxygen gas from flowing over the nasal passages continually. The lack of dry gas flow allows the nasal passages to remain moist. The comfort level encourages oxygen usage for people with sensitivity to nasal discomfort. The PreciseFlow Oxygen Conserver provides the means to efficiently distribute the appropriate amount of oxygen for the pressure altitude of flight, and indicate the presence of flowing oxygen to the pilot or passengers. The PreciseFlow Oxygen Conserver Flow Indicator and oxygen quantity gauge should be checked periodically at an interval of no more than every 10 min. The PreciseFlow Oxygen Conserver should be set for each change in pressure altitude or for personal physiological requirements. This supplement is applicable when supplemental oxygen is required by the applicable operating rules, and provides mounting instructions. The different mode combinations for the PreciseFlow Oxygen Conserver unit are shown in Figure 6 where the first picture shows a typical operation setting for flight between 16,000 ft and 22,000 ft. The unit is set to conserve using the mode select dial, and the altitude is set to 16K. Instructions provided to the user state that the PreciseFlow Oxygen Conserver should be adjusted to the next higher altitude from where flight is being conducted. Above 18,000 ft where a mask is required, constant flow is to be selected with a dual supply mask as indicated with a box around the altitudes on the altitude selection knob, and the constant on the mode select knob. If physiological requirements differ for the user, the constant mode, or a P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 11 of 47

higher altitude setting may be selected at any altitude. The THP setting is calibrated to flow 4LPM of Oxygen. This far exceeds the minimum flow requirement of 2.3LPM at 25,000ft should additional oxygen be required by the user. The conserve mode process is accomplished by an internal flow control disk that controls the flow of oxygen and a valve system controlled on the inhalation and exhalation cycles of the user within the unit. This breath cycle is sensed through the use of a dual lumen cannula, or the dual port mask. A calibrated orifice controls the flow rate is set by the altitude knob at the end of the unit. Figure 6 PreciseFlow Oxygen Conserver Mode Combinations Caution Use of cannulas recommended only for person who have demonstrated the ability to be properly oxygenated with these delivery devices. Precise Flight Inc. encourages the use of a pulse oximeter (see Section 1.3) while using supplemental oxygen system as peoples physiological differences can alter oxygen saturations from person to person. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 12 of 47 Revision: C

Figure 7 PreciseFlow Oxygen Conserver P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 13 of 47

1.2.1 Dual Lumen Cannula Use The Dual Lumen Cannula (See Figure 8) is for use with the PreciseFlow Oxygen Conserver only, and should not be used with other breathing equipment. This cannula is unique in that it provides both oxygen delivery and sensing to the PreciseFlow Oxygen Conserver. The sensing port is required to provide a pressure drop to the PreciseFlow during inhalation, signaling the conserver to provide oxygen through the deliver line. Figure 8 - Dual Lumen Cannula First attach the Dual Lumen Cannula to the PreciseFlow Oxygen Conserver, one tube connector to the Delivery side, and the other to the Sensing side as shown in Figure 9. Figure 9 - Attachment of the Dual Lumen Cannula to the PreciseFlow Oxygen Conserver FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 14 of 47 Revision: C

1. Please make sure you are wearing the cannula with the tab pointing down (found at the base of the nasal prongs - see Figure 10). TAB Pointing down Figure 10 - PreciseFlow Conserver Cannula Usage 2. Flow can be restricted if the small diameter tubes that lead to the nasal prongs on the cannula get pinched under a headset. The best solution is to put the cannula on over your headset so the tubes rest on the outside of the earpieces. 3. Adjust the PreciseFlow Oxygen Conserver to the desired altitude and breathe through the nose. Note Proper Oxygenation above 16,000 feet using the PreciseFlow Conserver and Dual Lumen cannula requires deliberate and consistent deep breathing through the nose. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 15 of 47

1.2.2 Dual Supply Demand Mask Use There are two dual supply mask options for use with the PreciseFlow Oxygen Conserver. Figure 11 Dual Supply Standard Mask Figure 12 Dual Supply Mask with Microphone To use a facemask, the PreciseFlow Oxygen Conserver must be set in the Constant flow mode. First attach the Dual Supply Mask to the PreciseFlow Oxygen Conserver, one tube connector to the Delivery side, and the other to the Sensing side as shown in Figure 13. Figure 13 - Attachment of the Dual Lumen Cannula to the PreciseFlow Oxygen Conserver FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 16 of 47 Revision: C

Wear the Face Mask per the instructions provided with the mask, and check the flow indicator to ensure that oxygen is flowing through the system. Note Do not use the PreciseFlow Oxygen Conserver with a bag reservoir Face Mask. Only Precise Flight Face Masks with a delivery and sensing line are approved for use with the PreciseFlow Conserver. Note When using a Face Mask, ensure a tight seal around the face. Users with Facial hair should not use a Face Mask. Caution Use of cannulas is recommended only for persons with a demonstrated ability to be properly oxygenated using these types of delivery devices. Precise Flight, Inc. encourages the use of a pulse oximeter (See Section 1.3) while using a supplemental oxygen system, as a person s physiological differences may alter oxygen saturation, and these effects may change day-to-day depending on health or respiratory challenges such as allergies, etc. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 17 of 47

1.3 Optional Pulse Oximeters Precise Flight Inc. recommends the following Nonin Pulse Oximeter models: Nonin Medical FlightStat Pulse Oximeter Nonin Medical GO 2 Achieve Pulse Oximeter 1.3.1 Optional Nonin Medical FlightStat Pulse Oximeter Caution Pulse Oximeter will read Carbon Monoxide as Oxygen and show false level of oxygen saturation. Caution This is a tool, and not a replacement for diligence of the user to notice the physiological signs of the onset of hypoxia caused by lack of oxygen, carbon monoxide poisoning, or other factors. The Nonin FlightStat Pulse Oximeter emits red and infrared light through the finger and detects the fluctuating signals caused by the pulsating blood flow. Pulse rate is determined from the signals received by a light detector. The ratio of the fluctuation between red and infrared light signals is used to calculate blood oxygen saturation (%SpO2) of hemoglobin. A pulse oximeter indicates a relative percent of hemoglobin molecules are carrying oxygen; blood oxygen saturation or %SpO2. A %SpO2 reading of 97 indicates that 97% of your hemoglobin molecules are carrying oxygen. At higher altitudes, %SpO2 decreases due to less oxygen available because of the decrease in air pressure. Physical exertion at high altitude may be difficult because of the reduced oxygen level. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 18 of 47 Revision: C

Pictoral of FlightStat FlightStat Key Features Figure 14 - Nonin Medical FlightStat Pulse Oximeter Two AAA-size batteries power the FlightStat for approximately 18 hours of measurement time (1,600 spot checks calculated at 40 seconds per spot check); it may be stored for approximately nine months. When the batteries are low, the numeric display flashes once per second. To conserve battery life, the FlightStat will automatically shut off approximately ten seconds after the finger is removed. This unit s advanced digital circuitry requires no calibration or periodic maintenance other than periodic battery replacement. 1.3.1.1 How to Use and Read the FlightStat 1 It is important to understand what each symbol and display means (See Figure 14Error! Reference source not found.): Blood Oxygen Saturation: Displays %SpO2 of blood. Pulse Rate: Displays the number of pulses per minute. Pulse Quality: Blinks green, yellow, or red to indicate changes in pulse quality. 1 For more information on the Nonin FlightStat visit http://www.flightstat.nonin.com/ P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 19 of 47

Inserting a finger into the FlightStat (see Figure 15) will automatically activate the device. Once the unit has been activated and has had time to determine the %SpO2 and pulse rate, the information is displayed. Precise Flight recommends periodic checks of the crew and passengers during flight at altitude, and adjusting oxygen use accordingly by increasing the altitude setting if a person feels any effects of hypoxia, or if the oxygen saturation is low. Figure 15 Finger Orientation For The FlightStat Note The FlightStat must be used on a bare finger without gloves, bandages, etc. as it requires a clear light path through the finger to properly function. 1.3.2 Optional Nonin Medical GO2 Achieve Pulse Oximeter Caution Pulse Oximeter will read Carbon Monoxide as Oxygen and show false level of oxygen saturation. Caution This is a tool, and not a replacement for diligence of the user to notice the physiological signs of the onset of hypoxia caused by lack of oxygen, carbon monoxide poisoning, or other factors. The Nonin GO 2 Achieve Pulse Oximeter emits red and infrared light through the finger and detects the fluctuating signals caused by the pulsating blood flow. Pulse rate is determined from the signals received by a light detector. The ratio of the fluctuation between red FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 20 of 47 Revision: C

and infrared light signals is used to calculate blood oxygen saturation (%SpO2) of hemoglobin. A pulse oximeter indicates a relative percent of hemoglobin molecules are carrying oxygen; blood oxygen saturation or %SpO2. A %SpO2 reading of 97 indicates that 97% of your hemoglobin molecules are carrying oxygen. At higher altitudes, %SpO2 decreases due to less oxygen available because of the decrease in air pressure. Physical exertion at high altitude may be difficult because of the reduced oxygen level. Pictoral of GO 2 Achieve GO 2 Achieve Key Features Figure 16 - Nonin Medical GO 2 Achieve Pulse Oximeter One AAA-size battery powers the GO 2 Achieve for approximately 21 hours of measurement time (2,400 spot checks calculated at 30 seconds per spot check); it may be stored for approximately six months. A battery indicator bar located in the lower portion of the front screen indicates the current battery charge level. To conserve battery life, the GO 2 Achieve will automatically shut off approximately ten seconds after the finger is removed. This unit s advanced digital circuitry requires no calibration or periodic maintenance other than periodic battery replacement. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 21 of 47

1.3.2.1 How to Use and Read the Nonin GO2 Achieve 2 It is important to understand what each symbol and display means (See Figure 16): Blood Oxygen Saturation: Displays %SpO2 of blood. Pulse Rate: Displays the number of pulses per minute. Pulse Quality: Displays changes in pulse quality. Inserting a finger into the Nonin GO 2 Achieve (see Figure 17) will automatically activate the device. Once the unit has been activated and has had time to determine the %SpO2 and pulse rate, the information is displayed. Precise Flight recommends periodic checks of the crew and passengers during flight at altitude, and adjusting oxygen use accordingly by increasing the altitude setting if a person feels any effects of hypoxia, or if the oxygen saturation is low. Figure 17 Finger Orientation For The GO 2 Achieve Note The GO 2 Achieve must be used on a bare finger without gloves, bandages, etc. as it requires a clear light path through the finger to properly function. 2 For more information on the Nonin GO 2 Achieve visit http://www.go2nonin.com/ FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 22 of 47 Revision: C

1.3.3 Optional Oxi-Go Non-Medical Oxi-Go Quickcheck Pro Pulse Oximeter Caution Pulse Oximeter will read Carbon Monoxide as Oxygen and show false level of oxygen saturation. Caution This is a tool, and not a replacement for diligence of the user to notice the physiological signs of the onset of hypoxia caused by lack of oxygen, carbon monoxide poisoning, or other factors. The Quickcheck Pro Pulse Oximeter emits red and infrared light through the finger and detects the fluctuating signals caused by the pulsating blood flow. Pulse rate is determined from the signals received by a light detector. The ratio of the fluctuation between red and infrared light signals is used to calculate blood oxygen saturation (%SpO2) of hemoglobin. A pulse oximeter indicates a relative percent of hemoglobin molecules are carrying oxygen; blood oxygen saturation or %SpO2. A %SpO2 reading of 97 indicates that 97% of your hemoglobin molecules are carrying oxygen. Oxygen Saturation Level Pulse Rate Pictoral of Quickcheck Pro Quickcheck Pro Key Features Figure 24 Oxi-Go Quickcheck Pro Pulse Oximeter At higher altitudes, %SpO2 decreases due to less oxygen available because of the decrease in air pressure. Physical exertion at high altitude may be difficult because of the reduced oxygen level. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 23 of 47

Two AAA-size batteries power the Oxi-Go Quick Check Pro. A low power indicator bar is located on the front screen indicating when the current battery charge is low. To conserve battery life, the Oxi-Go Quickcheck Pro will automatically shut off approximately eight seconds after the finger is removed. This unit s advanced digital circuitry requires no calibration or periodic maintenance other than periodic battery replacement. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 24 of 47 Revision: C

1.3.3.1 How to Use and Read the QuickCheck Pro 4 It is important to understand what each symbol and display means (See Figure 16): Blood Oxygen Saturation: Displays %SpO2 of blood. Pulse Rate: Displays the number of pulses per minute. Pulse Quality: Displays changes in pulse quality. Inserting a finger into the Nonin GO 2 Achieve (see Figure 17) will automatically activate the device. Once the unit has been activated and has had time to determine the %SpO2 and pulse rate, the information is displayed. Precise Flight recommends periodic checks of the crew and passengers during flight at altitude, and adjusting oxygen use accordingly by increasing the altitude setting if a person feels any effects of hypoxia, or if the oxygen saturation is low. Figure 18 Finger Orientation For The Quick Check Pro Note The QuickCheck Pro must be used on a bare finger without gloves, bandages, etc. as it requires a clear light path through the finger to properly function. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 25 of 47

1.4 Mask and Cannula Use This section lists the cannulas and mask uses approved with the installation of this STC. 1. Oxymizer Cannula and A4 or A5 Flowmeter to be used up to 17,500 ft MSL ONLY. 2. Standard Cannula and A4 or A5 Flowmeter to be used up to 17,500 ft MSL ONLY. 3. Dual lumen Cannula and PreciseFlow may to be used up to 17,500 ft MSL ONLY. 4. Standard Mask or Microphone Oxygen Mask and A4 or A5 Flowmeter or PreciseFlow may be used up to 17,500 ft MSL ONLY. 5. PreciseFlow Mask or PreciseFlow Microphone Oxygen Mask and PreciseFlow may be used up to 17,500 ft MSL ONLY. Section 2 Limitations The installation of this equipment does not affect or change the limitations of the airplane, which are detailed in Section 2 of the primary portion of the AFM/POH. However, the following limitations apply to operation of the. 1. A Mask and A4 or A5 Flowmeter or PreciseFlow must be used by persons experiencing nasal congestion, or with difficulty breathing through their nose. 2. Smoking is not permitted in the SR20 or SR22. 3. Placards On the individual Oxygen Masks and Oxygen Cannulas. Note DO NOT USE OXYGEN WHEN UTILIZING LIPSTICK, CHAPSTICK, PETROLEUM JELLY OR ANY PRODUCT CONTAINING OIL OR GREASE. Note FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 26 of 47 Revision: C

IF THE AIRCRAFT IS BEING OPERATED UNDER IFR AND THE PILOT HAS NASAL CONGESTION, A MASK WITH MICROPHONE SHOULD BE USED. Note SMOKING IS NOT PERMITTED IN THE SR20 OR SR22. The following portable oxygen systems and dispensing units are approved for use in the Cirrus Design SR20 or SR22: Table 1 Portable Oxygen System Componets Kit Model(s)* 003N0001-1 or 003N0001-2 Supplier Precise Flight, Inc. Bend, Oregon, Untied States of America Capacity 22 cuft Flow Devise A4, A5 PFOC Dispensing Unit Options Oxymizer Cannula Standard Cannula Standard Constant Flow Mask Microphone Constant Flow Mask Dual Lumen Cannula PFOC Standard Mask PFOC Microphone Mask * STC Installation Kits noted, Dispensing Units listed may be replaced individually by the Precise Flight, Inc. Products listed. Note The FAA, under 14 CFR Part 23 Regulations, require the complete Oxygen System (including the breathing stations, flowmeters, cannulas, and masks) be certified as a complete System. The use of other breathing equipment in conjunction with the built-in portion of the System has not been tested, nor is it FAA-Approved. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 27 of 47

Section 3 Emergency Procedures 3.1 General If the Semi-Portable oxygen ceases to provide adequate oxygen for the altitude indicated on the flowmeter, DESCEND IMMEDIATELY BELOW 12,500 FT. PA. Close the oxygen supply valve. If the system should malfunction or perform improperly, do not attempt to identify or analyze the problem, DESCEND IMMEDIATELY BELOW 12,500 FT. PA. Close the oxygen supply valve. The installation of this equipment does not affect or change the emergency procedures of the airplane, which are detailed in Section 3 of the primary portion of the Pilot s Operating Handbook. 1. Oxygen OFF or AS REQUIRED for Smoke in the Cabin. 2. Oxygen OFF for Cabin Fire. Caution It is the pilot s responsibility to safely descend to a lower altitude. The pilot may have to reroute flight path to avoid terrain or other hazards. 3.2 Smoke and Fume Elimination In addition to the procedures outlined in the basic Handbook, pilot and passengers should don masks and use oxygen at the maximum flow rate until smoke and fumes have cleared. Note The Pilot must use their discretion in Oxygen use as not to cause a hazard if an in-cabin fire causes smoke. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 28 of 47 Revision: C

Section 4 Normal Procedures 4.1 General The normal procedures for takeoff, climb, cruise, descent, and landing, which are detailed in Section 4 for the POH should be used. The following additional items must be incorporated into the Normal Checklists as applicable when the Oxygen System is in-use. The installation of this equipment does not affect or change the normal procedures or Performance of the airplane, which is detailed in Section 4 of the primary portion of AFM/POH except as, noted above. Note Refer to Section 5 for Oxygen Duration for duration at various altitudes and passengers using oxygen. 4.2 Preflight 1. Oxygen Bottle (Center Rear Seats)... Check Properly Secured And Verify Straps are in Good Condition 2. Oxygen Bottle Valve... Open 3. Oxygen Bottle Gauge... Check for Quantity / Pressure 4. Oxygen Masks or Cannulas... Check for Rips, Tears, or Blockage 5. Oxygen Masks or Cannulas... Connected to Regulator 6. Flowmeter... Internal Ball Moves when Held Vertical 7. PreciseFlow... Flow indicator indicating flow during breath cycle. 8. Oxygen Bottle Valve Close.. If Oxygen Not Required or Preferred Note The flowmeter must be held vertically when adjusting flow rate or reading. Note Reading is taken at the Midpoint of the Ball. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 29 of 47

4.3 Before Starting Engine (If Oxygen is required or preferred) 1. Passengers... Brief on Oxygen System Operation Note Briefing to include oxygen mask/cannula donning, flowmeter and/or PreciseFlow adjustment, and connection to oxygen bottle regulator. 2. Oxygen Masks & Cannulas... Don 3. Flowmeter... Set to the Intended Cruise Altitude 4. PreciseFlow... Set to Intended Cruise Altitude 4.4 Enroute (If Oxygen is required or preferred) 1. Flowmeter...Periodically Check the Flowmeter Note Check Flowmeter or Flow Indicator at Less than 10 min Intervals to Ensure Proper Settings and Flow. Note The flowmeter must be held vertically when adjusting flow rate or reading. Note Reading is taken at the Midpoint of the Ball and set to the proper setting corresponding to the altitude flown. 2. Flowmeter... Adjust as Necessary 3. PreciseFlow... Periodically Check the Flow Indicator 4. PreciseFlow... Adjust as Necessary 5. Flexible Oxygen Lines... Insure free flow of Oxygen 6. Pilot & Passengers... Limit Conversation 7. Pilot & Passengers... Breath Through the Nose if Using a Cannula FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 30 of 47 Revision: C

4.5 Shutdown 1. Oxygen Bottle Valve... Close 2. Flowmeter... Leave Open until Pressure is Relieved 3. PreciseFlow... Turn to Constant Mode to relieve pressure 4. Lines, Flowmeters, PreciseFlow, Masks... Stow Safely Until Next Flight Note Ensure the Oxygen System is turned OFF prior to aircraft shutdown to preserve oxygen quantity. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 31 of 47

Section 5 Performance Oxygen Duration Charts are provided below for Flight Planning Purposes. The installation of this equipment does not affect or change the performance characteristics of the airplane, which are detailed in Section 5 of the primary portion of the AFM/POH. 5.1 Oxygen Bottle Capacity vs. Pressure Following Boyle s law, the bottle pressure vs. capacity is linear thus the actual quantity left (bottle Pressure) can be noted and the duration charts in this section adjusted. Capacity Factor 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 Bottle Pressure vs Capacity Factor 0 200 400 600 800 1000 1200 1400 1600 1800 2000 Bottle Pressure (psig) EXAMPLE: Figure 19 - Bottle Pressure/Capacity Factor Graph The pilot and 1 passenger are planning a flight at 16,000ft, using 2 PFOC Demand Conservers in the Conserver Mode with a Bottle Pressure of 1500psig. What is the available duration at this setting? From Figure 19, for 1500psig the Capacity Factor is 0.75. From Figure 24 the duration for two active users is 5hrs. The duration available is calculated by multiplying the duration by the Capacity Factor. Thus the actual available duration is 5hrs * 0.75 = 3.75hrs for this flight. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 32 of 47 Revision: C

5.2 A4 Constant Flow Meter with Oxymizer Oxygen Conserving Cannula Usage Altitude (Ft * 1,000) 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 0.00 Figure 20 - A4 Flowmeter (Oxymizer and STD Scales) Duration Chart Notes: Oxygen System Usage Duration - A4 Flowmeter (STD) Standard Cannula/Mask - (OXY) Oxymizer Cannula Tested Values at Altitude for flow rates STPD (22 Cu. Ft. Serviced to 2,000 PSIG -5%), Flow Rates are For Reference Only 1.00 2.00 3.00 4.00 5.00 Bottle Capacity has been reduced 5% for safety 6.00 7.00 8.00 9.00 The installation of this equipment does not affect or change the performance characteristics of the airplane, which are detailed in Section 5 of the primary portion of the Pilot s Operating Handbook. No change from basic Handbook. 10.00 11.00 12.00 Hours of Available O2 ABOVE 18,000FT MASK ONLY 13.00 Masks or Cannulas Below 18,000FT Masks required if user has Nasal Blockage or Congestion. 1 PERSON - STD 2 PERSONS - STD 3 PERSONS - STD 4 PERSONS - STD 1 PERSON - OXY 2 PERSONS - OXY 3 PERSONS - OXY 4 PERSONS - OXY 14.00 15.00 16.00 17.00 18.00 19.00 20.00 P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 33 of 47

5.3 A4 Constant Flow Meter with Standard Cannula or Constant Flow Mask Usage Altitude (Ft * 1,000) 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 0.00 Oxygen System Usage Duration - A4 Flowmeter Standard Cannula/Mask Tested Values at Altitude for flow rates STPD (22 Cu. Ft. Serviced to 2,000 PSIG -5%), Flow Rates are For Reference Only 1.00 2.00 3.00 4.00 5.00 ABOVE 18,000FT MASK ONLY 6.00 Masks or Cannulas Below 18,000FT Masks required if user has Nasal Blockage or Congestion. 7.00 8.00 9.00 10.00 Hours of Available O2 1 PERSON - STD 2 PERSONS - STD 3 PERSONS - STD 4 PERSONS - STD Figure 21 - A4 Flowmeter (STD Scale) Duration Chart Notes: Bottle Capacity has been reduced 5% for safety The installation of this equipment does not affect or change the performance characteristics of the airplane, which are detailed in Section 5 of the primary portion of the Pilot s Operating Handbook. No change from basic Handbook. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 34 of 47 Revision: C

5.4 A5 Constant Flow Meter with Oxymizer Oxygen Conserving Cannula Usage Altitude (Ft * 1,000) 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 0.00 Oxygen System Usage Duration - A5 Flowmeter (STD) Standard Cannula/Mask - (OXY) Oxymizer Cannula Tested Values at Altitude for flow rates STPD (22 Cu. Ft. Serviced to 2,000 PSIG -5%), Flow Rates are For Reference Only 1.00 2.00 3.00 4.00 5.00 6.00 Figure 22 - A5 Flowmeter (Oxymizer and Standard Scales) Duration Chart Notes: Bottle Capacity has been reduced 5% for safety 7.00 8.00 9.00 10.00 11.00 12.00 The installation of this equipment does not affect or change the performance characteristics of the airplane, which are detailed in Section 5 of the primary portion of the Pilot s Operating Handbook. No change from basic Handbook. 13.00 14.00 15.00 16.00 Hours of Available O2 ABOVE 18,000FT MASK ONLY Masks or Cannulas Below 18,000FT Masks required if user has Nasal Blockage or Congestion. 1 PERSON - STD 2 PERSONS - STD 3 PERSONS - STD 4 PERSONS - STD 1 PERSON - OXY 2 PERSONS - OXY 3 PERSONS - OXY 4 PERSONS - OXY 17.00 18.00 19.00 20.00 21.00 22.00 23.00 24.00 25.00 P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 35 of 47

5.5 A5 Constant Flow Meter with Standard Cannula or Constant Flow Mask Usage Altitude (Ft * 1,000) 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 0.00 Oxygen System Usage Duration - A5 Flowmeter Standard Cannula/Mask Tested Values at Altitude for flow rates STPD (22 Cu. Ft. Serviced to 2,000 PSIG -5%), Flow Rates are For Reference Only 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 Hours of Available O2 13.00 14.00 ABOVE 18,000FT MASK ONLY Masks or Cannulas Below 18,000FT Masks required if user has Nasal Blockage or Congestion. 1 PERSON - STD 2 PERSONS - STD 3 PERSONS - STD 4 PERSONS - STD 15.00 16.00 17.00 18.00 19.00 20.00 21.00 22.00 23.00 24.00 25.00 Figure 23 - A5 Flowmeter (Standard Scale) Duration Chart Notes: Bottle Capacity has been reduced 5% for safety The installation of this equipment does not affect or change the performance characteristics of the airplane, which are detailed in Section 5 of the primary portion of the Pilot s Operating Handbook. No change from basic Handbook. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 36 of 47 Revision: C

5.6 PreciseFlow Oxygen Conserver (PFOC) Normal Operation 25 Note Pilot should calculate flow consumption based on Active use for flight crew. Actual flow consumption rates will vary from person to person when in conserve mode. Caution Mask and Constant Flow Mode required above 18,000ft. Oxygen System Usage Duration - PFOC Conserver (Demand) Flow up to 18,000ft, Constant Flow 18,000ft to 25,000ft (22 Cu. Ft. Serviced to 2,000 PSIG -5%) Flow Rates arestpd and For Reference Only 24 23 22 21 ABOVE 18,000FT MASK ONLY AND PFOC SET ON CONSTANT FLOW ONLY Usage Altitude (Ft * 1,000) 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 Masks or Cannulas Below 18,000FT Masks required if user has Nasal Blockage or Congestion. 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 14.00 15.00 16.00 17.00 18.00 19.00 20.00 21.00 22.00 23.00 24.00 25.00 Hours of Available O2 1 PERSON - PFOC 2 PERSONS - PFOC 3 PERSONS - PFOC 4 PERSONS - PFOC 1 PERSON - PFOC (RESTING) 2 PERSONS - PFOC (RESTING) 3 PERSONS - PFOC (RESTING) 4 PERSONS - PFOC (RESTING) 26.00 27.00 28.00 29.00 30.00 31.00 32.00 33.00 34.00 35.00 36.00 37.00 38.00 39.00 40.00 41.00 42.00 43.00 44.00 45.00 46.00 47.00 48.00 49.00 50.00 Figure 24 - PreciseFlow Oxygen Conserver Duration Chart Notes: Bottle Capacity has been reduced 5% for safety The installation of this equipment does not affect or change the performance characteristics of the airplane, which are detailed in Section 5 of the primary portion of the Pilot s Operating Handbook. No change from basic Handbook. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 37 of 47

Section 6 Weight & Balance If the aircraft is equipped and the system is installed, it is the pilot s responsibility to verify that the weight and balance of the aircraft is within limits with the system installed prior to flight. The weight, arm, and moment for fully charged systems (1800 2200 psi) are provided in the Table 2. Table 2 - Weight and Balance Information Model Weight - lb Arm Moment/1000 003N0001-1 Or 003N0001-2 13.00 170 2.21 Section 7 System Description The general operating procedures for use of the Semi Portable Oxygen System is discussed in the Section 1 - General of this supplement. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 38 of 47 Revision: C

Section 8 Handling, Service, & Maintenance 8.1 Support/Strap Mounting Instructions The Support and Strap may be removed and installed as required. The Assembly MUST be installed to install the Oxygen Bottle/Regulator assembly if supplemental Oxygen is required for flight. Note Installation must be accomplished prior to flight requiring supplemental oxygen. See Figure 27 for bottle mounting instructions. Bottle and Regulator (Strap not shown for Clarity) Support and Strap Attachment Shown Exploded, Strap should not have to be removed for Normal Installation See Figure 26 for Installation Detail Figure 25 - Support and Bottle Installation P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 39 of 47

Install and Torque Machine Screw to 25 in/lbs Figure 26 - Installation Detail for Bracket Mounting to Floor 8.2 Bottle Mounting Instructions The oxygen bottle must be properly mounted between the rear passengers seats using the cylinder harness supplied with the system. Slip the Oxygen Bottle - regulator end through the harness so that the pilot will be able to view the oxygen pressure gage and operate the shutoff valve. Secure with the buckle. Tighten the buckle until the webbing lays taught and smooth. See Figure 27 for bottle mounting instructions. Ensure Bottle is Secure and Webbing is snug. Tighten at Buckle as Necessary Note Location of Pressure Gage Figure 27 - Bottle Installation 8.3 Refilling the Oxygen Bottle 1. Turn Oxygen Supply Valve Clockwise to OFF. 2. Open Flowmeter to Bleed Off System Pressure. Failure to do so will destroy the sealing o-ring when the regulator is removed. 3. Remove Regulator and set aside. (See Figure 28) FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 40 of 47 Revision: C

4. Remove bottle from the aircraft and refill. Full bottle pressure is dependent on temperature and should be between 1800 and 2200 psig at a rate of 200psig per minute maximum. Caution Clean both the oxygen supply line and the filler port to ensure it is clear of oils, dirt, etc., that may create a fire hazard during refilling. Check threads and ensure the filling port fitting threads are not damaged. Caution Excessive fill rates create heat buildup in the high pressure parts of the System, especially the bottle. Excessive heat buildup will result in damage to the bottle, and may lead to fire. Care must be taken during refilling of the Oxygen System. 5. Place bottle into the Oxygen Mounts. 6. Install per the placard & Cinch Restraint Strap 7. Screw on Regulator FINGER TIGHT Only Oxygen pressure insures a Seal. DO NOT LUBRICATE THREADS (See Figure 28) Figure 28 - Regulator Installation to Bottle 8. Open Bottle Valve Clockwise and Check Bottle Pressure. 9. Close Bottle Valve and Open Flowmeter to Bleed System Pressure. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 41 of 47

10. If Supplemental Oxygen is required, prior to flight install Support, and Bottle into Strap, as per Section 8. 8.4 Oxygen Component Cleaning Periodically clean the oxygen breathing equipment with Purell http://www.pfizerch.com or warm water. As you clean the equipment pay close attention to the condition of the lines and silicone moldings to ensure no tears or kinks have occurred. Carefully restore oxygen components. 8.4.1 Flowmeter Anti-Static Periodic anti-static treatment may be required on the flow meter should the ball act sticky or function erratically. This is caused by the handling of the flowmeter and a simple cleaning is required. The use of de-ionized water with very mild oxygen and breathing safe detergent is needed. Remove the cannula or mask and add a few drops of this solution in the end of the tube and let it reach the tapered tube of the flowmeter. Then run clean oxygen through the flowmeter until dry. The flowmeter is then ready for use. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 42 of 47 Revision: C

Section 9 Instructions for Continued Airworthiness 9.1 Introduction The content of this section provides the Instructions for Continued Airworthiness for the Cirrus Design Models SR20 and SR22 Semi- Portable Oxygen System Installation. This section is FAA approved and specifies the maintenance required per 14 CFR Sections 23.1526, Part 23 Appendix G, 43.16, and 91.403. Because a majority of the installation does not affect the standard airworthiness of the aircraft, only the key items that exist different are noted in this section. All structure and general maintenance must be performed in accordance with existing approved maintenance practices, or the aircraft maintenance manual. 9.2 Changes to Instruction for Continued Airworthiness Changes made to this section are done by new revisions to this supplement as documented in the Table of Revisions, by service letters or service bulletins from Precise Flight or the Cirrus Design Corporation, or by notice from the Federal Aviation Administration by means of an Airworthiness Directive. 9.3 System Description Refer to section 1.0 of this supplement for a complete description of this system. 9.4 Specialty Tools Required None No Special Tools are required for normal maintenance. Specific items such, as hydrostatic testing, and regulator overhaul are not done in the field. 9.5 Maintenance Instructions Refer to section 8 for standard maintenance instructions. For structural installation reference, refer to Precise Flight Drawing list 003N0000. P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 43 of 47

9.6 Troubleshooting Guide Please contact Precise Flight for questions not answered by this supplement. 9.7 Airworthiness Limitations This system must be inspected prior to flight per section 4.0 of this supplement. Follow scheduled maintenance per section 9.8 to maintain system within airworthiness limits. Refer to section 2.0 of this supplement for the operational limitations. FAA Approval Date: P/N 11934-S09 Initial Issue of Supplement: 6/27/2003 PFI Document: 003NMAN0001 Page 44 of 47 Revision: C

9.8 Scheduled Maintenance Intervals and Inspections for Continued Airworthiness This section includes the inspection intervals, and requirements, for maintenance of the Cirrus Semi-Portable Oxygen system when installed in the Cirrus SR20 or SR22 Aircraft. The breakdown of required inspections is listed in Table 3. Table 3 - Scheduled Maintenance 5 YEARS 3 YEARS ANNUALLY EACH 500 HOURS OF USE EACH 200 HOURS OF USE EACH 100 HOURS OF USE EACH 50 HOURS OF USE 1. Check Oxygen Bottle for Condition Security Mounting 2. Check flexible lines for security of connections, Kinks or tube discoloration 3. Replace Oxygen Cannulas and/or Standard Oxygen Masks 4. Replace Oxygen Mask and Tubing (Microphone replaced on Condition) 5. Replace O-Ring in Connector Assembly 6. a. Remove and Hydrostatically Test the Oxygen Cylinder from date stamped on cylinder b. Overhaul 300M Regulator c. Replace Flexible oxygen lines d. Overhaul A4 or A5 Flowmeter e. Overhaul PreciseFlow Oxygen Conserver f. Recalibrate and Overhaul Oxygen Pressure Gauge P/N 11934-S09 FAA Approval Date: PFI Document: 003NMAN0001 Initial Issue of Supplement: 6/27/2003 Revision: C Page 45 of 47