Automatic Transport Ventilators. ICU Quality Ventilation on the Street.

Similar documents
O-Two Self-Study Guide. e600 Transport Ventilator Ventilation Modes

Selecting the Ventilator and the Mode. Chapter 6

PERFORMANCE EVALUATION #34 NAME: 7200 Ventilator Set Up DATE: INSTRUCTOR:

Oxylog 3000 plus Emergency & Transport Ventilation

MEDICAL EQUIPMENT IV MECHANICAL VENTILATORS. Prof. Yasser Mostafa Kadah

Technical Data and Specifications

Ventilators. Dr Simon Walton Consultant Anaesthetist Eastbourne DGH KSS Basic Science Course

Mechanical Ventilation. Mechanical Ventilation is a Drug!!! is a drug. MV: Indications for use. MV as a Drug: Outline. MV: Indications for use

GE Healthcare. Centiva/5 Critical Care Ventilator. Meet a new level of expectations

Understanding and comparing modes of ventilation

INTENSIVE CARE VENTILATORS

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

Dräger Savina Sub-Acute Care Ventilation

Inspiration 7i Ventilator

Hospital and Transport for Controlled Breathing

AUTOVENT 4000 VENTILATOR

How Ventilators Work. Chapter 3

Automatic Transport Ventilator

Panther 5 Acute Care Ventilator

Health Professional Info

VENTILATION SERVO-i INSPIRATION IN EVERY BREATH

Airox Supportair Ventilator

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

Solutions. Digital pressure management solutions. Copyright 2013 GaleMed Corporation

Operation of Oxylog 3000 ventilator

HAMILTON-C2 HAMILTON-C2. The universal ventilation solution

SLE5000 Infant Ventilator with HFO

Ventilator Training Module

Oxylog 2000 plus. Step up your performance. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

Using Common Ventilator Graphics to Provide Optimal Ventilation

Update to RS-232 commands. Changing patient from NIV to INVASIVE Vent Type. SNDF command

Manual: Biphasic Positive Airway Pressure (BiPAP) Ventilation

WILAmed INTENSA. Intensive Care Ventilator System

DATA SHEET. VENTILATION SERVO-s

Emergency Transport and Ventilation

Advanced Ventilator Modes. Shekhar T. Venkataraman M.D. Professor Critical Care Medicine and Pediatrics University of Pittsburgh School of Medicine

Virginia Beach EMS. Oxylator EMX. Debra H. Brennaman, RN, MPA, NREMT-P

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

Meet the changing needs of your patients. Trilogy Series, with advanced ventilator technology

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

Flight Medical presents the F60

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

e700 Automatic Transport Ventilator User Manual e700 User Manual (15PL Rev.14 28_8_2017)

Milestones of Aeonmed Ventilators

Peter Kremeier, Christian Woll. 2nd. Understanding and comparing modes of ventilation. The Kronberg List of Ventilation Modes

V8600 Ventilator. Integrated Invasive & Noninvasive Ventilation

Oxylog Better to have one. Because you care. Emergency Care Perioperative Care Critical Care Perinatal Care Home Care

A9600 Anesthesia Workstation. Your healthcare, we care.

Complex Care Hub Manual: Pressure Ventilation on the LTV 1200

Mechanical Ventilation

Guide to Understand Mechanical Ventilation Waveforms

fabian HFO: Modular, Powerful, Versatile.

Minimum size for maximum performance

MT Excellent performance and reliability EVITA 4 EDITION

Dräger Savina 300 Select ICU Ventilation and Respiratory Monitoring

evolution 3e Ventilators

Transport Ventilators

SLE5000 Neonatal Ventilator with High Frequency Oscillation

Dräger Oxylog 3000 plus Emergency & Transport Ventilation

IEC C LASSIFICATIONS:

Medical Instruments in the Developing World

An intuitive and innovative answer to your anaesthesia challenges

Operating Instructions for Microprocessor Controlled Ventilators

Puritan Bennett 840 Universal Ventilator

HAMILTON-C3 HAMILTON-C3. The compact high-end ventilator

D Beyond essentials DRÄGER SAVINA 300 SELECT

Test your PICU/ NICU/ CHSU Knowledge

fabian HFO Our 4-in-1 device

A bench study comparison of volume delivery in the presence of leak

SATURN EVO COLOR A N A E S T H E S I A S Y S T E M. Manufacturer of high quality anaesthesia products

Evita 2 dura. High-end ventilation in your patient s best interests. Because you care

Draeger Fabius GS Pre-Use Check

Neonatal Ventilators. Touch-screen Neonatal Ventilator with High Frequency Oscillation SLE5000

VENTIlogic LS VENTIlogic plus. 100 % Mobility and Reliability in IV and NIV

D Beyond essentials DRÄGER SAVINA 300 SELECT

Mechanical ventilation: simplifying the. terminology. Rapidly changing technology has unfortunately resulted in ambiguity in the terminology

SLE4000. Infant Ventilator with touch-screen operation. When the smallest thing matters

6 th Accredited Advanced Mechanical Ventilation Course for Anesthesiologists. Course Test Results for the accreditation of the acquired knowledge

Mechanical Ventilation

Indications for Mechanical Ventilation. Mechanical Ventilation. Indications for Mechanical Ventilation. Modes. Modes: Volume cycled

NEONATAL/INFANT VENTILATOR

GE Healthcare. Aestiva/5. More than superior ventilation

C O R P O R AT E B R O C H U R E

Unit 15 Manual Resuscitators

Intensa GO Alternate Care Ventilator

Classification of Mechanical Ventilators

Evita 2 dura. First-class ventilation in your patient s best interests. Because you care. Emergency Care OR/Anesthesia Critical Care Home Care

Dräger Savina 300 Classic ICU Ventilation and Respiratory Monitoring

Operator s Manual Addendum

UNDERSTANDING NEONATAL WAVEFORM GRAPHICS. Brandon Kuehne, MBA, RRT-NPS, RPFT Director- Neonatal Respiratory Services

Anesthesia Workstation

Expanding versatility. The upgraded Trilogy family of ventilators continues to meet the changing needs of your patients

Operation and Maintenance of the EPV200 Portable Ventilator

Completed downloadable Test Bank for Pilbeams Mechanical Ventilation Physiological and Clinical Applications 5th Edition by Cairo

2 PRE USE FUNCTION CHECK 3 OPERATING PROCEDURE 4 SERVICING. 5 CAREvent ALS ACCESSORIES 11

Introducing Astral. Greater freedom. Confident care. Designed efficiency

The centerpiece of a comprehensive anaesthesia workstation

A few seconds after turning on, the screen changes to Set Up Screen Before adjusting the pressure, calibrate the O 2 sensors

New Frontiers in Anesthesia Ventilation. Brent Dunworth, MSN, CRNA. Anesthesia Ventilation. New Frontiers in. The amount of gas delivered can be

Transcription:

Automatic Transport Ventilators ICU Quality Ventilation on the Street. Kevin Bowden, March 20 th 2014

Ventilator Definition A ventilator is an automatic mechanical device designed to provide all or part of the work the body must produce to move gas into and out of the lungs.

Since the early 70 s transport ventilators and automatic resuscitators have been a part of the pre-hospital environment arsenal

As ventilation techniques and patient treatments improved, so did the quality and capabilities of the available ventilators on the market

To facilitate simplicity in emergency situations small, hand held ventilators were developed to replace the manual resuscitator or BVM.

However, ventilation techniques and modes continued to improve, requiring more and more sophisticated ventilators to meet the ever-changing perspective of pulmonary physiology

Today s ATVs are sophisticated, can sometimes be complex to set up, yet provide ventilation quality that to a great extent mimic ICU ventilator performance

Requirements of Automatic Ventilators Automatic ventilators require: 1) A stable attachment (interface) of the device to the patient, 2) A source of energy to drive the device, 3) A control system to make it perform appropriately, and 4) A means of monitoring the performance of the device and the condition of the patient.

Positive Pressure Ventilators: 1) Patient Interface. The ventilator delivers gas to the patient through a set of flexible tubes called a patient circuit. Depending on the design of the ventilator, this circuit can have one, two or more tubes. The circuit connects the ventilator to either an endotracheal or tracheostomy tube that extends into the patient's throat - Invasive ventilation or a mask covering the mouth and nose or just the nose - Noninvasive ventilation. Each of these connections to the patient may have a balloon cuff associated with it to provide a seal - either inside the trachea for the tracheal tubes or around the mouth and nose for the masks.

2) Power Sources. Positive Pressure Ventilators There are two alternate power sources for positive pressure ventilators: Electricity This is used to run compressors of various types or Compressed gas - From either cylinders or built-in gas supply systems

3) Control System. This assures that the breathing pattern produced by the ventilator is the one intended by the patient's caregiver. It requires the setting of control parameters: the size of the breath, respiratory rate, inspiratory to expiratory ratio, gas flow rate, peak airway pressure inspiratory effort to trigger the ventilator

Breath Types: If the patient can control the timing and size of the breath, it is called a spontaneous breath. If the ventilator has total control over the breathing pattern it is called a mandatory breath.

A particular pattern of spontaneous and mandatory breaths is referred to as a mode of ventilation. Numerous modes, with a variety of names, have been developed to make ventilators produce breathing patterns that coordinate the machine's activity with the needs of the patient;

Ventilator modes: ACV, SIMV, PCV, CMV, PSV, IPPV, BiLVL, BiPAP, CPAP Many of these modes have both volume and pressure cycling capabilities

4) Monitors All modern ventilators have at least a pressure monitor measuring airway pressure. Many modern ventilators have sophisticated pressure, volume and flow sensors that produce signals both to control the ventilator's output (via feedback in the ventilator's control system) and to provide displays (with alarms).

A new range of electro-pneumatic ventilators offering significant advantages over currently available products of this type. Half the weight of competitive devices Smaller footprint Up to 5 X longer battery operating time than other equivalent products Additional ventilation modes not found on other ventilators Zero drive gas consumption