Thermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.

Similar documents
DTG - LCD Digital Temperature Gauge USER MANUAL

CDS-2000 CO 2 Sensor Verification, Calibration, and Troubleshooting Bulletin

Instruction Manual for Intrinsically Safe - Reed Switches

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

High-performance submersible pressure transmitter For level measurement Model LH-10

1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS

OxyCheq Expedition-X Oxygen Analyzer. Operator s Manual

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

Calibration Requirements for Direct Reading Confined Space Gas Detectors

How to specify a product. Process Sensors and Mechanical Instruments

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

API MPMS Chapter 17.6 Guidelines for Determining the Fullness of Pipelines between Vessels and Shore Tanks

Intrinsically Safe Acoustic Instrument Used in Troubleshooting Gas Lift Wells

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

High-performance submersible pressure transmitter For level measurement Model LH-10

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

Columbus Instruments

780S Ultra High Purity Series

TC65M/15M TEMPERATURE CALIBRATOR USER S MANUAL

Hand-held pressure calibrator with integrated pump Model CPH6600

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Pressure switch KP-E. Data sheet

Heavy Duty Dissolved Oxygen Meter

I/P Transducer Positioner Module

Oxford. Manufacturer s Contact Details. Contents. Oxford Low Profile Weigh Scale. English

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

DPC-30 DPC-100. Reference Manual

Technical Data Sheet MF010-O-LC

Calculating Total Uncertainty of Temperature Calibration with a Dry Block. Calibration White Paper. Beamex.

How to calibrate the formaldehyde sensor within a PPMonitor Wireless Unit:

PM105 PRESSURE METER USER S MANUAL

Gas density monitor With integrated transmitter Model GDM-100-TI

Installation, Operation, & Maintenance Manual. MODEL: Watlow Controller P53 Direct, P53 Remote

Advanced Test Equipment Rentals ATEC (2832)

Model 130M Pneumatic Controller

9700 Transmitter Submersible hydrostatic level transmitter

BAPI Pressure Line of Products - FAQs

GEMS SENSORS & CONTROLS

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents

EC214 EC215 - EC215R Bench Conductivity Meters

Temperature gauge Installation Guide

Installation Instructions

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

User s Guide Temperature Sensor Converter TSC-599

Wireless I/O, Connecting Remote Sensors in a Wide Range of Environments

Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels

Model Description

FLAMMABLE GAS SENSOR/TRANSMITTER

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters

North American Pressure Switches

This test shall be carried out on all vehicles equipped with open type traction batteries.

TECHNICAL NOTE. October 23, Procedures for Verifying Temperature Calibration

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

Installation and Operation Manual

5 Function Indicator. Outside Air Temperature (C) Outside Air Temperature (F) Pressure Altitude Density Altitude Aircraft Voltage STD TEMP SL 15000

The American Society for Nondestructive Testing

High-performance submersible pressure transmitter For level measurement Model LH-20

GAS ANALYSER OXYBABY M+ for O 2. or O 2 /CO 2. standard version

SITRANS P measuring instruments for pressure

Certificate of Compliance

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Instruction Manual HI Portable Waterproof Dissolved Oxygen Meter.

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Optical Dissolved Oxygen Meter

_ pressure transducers. User Manual

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

RTD temperature probes

HI 2314 HI 2315 HI 23151

User Manual. GPL 3000 e. gas detector

Optical Dissolved Oxygen Meter

S-D2 OPERATOR S MANUAL Lev A

Installation Instructions

Installation Instructions

BGA158 Series CE Approved Class A Shutoff Gas Valve

200A Series ELECTRONIC LEVEL TRANSMITTER

RULES PUBLICATION NO. 119/P

Oxidation Stability of Gasoline and Aviation Fuels

DFX II Series. Digital Force Gauge

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

White Paper August , Rev AA

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Calibration and Bump Test Requirements for Direct Reading Portable Gas Monitors

GENERAL APPLICATION NOTES

INSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter

ellison sensors international

Series 6517 Katharometers. The ideal equipment for Process Monitoring and Control. Robust no moving parts. Designed for continuous industrial use

BGA244 Binary Gas Analyzer

Type Testing Procedure for Crankcase Explosion Relief Valves

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

APG. Intrinsically Safe, Heavy Duty Pressure Transducer Series: PT-400

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

THERMAL MASS FLOW MEASUREMENT FOR GASES

Transcription:

Display Thermo, Inc. Instruction Manual English TP-5 Display TP-7 Display TP-8 1-1

Thermo, Inc. Instructions for use- Models TP-5, TP-7, and TP-8 The manual describes basic function and use of Thermo instruments and basic safety instructions. The Thermo Portable Electronic Thermometer is a portable digital temperature instrument. Intended use of Thermo is both in hazardous (flammable) and non-hazardous areas. Typical areas for use: a) Tankfarms or tanks containing oil or chemical products. b) Refineries, chemical plants, hot-water producing plants, etc. c) Marine transportations such as; tankers, barges or other transport facilities. d) Food processing plants. e) Other industrial plants where temperature measuring is needed. FUNCTION Thermo case enclosures are built upon knowledge from previous models and constructed to withstand the rigors of field use. Measuring cable is made with a Teflon FEP or PFA outer layer with carbon blended to reduce static charge. DuPont Kevlar reinforcement is included in cables for select models in order to resist cuts. Cable and sensor probe storage is integral with the case. Electronic circuits are placed inside the case, well protected. To reach the electronic circuits and battery, the faceplate, side-plates, or battery cover must be removed depending on model. Measured temperature is displayed via Liquid Crystal Display (LCD) visible through a window on the case. Electronic is CMOS technology, and powered by one non-rechargeable 9 volt battery. Cable is connected at one end to electronic circuits and to the probe containing a solid-state type chip or Platinum Resistive Temperature Device (RTD) on TP-7 and TP-8. Depress the sealed ON button on the case to read measured temperature on the display. For use in hazardous areas a grounding cable is included with the instrument. Also a carrying strap is enclosed for easy carrying. USE OF INSTRUMENT As Thermos are intended to be used in hazardous locations, user must have a working knowledge of appropriate safety instructions. SEE MARKINGS ON INSTRUMENT AND READ FOLLOWING INSTRUCTIONS PROCEDURES BEFORE USE a) The inspector must have a thorough knowledge of the products to be measured and must know of the safety measures to be taken when working with the material to be measured. b) Instrument shall be checked concerning severe defects; check that instrument is complete (including grounding cable), has good batteries, etc. If necessary, check measurement accuracy. If any defects are found, the instrument should not be used until repairs have been made. c) Instrument, especially cable and probe, should be clean both for safety reasons and ease of use. d) Estimation should be carried out to validate if physical place for measuring is considered a primary or secondary, or both, risk source. MEASURING PROCEDURES a) Check wind direction or other air-movements at place for measuring to avoid inhaling vapors. b) Attach grounding cable/bonding cable to bare metal grounding facilities associated with the vessel. c) Lower cable and probe into intended product at desired depth. 1-2

d) Press the ON button. Raise and lower the sensor about 1 foot in each direction to decrease the time for temperature stabilization. TP-7 and TP-8 units will turn off automatically after 1 minute, to save battery charge (Press OFF button on model TP-5). e) Wipe the cable and probe clean while winding up so that it will be clean for the next use. f) Remove grounding cable from grounding facilities and wrap around instrument to store. STANDARDS SIGNIFICATION Thermo petroleum gauging instruments are classified as intrinsically safe to North American, European and Japanese standards. Depending on the particular instrument and regional requirements, certifications are provided by the following testing laboratories: UL (US), KEMA (Denmark), NEMKO (Norway) and TIIS (Japan). Please check instrument identification plates for necessary designation. Safety Classifications: North America: Class 1, Division I, Groups CD - Model TP-5 North America: Class 1, Division I, Groups ABCD - Model TP-7,8 Europe: EExia IIB T3 Model TP-5 Europe EExia IIB T3/T4/T6 Model TP-7,8 Japan: EExia IIB T4 Model TP-7,8 Applicable Standards are: UL 913 Intrinsic Safety CSA 22.2 Intrinsic Safety CENELEC EN50014 Intrinsic Safety CENELEC EN50020 Intrinsic Safety CENELEC EN50081 EMC Emissions CENELEC EN55022 EMC Immunity Japan uses CENELEC Standards Agency or Safety Designation US: UL Canada: ULc Europe: Ex Europe: Ex Europe: CE Europe: CE Japan: Only Text Designation STANDARDS SIGNIFICATION Intrinsic Safety Standard UL913 is written by Underwriters Laboratories with reference to NEC (National Electric Code) and NFPA (National Fire Protection Association). This standard addresses the use of devices in Hazardous Locations (Flammable) and is recognized in the US and other parts of North America. UL normally uses this standard for safety evaluations. Intrinsic Safety Standard CSA 22.2 is written by Canadian Standards Association. This standard addresses the use of devices in Hazardous Locations (Flammable) and is recognized in the Canada and other parts of North America. UL also does safety evaluations to this standard. Intrinsic Safety Standards EN50014 and EN50020 are written by the European standards organization CENELEC, and these standards are recognized by European countries, Japan, and other countries as well. These standards address the use of devices in Zone 0 locations (Flammable). KEMA, NEMKO and TIIS use these standards for their evaluations. INTRINSIC SAFETY Intrinsically safe equipment is defined as "equipment and wiring which is incapable of releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause ignition of a specific hazardous atmospheric mixture in its most easily ignited concentration." (ISA-RP12.6) This is achieved by limiting the amount of power available to the electrical equipment in the hazardous area to a level below that which will ignite the gases. In order to have a fire or explosion, fuel, oxygen and a source of ignition must be present. An intrinsically safe system assumes the fuel and oxygen is present in the atmosphere, but the system is designed so the electrical energy or thermal energy of a particular instrument loop can never be great enough to cause ignition. 1-3

ADDITIONAL SAFETY INSTRUCTIONS a) Battery must be changed in Non-hazardous area. Battery must be of correct type, see instrument identification plates on instrument. b) Exchange of components other than original components may compromise the safety and is not recommended. BATTERY CHECK Thermo models TP-7 and TP-8 will indicate a flashing readout of Lo in the display. Replace battery if this occurs in order to prevent inaccurate readings. TP-5 model battery is considered good as long as a measured value appears on the display when pressing the ON button. However, if backlight will not light when in darkness or if measured value is unstable, battery replacement is recommended. REPLACING BATTERY a) Move into non-hazardous area. b) Remove the four screws holding the battery cover on the TP-5 and TP-8 models, or the three faceplate screws on the TP-7 model. c) Slide the battery cover out on the TP-5 and TP-8. Remove the circuit board/faceplate assembly on the TP-7. d) Lift battery at the outer end and pull the battery away from the plus/minus connections. e) Mount the new battery by pressing appropriate (+)/(-) connections together and push the battery to its correct position. f) (TP-5 and TP-8) Mount the battery cover and fasten the four screws. (TP-7) Reinstall the circuit assembly and fasten the three screws. CALIBRATION PROCEDURE Refer to API 7.3 for Calibration Verification Procedures: Calibration is not to be performed in any environment considered to be hazardous. Thermos should be calibrated at least annually to keep up to the standard of high accuracy. Please check for drift of electronic circuit, against proper temperature stable bath. Calibration requires two precision temperature reference points, for example; 0.0 C (32.0 F) and 90.0 C (194 F) in stable liquid calibration baths or similar certified temperature calibration equipment. Equipment needed: Ice Bath with certified reference thermometer. Warm to hot fluid bath between at 20 C (approx 68 F) or higher up to 90 C (approx 194 F) with certified reference thermometer. (see Note)* Small Phillips head or standard blade screwdriver to gain access to circuit board or calibration adjusters. Micro-style bladed screwdriver for electronics adjustment or similar tiny flat blade screwdriver for turning the adjusters. *Note for field calibration: If entire range capability of instrument is not required, the high adjustment can be made at a temperature relatively close to the common temperature of the liquid measured and accuracy will be maintained within the limited range. For example: If liquid to be measured is commonly less than 38 C (approx. 100 F), then a span or high point calibration can be made with a stable bath at room temperature of 21 C (70 F) to 27 C (80 F) using a certified thermometer for reference. Measurement accuracy will be maintained as long as liquid temperature to be measured does not exceed approx. 40 C (105 F). 1-4

To calibrate proceed with the following steps: The following instructions specify the TP-5, TP-7 and TP-8, other models are similar. **Refer to Appendix A for special instruction variation for Thermo model TP-2. a) For model TP-5, remove the two screws covering zero and span adjustment screws on the outside of front side of the case. The zero is the lower most adjuster and the span is located directly above. In order to access the adjustment screws on the TP-7 remove the circuit board assembly from case as described in Replacing Battery section above. TP-8 adjusting screw access requires removal of bottom cover plate by removing four screws. The adjusters on the TP-7 and TP-8 are found side by side on the lower edge of the circuit board. Refer to markings on the circuit board to verify which is zero and which is span. b) Lower the probe into the 0.0 C temperature bath and read temperature on the Thermo display. If deviation occurs, adjust the zero adjustment screw to get the same temperature as certifiable bath temperature. c) Lower the probe into the 90.0 C temperature stable bath and read temperature on the display. If deviation occurs, adjust the span adjustment screw to the same temperature as the certifiable bath temperature. d) Repeat step b) and step c) until same accordance between the Thermo and both bath temperatures. Span is now set to 90.0 C. e) Replace the covering screw on zero and span places on the TP-5 or reassemble the TP-7 or TP-8. APPENDIX A. The following refers to the special calibration procedure for the high zero adjustment on the TP- 2 model. This model is currently out of production. Many of these instruments remain in the field and these instructions are provided as a courtesy in order to assist in proper calibration procedures. The TP-2 differs from all other Thermo models due to its having three adjusters rather than two. The third adjuster (called the high Zero ) is used to correct calibration on Fahrenheit models only and only for temperatures over 200 F. Remove bottom cover to access the three adjusters. Follow the calibration procedures listed in the body of this document for temps under 200 F. After the zero and span have been set, then place the probe sensor in a heated circulating bath at between 195.0 F and 199.0 F. Allow the reading to stabilize. Flip the range switch on the right side front of the TP-2 so that it is in the up position over 200 F marking. Adjust the high zero adjuster until the display reads according to the following chart and then reassemble the instrument: High Range Table for TP-2 Bath Temp. F High Zero Reading 195.0-5.4 195.5-5.0 196.0-4.4 196.5-3.9 197.0-3.4 197.5-2.9 198.0-2.4 198.5-1.9 199.0-1.4 1-5