Heliox TM. He systems to suit all applications

Similar documents
Heliox Sorption Pumped 3 He Refrigerator Systems

Vacuum. Dry Turbo Pumping Stations. Roughing Pumps for 1 K Helium Pots and Lambda Refrigerators. Hermetically Sealed Pumps for He3 Recirculation

attoliquid Liquid Research Cryostats

Current Leads for Cryogenic Systems

SPECIFICATION FOR AN MRBR 9.4 TESLA/310MM/AS CRYO-COOLED MAGNET SYSTEM

RC102 & RC110 Sample in Vacuum Continuous Flow Cryogenic Workstation Cryostats

Oxygen Contamination

Microscopy Cryogenic WORKSTATION. Performance by Design

CRYO. SuperVariTemp Magnet Inserts

JANIS OPERATING INSTRUCTIONS FOR SUPERCONDUCTING MAGNET CRYOSTATS

Variable Temperature Storage Dewar Mount Inserts

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

Customer Responsibilities

Cryostream 800 Series

Pump out insert (condenser and still lines) overnight with turbo pump

Development of High Efficiency 4K Two-Stage Pulse Tube Cryocooler

OptistatCF TM. Continuous helium flow cryostat, sample in exchange gas. Features and Benefits. Components. Creating environments for physical sciences

Oxford Instruments Austin, Inc.

Series Environmental Chambers

ATL. Take Control of your Helium Supply. Advanced Technology Liquefier The next generation of helium recycling

Table of Contents Want full page pictures with most important parts labeled in the beginning.

Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01

Customer Responsibilities

Superconducting Susceptometer (MPMS-5S) Quantum Design Room 296 (MPMS)

INTRODUCTION. The Quantum Technology system has the following advantages:, as it does not need plastic gas-bags which are volume-consuming,

Magnet and RF Cavity Test Stand Design. Tom Peterson, SLAC USPAS January, 2017

PURCHASE AND DELIVERY OF A HELIUM CLOSED-CYCLE OPTICAL CRYOSTAT. The present tender is only an unofficial translation provided as a courtesy.

AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER

Specifications for the CMI 2409 Magnetocardiograph

Dilution Refrigerator manual

Dynamic Operation of a 4 K Pulse Tube Cryocooler with Inverter Compressors

Level MEASUREMENT 1/2016

FAILURE SCENARIOS AND MITIGATIONS FOR THE BABAR SUPERCONDUCTING SOLENOID

Oxford Instruments Austin, Inc.

An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler

TIGHTNESS. Glass sealing Thanks to our glass-sealing technology, ODU products can meet the most demanding tightness requirements.

EXPERIENCE WITH A PRE-SERIES SUPERFLUID HELIUM TEST BENCH FOR LHC MAGNETS

First Experimental Data of the Cryogenic Safety Test Facility PICARD

Physical Property Measurement System

AC : ACCURATE CRYOCHAMBER FOR A SMALL LABORATORY WITH SMALL BUDGET

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Variable Temperature Operation

PRC CO ² -LASER PRESENTATION

Liquid Helium Bath Cryostat

BUYER S GUIDE AQUAlogger 530WTD

In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure

CRYO INDUSTRIES. Liquid Helium Research Dewars

Major Design Features

VACGEN. Vacuum Components. Product Overview

Customer Responsibilities

DD2 Site Preparation Checklist Hardware Site Preparation Specification

RDK-408D2 Cold Head. Technical Manual. SHI-APD Cryogenics Inc Vultee Street Allentown, PA U.S.A. Revision A: September 2005

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids

OLED vacuum deposition cluster system Sunicel Plus 400 / Plus 400L (Sunic Systems)

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

MULTIPROBE. A Family of Multi-Technique UHV Surface Science Systems

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

GasSense NDIR User Manual

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Sartorius CCL kg Prototype Mass Comparator

Overview of Earlier Lecture

Cryogenics of SRF Spoke Cavity Development at SMTF

FAILURE AND HAZARD ANALYSIS OF THE NPDGAMMA LH2 TARGET SYSTEM

IMECE IMECE2011-6

The Broadest Gauging Line in the Industry

BUYER S GUIDE AQUAlogger 520

Revision 2013 Vacuum Technology 1-3 day Good Vacuum Practice 1 Day Course Outline

Transition your department towards more productive helium-free MR operations 1

Fermilab MTF Cryogenic System & Vertical RF Cavity Test Facility. Yuenian Huang, on behalf of Fermilab, TD/TID May 11, 2006

STARLOG. Capacitive Water Depth Probe

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

Hitachi Differential Pressure/Pressure Transmitter

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Customer Responsibilities

Oxford Instruments Plasma Technology

Chemistry - Scale-up F.32. Lara TM - Controlled - Lab Reactor. The Concept

EXPERIMENT XI. Careful!! Improper handling of the vacuum line may result in the release of SO 2 which is an irritating and suffocating gas.

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

Pycnomatic ATC For solids and powders density

BIMA cryogenics (Dick Plambeck, 18jan2007)

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

80% Less installation time with just two welds for fast and efficient installation.

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Storage and transfer of cryofluids

Trillium US Inc. Cryo-Plex 10 Cryogenic High Vacuum Pump User s Manual Rev A / November 2015

RHIC CRYOGENIC SYSTEMS MAINTENANCE PROGRAM

Model nd Order SQUID Gradiometer System

Ascend. User Manual. Innovation with Integrity. Version NMR

The Principles of Vacuum Technology

Easy with a modular concept for future expansion

T EK-SUB 4800C 19 mm Submersible Level Transmitter

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Ascend DNP. User Manual. Innovation with Integrity. Version NMR

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

To be published in the proceeding of ICEC-22, Seoul Korea, July 2008 MICE Note 231 1

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

Transcription:

Heliox TM He systems to suit all applications heliox

eliox Which Heliox is right for you? When choosing a Heliox system, there are technical parameters that you need to consider in order to achieve the desired instrumentation for your research. The Heliox range of single shot He refrigerators offers the best combination of specification, experimental access and flexibility. Advances in sorption pump technology reduce base temperature and helium consumption and increase cooling power. In addition, Oxford Instruments can design tailored He refrigerators to suit your particular experimental requirements. All models include a control system which can be operated stand-alone or integrated into a PC controlled measurement system via LabVIEW TM. There are four products to choose from in the Heliox family: System Selection Experiments at temperatures around 00 mk with single-shot He refrigerators Quick turnaround time Ease of use Compact size Multi-experiment or multiuser experimental access Sample in liquid environment Neutron or X-ray scattering experiments No liquid He in horizontal sample path NO NEED FOR LIQUID HELIUM Low maintenance Compact HelioxVL HelioxTL HelioxVT HelioxAC-V Heliox

heliox Base temperature The base temperature, quoted in mk, is achieved with no heat load applied. Cooling power Cooling power is dictated by the He evaporation rate and consequently the pumping speed of the system. The cryogenic sorption pump technology used in the Heliox family provides an extremely high pumping speed in a much reduced system size. The cooling power is quoted at 00 mk. Hold time Expressed in hours, hold time is governed by the total heat load on the He pot and the total charge of He condensed inside the pot. Regeneration time This parameter indicates the preparation time required before being able to restart the experiment. Sample environment options In vacuum environment, the sample is accessed by removing the insert from the cryostat, warming to room temperature and removing the inner vacuum chamber (IVC) tail. In liquid environment, the sample or experimental setup is mounted on a measurement probe. The probe can be loaded or removed from the insert whilst the main insert remains cold. This design flexibility reduces turnaround time and enables multi-user capability. Experimental access Inserts are provided with spare ports to give additional access, featuring either line of sight access to He pot, IVC, or spare ports for additional wiring to the insert/experimental probes. Inserts can be utilised with a range of wiring options and sample positioning devices. Optical access is also available, plus interfaces with SPM heads and pressure cells. Research Areas Applications Experimental Techniques Semiconductors Quantum Hall effect Quantum dots Single electron tunneling Quantum computing Magneto-resistance Hall effect RF transport High frequency conductivity Solid state physics Superconductivity Astrophysics & cosmology Metrology Heavy fermion systems Metal insulator transition Spin glass Mesoscopic systems Giant magnetic resistance Low T c superconductors Quantum computing Josephson junctions Flux vortices Quantum initial phenomena Low temperature detectors Superconducting tunnel junctions Ge bolometers Quantum hall effect Voltage standards Current standards Specific heat De Haas-van Alphen oscillations Solid state NMR Electrical resistivity Magneto-resistance Neutron scattering Electrical resistivity Scanning spectroscopy (STM/AFM) Squids AC susceptibility Electrothermal measurements Voltage biased measurements Low energy photon detection Magneto-resistance DC & AC low frequency transport and magnetic measurements Single electron tunneling Heliox

eliox HelioxVL Line of sight ports 50 mm connector Sample in vacuum He dump Performance unrivalled by any other He system: 245 mk for more than 90 hours (with no applied heat load). Achieved using advanced sorption pump technology combined with the specially engineered 1K condenser and He pot More than 40 μw cooling power at 290 mk for over 10 hours Quick sample change: the insert is compact allowing rapid thermal cycling when changing samples, making it ideal for fast sample characterisation High temperature option available: the integrated sliding seal enables operation at temperatures close to 00 K (100 K when the system is used with a superconducting magnet) Compact design: Self-contained dump and He pumping system reduce footprint, meaning less laboratory space is required Low maintenance: In-built cryopump technology traps contaminants so no blockages occur during operation Low intrinsic vibration: The combination of the cryogenic pump and the 1 K coil type of condenser provides an excellent environment for vibration-sensitive techniques Compatible with liquid helium storage vessels or dewars with neck diameter of 52 mm Greased cone sealing for the IVC and the integrated He dump mean the system is easy to use Sliding seal IVC flange (cone sealing) Sorption pump 1.5 K condenser Magnetic field configurations He pot For magnetic fields over 6 T: the HelioxVL is combined with magnetic environments within the Integra TM product range. This range uniquely integrates environments together under software control and provides magnetic fields up to 21 T. For magnetic fields below 6 T and when the cryostat is used in a transport dewar: a small magnet is mounted onto the IVC tube and provides magnet operation in persistent mode (not suitable for sustained field ramping). Heliox

HelioxVT Helio Sample in vacuum, no 1K pot Line of sight to IVC He dump 50 mm universal connector block Clamp 00 mk for more than 40 hours (with no applied heat load) 50 μw cooling power at 50 mk for over 6 hours Extension of the temperature range below 00 mk of existing or new Variable Temperature Insert (VTI) with 0 or 50 mm access No liquid helium in the sample horizontal path as it operates in the cold environment of a VTI. This is ideal for neutron or X-ray scattering applications Sliding seal tube to suit VTI To find out more about the Heliox range of products, including applications and modes of operation please visit our website at www.oxford-instruments.com Radiation baffles Sorption pump 1.5 K condensing stage (pot-free design) IVC flange (cone sealing) IntegraAC Cryostat Magnet and support HelioxVL HelioxTL VTI He pot

xhelioxtl Top-loading into liquid 260 mk for more than 50 hours (with no applied heat load) 400 μw cooling power at 00 mk for over 6 hours Top loading into the mixture ensures good thermalisation and high stability of the thermal environment Quick and easy sample change: the sample fitted on the top loading probe can be removed quickly while the insert remains cold. A vacuum lock mechanism ensures there is no loss of He or entry of air into the sample space Multi-service access provides a unique platform that can be used with a range of sample probes, such as Swedish rotators and high frequency coaxial lines Extremely compact design fitting the standard and extended length dewars of the Oxford Instruments range Minimum room height requirements are.7 m with SMD10/15VS cryostat and 4.1 m with SMD10/15VSEX cryostat Vacuum lock value Experimental probe access Combined low temperature and magnetic field sample environments: The HelioxVL, HelioxTL and HelioxVT can be integrated into complete cryomagnetic systems. Magnet configurations provide fields from 8 T at 4.2 K to 21 T at 2.2 K, field homogeneity of 0.1 % over a 10 mm diameter spherical volume. The HelioxAC-V can be integrated with Cryofree magnet options for a complete Cryofree solution. Solution to helium rising costs: The HelioxVL, HelioxTL and HelioxVT are compatible with the IntegraAC, recondensing liquid helium cryostat. This product has been developed to significantly reduce the consumption of liquid helium by recondensing helium gas evaporated within the system, which would otherwise be vented from the cryostat. This decreases the frequency of helium refills. Cryogenic systems can be kept cold continuously, even when in stand-by mode, leading to greater freedom to schedule experimental time. 4.2 K flange Sorption pump He pot/tail

heliox HelioxAC-V Cryofree Achieves 00 mk without the need for liquid helium! Large sample environment enabling integration of complex Enables operation in laboratory which would not normally experimental set-ups support cryogenic equipment Built in cryogenic pump technology traps contaminants, Hold time of more than 50 hours enabled by patented so no blockages occur during operation adiabatic multi-expansion He refrigeration technology Wide temperature range: 00 mk to 00 K as standard (US patent 6782712, European patent application making this an extremely versatile instrument 1871 and Japanese patent application 200416089) Can be integrated into a Cryofree magnet for a complete High temperature stability (± mk at < 2 K) provides an Cryofree solution extremely stable temperature environment Small footprint enables use in virtually any laboratory environment. (0.4 m diameter by 0.85 m height) PTR cold head Electrical connectors Dr Enrique Diez of the University of Salamanca in Spain is using a special HelioxAC-V with a 12 T Cryofree magnet for magnetotransport of nanolectric devices. He dump PTR first stage thermal link & shield connection Adsorption pump PTR second stage thermal link & shield connection He pot & sample mounting plate Heliox

iservice heliox A global reach By choosing Oxford Instruments as the supplier of your next He system, not only are you getting a reliable product but also access to a service support team. This includes: Our team of more than ten expert service engineers have more than 100 years of experience, based on the successful installation of hundreds of magnet and low temperature systems Five people dedicated to helpdesk Bespoke Cryospares service ServiceWise extended warranty Oxford Instruments offers a standard 12-month warranty on all products. You can also upgrade this cover and purchase extended warranty. Warranty covers parts, labour, return from the factory and third-party items and on-site service if required. We can also loan control electronics and pumps, subject to availability. ServiceWise service contract for complete peace of mind The HelioxAC-V uses a pulse tube refrigerator, a compressor and a circulation pump which require regular maintenance to ensure optimum performance. Oxford Instruments offers support packages which can take care of this for you. visit www.oxford-instruments.com for more information Oxford Instruments NanoScience For more information please email: nanoscience@oxinst.com UK Abingdon, Oxfordshire Tel: +44 1865 9 200 China Shanghai Tel: +86 21 6490 8280 Germany Wiesbaden Tel: +49 6122 97 171 Italy Pieve Emanuele, Milan Tel: +9 5 778794 Japan Tokyo Tel: +81 5245 261 USA Concord, MA Tel: +1 978 69 99 www.oxford-instruments.com This publication is the copyright of Oxford Instruments plc and provides outline information only, which (unless agreed by the company in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or regarded as the representation relating to the products or services concerned. Oxford Instruments policy is one of continued improvement. The company reserves the right to alter, without notice the specification, design or conditions of supply of any product or service. Oxford Instruments acknowledges all trademarks and registrations. Oxford Instruments plc, 2011. All rights reserved. Part no: OINS/HELIOXOINS/2011/06