LPU- 40 Flotation Collar

Similar documents
CBP LPU- 40 Flotation Collar User s Manual

ALPS Flotation Collar. User s Manual

SURVIVOR SERIES AIRCREW FLOTATION VEST PACKING INSTRUCTIONS

Personal Flotation Collar (PFC-1)

Owner s Manual. MD3196 and MD3091 Compact Tactical Life Preservers. *Shown with the MA3090 Chest Belt/Crotch Strap Assembly

SMA1060 INSTRUCTIONS FOR SELF INSPECTION SMA1061 MANUAL INFLATION SMA1062 AUTO INFLATION

Tactical Flotation Support System (TFSS) User s Manual

SMA1500 Instructions for Self Inspection SMA MANUAL INFLATION SMA AUTO INFLATION

Rapid Survival System

CREWFIT 165 SPORT. self care and maintenance manual

Pay special attention to information provided in warnings, cautions and notes that are accompanied by one of these symbols:

SMA2100 Series CONSTANT WEAR LIFE PRESERVER VEST (CWLP) SMA2160 OWNERS MANUAL

CBP Air Crewman Survival Vest

MD1250 TACTICAL INFLATABLE SIDE POUCH LP

DO NOT REMOVE PRIOR TO SALE MD1250

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK.

NATIONAL (NATO) STOCK NUMBER: NSN

Service Manual. Mullion Hi-Rise 275N SOLAS dot twin chamber lifejacket with Hammar hydrostatic mechanism.

THIS CARD IS MAINTAINED TO PROVIDE PROCEDURAL TEXT ONLY AND IS NOT REPORTED TO ACMS

SURFACE SUPPLIED HARNESS

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL for Model No. 1212

AUXILIARY ACR PLB Monthly Inspection and Test For use by Auxiliary members issued ACR PLBs within District Eleven North Revised Jan 2016

Falcon 3 145, 170, 195 and Tandem Owner / Service Manual

ANNUAL SELF INSPECTION / SERVICING INSTRUCTION SHEET

SMA1060 OWNERS MANUAL

LTS BCD USER GUIDE. Hollis (2014) Doc r01 (8/29/14)

Butler Tactical Parachute Systems, LLC

INSTRUCTION MANUAL. Featuring - Quick Burst Zipper Survival Operations Specialist SOLAS (74/96) Approved Lifejacket

Owner's Manual SMA2000 Series

600 / 600FC OWNER'S MANUAL

solo harness USER GUIDE

OWNERS MANUAL FOR MODEL TD2401 Inflatable Throwable Device (Type IV PFD).

Inflatable Dock Slide Owner s Manual

Fit Testing. C50 APR New Equipment Training Module March 2010 Rev01

DO NOT REMOVE PRIOR TO SALE! OWNER S MANUAL for Model 33M42-V17

INFLATABLE PFD S INSTRUCTIONS FOR ANNUAL SERVICE AND SELF INSPECTION

Assembly Instructions. for. Puffin Saranac. ScanSport, Inc. P.O. Box 700 (234 May Street) Enfield, New Hampshire Phone: (603)

ANNUAL SELF INSPECTION AND SERVICE INSTRUCTIONS

Pontoon Slide Owner s Manual

Sea Rebel Kayak Owner s Manual

NORTHERN DIVER PFD MANUAL

MD5183 ELITE INFLATABLE PFD

MAINTENANCE PROCEDURE FOR X 650

Owner s Manual RESCUE STICK TM MRD100 THROWABLE EMERGENCY RESCUE INFLATABLE

Owner s Manual. MD Inflatable Vest with LIFT TM Hydrostatic Inflation Model - Manual with Automatic Backup

ExtendAire TM II. Intermediate Pressure Accessory Kit USER INSTRUCTIONS

Combination Breathing Apparatus

Storm Owner s Manual

IMMERSION SUIT MAINTENANCE GUIDE IMMERSION SUIT MAINTENANCE GUIDE 1409 SERIES. SCMG003A Maintenance Guide - Immersion Suits USA ENGLISH.

Hammar LifeJacket Inflator

Inflatable Stand Up Paddle Board Manual

inflatables pfd s ANNUAL SELF INSPECTION AND SERVICE INSTRUCTIONS

COMFORT MAXTM BELT PACK

DO NOT REMOVE PRIOR TO SALE! Model Nos or 6340 OWNER S MANUAL HIGH WEARABILITY TYPE V USER ASSISTED INFLATABLE BELT PERSONAL FLOTATION DEVICE

INFLATABLE PFDs. MD2010 Manual Inflation Model. MD2012 Manual with Automatic Backup Inflation Model

Instant Garage 20' x 12' 3" x 8' 3"

On the Go Swing System Instruction Manual

Inflatable PFD Owner s Manual

Pontoon Slide Owner s Manual

Pontoon Slide Owner s Manual

CO2 Tank Conversion Kit P.N , P.N , and P.N

SAFETY BELTS. Size (height): M(64-69") L(68-73") XL(72-78") XX(74-80"). Color: Black harness with international orange vest.


WE SAVE LIVES FOR A LIVING

3M Liqui-Cel EXF-10x28 Series Membrane Contactor

On the Go Swing System Instruction Manual

CPR Coastal Passage Raft

AirForce Owner s Manual MD3031 Manual with Automatic Backup Inflation Model

Pressure Dump Valve Service Kit for Series 2300 Units

Aqua Attachments Owner s Manual

Owner s Manual. MD3085 Inflatable PFD Manual Inflation Model Recreational: USCG Approved Type III Uninspected Commercial Vessels: USCG Approved Type V

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

User s Manual. Model SWTC800. CAUTION: Adult Assembly Required

FOR MODEL NUMBERS MD2981 (MANUAL) / MD2983 (AUTO) OWNER'S MANUAL DLX 38 INFLATABLE PFD

Trampoline Installation Instructions

SERVICE INSTRUCTIONS

Dual Electronic Basketball System Owners Manual

Maintenance and Repair. AirHawk II Air Mask. Second Stage Regulator. Order No.: /02 Prnt. Spec (I) MSAsafety.

Pressure Dump Valve Service Kit for Series 3000 Units

602 STRINGING MACHINE OWNER'S MANUAL

Trampoline & Enclosure Assembly Instructions

Inflatable Stretcher. Product Manual

User Guide. Tripod. flowtech 75 / 100 Tripod. Part No. S S

VERSA BIKE RACK INSTRUCTIONS

Owner s Manual. MD3184 Inflatable PFD Hydrostatic Inflation Model - Manual with Automatic Backup with Harness Recreational: USCG Approved Type V

MD3183 / Hydrostatic Inflation Model / Manual with Automatic Backup USCG Approvals: Recreational: Type II Uninspected Commercial Vessels: Type V

Product Information News September 26, 2003

7130 Lancer Rear Drive Magnetic Commercial Indoor Cycling Bike

FIRST TEAM SPORTS, INC Storm Portable Series Assembly Instructions

3. Align ratchet drive with female insert on assembly, and raise ratchet handle until the ratchet drive is firmly seated into the assembly.

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

CHAPTER 5 REWIND STARTERS

MD2014 INFLATABLE PFD Manual Inflation Model USCG APPROVALS: RECREATIONAL: TYPE III UNINSPECTED COMMERCIAL VESSELS: TYPE V

The Service label can be found

OWNER S MANUAL AirTop Large and AirTop Small

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Palau and Hibiscus Inflatable SUP Board Owner s Manual

Inflatable Personal Flotation Device (PFD) OWNER S MANUAL

BABY ROCKER WITH TOY BAR

Transcription:

105 Nutmeg Road South South Windsor, CT 06074 sales@capewell.com P: 860.610.0700 www.capewell.com LPU- 40 Flotation Collar User s Manual

List of Revisions or Amendments Date Revision or Amendment 12 January 2010 Addition of annual and funtional inspection procedures 29 March 2011 Correction of CO2 bottle size 26 March 2012 Correction to Green Plastic Safety Clip PN 26 March 2012 Address/Logo change 19 April 2013 PN s updated, page 27

Table of Contents 1. Introduction 4 2. Attaching the Collar to the Vest 5 3. Inflating the Bladder 8 4. Inspection 12 5. Maintenance 12 6. Storage 12 7. LPU-40 Flotation Collar Repack Instructions 13 8. Annual Inspection 20 9. Functional Inspection 21 Appendix A. LPU-40 Flotation Bladder Nomenclature 22 Appendix B. LPU-40 Casing Nomenclature 23 Appendix C. Bladder Evacuation Attachment Nomenclature 24 Appendix D. LPU-40 Bladder Folding Diagram 25 Appendix E. LPU-40 Folding Cinch Strap Diagram 26 Appendix F. LPU-40 Spare Parts List 27 Copyright Notice This owner s manual is copyrighted, all rights reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any electronic medium or machine readable form without prior consent in writing from Capewell Aerial Systems LLC Copyright 2015 Page 3

The following symbols are used throughout this manual: Warnings indicate a procedure or situation that may result in serious injury or death if instructions are not followed correctly. Ca u t i o n s indicate any situation or technique that will result in potential damage to the product, or render the product unsafe if instructions are not followed correctly. Notes are used to emphasize important points, tips, and reminders. 1. Introduction The LPU-40 Flotation Collar is a flotation device designed to support air crewmen stranded in water. The collar is attached to the air crewman s flight vest. It provides a minimum of 65 pounds of flotation buoyancy and is designed to keep the user s head above the water for an extended period of time. The LPU-40 is packed in a low profile casing made of fire resistant Nomex that is designed to open when the dual-chambered bladder inflates. A single-pull beaded handle, when manually pulled, activates two 29-gram CO2 gas cartridges for inflation. Two oral inflation tubes allow the user to manually increase, decrease, or maintain the air pressure in the bladder chambers. The capacity of the CO2 cartridges can range from 28 to 31 grams. Your LPU-40 Flotation Collar is an important piece of survival equipment. Proper care and maintenance will ensure your vest will accomplish the level of safety performance it is designed for. It is important that you become familiar with these instructions to safely use this flotation collar. WARNING k e e p y o u r f l o t a t i o n collar in u s a b l e c o n d i t i o n. Im p r o p e r w e a r m a y r e s u l t in d a m a g e t o t h e collar. d o n o t w e a r a n y g a r m e n t o r p i e c e o f e q u i p m e n t o v e r t h e collar. i m p r o p e r u s e o r n e g l i g e n t c a r e o f t h i s e q u i p m e n t c a n c a u s e s e r i o u s i n j u r y o r d e a t h. Page 4

2. Attaching the Collar to the Vest Top 2.1 The collar attaches to the vest with a MOLLE Strap system and has four attachment straps: two on the top of the collar, and two on the bottom. Bottom 2.1 Attachment points. Back 2.2 The attachment points for the top of the collar are on the back of the vest. The attachment points for the bottom of the collar are on the front of the vest at chest level. Front 2.2 Attachment points. Page 5

2.3 Attach the top of the collar to the vest first. Thread the MOLLE straps on the collar through the channeled webbing on the vest and secure the Pull-the-Dot fasteners. Each strap has two Pull-the-Dot fasteners. Ensure that all four Pull-the-Dot fasteners are fastened. 2.3 Attaching the top. 2.4 The bottom attachment is threaded through four webbing straps on each side of the vest. On each side of the vest, weave the MOLLE strap through the first two channels on the vest and collar. 2.4 Attaching the bottom. Page 6

2.5 Thread both the collar strap and the closing tab with the snap stud through the third channel on the vest, then through the last channel on the collar. 2.5 Threading the bottom channels. 2.6 Thread only the collar strap through the last vest channel. Wrap the strap around the vest channel and secure the Pull-the-Dot fastener. Tuck the end of the closing tab underneath the collar casing. 2.6 Closing the snap. Page 7

3. Inflating the Bladder 3.1 Grab the beaded handle with either hand and forcefully pull down to release it from the cover flap. 3.1 Grabbing the beaded handle. 3.2 Continue to pull the handle forcefully in the down-and-out direction; apply constant pressure on the handle until the bladders begin to inflate. Repeat this step if the bladder does not begin to inflate or if only one lobe inflates. 3.2 Activating the CO 2 gas. Page 8

3.3 The two lobes may be attached and anchored to your vest using the cinch ring located on the left-inside-bottom area of the vest. Anchoring the lobes to the vest improves the angle of flotation. CAUTION Release the cinch ring prior to over-water missions. WARNING if y o u m u s t d r o p t h e c i n c h r i n g w h i l e y o u a r e s u b m e r g e d in w a t e r, d o n o t u n z i p y o u r v e s t t o d o s o. 3.3 Exposing the cinch ring. d r o p t h e c i n c h r i n g b y r e a c h i n g u n d e r y o u r v e s t w h i l e it is fully donned with the slide fastener up. 3.4 The right lobe has a cinch strap with a snap hook. Remove the cover from the snap hook. 3.4 Anchor strap. Page 9

3.5 Route the cinch strap through the loop on the left lobe and attach the snap hook to the cinch ring. 3.5 Routing the strap. 3.6 Tighten the cinch strap by pulling on the free end until the flotation lobes are brought close together. 3.6 Adjusting the cinch strap. Page 10

3.7 The oral inflation tubes are on the right lobe. The valve has a rubber mouth piece and a knurled locking nut. Temperature changes may effect the pressure in the bladder. Use oral inflation to increase or relieve pressure from the bladder. Turn the knurled locking nut clockwise until it stops. Push the valve in with your mouth and blow air into the bladder to increase the pressure. Depress the valve to release pressure from the bladder. 3.7 Oral inflation. Tighten the knurled locking nut by turning it counter clockwise when you are finished. 3.8 For improved angle of flotation, put your arms through the straps that run down the sides of the bladder until the lobes are tight against your body. 3.8 Arm placement. Re m e m b e r: Panic and fatigue cause drowning. Stay calm and conserve your energy. Page 11

4. Inspection It is the responsibility of the air crewman to inspect the LPU-40 flotation collar before flight operations. Perform a preflight inspection prior to each flight and at intervals not to exceed 30 days. If damage is found during an inspection, the vest must be grounded until repaired. 1. Inspect the outside of the collar for: Cuts, tears, and abrasion damage Open seams and loose or broken stitching Contamination damage 2. Ensure that the entire length of the slide fastener is closed and there are no missing teeth. CAUTION: Do not open the flotation collar slide fastener for routine inspection. 3. Ensure that the beaded inflation handle is attached with 3 snaps fastened. 4. Ensure that the flotation collar is attached to the vest and all of the attachment snaps are fastened. 5. Maintenance Maintenance of the LPU-40 flotation collar consists of cleaning, service, and repair. The air crewman s responsibility for maintenance is limited to inspecting the outside components of the collar. Service and repairs shall be completed only by an authorized service station or the manufacturer. Remove the collar from the vest to wash the vest. 6. Storage Store your LPU-40 Flotation Collar on a clothes hanger away from direct sunlight in a dry, well ventilated place. Do not store your collar near sources of heat such as a radiator, or in a warm humid environment where mold or mildew can contaminate the vest. Page 12

7. LPU-40 Flotation Collar Repack Instructions 7.1 Preparation Repack the LPU-40 on a large flat surface big enough to accommodate the bladders when they are spread flat with no air in them. Orientation references the wearer s right and left. The required tools are: Replacement CO 2 bottle, Mil-C-25369, 29 gram, 2 each. Slide Fastener (zipper) for closing the Nomex case. Green safety clips, 2 each. Optional: clamps with soft rubber or plastic inserts to hold the bladder while packing. 7.1.1 7.1.2 7.1.3 7.1.4 7.1.5 Deflate the bladder by unlocking both oral tube valves. Depress the valves to release the pressure. While keeping the valves pressed in, gently compress the bladder with your hands and arms. This will force the air through the oral tubes. Remove the flotation collar assembly from the vest and harness. Lay the flotation collar flat on the table with the underside down. Ensure that the closing zipper is fully disengaged. Spread the Nomex case open and completely lay out the bladder. Remove and discard spent or punctured CO 2 cylinders. Visually inspect the Nomex case, inflatable bladder, and components of the flotation collar. Replace damaged bladder and/or components as necessary. 7.1.6 Place the actuator levers in the up-andarmed position. Install two new CO 2 cylinders (Mil-C-25369, 29 gram). Hand tighten the cylinders (avoid over tightening). Install a green safety clip on both of the actuators. 7.1.6 Installing the green safety clips. Page 13

7.1.7 It is important that all the trapped air be removed to aid in the repack of the bladder assembly and to provide for a compact and low profile collar. Remove trapped air by unlocking both oral tube valves and depressing them. A small electric vacuum pump used with the bladder evacuation hose adapter with dual holes (P/N: AMTC-M2026) may be used to aid in removal of the trapped air. 7.1.7 Removing the air from the bladders 7.1.8 Release and lock the oral inflation tubes in the closed and locked position. 7.2 Folding the Bladder Refer to Appendix D. for step-by-step illustrated drawings of Section 7.2: Folding the Bladder. 7.2.1 Lay the bladder out flat on the table. Position the actuators and the oral tubes facing up. 7.2.1 Preparing the bladder for folding. Page 14

Small shot bags or small plastic spring clamps will aid in maintaining the folds as you work on different areas of the bladder. 7.2.2 Fold the bottom of both the left and right lobes of the inflatable bladder under and along a horizontal line extending out from the bottom of the bladder attachment tabs. 7.2.2 Folding the bottom of the lobes. 7.2.3 Fold over the left lobes (the side with the CO 2 actuators) of the inflatable bladder towards the center of the assembly along a vertical line extending the length of the bladder. This fold should be up tight against the CO 2 actuators/cylinders (approximately 3 in width). Continue to fold the remainder of the left lobe onto itself in accordion fashion. Align the edges of the folds with either the inner vertical edge of the bladder or with the outer edge of the previous fold. When completed, there will be a total of three accordion-type folds that are 3 wide as measured along the left extension. Clamp the folds to hold them in place. 7.2.3 Folding the left side. Page 15

7.2.4 Take the right lobes (the side with the oral inflation tubes) and make a fold toward the center of the assembly along a vertical line extending the length of the inflatable bladder. This fold should be approximately 3 in width from the inner edge of the bladder. Continue to fold the remainder of the right lobe onto itself in accordion fashion. Align the edges of the folds with either the inner vertical edge of the bladder or with the outer edge of the previous fold. When completed, there will be a total of three accordion-type folds that are 3 wide as measured along the left extension. Clamp the folds to hold them in place. 7.2.4 Folding the right side. 7.2.5 Fold the top of the bladder next. From the top of the right extension, fold the bladder over and along a 45 angle from the horizontal. Repeat the previous step for the opposite side (top left lobe). 7.2.5 Folding the top. Page 16

7.2.6 Fold the top of the bladder under and along a horizontal line approximately 3 from the top of the neckline. Clamp the top folds to prevent undoing. 7.2.6 Folding the top. 7.3 Packing the Bladder in the Nomex Case 7.3.1 Wrap the Nomex case around the bladder. Fold the bladder concealment tab over the bladder. 7.3.1 Packing the bladder. 7.3.2 Thread size B nylon safety thread through the safety stitch eyelets. Install the slide fastener on the left-inner zipper cord and move the slider to the zipper retainer stop located at the bottom of the right extension. Ensure that the slider mates properly with the zipper retainer (i.e. flat to flat). 7.3.2 Installing the slide fastener. Page 17

7.3.3 Starting from the bottom of the right side, tuck the first 6 inches of the folded bladder into place inside the case (remove and replace clamps as necessary). 7.3.3 Stowing the bladder. 7.3.4 Tie the safety stitch with a surgeon s knot plus one square knot. Trim the tie 2 cm. above the knot. 7.3.4 Tying the safety stitch. 7.3.5 Place the cinch strap hook into the separate sleeve cover. Fan fold the cinch strap and pack it in the under side of bladder. Refer to Appendix E. for step-by-step illustrated drawings of folding the cinch strap. 7.3.5 Stowing the cinch strap. Page 18

7.3.6 Continue to tuck the bladder and close the case with the zipper until the entire bladder has been secured. Tie the safety stitch and remove the zipper slider from the casing. Fine tuning the folds may be required to obtain a proper fit. 7.3.6 Closing the Nomex case. 7.3.7 Snap the tab fastener closed. Ensure that both concealment tabs (one on each extension) are inside the Nomex case. 7.3.8 7.3.7 Closing the snaps. Notice that the CO 2 actuation lanyard forms a loop. The front of the loop has grip beads and the back of the loop is flat webbing with three holes. Insert the case-flap into the loop of the lanyard so the beads are located on top of the case flap. Align the three holes on the backside of the lanyard loop with the three snap sockets on the underside of the case flap. Secure the case flap to the snap studs on the front of the case. Ensure that the holes in the lanyard are around the snap sockets and the lanyard is secured between the Nomex case and the case flap. 7.3.8 Closing the handle. Page 19

8. Annual Inspection An inspection should be performed annually to ensure the flotation collar will perform when needed. It is the responsibility of qualified personnel to perform and log this inspection. The inspection can also be performed at the manufacturer. If damage is found during an inspection, the vest must be grounded until repaired. Repairs are limited to replacement of snaps and inflator replacement. All other repairs must be completed at the manufacturer. A functional test should be performed every third year. If a functional test is required, skip to section 9. The replacement equipment is: Replacement CO2 cylinders, 29 gram, 1/2 thread. (if needed) Green safety clip, 2 each. 8.1 Remove the flotation collar assembly from the vest and harness. 8.2 Lay the flotation collar flat on the table with the underside down. Spread the outer case open and completely lay out the bladder. 8.3 Preform leak test by connecting a single source of pressurized air to both bladder chambers and the bladder shall be inflated to 2.0 +/- 0.1 PSI using the oral inflation tubes. 8.4 After a minimum of 4 hours. Check pressure. Should not loose more than.4 PSI. CAUTION: If pressure drops more than.4 PSI, completely submerge the flotation collar in water to determine where leakage is occurring. If leakage occurs around inflator, replace inflator and gaskets and perform leak test again. If no determination can be made or bladder is leaking, return to manufacturer for repair. 8.5 Remove trapped air by unlocking oral tube valve and depressing them. A small electric vacuum pump used with the bladder evacuation hose adapter with dual hole (P/N: AMTC-M2026) may be used to aid in removal of the trapped air. NOTE: It is important that all the trapped air be removed to aid in the repack of the bladder assembly and to provide for a compact and low profile collar. 8.6 Lock the oral inflation tube in the closed and locked position. Page 20

8.7 Visually inspect the case front and back, inflatable bladder, handle, attachment straps, snaps and components of the flotation collar. 8.8 Remove CO2 cylinders and weigh. If functional is performed, discard and replace. 8.9 Ensure the actuator lever is in the up-and armed position. Install green safety clips on the actuator as shown. 8.10 Install two CO2 cylinders (29 gram. 1/2 thread). Hand tighten the cylinder (avoid over tightening). 8.11 Proceed to section 7.2 9. Functional Inspection A functional inspection should be performed every third year to ensure the flotation collar will perform when needed. It is the responsibility of the ALSE shop to perform and log this inspection. The inspection can also be performed at the manufacturer. If damage is found during an inspection, the vest must be grounded until repaired. Repairs are limited to replacement of snaps and inflator replacement, All other repairs must be completed at the manufacture. Functional inspection is as follows: 9.1 A functional can be performed with an individual wearing the vest with LPU-40 attached or on a table. 9.2 Pull the handle of the LPU-40 away from the bladder to inflate the flotation collar. NOTE: The LPU-40 should inflate fully within 10 seconds. 9.3 Adjust pressure to 2.0 +/- 0.1 PSI. Perform leakage test. Bladder should not loose more than.4 PSI in four hours. CAUTION: If pressure drops more than.4 PSI, completely submerge the flotation collar in water to determine where leakage is occurring. If leakage occurs around inflator, replace inflator and gaskets and perform leak test again. If no determination can be made or bladder is leaking, return to manufacturer for repair. 9.4 Remove the flotation collar from the vest if applicable. 9.5 Return to section 7.1.6 and complete. Page 21

Appendix A. LPU-40 Flotation Bladder Nomenclature Page 22

Appendix B. LPU-40 Casing Nomenclature Page 23

Appendix C. Bladder Evacuation Attachment Nomenclature Page 24

Appendix D. LPU-40 Bladder Folding Diagram Page 25

Appendix E. LPU-40 Folding Cinch Strap Diagram Page 26

Appendix F. LPU-40 Spare Parts List LPU-40 Spare Parts List Item Part Number Locking Clip, Safety Lower Gasket, Actuator Upper Gasket, Actuator Cap Nut, Actuator 8452AMA BLA-006 BLA-005 BLA-003 Inflator Cartridge, 29 grams 706103-15 Casing, AW FC 1005884-1 (UC) Bladder, AW 1005885-1 Anti-Abrasion Sleeve (covers attaching clip) 1005885-3 Anti-Abrasion Cover (covers inflator) BLA-008 Page 27