Modeling the Dependency of Oxygen Saturation Levels in Tissue on the Blood Flow of Capillary Units

Similar documents
Calculation of Trail Usage from Counter Data

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

LOW PRESSURE EFFUSION OF GASES adapted by Luke Hanley and Mike Trenary

New Generation System M, leading the World in the Non-Invasive Measurement of Critical Real-Time Parameters.

International Journal of Technical Research and Applications e-issn: , Volume 4, Issue 3 (May-June, 2016), PP.

Study of an Oxygenation Process in Capillary. in the Presence of Magnetic Field

Open Research Online The Open University s repository of research publications and other research outputs

Proceedings of Meetings on Acoustics

March Madness Basketball Tournament

ROSE-HULMAN INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering. Mini-project 3 Tennis ball launcher

Real-time Analysis of Industrial Gases with Online Near- Infrared Spectroscopy

Author s Name Name of the Paper Session. Positioning Committee. Marine Technology Society. DYNAMIC POSITIONING CONFERENCE September 18-19, 2001

Fluid Flow. Link. Flow» P 1 P 2 Figure 1. Flow Model

The Variation of Muscle Oxygen Consumption With Velocity of Shortening

The Physiologic Basis of DLCO testing. Brian Graham Division of Respirology, Critical Care and Sleep Medicine University of Saskatchewan

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

PHARMACOLOGY LABORATORY 2 PHARMACOKINETIC LABORATORY

660 mm Hg (normal, 100 mm Hg, room air) Paco, (arterial Pc02) 36 mm Hg (normal, 40 mm Hg) % saturation 50% (normal, 95%-100%)

March Madness Basketball Tournament

AN OVERVIEW OF RESPIRATION AND AN INTRODUCTION TO DIFFUSION AND SOLUBILITY OF GASES 1

COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE

Analysis of Shear Lag in Steel Angle Connectors

Alphasense Application Note AAN NDIR: Gas Concentration Calculation Overview

SHOT ON GOAL. Name: Football scoring a goal and trigonometry Ian Edwards Luther College Teachers Teaching with Technology

Autodesk Moldflow Communicator Process settings

LINEAR TRANSFORMATION APPLIED TO THE CALIBRATION OF ANALYTES IN VARIOUS MATRICES USING A TOTAL HYDROCARBON (THC) ANALYZER

Technical Note. Determining the surface tension of liquids by measurements on pendant drops

Aerodynamic study of a cyclist s moving legs using an innovative approach

Golf s Modern Ball Impact and Flight Model

1999 Microcomponents Technology SLYA017A

NHL & NHLPA Future Goals Program Hockey Scholar TM

Ermenek Dam and HEPP: Spillway Test & 3D Numeric-Hydraulic Analysis of Jet Collision

CHAPTER IV FINITE ELEMENT ANALYSIS OF THE KNEE JOINT WITHOUT A MEDICAL IMPLANT

A Hare-Lynx Simulation Model

Aalborg Universitet. Published in: Proceedings of Offshore Wind 2007 Conference & Exhibition. Publication date: 2007

Application Note AN-107

A Liter a Lung Measuring Lung Capacity

FLUORESCENCE DETERMINATION OF OXYGEN

Mass Spec will not Autotune

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

AC : A LABORATORY EXERCISE TO DEMONSTRATE HOW TO EXPERIMENTALLY DETERMINE THE OPERATING POINT FOR A FAN

Two-way Fluid Structure Interaction (FSI) Analysis on the Suction Valve Dynamics of a Hermetic Reciprocating Compressor

In memory of Dr. Kevin P. Granata, my graduate advisor, who was killed protecting others on the morning of April 16, 2007.

These two respiratory media (air & water) impose rather different constraints on oxygen uptake:

Pco2 *20times = 0.6, 2.4, so the co2 carried in the arterial blood in dissolved form is more than the o2 because of its solubility.

A STUDY OF THE LOSSES AND INTERACTIONS BETWEEN ONE OR MORE BOW THRUSTERS AND A CATAMARAN HULL

Novel empirical correlations for estimation of bubble point pressure, saturated viscosity and gas solubility of crude oils

Title: 4-Way-Stop Wait-Time Prediction Group members (1): David Held

Thermo Scientific Model 146i Principle of Operation

ANALYSIS OF AERODYNAMIC CHARACTERISTICS OF A SUPERCRITICAL AIRFOIL FOR LOW SPEED AIRCRAFT

At each type of conflict location, the risk is affected by certain parameters:

sensors ISSN

RESPIRATORY REGULATION DURING EXERCISE

Incorporating 3D Suction or Discharge Plenum Geometry into a 1D Compressor Simulation Program to Calculate Compressor Pulsations

OIL AND GAS INDUSTRY

Journal of Chemical and Pharmaceutical Research, 2014, 6(3): Research Article

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Tension Cracks. Topics Covered. Tension crack boundaries Tension crack depth Query slice data Thrust line Sensitivity analysis.

Lab # 03: Visualization of Shock Waves by using Schlieren Technique

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

ALVEOLAR - BLOOD GAS EXCHANGE 1

13.1!"#$#%"&'%()$*+%,+-.$+/*$#

5.0 Neutral Buoyancy Test

DOE Golfer Experiment

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Optimizing Compressed Air Storage for Energy Efficiency

PICU Resident Self-Study Tutorial The Basic Physics of Oxygen Transport. I was told that there would be no math!

Well Control Modeling Software Comparisons with Single Bubble Techniques in a Vertical Well

Advanced Hydraulics Prof. Dr. Suresh A. Kartha Department of Civil Engineering Indian Institute of Technology, Guwahati

New power in production logging

(a) (i) Describe how a large difference in oxygen concentration is maintained between a fish gill and the surrounding water.

Low Speed Wind Tunnel Wing Performance

Vertical in situ profiles of nitrate and oxygen in the northern Japan Sea

Applying Hooke s Law to Multiple Bungee Cords. Introduction

Blast Damage Consideratons for Horizontal Pressure Vessel and Potential for Domino Effects

Using Markov Chains to Analyze a Volleyball Rally

NUMERICAL SIMULATION OF STATIC INTERFERENCE EFFECTS FOR SINGLE BUILDINGS GROUP

Australian Journal of Basic and Applied Sciences. Pressure Distribution of Fluid Flow through Triangular and Square Cylinders

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Grade: 8. Author(s): Hope Phillips

PHYS Tutorial 7: Random Walks & Monte Carlo Integration

INSTRUMENT INSTRUMENTAL ERROR (of full scale) INSTRUMENTAL RESOLUTION. Tutorial simulation. Tutorial simulation

An investigation of kinematic and kinetic variables for the description of prosthetic gait using the ENOCH system

FIG: 27.1 Tool String

Finite Element Analysis of an Aluminium Bike Frame

Analysis of Pressure Rise During Internal Arc Faults in Switchgear

2008 Excellence in Mathematics Contest Team Project B. School Name: Group Members:

GUIDE TO THE ARCTIC SHIPPING CALCULATION TOOL

CHAPTER 7 : SMOKE METERS AND THEIR INSTALLATIONS

Analysis of Traditional Yaw Measurements

Homeostasis and Negative Feedback Concepts and Breathing Experiments 1

Gas Gathering System Modeling The Pipeline Pressure Loss Match

MODELLING OF FUME EXTRACTORS C. R.

Determination of the wind pressure distribution on the facade of the triangularly shaped high-rise building structure

Engineering Practice on Ice Propeller Strength Assessment Based on IACS Polar Ice Rule URI3

Improving distillation tower operation

Naval Postgraduate School, Operational Oceanography and Meteorology. Since inputs from UDAS are continuously used in projects at the Naval

Lab Orientation and the Surface to volume ratio in animals

RESPIRATORY PHYSIOLOGY, PHYSICS AND

Chapter 12 Practice Test

Transcription:

Modeling the Dependency of Oxygen Saturation Levels in Tissue on the Blood Flow of Capillary Units University of Western Ontario Department of Medical Biophysics Ryan Divigalpitiya Supervisor: Dr. Dan Goldman 1

Table of Contents 1 - Introduction! 1.1 - Motivation for a Model that Predicts Oxygen Saturation 2 - Background! 2.1 - Biological Background!! 2.1.1 - Microvasculature!! 2.1.2 - Blood Properties! 2.2 - Basic Modeling! 2.3 - Background on Ellsworth et alʼs research Measurement of Hemoglobin Oxygen Saturation in Capillaries 3 - Objectives 4 - Methods & Approach! 4.1 - Components of MATLAB Model!! 4.1.1 - Geometry!! 4.1.2 - Tissue Properties!! 4.1.3 - Incorporating the Saturation Equation 5 - Results! 5.1 - Contour Plots! 5.2 - Finite Sensitivity! 5.3 - Resolution 6 - Discussion! 6.1 - Is this Basic Model Working?! 6.2 - Finite Sensitivity! 6.3 - Resolution! 6.4 - Future Ideas 7 - Conclusion 7 - References 2

Acknowledgements I would like to thank Dr. Dan Goldman, my supervisor, who was involved with the project and provided the much needed guidance and help I needed. It has been a great learning experience. Ryan Divigalpitiya, April, 2011 3

1 - Introduction! Oxygen is one of the few elements human beings require constantly in order to survive longer than a few minutes. With such a critical dependency on oxygen, diseases that restrict or interfere with oxygen delivery throughout our body pose immediate dangers to our short term health. This has been a platform of motivation to increase our understanding of the dynamics of oxygen transport and oxygen levels in the body.! When dealing with a more local scenario of de-oxygenation such as necrosis in tissue, how researchers can gauge levels of oxygen is by measuring a property known as oxygen saturation in tissue. Necrosis occurs when oxygen saturation levels have been zero for too long and the tissue has started to die. There are various diseases that exhibit these kind of results as their symptoms such as Sepsis or Systemic Inflammatory Response Syndrome (SIRS). 1.1 - Motivation for a Model that Predicts Oxygen Saturation! If we are able to create a software model that can predict the oxygen saturation levels in various tissue under various states, we would not only be able to broaden our understanding of the dynamics of oxygen saturation but, more significantly, we could utilize such a model to aid us in revealing treatments and cures for diseases like sepsis that we were unable to see before. This vision is a vision of the ultimate goal of what I want to achieve with this project but I will outline further on why its more wise to consider modeling a simpler case first. 4

2 - Background 2.1 - Biological Background 2.1.1 - Microvasculature! The primary site of oxygen diffusion into the tissue occurs at the microvascular sites known as the capillaries. Here, red blood cells usually travel one at a time from the inlet of the capillary to the outlet and release their oxygen molecules along the way. The dimensions of an average capillary is roughly about 6-8 μm in diameter where a red blood cell is also roughly about 6-8 μm in diameter 1. The shape of a capillary is essentially cylindrical. 2.1.2 - Blood Properties! Red blood cells are the carriers of oxygen throughout the microvasculature. However, they require the help of a protein molecule in order to sufficiently bind enough oxygen molecules to be transported in the blood. This protein is called Hemoglobin and is an iron-containing, multi-subunit protein that makes up 97% of a red blood cells dry content 2. It is generally found in two states. 1) Saturated - the Hemoglobin is bounded to oxygen, 2) Unsaturated - the Hemoglobin is unbounded to oxygen.! This is effectively what oxygen saturation in tissue is based on - if we can measure the amount of hemoglobin with bounded oxygen, we know the oxygen saturation at that point in the tissue.! Another important and relevant tissue property is Hematocrit. Hematocrit is the fraction of blood volume occupied by red blood cells. The rest of the blood is occupied by other species such as blood plasma. 5

2.2 - Basic Modeling! Before one attempts to model complex scenarios that reflect diseases and illnesses, itʼs wise to first attempt to model the simplest scenario first and see if doing so is feasible. Once successful, then we are in a position to generate ideas for the next, more complicated revision of the model.! So how did I define what entails a simple model? First, I eliminated diseases altogether and decided to model healthy tissue (tissue with no disease). I also limited the microvasculature to one single capillary in my healthy tissue because, otherwise, modeling an entire capillary network would have been another substantial source of complexity to worry about.! Next, I considered what my input and output were going to be in the context of this project. The input has to be some measured tissue property thatʼs related to the oxygen saturation. The output will be mean oxygen saturation levels. The computational algorithm that computes the saturation based on the input was essentially what I had to determine for this project. To help me with this part I based the algorithm on research conducted by Ellsworth et al 3. 2.3 - Background on Ellsworth et alʼs research Measurement of Hemoglobin Oxygen Saturation in Capillaries 3! Ellsworth et al conducted research on determining oxygen saturation in tissue by measuring the optical densities of the tissue. Essentially, they shined specific wavelengths of light through tissue and used a detector to measure the transmitted light intensity. The wavelength were selected based on the absorption spectra of 6

hemoglobin. Using the Optical Density equation (OD) which equals Log(I/Io) where I = transmitted intensity, and Io = initial intensity, the OD was calculated for the tissue at that specific point in the tissue. Since, the measured OD is the OD of hemoglobin which can then be correlated to the saturation levels in the capillaries, Ellsworth et al managed to express the relationship between optical density and oxygen saturation in this equation: S = -1.56*(OD431/OD420)+1.78! This Saturation Equation was selected to be the heart of the modelʼs computational algorithm. It would be incorporated into the model such that, one would only have to measure the optical density of the tissue of interest once, input the values into model and model should be able to estimate the saturation of oxygen everywhere else in the tissue.! Thus, what this means is that the estimation of the saturation is dependent on the limitations of the equipment used to make that initial optical density measurement. Certain parameters for the equipment may limit the accuracy of the saturation estimation. One very important parameter, called the Finite Sensitivity of the detector, which is a measure of the minimum intensity of light the detector can detect, could be a limiting factor in the accuracy of modeling the saturation levels. The choice of finite sensitivity in the detector we use may be influenced by the tissue properties in the tissue of interest and would, thus, be interesting to investigate if there are any connections between the two. Also, very common in models of this nature, is the impact of selecting an appropriate resolution to run the model at. Too high a resolution would cause the model to take a long duration of time to compute the answer but may reveal a 7

very accurate answer and vice versa. It would also be interesting to investigate if there are any relationships between the selected resolution and limitations of finite sensitivity of the detector used. 3 - Objectives With that said, my objectives for this project are the following: To create a software computational model that accurately predicts mean O2 tissue saturation based on the Saturation Equation A. Use the model to determine how simulated hematocrit levels affect the required finite sensitivity needed to accurately predict mean saturation B. Use the model to determine how resolution of the model (the size of the voxels that make up the 3D tissue) affect the accuracy of predicting the required finite sensitivity C. Use what was learned in creating this simplified model to generate ideas on how to improve the model in an attempt to improve its realism and applicability 4 - Methods & Approach! The software package that was utilized is called MATLAB which is a matrixdriven program used in a wide variety of applications. 4.1 - Components of MATLAB Model: 4.1.1 - Geometry! To create the geometry of the model, I constructed 3D matrixes to the dimensions of a rectangular prism of 25 μm by 25 μm by 200 μm. I then defined a cylinder inside this tissue with the same depth of 200 μm and a radius of 3 μm (6 μm diameter). This cylinder represented the idealized capillary inside the healthy tissue. 8

4.1.2 - Tissue Properties! The next step was to simulate the relevant tissue properties. Hemoglobin concentrations were simulated by assuming a hemoglobin concentration of 20 mmol/l inside every red blood cell 3. Hematocrit levels were simulated by assuming levels between 0.3 and 0.5 which I arbitrarily selected based off common reported values in the literature. Once, hemoglobin and hematocrit levels were incorporated, I made a simplified assumption that the saturation would decrease linearly as the blood moves along the capillary. That way, I could verify myself if the code is functioning properly because I would be able to independently calculate what the predicted answer should be and compare it to the modelʼs answer. Another simplification I made was to neglect red blood cell flow velocity. 4.1.3 - Incorporating the Saturation Equation! The final step was incorporating the Saturation Equation into the model. It was incorporated by first calculating all the individual OD431 and OD420 using Beer-Lambertʼs law: conc x L x e, where concentration, in this context, would be the concentration of hemoglobin multiplied by the hematocrit; L is the thickness of the capillary (the diameter); and e is the extinction coefficient of hemoglobin at either OD431 or OD420 depending on which one is being calculated. Then, assuming the saturation is linearly decreasing, the model would use the Saturation Equation to estimate the mean saturation of the entire tissue. However, after I preliminarily tested it out, there were some errors in the calculated saturation - the calculated saturation was always 2 9

decimals off from the correct answer. For example, if I knew the calculated saturation should be 0.5, the model would calculate 0.4522. I soon realized that the extinction coefficients I was using were reported in the literature with an error range as follows: for the 420-nm filter, 120.0 ± 8.7 and 112.6 ± 8.3 and for the 431-nm filter they were 62.8 ± 5.0 and 136.7 ± 8.1. After discovering the error ranges, I varied the extinction coefficients within these ranges until the model computed an answer of 0.5000. Thus, I optimized the coefficients which improved the accuracy to an acceptable level.! As I started to achieve a stable and accurate model, I ran my model against my objectives and collected the outputted results. 10

5 - Results 5.1 - Contour Plots Figure 1. Estimated Saturation at Half Length of Capillary where Actual SO2 = 0.3. Colour bar refers to level of saturation, thus, Figure 1 shows an estimated saturation of 0.3. Figure 2. Variation of Saturation Along Capillary with Inlet SO2 of 0.5 and Outlet SO2 of 0.1. Colour bar refers to base of the log of ratio of intensities, I/Io. Inlet is on right side. 11

Figure 3. Estimated Saturation at Half Length of Capillary where Actual SO2 = 0.5. Colour bar refers to level of saturation, thus, Figure 1 shows an estimated saturation of 0.5. Figure 4. Variation of Saturation Along Capillary with Inlet SO2 of 0.8 and Outlet SO2 of 0.2. Colour bar refers to base of the log of ratio of intensities, I/Io. Inlet is on right side. 12

! In order to generate these results, inlet and outlet values of saturation were inputed into the model. With these inputs, the model calculated and estimated the saturation throughout the modeled tissue where Figures 1 through 4 display these outputted saturation estimates.! Figure 1 displays a circular cross section of the modeled capillary. The figure is not entirely circular due to selection of resolution and artifacts in the generated figure (however, the artifacts are not interfering with what is being shown). By observing figure 1ʼs colour bar, we can see that the model has estimated the saturation level to be about 0.3 at the half way point along the capillary.! Figure 2 displays a cylindrical cross section of the modeled capillary where the figure succeeds to show that the variation in saturation along the capillary can be observed as decreasing from the inlet toward the outlet. The colour bar reference is presented using the base of the log of ratio of intensities, I/Io. How one reads the color bar is as follows. A small value (ie. approaching 0) for the ratio of I/Io indicates high absorbance ie. high saturation at that point along the capillary. Also, a small value for the ratio of I/Io indicates larger negative numbers on the colour scale, for example, -6 or -7 as oppose to -1 or -2. Thus, larger negative numbers on the colour bar indicate higher saturation, or rather, darker blue colours indicate high saturation and lighter blue colours indicate lower saturation. This makes sense since the inlet is on the right side of the figure, has the highest saturation and, thus, has the darkest colour. Figures 3 and 4 are two more similar examples with different inputted values. 13

5.2 - Finite Sensitivity These finite sensitivity settings are not sensitive enough to accurately estimate the mean SO2 Actual SO2 = 0.5 Estimated SO2 should be 0.5 Predicted Saturation (Saturation Fraction) Figure 5. Predicted Saturation VS. Finite Sensitivity. Actual SO2 = 0.5 meaning an accurate estimate of the saturation would be 0.5. Hematocrit was set to 0.5. Predicted Saturation VS. Finite Sensitivity of a Detector with Varying Levels of Hematocrit 0.500 0.435 0.370 0.305 0.240-30.0-22.5-15.0-7.5 0 Finite Sensitivity (Log(Im/Io)) Hematocrit Levels (RBC Volume Fraction) 0.30 0.35 0.40 0.45 0.50 Figure 6. Predicted Saturation VS. Finite Sensitivity of a Detector with Varying Levels of Hematocrit. 14

! The x-axis on both Figure 5 and 6 again use the base of the log of the ratio of intensities I/Io. Thus, values to the left of the x-axis indicate high finite sensitivity. Values to the right of the x-axis indicate low finite sensitivity. To determine the effect of hematocrit levels on finite sensitivity, values within the range of 0.3 to 0.5 hematocrit were inputted in the model and resulting figure, figure 6, was outputted. It is observed that the higher the level of hematocrit present in the tissue, a higher finite sensitivity is required to detect the transmitted intensity in order to accurately predict mean SO2. To further bring out this trend, the data points corresponding to the point right before each curve starts to decrease (ie. become inaccurate) was plotted against the increase in hematocrit levels: Required Finite Sensitivity (Log(Im/Io)) Required Finite Sensitivity for Specified Hematocrit Levels -12-15 -18-21 -24 0.30 0.35 0.40 0.45 0.50 Hematocrit (RBC Volume Fraction) Figure 7. Required Finite Sensitivity for Specified Hematocrit Levels 15

5.3 - Resolution Predicted Saturation VS. Finite Sensitivity for Various Selected Resolutions 0.500 Predicted Saturation (Saturation Fraction) 0.435 0.370 0.305! 0.240-30.0-22.5-15.0-7.5 0 Finite Sensitivity (Log(MinIm/Io)) Selected Resolutions: Resolution halved Initial resolution Double resolution Quadruple resolution Figure 8. Predicted Saturation VS. Finite Sensitivity for Various Selected Resolutions.! In Figure 8, a graph similar to Figure 6 is presented except here resolution is being varied to observe its effect on finite sensitivity. An initial resolution was first selected and was then increased and decreased to produce the graph above. Figure 8ʼs legend specifies the exact factors of increase and decrease in resolution that were applied. 16

6 - Discussion 6.1 - Is this Basic Model Working?! The first question that should be investigated is, did I successfully create a model that relatively accurately predicts mean saturation? How one simply answers this question is by selecting an inlet and outlet saturation to be inputted in the model knowing before hand what the modelʼs outputted answer should be, and then run the model to see if the outputted answer is on par with the pre-determined answer.! Before outputting figures 1 and 3, I had chosen an inlet and outlet saturation value of 0.5 and 0.1, respectively. Knowing the mean SO2 of those two values (ie. the saturation half way along the capillary) is 0.3, the model was executed and the outputted contour plots estimated that the saturation is 0.3, thus, being on par with my pre-determined answer. Figures 2 and 4 also visually verify that the model is modeling the saturation decrease along the capillary as red blood cells travel along the capillary and release their oxygen. 6.2 - Finite Sensitivity! An important note to make with this model is that it relies on a detector/apparatus to measure an optical density reading of the tissue first in order to model the saturation of the rest of the tissue. Thus, the sensitivity of that detector can limit the accuracy of the estimated saturation altogether, regardless of how accurate and realistic the computational model may be. Figure 5 demonstrates this. With a fixed hematocrit of 0.5 and a known saturation of 0.5 (ie. all variables of the model fixed), Figure 5 shows how accurate various finite sensitivities are at estimating the saturation. For very fine 17

sensitivities (ie. detectors that can detect very small intensities of transmitted light), an accurate estimate of 0.5 saturation is achieved. For courser sensitivities (ie. detectors that cannot detect very small intensities, only large intensities of transmitted light), the curve experiences a quick drop which indicates a significant amount of error being introduced in the estimation as the finite sensitivity worsens (moving towards the right of the x-axis). This intuitively makes sense since a detector that only has the ability to detect transmitted minimum intensities of, say, X and then a transmitted intensity of Y strikes this detector where Y < X, the signal noise and system noise in the detector would be larger than the detected signal, thus, meaning it would never be detected.! Figures 6 and 7 go on to investigate the question what properties of the tissue affects finite sensitivity?.! Figures 6 and 7 clearly demonstrate that as levels of hematocrit increase in the tissue, a more sensitive detector is required to maintain accurate estimations of the saturation. Why is this? The answer can be found by investigating how increasing hematocrit affects the Optical Density equation or Beer- Lambertʼs law: OD = conc x L x e. An increase in hematocrit simply means an increase in red blood cells and, thus, hemoglobin. Essentially, there is an increase in concentration of the species that absorbs the light intensities passing through the tissue. With increases in the amount of light intensity absorbed, less light is being transmitted to the detector which, in turn, will require a more sensitive detector to pick up the diminished transmitted light intensity. Thus, this is why we observe Figure 7ʼs trend: an increase in hematocrit level requires an increase in the finite sensitivity in order to maintain an accurate estimation of the saturation because the transmitted intensity gets weaker. 18

! What we can take away from these findings is that we can actually use the model to predict for us what finite sensitivity we should be using in our detector in order to achieve accurate estimations of saturation for specific hematocrit levels. 6.3 - Resolution! Figure 8 demonstrates another important question: what properties of the model may affect choice of finite sensitivity?. An important factor is the chosen resolution which is shown, in Figure 8, at first glance to have a significant impact on the accuracy of estimating the saturation. By first looking at the halved resolution curve, an obvious spike occurs when you move from left to right along the x-axis and then back down again. It has now been established conceptually that the curve should be continuously decreasing as you move from left to right on the x-axis since worse finite sensitivities should give worse saturation estimations. This spike, therefore, indicates that having a very course resolution introduces a significant amount of error in the estimation of the mean when using slightly lower sensitivities. Also, more importantly, the curve starts to drop much sooner than the rest of the other curves which greatly limits what finite sensitivities you can work with to get an accurate estimation of the saturation.! The initially selected resolution and the doubled resolution curves do not show too much deviation at the lower sensitivities and the quadruple resolution curve displays the smoothest curve out of all curves. However, there is not much difference between these 3 curves in terms of when they start to drop and become inaccurate - they all start to drop at roughly the same point on the graph. Only the halved resolution curve drops significantly sooner than the rest of the other 3 curves. What this tells us is that 19

resolution does not play a major role in the accuracy of estimating saturation if you are utilizing resolutions at or above the initial resolution. What this implies is that estimated saturation is not affected by increases in resolution, but how can one explain this? Recall, what the model is estimating here is the mean saturation of the modeled tissue. The mean value of the saturation is most likely being resistant to increases in the resolution because it is the mean. One way to test if this is the case is to determine specific saturation values at specific points in the model (other than the mean) and observe if the values change with changes being made to the resolution. However, I am more interested in overall saturation (ie. mean saturation) of the modeled tissue and so doing so would stray away from my original objective. 6.4 - Future Ideas! As I stated earlier, an important objective of this project is to generate ideas on how to improve the model in an attempt to enhance its realism and applicability. One area that I focused on during the phase of brainstorming ways to improve this model was the algorithms used to govern the decrease in saturation as you move along the capillary. Currently, the model relies on a simple linear decrease in saturation as you move from the inlet to outlet. Of course, in real life, this is not the case and can, therefore, serve as one of the first areas of the model in which is improved upon. The only way to do so is to determine the true function that governs the decrease in oxygen saturation as you move along the capillary: oxygen saturation as a function of position, S(x). I brainstormed an idea on how to utilize Ellsworthʼs Saturation Equation to do so and can be summarized in the following diagram: 20

Figure 9. Experimentally Deriving S(x) Function! Essentially, one can measure the OD at various points along the capillary, extract the saturation, and plot the saturation as a function of position. Then, using computer graphing software, fit a line along the data points in the plot and extract the equation. This equation, S(x), will be the equation that governs how saturation drops as a function of position along the capillary. Then, incorporate this function S(x) in the modelʼs algorithms. Once this is done, I would only need to measure the OD at one point in the capillary (ie. take only one measurement), calculate the saturation, input that inlet saturation value into the model and then the model will be able to more accurately 21

estimate the saturation at any point in that capillary just from one experimental measurement. 7 - Conclusion! In sum, the contour plots show accurate estimates of the saturation levels indicating that the model is performing appropriately. It was also demonstrated that the model can be used to predict an appropriate selection of finite sensitivity depending on what hematocrit levels will be dealt with. Resolution was also shown to not have a significant effect on estimated saturation unless the resolution is decreased by half of the initial resolution I used. I have also elaborated on an important future idea on how to improve the practicality of the model by determining a way to derive the true decrease in saturation function. There are many other areas of the model that can be improved for future revisions but, as of now, I believe that a solid foundation to a useful and realistic model with lots of future potential for applications has been laid out by initializing this project. Some of those next steps toward future improvements would include the inclusion of complex geometry and multiple capillary networks (which my colleague Eugene Joh investigated himself in his 6 week project) and hopefully, the successful modeling of devastating diseases to better our understanding on how to cure them once and for all. 22

8 - References 1. Professor Dwayne Jackson - MBP 3501 Lecture Notes Biophysics of Transport Systems 2. Dominguez de Villota ED, Ruiz Carmona MT, Rubio JJ, de Andrés S (December 1981). "Equality of the in vivo and in vitro oxygen-binding capacity of haemoglobin in patients with severe respiratory disease". Br J Anaesth 53 (12): 1325 8. doi:10.1093/ bja/53.12.1325. ISSN 0007-0912. PMID 7317251 3. Mary L Ellsworth, Roland N. Pittman & Christopher G Ellis, Measurement of hemoglobin oxygen saturation in capillaries, 0363-6135/87 1.50 Copyright 1987 the American Physiological Society 4. Daniel Goldman, Ryon M. Bateman, and Christopher G. Ellis, Effect of sepsis on skeletal muscle oxygen consumption and tissue oxygenation: interpreting capillary oxygen transport data using a mathematical model,am J Physiol Heart Circ Physiol 287: H2535 H2544, 2004. 23