EMISSION CHAMBERS. Bulk and Surface Emission Detection for the RAD7 User Manual

Similar documents
SOIL GAS PROBE. In-Ground Radon Detection Accessory for the RAD7. DURRIDGE Hardened Steel Soil Gas Probe AMS Stainless Steel Soil Gas Probe

DURRIDGE STAINLESS STEEL SOIL GAS PROBE

ELEVATION CORRECTION FACTORS FOR RADON MONITORS*

Electronic Radon Detector

CORESTA RECOMMENDED METHOD N 6

BIG BOTTLE SYSTEM High Sensitivity Radon in Water Accessory for the RAD7 With Aerator Cap Revision B. User Manual

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Inert Air (N2) Systems Manual

RAD7 RADON DETECTOR. User Manual. It is recommended that the unit be returned to DURRIDGE Co annually, for recalibration.

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

DTC P0442 EVAPORATIVE EMISSION CONTROL SYSTEM LEAK DETECTED (SMALL LEAK) DTC P0455 EVAPORATIVE EMISSION CONTROL SYSTEM LEAK DETECTED (GROSS LEAK)

PRC CO ² -LASER PRESENTATION

PERFORM Operating Document

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Self-operated Pressure Regulators for special applications

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

CentriFlow Meter Integrated Air Entrainment System

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Cover Page for Lab Report Group Portion. Pump Performance

to the LI-6400 Sensor Head

PERFORM Operating Document

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

OPERATING INSTRUCTIONS

13. Evaporative Emission Control System

Leak testing of Valves. Standards for acceptable Rates of Valve Leakage

Floor Drinking Systems

icon i150 / i350 Installation / Operation Manual

PMI Pulse Decay Permeameter for Shale Rock Characterization Yang Yu, Scientist Porous Materials Inc., 20 Dutch Mill Road, Ithaca NY 14850

TEST SPECIFICATION NYT-909-C

Pilot Check Valve: Metal Body Type

Instruction Manual. Pipe Friction Training Panel

Instruction and Maintenance Manual

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Pressure Reducing Valve for Steam Type 2333 A

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Irrigation &Hydraulics Department lb / ft to kg/lit.

3-Way Pressure-Reducing Cartridge, Size 2 4

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

BS ml Bottle Sampling Unit

PMI Advanced Automated. Pulse Decay Permeameter APDP-10K-HP-101. Not just products... Solutions!

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

92831 TEL: (714) FAX:

MyControl Bathing System Signature Series

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

ACV-10 Automatic Control Valve

I T T Pressure Reducing Valve WARNING INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

Test Report # Rev 0. Adiabatic Compression In Nitrogen Service

INSTRUMENTS A THERMAL MASS FLOW SENSOR USING A CONSTANT DIFFERENTIAL TEMPERATURE ABOVE THE AMBIENT GAS TEMPERATURE

Vapor Sorption Analyzer

Model: 43T. Bermad Pressure Relief Valve

Standard Test Methods for Water Vapor Content of Electrical Insulating Gases by Measurement of Dew Point 1

CSA Sample Draw Aspirator Adapter Operator s Manual

Aperval Pressure Regulators

Chapter 10: Bidirectional Flow Controls

RK-IR Sample Draw Aspirator Adapter Operator s Manual

Product Test Report F.A. Lennon Drive December 2015 Solon, Ohio U.S.A. Page 1 of 7. Valve Series Description Test Pressure Test Qty.

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017

T004.BioTector TOC Analyzer Pressure and Flow Test failure analysis

VACUUM REGULATORS CONTENTS

Description Advanced Features Typical Applications

Operation and Maintenance Manual. First Defense and First Defense High Capacity. Vortex Separator for Stormwater Treatment

Instruction and Maintenance Manual

Customer Responsibilities

Physics Experiment 17 Ideal Gas Law Qualitative Study

Bermad Model:

Fisher DVI Desuperheater Venturi Inline

2 Sentry MCL Installation, Operation & Maintenance

Training. Testor Training Manual

Copyright, 2005 GPM Hydraulic Consulting, Inc.

This test shall be carried out on all vehicles equipped with open type traction batteries.

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Leak free Pipe Rupture Valve for Excavators

Making OTR Measurements in Bottles using the. BottlePerm Fixture

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

NeoNatalie Resuscitator Oxygen kit

Air Operated Hydraulic Pumping Systems to 50,000 psi

Operation Manual Piston Sensed Gas Pressure Regulators

Rhino VE CE Bulk Unloader Operator s Card

Bruker BioSpin NMR CASE. System Requirements Manual. Version. NMR Spectroscopy. think forward

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

HumiSys HF High Flow RH Generator

Valve Proving System VDK 200 A S06*

PANACEA P100 LOW PRESSURE USER MANUAL

Oxygen Usage Best Practice Guide

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

UsER manual for Watersens ph -REDOX

RD(H)20/25 Pressure-Reducing Regulator User Manual

Valve INV-907. Instructions. 1 Introduction. 2 Installation. Safety. Unpacking. Installing the valve

OPERATING INSTRUCTIONS

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Rev. A Jul 07 Part # SS VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL

Cover Page for Lab Report Group Portion. Head Losses in Pipes

Additel 780 Series Pressure Controller

Agilent Auxiliary Gas Module AGM 2. User s Guide

Transcription:

EMISSION CHAMBERS Bulk and Surface Emission Detection for the RAD7 User Manual

TABLE OF CONTENTS INTRODUCTION 3 1 SYSTEM CONFIGURATION 4 1.1 Closed Loop Configuration 4 Fig. 1 Emission Chamber Closed Loop Configuration 4 Fig. 2 Closed Loop Configuration For Very Low Emission Rates 5 1.2 Open Loop Configuration 5 Fig. 3 Emission Chamber Open Loop Configuration with DRYSTIK 6 2 BULK EMISSIONS 7 Fig. 4 Bulk Emission Chamber Uncovered 7 3 SURFACE EMISSIONS 8 Fig. 5 Hard Surface Emission Chamber 8 Fig. 6 Soil Surface Emission Chamber 8 4 TECHNICAL SPECIFICATIONS 9 4.1 Bulk Emission Chamber 9 4.2 Surface Emission Chamber 9 Table of Contents 2

INTRODUCTION With its internal pump, sealed sample path, and inlet and outlet connectors, the RAD7 is well suited to the measurement of radon emissions from a variety of objects and surfaces. Furthermore, the option to count only polonium-218 decays means that dynamic measurements can be clean, and not complicated by long-half-life events. DURRIDGE offers a series of Emission Chamber accessories to facilitate these measurements. The Bulk Emission Chamber is a solid metal box with an airtight seal, and it is intended for the measurement of radon from dirt samples and objects. In addition, two Surface Emission Chambers are offered: the Soil Surface Emission Chamber is a plate-like device with a metal rim which forms a tight seal when placed upon soft ground surfaces. A similar device for hard surfaces uses rope caulk to form a seal against flat smooth surfaces such as concrete. Each DURRIDGE Emission Chamber creates an enclosed space from which the RAD7 may draw air. The air sample passes through the a tube of desiccant and an inlet filter, and into the RAD7 s measurement chamber. The air may then be returned to the enclosure from the RAD7 outlet, to form a closed loop. Alternatively, an open loop configuration will allow the air being drawn from the enclosure to be replaced with zero air from a cylinder, or with ambient air, which should have a low but known radon concentration. Introduction 3

1 SYSTEM CONFIGURATION 1.1 Closed Loop Configuration A closed loop configuration allows radon to build up within an airtight system involving an Emission Chamber, RAD7, and Laboratory Drying unit. First, the system is thoroughly purged. Once the purge is complete, the loop is sealed as shown in Figure 1. The radon concentration within the loop is monitored in SNIFF mode, with a short (e.g. 15 min.) cycle time, for a few hours. It is necessary to know the total volume of the closed-loop system. For this purpose, the volume inside the RAD7 may be taken as 800mL. The initial rate of increase in radon concentration (neglecting the first 15-min cycle), multiplied by the internal air volume, gives the rate of emission of radon. A reduction in the slope, as the radon level builds up, may be due to leaks in the system, or to a reduction in the net emission. DURRIDGE s CAPTURE software can be used to position a slope line on the radon graph and inspect the change in radon concentration over time. The line should be set to begin after the initial response delay and before any observable drop from either leakage or decay. CAPTURE will express the slope of the line in the units of your choice. Very low emission rates can be measured by placing the sample in an airtight container with sealable inlet and outlet valves, and allowing the ingrowth of radon to occur over at least a week (after which the ingrowth must be calculated) and preferably a month or more (after which the ingrowth may be assumed to have reached equilibrium). The container is then connected to the RAD7 in a closed loop, as shown in Figure 2 on the next page. The valves are then opened and the RAD7 measures the radon concentration. The concentration will rise as the radon is distributed around the loop. Eventually the concentration will settle to a slowly decreasing value. Fig. 1 Emission Chamber Closed Loop Configuration Section 1 System Configuration 4

1.2 Open Loop Configuration Fig. 2 Closed Loop Configuration For Very Low Emission Rates In an open loop configuration, fresh air passes through the Emission Chamber and picks up radon on its way to the RAD7. Here it is necessary to first establish a low but known rate of air flow. This can be achieved using a DRYSTIK, as shown in Figure 3 on the next page. The DRYSTIK s Low Airflow port should be used, and its duty cycle should be set to a low value, such as 10%. Alternatively, if a cylinder of zero air, or nitrogen, is present, a pressure reduction valve may be used to control the flow rate of the air entering the apparatus, and a flow meter should be used to confirm the flow rate. If neither a DRYSTIK nor an air cylinder is available, the RAD7 s internal pump may be turned On, for a continuous flow. (Otherwise the RAD7 s internal pump should remain Off.) Any configuration not involving a DRYSTIK should use a flow meter downstream of the RAD7, to confirm the rate of air flow. In all cases, a tube of activated charcoal should be placed just upstream of the Emission Chamber. This will remove any radon from the air entering the Emission Chamber, ensuring that all of the radon entering the RAD7 comes from the material inside the Emission Chamber itself. If activated charcoal is not available, another option is to conduct two tests, one with the Emission Chamber empty, so that the results may be compared. Once a steady state has been achieved, a long-term measurement may be made. The rate of radon emission will equal the radon concentration reported by the RAD7, multiplied by the flow rate. The precision of the measurement will depend on the radon concentration and the duration of the process. Section 1 System Configuration 5

Fig. 3 Emission Chamber Open Loop Configuration with DRYSTIK Section 1 System Configuration 6

2 BULK EMISSIONS The DURRIDGE Bulk Emission Chamber is an airtight box with two well separated hose connectors. The material to be tested is placed in the chamber, which is then connected to the laboratory drying unit, and thence to the inlet filter on the RAD7. The other box connector has tubing attached, which is either connected to the RAD7 outlet for closed-loop operation, or to a cylinder of zero gas or ambient air for open-loop operation. Note that the emission of radon from bulk material may be affected by pressure fluctuations and by changes in temperature and humidity. All of these parameters can and should be controlled in both the closed-loop and open-loop configurations. Radon emission is also dependent on the grain size of loose materials, and the porosity of any bulk material. In addition to radon, thoron can also be measured in the Bulk Emission Chamber. In the open loop mode, a correction is required for the decay of the thoron during the time between its emission and measurement in the RAD7. In closed loop mode, another correction must be made for the portion of thoron that gets fed back into the enclosure. Note that for thoron, both the closed loop and open loop modes are steady-state measurements. Fig. 4 Bulk Emission Chamber Uncovered Section 2 Bulk Emissions 7

3 SURFACE EMISSIONS DURRIDGE offers two surface emission chambers, one for solid hard surfaces, and another for soft soil surfaces. Each consists of a circular plate which is sealed against the surface under investigation. The Hard Surface Emission Chamber accomplishes this using a rope caulk seal, while the Soil Surface Emission Chamber uses a penetrating metal rim, as shown in Figures 5 and 6, below. The measurement procedure for the Surface Emission Chambers is similar to that of the Bulk Emission Chamber described above. Once the total emission rate within the chamber enclosure has been calculated, it may be divided by the area of the surface within the sealed boundary, to determine the emission per unit area. These areas are listed in Section 3, Technical Specifications, on the next page. Fig. 5 Hard Surface Emission Chamber Section 3 Surface Emissions Fig. 6 Soil Surface Emission Chamber 8

4 TECHNICAL SPECIFICATIONS 4.1 Bulk Emission Chamber Interior Dimensions Interior Volume Material Hose Connectors 4.2 Surface Emission Chamber Outer Dimensions Interior Cavity Dimensions Partition Dimensions Interior Cavity Volume Material Hose Connectors 11 x 7 x 2.5 (28 x 18 x 6.4 cm) 2.8L ± 0.05L depending on configuration Metal Front Mounted 10 (25.4 cm) diameter by 1.25 (3.2 cm) deep 8.5 (21.6 cm) diameter by 0.5 (1.27 cm) deep 7.9 (20 cm) long by 0.5 (1.27 cm) wide Approx. 26.4 cubic in (432.6 ml) Metal Top Mounted Section 4 Technical Specifications 9

DURRIDGE Company Inc. 524 Boston Road Billerica, MA 01821 Telephone: (978)-667-9556 Fax: (978)-667-9557 Web: www.durridge.com Email: service@durridge.com Copyright 2018 DURRIDGE Company Inc. All rights reserved. DURRIDGE, the DURRIDGE logo, and the Works with the DURRIDGE logo are trademarks of DURRIDGE Company Inc., registered in the U.S. Revision 2018-01-31 10