BRAZE-FREE INTRODUCING PARKER CONNECTORS. Installs up to 77% faster than brazing in independent testing

Similar documents
PLUMBING, FIRE SAFETY, AND RADIANT HEATING AND COOLING SYSTEMS INSTRUCTIONAL GUIDE. Making ProPEX Connections

>B< Press Range. SALES: +44 (0) FAX: +44 (0) WEB:

>B< Press Range. SALES: +44 (0) FAX: +44 (0) WEB:

>B< Press Range. SALES: +44 (0) FAX: +44 (0) WEB:

>B< Press Range. SALES: +44 (0) FAX: +44 (0) WEB:

POWER FLUSH KIT INSTRUCTIONS

>B< Press Range. SALES: +44 (0) FAX: +44 (0) WEB:

Aeroquip Fluid Conveyance

PDY TON HYDRAULIC CRIMPING TOOL WARNING

MATERIALS FOR PLUMBING SYSTEMS FITTING AND INSTALLATION GUIDE

FIRESTORM. Assembly Instructions. Electric Upgrade Kit for the Autococker. Designed & Manufactured by PGI

Push-Lok 801/804/821/836 Hose and Fittings

MyControl Bathing System Signature Series

TRAINING TASK 1- for regional heat skill competition

Installation Instructions for NP100 Series Nitrogen Control Panels

REFER TO AQUATHERM TECHNICAL BULLETIN A-AQTTB FOR ADDITIONAL INFORMATION AND SAFETY PRECAUTIONS

Eliminating Medical Gas Shutdowns for 10 years

35 TON HYDRAULIC PUNCH WARNING

tubepress press procedure

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Press-fit Joining System for Copper Tube

Four common PRESSURE CALIBRATION PAIN POINTS

Beverage Systems. Component Inspection and Service TSB-Y Date: Subject: Products Affected: Description: July Inspection of CO 2

AIR STAPLER MODEL: CSG1C Part No

GENERAL DESCRIPTION MODEL RCW DRY SYSTEM CONFIGURATION. Technical Support Airpark Dr. Standish, MI 48658

PANACEA P100 LOW PRESSURE USER MANUAL

DISASSEMBLING & REASSEMBLING CARTRIDGE INSTALLING SEATPOST ON BIKE

INTRODUCTION BILL OF MATERIALS SPECIFICATIONS & TOOLS PROCEDURES OPERATION OF SEATPOST GIANT LIMITED WARRANTY

UsER manual for Watersens ph -REDOX

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

TANK MATE INCLUDES: TOOLS REQUIRED: CONRADER VALVES 3/4 WRENCH **TUBING CUTTERS TEE PETCOCK TEE ASSEMBLY 8 FOOT NYLON TUBING

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

NGP-250/500 Nitrogen Generator Quick Start Guide

COMPRESSION TUBE FITTINGS

REL-510H WARNING NOTICE 12 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD

Forged Brass Bellows Valves

Field Manual. Simple by Design

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Installation, Operation, and Maintenance Manual. Welker Constant Pressure Cylinder With Solid Indicator (Non-mixer) Model CP-30SI

Part # Balanced SCUBA Regulator Assembly for M-48 SuperMask and MOD-1 Installation Guide

TECHNICAL INFORMATION

VERSION 1.2 R-TRACK USER GUIDE. ZiPPERTUBiNG CO. THE. (480)

Brazing. Turn up the. When brazing and soldering, most HVACR technicians

COMPRESSION TUBE FITTINGS 1/16 THROUGH 2 -INCH, 2 MM THROUGH 50 MM-METRIC

Nitrous Oxide / Oxygen FLOOR MOUNTED OUTLET STATION Installation and Instructions

USER MANUAL LGS / LGS Bedford Hwy, Suite 100, Halifax NS, Canada B3M 2L loraxsystems.com

// ADapters GUIDelines

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

REL-46 WARNING NOTICE 15 TON SINGLE ACTING REMOTE HYDRAULIC CRIMPING HEAD. Compatible with RELIABLE R15 and P Style dies. REL-46 Manual

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Plasson Pressure Reducers & Pressure Regulators

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

TECHNICAL DATA. Q = C v P S

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

INSERT FITTINGS INSERT FITTINGS

Pneumatic Oil Extractor

Safety, Operating and Maintenance Manual. TRAIN Rat DS9-TRAIN

Installation Manual. BC Box Modification with Port Isolation

Shut-Off Valves and Valve Boxes

EXOTHERMIC TORCH ADAPTER. Instruction Manual

6890 GC Site Preparation

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

TECHNICAL DATA. Q = C v P S

Glove Box Installation Manual

TECHNICAL DATA. Q = C v P S

6. Features & Benefits Installation Considerations Jointing Instructions Pipe Sizing Calculations & Tables

A hose layline contains important information for specifying the replacement assembly: manufacturer, hose trade name, working pressure and hose ID.

NITROGEN PURGING SYSTEMS FOR THE HVAC INDUSTRY VISION INNOVATION SOLUTION

G7S Hand Pump Owner s Manual

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

COMPRESSOR MANUAL. (888)

TECHNICAL DATA OBSOLETE

Medical Gas Solutions

INSTALLATION GUIDELINES

Technical Operating Instructions for Magnum Cutting Systems. for online instructions

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

INSTALLATION GUIDELINES

Technical Specification

TactAir PCP Fill Kit/Adapter. Operation Manual

SPUD OWNER S MANUAL ALWAYS WEAR A COAST GUARD APPROVED FLOTATION DEVICE WHEN OPERATING THE SPUD KAYAK.

Technical Service Bulletin May 2017 TSB

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

AUTOVENT 4000 VENTILATOR

CROT-6 CROT-10 CRO-4. for Compressor Overload Protection

PVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION

May08 Rev B

Macro-Infusion Guide

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

36% higher capacity than market alternatives. New ICF 50-4 and ICF 65-3: A great valve family just got greater.

AQUARIUS. Operating Instructions for the. Type 70 Electrolytic Gas Soldering / Welding Unit. Table of Contents

ROPV R40 E Series User Manual

TECHNICAL DATA. Q = C v P S

P R O D U C T G U I D E

COMPRESSION TUBE FITTINGS

Hot Compressed Air Lance Operation Manual. LAB Manufacturing 9483 Reading Road Cincinnati, OH (800)

Viega ProPress System

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Transcription:

INTRODUCING PARKER BRAZE-FREE CONNECTORS Installs up to 77% faster than brazing in independent testing Time savings Reduced labor Less material Less equipment No special skills No special permits Increased safety Increased productivity Increased flexibility More profit potential

NEW PARKER BRAZE-FREE TUBE CONNECTORS CHANGE EVERYTHING. ESPECIALLY YOUR WORK SCHEDULE. Connecting copper tubes just got a whole lot easier and more efficient for HVAC/R technicians, thanks to the unique Braze-Free connectors concept from Parker. New Parker connectors are specially designed to work without brazing, which automatically makes your job simpler and faster when joining copper tubes. In addition, the one-piece fittings are reliably secure, leak-proof and more repeatable than brazed connections so there s no compromise on quality or performance. Professionals who have tried Braze-Free couplings report that their time and labor costs on tube connections are typically reduced 40 50% by eliminating the need for brazing. The biggest benefit of that improved efficiency is more productivity and increased profit potential, but there are also many other exciting advantages to braze-free tube connecting: Less equipment and no gas needed Safer conditions, no fire hazards No hot work permits required More environment-friendly No solder-related quality issues More flexible access to job sites No need to nitrogen-purge

NO SPECIAL TECHNIQUES, JUST SPECIAL ADVANTAGES. Parker Braze-Free fittings connect so easily, one person can do the connecting job alone. You don t need anybody else to help you haul gas tanks or stand by with fire safety equipment. Braze-Free tube connecting is also more repeatable than brazing. Any technician can quickly be an expert at tube joining with Braze-Free fittings. They will be able to do it without a lot of set-up, safety precautions or clean-up. BRAZING vs. BRAZE-FREE CONNECTORS TIME-CONSUMING. RISKY. DIRTY. IMPERFECT. Torch kit with gas regulators Gas tanks (2) Tube cutter De-burring tool Degreaser Scotch-Brite TM Cooling rag Access to water Solder and flux Fire extinguisher Fire safety equipment Burn permit Fire spotter QUICK. EASY. CLEAN. REPEATABLE. Crimping set Tube cutter De-burring tool Scotch-Brite TM Rag

PARKER BRAZE-FREE CONNECTORS Installation Complexity (tools, prep) Application Parameters Temperature Range Application Parameters Max Op. (psi) Application Parameters Max Burst Pressure (psi) Application Parameters Size availability Application Approved Refrigerants Low -25 F to 300ºF (-32 C to 148.9ºC) 700 3000 1 /4 1 1 /8 High Pressure HVAC/R R410A, R134a, R404A, R407A/C/F, R507, R32 A BRILLIANT IDEA. A SIMPLE SOLUTION. The Braze-Free connecting process is based on exclusive, patented crimping technology. You only need two hands and a few simple tools. No brazing, no experience... and practically no time at all. Using specially designed crimping tools, just connect the deburred tube ends into the fitting (which has o-rings inside), and press the assembly into place for a secure, leak-free seal. Another advantage of the Braze-Free process is that if the press fitting is not crimped properly, it can be easily re-crimped. In addition, it requires no adhesives, just the crimping tool and the fitting. Parker Braze-Free connectors are currently available as a traditional straight coupling and a 90-degree elbow, with a T connector coming soon. The fittings can accommodate copper tubes from 1 /4 to 1 1 /8 with maximum operating pressure of 700 psi.

HOW BRAZE-FREE FITTINGS WORK. As these brief descriptions show, it s easy to install Braze-Free fittings for a clean, secure fit, but be sure to read and follow all of the detailed instructions, which come with the product. WARNING: Use only exclusive Parker Braze-Free fittings and products. Please read the instruction manual in complete detail prior to installation. Assure that all the proper tools 1 (the fitting, the crimping jaws, etc.) and aids are available prior to installation. Visually inspect the fitting, tube 2 and o-rings for imperfections, and replace if necessary. Cut the copper tube using the 3 supplied tube cutter. The Crimp Gauge can ensure the tube end is perpendicular. Use the deburring tool to remove 4 any residual burrs from the outside and inside of the tube (sharp edges may damage the o-ring). Using the dimple as a reference point 5 for the center of the fitting, mark the tubing with a permanent marker to indicate proper insertion depth on every tube. Push the fitting onto the tube. 6 A reference dimple in the fitting helps assure insertion depth and secure fit. Using the properly calibrated jaw, 7 place the crimping tool onto the fitting. Grooves in the jaws should line up on the fitting. Press and hold the trigger on the 8 tool until it completes its cycle. A special mark will be displayed on the tube to let you know the connection is right. It s that easy. HOW EFFICIENT TECHNICIANS CONNECT. The one-of-a-kind Parker Braze-Free connector is truly a game-changer for air conditioning/refrigeration contractors looking to be more efficient. It works for residential as well as commercial/industrial applications. Talk to your local authorized wholesaler or distributor about new Parker Braze-Free connectors, or call 636-239-1111.

2015 Parker Hannifin Corporation. Form P-432 / 012015 Parker Hannifin Corporation Sporlan Division 206 Lange Drive Washington, MO 63090 USA phone 636 239 1111 fax 636 239 9130 www.parker.com/coolparts