UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO B WABASHA STREET SOUTH BOUND (MASA 235 SB)

Similar documents
UNDERWATER BRIDGE INSPECTION REPORT METRO DISTRICT - ANOKA COUNTY

UNDERWATER BRIDGE INSPECTION REPORT DISTRICT 1 PINE COUNTY

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO CSAH NO. 9 OVER THE BLUE EARTH RIVER DISTRICT 7 - BLUE EARTH COUNTY

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO OVER THE STRAIGHT RIVER DISTRICT 6 - RICE COUNTY

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO CSAH NO. 101 OVER THE MINNESOTA RIVER DISTRICT 8 - REDWOOD COUNTY

UNDERWATER BRIDGE INSPECTION REPORT DISTRICT 8 - LAC QUI PARLE COUNTY

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO MSAS 123 (2 ND AVE. SW) OVER THE CANNON RIVER CITY OF FARIBAULT, RICE COUNTY

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO CSAH NO. 7 OVER THE SNAKE RIVER DISTRICT 1 - PINE COUNTY

UNDERWATER BRIDGE INSPECTION REPORT DISTRICT 8 - LAC QUI PARLE COUNTY

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO CSAH 4 OVER THE BEAVER RIVER ST. LOUIS COUNTY

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO CSAH 133 OVER A DITCH ST. LOUIS COUNTY

UNDERWATER BRIDGE INSPECTION REPORT DISTRICT 4 - OTTER TAIL COUNTY

UNDERWATER BRIDGE INSPECTION REPORT DISTRICT 4 - OTTER TAIL COUNTY

UNDERWATER INSPECTION REPORT DOUBLE CORRUGATED METAL PIPE CULVERT HAWTHORN ROAD OVER RICE CREEK (PELKEY LAKE) MORRISON COUNTY

2016 UNDERWATER BRIDGE INSPECTION REPORT. 81(ENCHANTED LANE) over CHANNEL. Date of Inspection: Equipment Used: 09/07/2016

2016 UNDERWATER BRIDGE INSPECTION REPORT. CSAH 10 over POMME DE TERRE RIVER. Date of Inspection: Equipment Used: 06/18/2016. County Highway Agency

2016 UNDERWATER BRIDGE INSPECTION REPORT. CR 52 over CALDWELL BROOK. Date of Inspection: Equipment Used: 06/04/2016. County Highway Agency

Underwater Inspection of Bridges Overview of a Statewide Program

2016 UNDERWATER BRIDGE INSPECTION REPORT. CSAH 14 over BUTLER CREEK. Date of Inspection: Equipment Used: 06/21/2016. County Highway Agency

PED (OLD TWNS RD) over OTTER TAIL RIVER

State DOT - Bridge Inspection Manual Part II Course No. SE0117 PDH: 10

Bridge Failures in Alberta

Annex E Bridge Pier Protection Plan

Information for File # SEW

Components of a Barrage

Summary of HEC 18, Evaluating Scour at Bridges FHWA NHI Should really follow HEC 18, but this summary will get you the main points.

STRUCTURAL STABILITY ASSESSMENT

(Revised February,2005) CULVERTS, BRIDGES, AND FORDS

High Definition Laser Scanning (HDS) Underwater Acoustic Imaging and Profiling

Culvert Safety Inspection Report

Earthen Embankments. turning into larger, more costly repairs. The following. The State Dam Safety Program has inspection

FLAGLER BEACH PIER POST INCIDENT SAFETY INSPECTION HURRICANE IRMA SEPTEMBER 15-17, 2017

As temporary grade control facilities along waterways until final stabilization is established.

INFILTRATION PRACTICE MAINTENANCE INSPECTION FORM

PROPOSING A NEW PORTABLE DEVICE FOR BRIDGE SCOUR INSPECTION

The Challenge of Wave Scouring Design for the Confederation Bridge

Lateral Load Analysis Considering Soil-Structure Interaction. ANDREW DAUMUELLER, PE, Ph.D.

Existing conditions of each bridge and repair plan are presented in Table

ANNUAL INSPECTION BY A QUALIFIED PROFESSIONAL ENGINEER ALL CCR IMPOUNDMENTS CCR Rule Section (b)

Illinois State Water Survey

Smoothing Out the Bumpy Road Ahead

Bridge Design Preliminary Bridge Design Example 1 / 6 Spring 2012 updated 1/27/2012

Storm Damage Floating Culverts & Other Inlet Issues

CONDITION ASSESSMENT REPORT

CE 535, Spring 2002 Preliminary Design Example 1 / 6

Cranes Roost Park Facility Analysis

Gerald P. Oliveto, P.E. George Franz NJDOT

ANNUAL INSPECTION BY A QUALIFIED PROFESSIONAL ENGINEER ALL CCR IMPOUNDMENTS CCR Rule Section (b)

Culvert Design for Low and High Gradient Streams in the Midwest. Dale Higgins, Hydrologist Chequamegon-Nicolet National Forest

HY-8 Version 7.2 Build Date January 17, Federal Highway Administration.

CHAPTER 5 CULVERT DESIGN

APPENDIX A STRUCTURE DESCRIPTIONS AND RATING CURVES

We re good at what we do! Anywhere, TX SITE

Guidelines for Underwater Inspection and Imaging of Railroad Bridges

Bridge Inspection Access to Minimize Operational Impacts

PENNDRAIN.rep. HEC-RAS Version May 2005 U.S. Army Corp of Engineers Hydrologic Engineering Center 609 Second Street Davis, California

RULES PUBLICATION NO. 52/P UNDERWATER INSPECTION OF MOBILE OFFSHORE DRILLING UNITS IN LIEU OF DRYDOCKING

JAP Additional Information Sheet

EPA R6 Dive Team Operations Report. San Jacinto Waste Pits Channelview, TX December 9-10, 2015

RLRC COMMUNITIES EAST GRAND FORKS AREA CHARACTER THE RED LAKE RIVER & THE RED RIVER OF THE NORTH CONFLUENCE EAGLE POINT BOAT LAUNCH DESIGN

REVISIONS TO THE NATIONAL BRIDGE INSPECTION STANDARDS (NBIS)

Underwater repair for bridge

Great Lakes Stream Crossing Inventory Instructions

TYPES OF FOUNDATION. Superstructure. Substructure. Foundation

Item 404 Driving Piling

OFFICE OF STRUCTURES MANUAL FOR HYDROLOGIC AND HYDRAULIC DESIGN CHAPTER 11 APPENDIX B TIDEROUT 2 USERS MANUAL

TCML operate and control the 146 Km Railway line from Lake Magadi to Konza.

COASTAL HAZARDS. What are Coastal Hazards?

Bids DECEMBER 21, 2018 AT 2:00 P.M. (EASTERN) (Estimated Cost: $4,700,000.00)

3. Types of foundation

Structure Failure Modes

Chadbourne Dam Repair and Fish Barrier

Nome Harbor Page 2 of 12

The Dalles Dam Powerhouse Trash Rack ROV Inspection Report

Rock Ramp Design Guidelines. David Mooney MS Chris Holmquist-Johnson MS Drew Baird Ph.D. P.E. Kent Collins P.E.

APPENDIX C VEGETATED EMERGENCY SPILLWAY. VERSION 1.0 March 1, 2011

Training and Evaluation Outline Report

2018 Beach Preservation Project Information

TDLP INC. The Dam & Levee Professionals. Kevin Chancey Sarah Edens. Monica Murie Jason Unruh

Perched Box Caisson Overview. January 2014

Green CCR Surface Impoundment

MIRABAY PILOT PROJECT REPORT

APPENDIX C ESTIMATING SCOUR IN BOTTOMLESS ARCH CULVERTS

ITEM 400 STRUCTURAL EXCAVATION AND BACKFILL

Technical Report Culvert A Hydraulic Analysis

Bids MAY 24, 2018 AT 2:00 P.M. (EASTERN) (Estimated Cost: $7,500,000.00)

CLEANING, INSPECTION, AND TESTING OF SEWERS

Use of Underwater Dry Welding for In Situ Repair to Offshore Structures. Sabine Powell 02/12/2016

TECHNICAL MEMORANDUM 002 EMORANNO. 001

Whitewater Valley Station Surface Impoundment Coal Combustion Residual Annual Report

Recovery, Reuse, and Recycling of Debris From the Demolition of the Grace and Pearman Bridges at Charleston, South Carolina

REVETMENTS. Purposes and Operational Constraints. Purposes Erosion control o o. Revetment Design 4/5/2016. CE A676 Coastal Engineering

Bridge Design for Marine Vessel Collision

Session 1. Pushover Analysis of a Torsionally Eccentric Cellular Abutment. Date 11/03/ PM 4 PM Eastern Time

Outlet Structures T-12

APPENDIX K CULVERT INSPECTION MEMO

1-32 NOME HARBOR, ALASKA (CWIS NOS , 87755, 12270, & 10422) Condition of Improvement 30 September 2012

Lecture 10 : Sewer Appurtenances

Access Management Standards

RISK RATING SAFE WORK METHOD STATEMENT 1 HIGH 2 MEDIUM 3LOW. I approve the use of this Safe Work Method Statement: NAME: POSITION: Department Manager

Transcription:

UNDERWATER BRIDGE INSPECTION REPORT STRUCTURE NO. 62555B WABASHA STREET SOUTH BOUND (MASA 235 SB) OVER THE MISSISSIPPI RIVER CITY OF ST. PAUL OCTOBER 31, 2012 PREPARED FOR THE MINNESOTA DEPARTMENT OF TRANSPORTATION BY COLLINS ENGINEERS, INC. JOB NO. 7423

MINNESOTA DEPARTMENT OF TRANSPORTATION UNDERWATER BRIDGE INSPECTION REPORT SUMMARY: The concrete substructure unit inspected at Bridge No. 62555B, Pier 3, was found to be in good condition with no defects of structural significance observed. The concrete of the pier column was smooth and sound. The channel bottom appeared stable at the time of the inspection with no significant scour. INSPECTION FINDINGS: (A) The concrete was in good and sound condition with no structurally significant defects observed. (B) The channel bottom material consisted of riprap up to 1 foot in diameter at the upstream nose of the pier. (C) The channel bottom material downstream of the pier consisted of sandy infilling allowing up to 1 foot of probe rod penetration. (D) The embankments were well armored with 1 foot diameter riprap.

RECOMMENDATIONS: (A) Reinspect the submerged substructure units at the normal maximum recommended (NBIS) interval of sixty (60) months.

MINNESOTA DEPARTMENT OF TRANSPORTATION UNDERWATER BRIDGE INSPECTION 1. BRIDGE DATA Bridge Number: 62555B Feature Crossed: Mississippi River Feature Carried: Wabasha Street South Bound Location: City of St. Paul Bridge Description: The bridge superstructure consists of a four span bridge constructed of concrete segmental box girders. The superstructure is supported by two concrete abutments and three concrete piers. The piers are numbered 1 to 3 starting from the north end of the bridge. 2. INSPECTION DATA Professional Engineer/Team Leader: Barritt R. Lovelace, P.E. (WSB) Dive Team: Lukas Janulis, P.E., Brad Robinson (WSB) Date: October 31, 2012 Weather Conditions: Sunny, 40 F Underwater Visibility: 1.0 feet Waterway Velocity: Negligible/None

3. SUBSTRUCTURE INSPECTION DATA Substructure Inspected: Pier 3. General Shape: The pier consists of a rectangular concrete column on rectangular footings supported by steel H-piles. Maximum Water Depth at Substructure Inspected: Approximately 13.8 feet. 4. WATERLINE DATUM Water Level Reference: The top of the pier stem at the downstream end of Pier 3 at Structure No. 62555A. Water Surface: The waterline was approximately 15.4 feet below reference. USGS M.S.L. Waterline Elevation = 684.8 5. NBIS CODING INFORMATION (Minnesota specific codes are used for 92B and 113) Item 60: Substructure: Code 7 Item 61: Channel and Channel Protection: Code 7 Item 92B: Underwater Inspection: Code B/10/12 Item 113: Scour Critical Bridges: Code N/02 Bridge is scour critical because abutment or pier foundation is rated as unstable due to observed scour at bridge site. Yes X No

6. STRUCTURAL ELEMENT CONDITION RATING Item # Element Description Quantity Unit Conditions 1 2 3 4 5 205 Reinforced Concrete Column 1 EA 1 985 Slopes and Slope Protection 1 EA 1

Photograph 1. View of Pier 3, Looking Southwest. Photograph 2. Overall View of the Structure, Looking West.

MINNESOTA DEPARTMENT OF TRANSPORTATION OFFICE OF BRIDGES AND STRUCTURES DAILY DIVING REPORT INSPECTORS: Collins Engineers, Inc. DATE: October 31, 2012 ON-SITE TEAM LEADER: Barritt R. Lovelace, P.E. (WSB) BRIDGE NO: 62555B WEATHER: Sunny, 40 F WATERWAY CROSSED: Mississippi River DIVING OPERATION: X SCUBA SURFACE SUPPLIED AIR OTHER PERSONNEL: Lukas Janulis, P.E., Brad Robinson (WSB) EQUIPMENT: Commercial Scuba, Probe Rod, Lead Line, Sounding Pole, U/W Light, Scraper, Camera, 14 Boat. TIME IN WATER: 9:40 A.M. TIME OUT OF WATER: 9:50 A.M. WATERWAY DATA: VELOCITY Negligible/None VISIBILITY 1.0 feet DEPTH 13.8 feet maximum ELEMENTS INSPECTED: Pier 3 REMARKS: Overall, Pier 3 was found to be in good condition with no defects of structural significance observed. The concrete of the pier column was smooth and sound. The channel bottom appeared stable at the time of the inspection with no significant scour. FURTHER ACTION NEEDED: YES X NO Reinspect the submerged substructure units at the normal maximum recommended (NBIS) interval of sixty (60) months.

MINNESOTA DEPARTMENT OF TRANSPORTATION OFFICE OF BRIDGES AND STRUCTURES UNDERWATER INSPECTION CONDITION RATING FORM BRIDGE NO. 62555B INSPECTION DATE October 31, 2012 INSPECTORS Collins Engineers, Inc. NOTE: USE ALL APPLICABLE CONDITION ON-SITE TEAM LEADER Barritt Lovelace, P.E. (WSB) DEFINITIONS AS DEFINED IN THE MINNESOTA WATERWAY CROSSED Mississippi River RECORDING AND CODING GUIDE INCLUDING GENERAL, SUBSTRUCTURE, CHANNEL AND PROTECTION, AND CULVERTS AND WALL DEFINITIONS TO COMPLETE THIS FORM. CONDITION RATING SUBSTRUCTURE CHANNEL GENERAL UNIT REFERENCE NO. MAXIMUM DEPTH OF WATER PILING COLUMNS, SHAFTS, OR FACES* FOOTINGS DISPLACEMENT OTHER OVERALL SUBSTRUCTURE CONDITION CODE* SCOUR EMBANKMENT EROSION EMBANKMENT PROTECTION OTHER (DRIFT/DEBRIS) OVERALL CHANNEL & PROTECTION CONDITION CONCRETE STEEL TIMBER LOSS OF SECTION PREVIOUS REPAIR OR MAINTENANCE OTHER UNIT DESCRIPTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Pier 3 13.8 N 7 N N N 7 N 8 8 N 7 7 N N N N N *UNDERWATER PORTION ONLY REMARKS: Overall, Pier 3 was found to be in good condition with no defects of structural significance observed. The concrete of the pier column was smooth and sound. The channel bottom appeared stable at the time of the inspection with no significant scour. NOTES: ATTACH SKETCHES AS NEEDED, IDENTIFY REMARK BY REFERRING TO UNIT REFERENCE NO. AND REMARK NO. USE GENERAL SECTION TO IDENTIFY OVERALL PRESENCE OF SPALLS, CRACKS, CORROSION, ETC.