Fine Pore Aeration Systems Testing Michael K. Stenstrom Professor, Civil and Environmental Engineering Department

Similar documents
Technical Bulletin 160. Maximum Air Pressure for Diffusers. by:

OXYGEN TRANSFER CAPABILITIES CANADIANPOND.CA PRODUCTS LTD.

FINE BUBBLE DISC DIFFUSER

IMPROVING PLANT AERATION USING GAS INFUSION TECHNOLOGY

aeration and mixing systems

The activated sludge process

Supratec. MEMBRANE-PLATE-DIFFUSER For fine bubble aeration of liquids BELÜFTUNGSTECHNIK UMWELT- & VERFAHRENSTECHNIK SERVICE & WARTUNG

PROCESS AND AERATION OPTIMISATION USING ONLINE OFFGAS ANALYSIS

Sewage aeration systems

Oxygen mass transfer in a bubble column with non-newtonian fluids

Technical Bulletin 148. Comparison of Flat Panel to MiniPanel. by:

Supratec von-drais-straße 7 D Simmern/Hunsrück Fon: *49 ( ) Fax: *49 ( )

AERATION & MIXING SYSTEMS

A TYPICAL AERATION UPGRADE CONSIDERATIONS AND OUTCOMES. Michael Young. Michael Young, Director, Faraga Pty Ltd and Aer-Force Pty Ltd

Disc diffuser ELASTOX -T

Red Valve Coarse and Fine Bubble Air Diffuser Systems

Supratec Gesellschaft für Umweltund Verfahrenstechnik mbh OXYFLEX - M T / M T M E M B R A N E D I S C D I F F U S ER AERATION TECHNOLOGY

Supratec AERATION TECHNOLOGY. von-drais-straße 7 D Simmern / Hunsrück. tel.: / fax: /

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

DEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111

Freeze-Thaw Effects and Gas Permeability of Utility Line Backfill

Panel diffuser ELASTOX -P

Solubility of the gases

Generating Calibration Gas Standards

Novelty of Mechanical Surface Aerator Using Flexible Beam to Generate Dissolved Oxygen in Water

AquaDDM. Direct-Drive Mixer. Often Imitated Never Duplicated

Technical Bulletin 161. How Deep Can I Design my Aeration Tanks? by:

Method of Test for Sieve Analysis

(a) (i) Describe how a large difference in oxygen concentration is maintained between a fish gill and the surrounding water.

CTB3365x Introduction to Water Treatment

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

Operating Guidelines for PermSelect Modules Liquid Contacting

Pressure Measurement

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

ECD High Pressure Ceramic Micro Bubble Diffuser - User Instruction Manual

Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

Tank Blanketing Pressure Regulators RHPS Series

Gas Physics Pressure and Flow Topics Covered:

Mass Split of Two-Phase-Flow

Power Transformer Maintenance. Maintenance Practices & Procedures for Substation Class Distribution Power Transformers

Brent Sleep, Magdalena Krol, University of Toronto Kevin Mumford, Queen s University Richard Johnson, Oregon Health and Science University

Supratec. von-drais-straße 7 D Simmern/Hunsrück Fon: +49 ( 67 61) Fax: +49 ( 67 61)

Oxygen Measurement Systems High Reliability and Wide Application Coverage

OPTIMA 7 - BIOGAS Calibrating the gas sensors SENSOR ADJUSTMENT. Diamond Scientific 625 Peachtree St., Cocoa, Florida /Tel:

The Helium Leak Detector

Instruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.

Oxymax COS61/COS61D. Technical Information

Physics 7b Midterm Exam #1 Fall Name: Disc. Section SID

Instrumentation & Data Acquisition Systems

Analysis of Shear Lag in Steel Angle Connectors

Oxygen Sensor with Electrode

INSPECTION REPORT ON 450? KLD STP SOBHA CHRYSANTHEMUM APARTMENTS THANISANDRA MAIN ROAD

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Squire-Cogswell

UTILIZATION OF LEAKY PIPES AS AERATION SYSTEM FOR AQUACULTURE

ENVE 301 Environmental Engineering Unit Operations

Grit chambers are basin to remove the inorganic particles to prevent damage to the pumps, and to prevent their accumulation in sludge digestors.

ROTAMAT Rotary Drum Fine Screen Ro 2 / RPPS

Process Simulator Evaluates Blower and Valve Control Strategies for WWTP Aeration

RESISTANCE OF COMPACTED ASPHALT MIXTURE TO MOISTURE INDUCED DAMAGE (Kansas Test Method KT-56)

HUBER Rotary Drum Fine Screen ROTAMAT Ro2 / RPPS / STAR

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

with O 2 Controller Instruction Manual

CTB3365x Introduction to Water Treatment

The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure

product manual H-2795 Roll-a-Meter

TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

The Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.

Wastewater combination air valve in stainless steel AISI 316 Mod. SCS

Rev. 1. Cryogenics Thermoflasks. 2122, 2123, 2124, 2129, and 2130

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

ASPHALT PLANT LEVEL 1

LNG Cargo Operations. Juan Manuel Martín Ordax

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

The Effects of Stir Speed, Airflow Rate, Diffusers, and Volume on. Water Aeration

VACUUM TESTING PRECAST CONCRETE MANHOLES

6. Positioning. 6.1 General description

Impact of imperfect sealing on the flow measurement of natural gas by orifice plates

maintaining storage tank dissolved oxygen levels utilizing gas transfer membranes

DAV - WP DAV - WP. Wastewater Air Valves. Product Catalogue. (Wastewater Air Valves) DAV - WP

Kinetic-Molecular Theory

SPIROVENT VACUUM DEGASSERS

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Density of Granular Material by Modified Sand-Cone Method for Thin Layers

Mass Spec will not Autotune

MiniMag. 1 of 8. The MiniMag scrubber s 2 recover drain are 80% larger than a 1.5, making the MiniMag scrubber s drain hose less likely to clog.

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

TDLP INC. The Dam & Levee Professionals. Kevin Chancey Sarah Edens. Monica Murie Jason Unruh

Gas Conversion Kits CERAMIC HEATER SERIES (1, 2, 3, 4 Burner Units)

INSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!

Energy and mass transfer in gas-liquid reactors.

Light Commercial Reverse Osmosis System. EE-1000 Manual

CHEMISTRY - CLUTCH CH.5 - GASES.

Phys101 Lectures Fluids I. Key points: Pressure and Pascal s Principle Buoyancy and Archimedes Principle. Ref: 10-1,2,3,4,5,6,7.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Please note that there was an error in the initial proposal: samples should be nominally 1 inch in diameter (see below).

PRE LABORATORY ASSIGNMENT: Lab Section Score: /10 READ THE LAB TEXT BEFORE ATTEMPTING THESE PROBLEMS!

Appendix A. Imbrium Systems Jellyfish Filter Inspection and Maintenance Information

Transcription:

Fine Pore Aeration Systems Testing Michael K. Stenstrom Professor, Civil and Environmental Engineering Department

Fine Pore Diffusers Fine pore aeration systems are the most energy conserving alternative we have for the activated sludge process, and may other applications Well established technology and design principles Nevertheless, we have had many technology failures Proper utilization of the technology requires a commitment to maintenance

Outline Terminology Off-gas testing Materials testing Some conclusions

Terminology Efficiency Standard oxygen transfer efficiency (SOTE) (percent oxygen transferred) Standard oxygen transfer rate (SOTR) (mass transferred per unit time) Standard aeration efficiency (SAE) (mass transferred per unit time per unit power)

Terminology Cont. SOTE - percent SOTR lb O2/hr or kg O2/hr SAE lb O2/hp-hr or kg O2/kW-hr All above at standard conditions (e.g. 20 o C, clean water, etc.) OTE, OTR, AE at process conditions

Standard and Process Conditions Correction formulas based upon driving force, temperature, barometric pressure, water quality, saturation concentration, etc Driving force and water quality the most significant Driving force = (DO S DO)/DO S Water quality alpha factor, 0 to 1 Total correction can result in process water transfer of only 30 to 80% of clean water transfer

Off-Gas Testing Accepted as the best way to do process water testing of diffused aeration systems Used to the exclusion of almost all other methods for diffused systems Provides reliable indication of aeration efficiency, air flow distribution, wastewater flow splits among parallel aeration tanks, diffuser aging Reliable in underloaded, critically loaded and overloaded treatment plants

Analyzer Off-Gas Technique Hood to capture off-gas Air

OTE = = = The Mathematics mass O2 in mass O2 out mass O2 in G i ( M o / M i ) MR o / i - G i ( M o / M i ) MR og / i G i MR o / i MR og / i MR o / i ( M o / M i ) MR o / i Use the ratio of oxygen to inerts to remove gas flow rate from the calculation

Off-Gas Measurement Use a simple fuel cell to measure oxygen partial pressure Ambient air for calibration of mole ratio Remove moisture and CO 2 to simplify the procedure Measure off-gas and compare to ambient air

Measuring Air Flow Rate Not needed for OTE measurement Useful to create an average of a large basin Needed to calculate the oxygen uptake rate, or total mass transferred Measure discharge from hood by establishing a stable pressure under the hood

Off-Gas Analyzer Rotometer Manometers Fuel Cell Vacuum Cleaner

Off-Gas Hood Copy right 2000-2007 Michael K. Stenstrom

Analyzer in Action Copy right 2000-2007 Michael K. Stenstrom

Small Hoods Copy right 2000-2007 Michael K. Stenstrom

Large Hoods Copy right 2000-2007 Michael K. Stenstrom

Really Large Hoods Copy right 2000-2007 Michael K. Stenstrom

Coarse Bubble Hoods Sand Bags Testing in a turbulent spiral roll system requires a heavy hood and weights

Off-Gas Results Define aeration capacity Track aerator performance and health Better understand process conditions Define key process parameters for expansion Warranty Opportunities

Typical Results 24 Tank dewatered, diffusers brushed and hosed 22 Alpha SOTE 20 18 16 0 0.5 1 1.5 2 2.5 3 3.5 Date (Years)

A Tale of Two Tanks 20 18 16 High SRT (Nitrifying) asote (%) 14 12 10 8 6 Low SRT (Non-Nitrifying) 0 200 400 600 800 1000 Distance (feet)

Transfer Efficiency and Pressure Drop In a small tank, one can test pressure drop, oxygen transfer efficiency and observe flow patterns PI Air

Materials Testing in the Lab Copy right 2000-2007 Michael K. Stenstrom

Special Holders for Membranes

120 Decrease in Pressure Drop With Acid Cleaning Pressure Drop (inches water column) 100 80 60 40 20 0 Pressure Drop First HAC Addition Second HAC Addition Third HAC Addition 0 5 10 15 20 25 30 Time (minutes)

Field Pressure Drop Device

Typical Results Pressure Drop 0.14 Diffusers Cleaned Pressure Drop (Bar)) 0.12 0.1 0.08 0.06 0 0.5 1 1.5 2 Elapsed Tim e (Years)

Poor Flow Distribution

Evaluating Membrane Hardness and Strength

Durometer Pin penetrates surface as a function of hardness

Small Test Frame Force Membrane Dog Bone Displacement

Load Cell on Test Frame Load Cell

Thickness Pressure gage for repeatable measurements

Measuring Orifice Diameters Pin inserts into an orifice a fixed distance as a function of its diameter

Change in Modulus weakening with age 1.35 1.3 1.25 1.2 1.15 New New Old Old 1.1 1.05 1 N1 N2 O1 O2 Membrane Number

Microscopic Examination (Polyurethane Membrane)

Microscopic Examination (Sintered Plastic)

Microscopic Examination (EPDM Membrane) Used New

Silicone Membranes Membrane Surface Pore Close Up Pore Side View From Wiehe and Libra (2004)

Conclusions It is easy to track fine pore aeration system performance with off-gas testing One or two days every few months gives a health report of the aeration system. Initial and periodic testing give good information for design Lab-scale testing for material properties and sources of fouling can predict failures or help you understand why membranes failed A small, but routine investment in testing is needed Must plan cannot just decide to go out and test. Diffusers must be observed over time to detect changes in efficiency or properties