Temperature Controllers

Similar documents
Float Operated Level Controllers

HIGH PRESSURE REGULATOR PACKAGES

MEGR-1627 Instruction Manual

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

MEGR-1912 Instruction Manual

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

OPERATING AND MAINTENANCE MANUAL

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

64 Series Pressure Reducing Regulators

WW-730. Pressure Sustaining/Relief Control Valve

Fisher DVI Desuperheater Venturi Inline

Installation, Operation, and Maintenance Manual

WW-720. Pressure Reducing Control Valve

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

1805 Series Relief Valves

Types S100K and S102K Pressure Regulators

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Gas Fired Residential Heating Boilers

WW-720. Pressure Reducing Control Valve

1200B2 Series Service Regulators. Instruction Manual

Design DSA Steam-Atomized Desuperheater

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

MyControl Bathing System Signature Series

Pressure Regulators. Operating Instructions. Instrumentation

MAINTENANCE & ASSEMBLY INSTRUCTIONS FUSIBLE LINK. Inline Thermal Check Valve

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

RD(H)20/25 Pressure-Reducing Regulator User Manual

INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

1800C and 1800C-HC Series Service Regulators

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

G96 Series BASOTROL Dual Operator Valve

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

1305 Series Pressure Reducing Regulators

Type CT88 Backpressure Regulator

Regulator from 1800 B series

Installation Instructions

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

WHEATLEY Series 822/820 Swing Check Valve

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Fisher and Whisper Disk Diffusers

LRS(H)4 Pressure-Reducing Regulator User Manual

Bermad Pressure Reducing. Model: 42T

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

LOCK UP VALVES YT-400/405/430/435 SERIES

Interface Devices, Inc. Hydraulic Mini Mule

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

INSTALLATION & MAINTENANCE INSTRUCTION

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Operation Manual Piston Sensed Gas Pressure Regulators

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Types 95L and 95H Pressure Regulators

Fisher DSA Steam-Atomized Desuperheater

Types 749B and R130 Changeover Manifolds

Installation Instructions For Natural Gas Conversion

Model Secure-Gard Pilot Operated Vent Valve SECTION II. Remove all packing material inside and outside of the valve prior to installation.

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Eaton Filtration, LLC

G92 Series BASOTROL Automatic Pilot Gas Valve

DS05C,D,G Dial Set Pressure Regulating Valves

INSTRUCTIONS FOR MODEL TSC LOW DELIVERY PRESSURE GAS REGULATORS

INSTRUCTIONS FOR SINGLE STAGE LECTURE BOTTLE REGULATORS

Installation, Operation, and Maintenance Manual

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

CLASS D - SENSITIVE LEAK TEST GAS AND BUBBLE METHOD. 1.1 To provide definitive requirements for PNEUMATIC pressure testing of piping systems.

623 Series Dome Load Regulators

Model 420-HY Pressure Regulating Hydrant Valve

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

1301 Series High-Pressure Regulators

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

Propane Conversion Kit Instructions

SINGER MODEL 106/206-RPS-L&H

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

627 Series Pressure Reducing Regulators

2.0 INSTALLATION & SERVICE

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Models: C62/63/64-A/D

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

TECHNICAL DATA CAUTION

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

Operator: Save these instructions for future use!

Oxygen Usage Best Practice Guide

V DGX Series. Direct-Operated Regulators Manual D103834X012

USER S INFORMATION MANUAL

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Transcription:

IM0004 April 2013 CONTENTS T-12 Thermostat PAGE Introduction 1 Scope 1 Description 1 Specification 1 Temperature Controllers 2 INTRODUCTION CAUTION Prior to installing, the instructions provided herein should be completely reviewed and understood before operating or repairing this equipment. All CAUTION and notes must be strictly observed to prevent personal injury or equipment damage. Scope This installation manual includes instructions and maintenance information for the T-12, HT-12PG Kimray temperature controllers. Do not install, operate, or maintain a temperature controller without being fully trained and qualified with the Kimray installation and maintenance manual. To avoid personal injury or property damage, it is important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If you have any questions about these instructions, contact your Kimray applications support group before proceeding. Description The temperature controllers are designed to control set temperature in indirect heaters, emulsion treaters, reboilers, steam generators, heat exchangers cooler shutter controls, and salt bath heaters. The pilot guard is designed to monitor the pilot flame to a burner in case the flame is extinguished. A name tag is attached to the upper bonnet housing on each thermostat. The name tag lists the serial number, model number, and pressure rating. Specification Table 1 - General Specifications Valve Description: Normal Service: Connection Size: Body Style: Connection Type: Actuation: Temperature Range: Ductile Iron, Steel Liquid 1/2 NPT, 3/4 and 1 available with separable socket Angle NPT Direct or Indirect -30 F to 750 F -34 C to 399 C Pilot Guard CAUTION When ordered, the temperature controller configuration and construction materials were selected to meet specific pressure, temperature, pressure drop and fluid conditions. Since some body/trim material combinations are limited in their pressure drop and temperature ranges, do not subject the temperature controller to any other conditions without first contacting the Kimray Inc, sales office or a sales / applications representative. Do not exceed the maximum supply pressure specified on the controller nameplate. Under no circumstances should the controllers supply pressure ever exceed the maximum range. Before beginning the installation of the temperature controller: Read and follow instructions. Follow all safety warnings of the switch manufacturer. Make sure the controller cannot operate during installation. Observe all pressure, ratings and requirements for the devices and the operating environment. Make sure all pressure has been removed from the vessel before opening any connec tions. Kimray Inc.- 52 NW 42nd Street Oklahoma City, Ok 73118 USA - Ph: (405) 525-6601, Fax: (405) 525-7520 - Kimray.com 1

Installation Before installing the temperature controller, inspect it for shipment damage and for foreign material that may have collected during shipment. Before starting the installation of a burner control system, it is important to understand what the equipment is for and why it will be installed. Figure 1 shows a typical temperature controller installation. Note If one component in the loop fails then the entire system is shut down. 1. Supply Gas - is required to operate the pilots and valves in the system. At any time, interrupting the flow of supply gas will shut the entire system down. 2. Pilot Guard - Everything starts with monitoring the pilot flame. Supply gas to the entire system must run through the pilot guard. If the pilot guard detects the flame, it will allow supply gas to pass to the T-12M. If the flame goes out, the pilot will block supply gas to the entire system and shut it down. Figure 1 3. T-12M - Monitors the high temperature set point of the system. When the tem perature of the system is in operating range, supply gas is allowed to pass through to the T-12 and the first presure open valve. If the temperature climbs above set point of T-12-M, it will stop supply gas to the T-12 and also to the first valve on the burner main line, causing the entire system to shut down. 4. T-12 - When the system is within operat ing range, the T-12 will have supply gas to operate from the T-12, then the T-12 will throttle the valve that controls the burner flame to maintain a constant temperature. Temperature controllers and other devices should be installed, and maintained in accordance with international codes and regulations, manufacturer s instructions, and proven best practices. Personal injury, equipment damage, property damage, leakage, or bursting of pressurecontaining parts may result if the valve is overpressured or installed where service conditions could exceed the limits given in the general specification section. Overpressure protection should also be provided if the valve inlet pressure may exceed the safe working pressure of the equipment downstream. To avoid injury or damage, install pressurerelieving or pressure limiting devices to prevent service conditions from exceeding those limits. Consult the appropriate code, regulations, or standards. Consideration should be given to the potential risk of injury or property damage due to escaping fluid. To avoid such risks, install the regulator in a safe location. 2

Separable Socket: 1. Inspect the openings in the vessel for foreign material and clean the connection ports to remove scale, chips, and debris. 2. Kimray always recommends installing thermostats with separable socket using good piping practice. Be sure to use TFE tape or pipe thread sealant on external pipe threads. 3. Make sure that separable socket is completely submerged in liquid or flow stream. Partial submersion will give eratic temperature transfer to thermostat. 4. Pack separable socket full with high temp bearing grease. This helps in heat transfer and prevents air space. If hazardous or flammable gas are used for instrument gas, and the pilot is in an enclosed area, personal injury or property damage could result from accumulated gas being released through the vent. To avoid potential risk provide adequate ventilation or pipe away vented gas. Before any service, be sure that the thermostat is fully isolated and that all pressure upstream and downstream has been relieved. Use bypass valves or fully shut off the process. When handling fire alway be aware of your companies fire safety rules and understand the start-up procedures. Temperature Controllers Thermostat: 1. Remove all plastic from the 1/4 NPT opening. 1/4 NPT opening, 1/4 tubing (not provided) must be installed. 2. Install thermostat into separable socket (recommended) being sure to use proper piping practices. Be sure to use TFE tape or pipe thread sealant on external pipe threads. 3. Install tubing from source of instrument gas, designated instrument supply. 4. Install tubing to the diaphragm housing of the control valve being operated. Pilot Guard: 1. Remove all plastic from the 1/4 NPT opening. 1/4 NPT opening, 1/4 tubing (not provided) must be installed. Output Instrument Supply Figure 2 Note Never assume that a check valve is fully blocking the downstream line. While there is pressure on the line, never tighten any fitting or the main connections to the thermostat. 2. Install pilot guard into the proper opening so that the tip of the sense rod will be in the pilot flame. Be sure to use TFE tape or pipe thread sealant on external pipe threads. 3. Install tubing from source of instrument gas, designated instrument supply. 4. Install tubing to the diaphragm housing of the control valve being operated or when applicable the next controller, designated output. Instrument Supply Output Figure 3 3

Start-up and Test Temperature Controllers 1. Open the bypass valve around the safety valve. If the bypass valve is omitted, proceed to step 2. 2. Adjust the pilot guard for an output guage pressure reading of approximately 50% of the supply pressure. (Counterclockwise to increase pressure and clockwise to decrease pressure). 3. Light the pilot according to the standard procedures taking all the necessary safety precautions. 4. Watch the output gauge. As the temperature increases, the pressure on the output gauge will rise upward. As this occurs, readjust the pilot guard control knob to maintain an output pressure of approximate 50% of the supply pressure. (Adjust the knob clockwise to decrease the output pressure). 5. Continue the process in step 4 until little change in the pressure reading on the output gauge is observed. (This time interval could be 15--20 minutes or longer). This process adjusts the pilot guard to the maximum pilot flame temperature and insures a rapid system shutdown if the pilot flame goes out. 6. When the output pressure stabilizes, the control knob can be turned counterclockwise for the 100% output pressured,the output pressure guard is now set. Close the bypass valve. 7. The burner system should now be cycled. Occasionally, drafting occurs during the burner cycle and cools down the pilot guard enough for shutdown. If this occurs, turn the control knob counterclockwise approximately 1/8 of a turn, until drafting will not cause a system shutdown. 8. Should the system ever shutdown, it is necessary to determine what caused the shutdown. If a cooling effect, due to drafting, occurred re-adjust the control knob counterclockwise approximately 1/8 of a turn at a time, until drafting will not cause a system shutdown. 9. To restart after shutdown, open the bypass valve and light the pilot. When the output pressure of the pilot guard reaches 100% of the supply pressure, the system is operating and the bypass valve must be closed. If the bypass valve has been omitted, repeat steps 2-8. 10. Once the pilot guard is stable, proceed to the T-12M. The next steps require that a temperature gauge be installed in the system. 11. On the T-12M and T-12 turn the control knobs clockwise until they stop. On the T-12M turn control knob counterclockwise to desired shut down temperature. (Turning more than 1 1/4 revolutions will take the thermostat out of calibration). 12. Making sure the T-12 is set to a higher temperature than the T-12M, push up on the reset lever of the T-12M. At this time the burner valves should open and ignite the burner flame. 13. Monitor burner temperature until it reaches your required safety shut off temperature. Turn T-12M control knob counterclockwise until output pressure to T-12 and first control valve stops. This will be your shut off temperature. Turn T-12M control knob counterclockwise until output pressure to T-12 and first control valve stops. This will be your shut off temperature, make sure the temperature on your temperature gauge matches the temperature indicator on the T-12M. 14. At this time all valves should be closed and the entire system shut down. The system will need to cool below T-12M set point before setting the T-12 thermostat. 15. Once the system has cooled down, pilot light start up procedure has been repeated and burner flame is lighted. The T-12 thermostat can be set. 16. The T-12 thermostat will control the main burner valve and maintain a constant temperature in the vessel. Once the burner flame is active, the temperature can be increased by turning the control knob clockwise to increase temperature or counterclockwise to decrease tempera ture. (Turning T-12 thermostat more than 1 1/4 turn counterclockwise will take it out of calibration). Maintenance Maintenance should be performed on a regular basis. An initial inspection interval of 6 months is recommended. Depending on the service conditions of the valve, the inspection interval may be decreased or increased. If the thermostat leaks fluid, it indicates that service is required. Failure to take the thermostat out of service immediately may create a hazardous condition. Erratic temperature changes Continuous venting Trouble Shooting Problem Possible Cause(s) Possible Solution Bent sensing element (The element should be centered in base and should ring ). Incomplete immersion of probe. Oversized burner valve. Dirty pilot plug seat. Hole in diaphragm. Weak pilot plug spring. Faulty O-ring. Replace sensing element if badly bent. Make the correct adjustments for stability. Clean pilot seat and re-use. Replace diaphragm. Replace spring. Replace o-ring. 4

Related Publications: See Product Bulletin - PB0015 See Catalog Page - H:i Kimray is an ISO 9001- certified manufacturer. Kimray quality assurance process maintains strict controls of materials and the certification of parts used in Kimray temperature controllers. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed as warranties for guarantees, express or implied, regarding Kimray products or services described herein or their use or application. All sales are governed by our terms and conditions, which are available on request. Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice. 5