Operating instructions Pressure sensor. PN422x / / 2013

Similar documents
Operating instructions Pressure sensor. PP00xE /00 10/2011

Operating instructions Capacitive sensors KG AC (M18) / / 2010

Operating instructions Capacitive sensor KIA (M30) / / 2010

Operating instructions Binary level sensor LI / / 2013

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

PX3005. Rangeable Industrial Pressure Transmitter M-5721/1018

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Installation and Operation Manual

Technical Data. Dimensions

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

JUMO dtrans p30 Pressure Transmitter

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Technical Data. Dimensions

AMS 2710 PCB pressure sensor module with V output

Model 130M Pneumatic Controller

Technical Data. Dimensions

Technical Data. Dimensions

Pressure Measurement Single-range transmitters for general applications

ATM - Analog Pressure Transmitter

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

OC Panel High Limit Aquastat Kit, Manual Reset p/n

testo 6448 Compressed air counter probe Instruction manual

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

ATM/GR. Electronic pressure switches CUSTOMER BENEFITS

AMS 6916 Board mount pressure sensor with ratiometric analog output

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Digital Flow Switch. Series PFM7

ATM.ECO - Analog Pressure Transmitter

Pressure Measurement Single-range transmitters for general applications

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Technical Data. Dimensions

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

Electro Controls. Pressure WattsIndustries.co.uk

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Pressure Transmitters 36 F-27839

EPP4 Pressure Regulator Basic G 1/4"

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. Dimensions

IP65 Air Differential Pressure Switch

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications. Rated operating distance s n 2 mm

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

Instruction Manual Dräger MSI P7 and MSI P7 plus

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

SonoMeter 30 Energy Meters

Technical Data. Dimensions

AHE58/59 AC Servo System

Programmable pressure and temperature transmitters PTM/RS485

Precision pressure sensor Basic version Model CPT6020

OPTIBAR P 1010 C Technical Datasheet

Pressure transmitter PASCAL Ci4

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

Differential Pressure Transmiter

A4s Operation Manual

ATM.1ST/Ex - High Precision Transmitter

Inductive slot sensor

SCOPE OF THIS GUIDE STARTING-UP. 1 Check mini CORI-FLOW functional properties

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

LVU2800 Series. Ultrasonic Level Transmitter

Hand-held pressure calibrator with integrated pump Model CPH6600

AMS 6915 Board mount pressure sensor with digital output (I²C)

BAPI Pressure Line of Products - FAQs

Digital pressure gauge Model CPG500

Installation, use and maintenance instructions. Gas burner (5)

ATM.ECO/IS - Analog Transmitter with Temperature compensation

1)! DO NOT PROCEED BEYOND THIS MARK

Compact pressure switches for gas and air

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

SPD310/SPD360 Air Differential

Roller AC Servo System

Technical Data. Dimensions

Aquavar SOLO 2 Frequently Asked Questions

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

800 Series. Electronic Indicating Pressure Transmitter/Switch. Operating Instructions

Technical Data Sheet MF010-O-LC

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified

Instruction Manual Contact Pressure Vacuum Gauge

Programmable pressure and temperature transmitters PTM/RS485

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

ATM/Ex - Analog Pressure Transmitter

Pegas 4000 MF Gas Mixer InstructionManual Columbus Instruments

Gas density monitor With integrated transmitter Model GDM-100-TI

MoveRoll Conveyor Operating and Maintenance Manual

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

Parametrable / Programmable Pressure Transmitter

High-performance submersible pressure transmitter For level measurement Model LH-10

Torque Tube TB300 Digital Transmitters

Operating Instructions Process pressure transmitter IPT-1* Vers metalic sensor Foundation Fieldbus

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Pressure Switch for gas and air

Pressure Switch for gas and air

VERTICAL AIR COMPRESSORS

Transcription:

Operating instructions Pressure sensor PN422x 80002606 / 00 11 / 2013

Contents 1 Preliminary note...3 1.1 ymbols used...3 2 afety instructions...3 3 Functions and features...3 4 Function...5 4.1 witching function...5 5 Installation...5 5.1 Installation of the sensor...5 5.2 Installation of the grounding clamp...6 6 Electrical connection...8 7 Operating and display elements...9 8 enu...10 8.1 enu structure...10 8.2 Explanation of the menu...10 9 Parameter setting... 11 9.1 Parameter setting in general... 11 9.2 et output signals...13 9.2.1 et switching limits...13 9.2.2 etting of the output function...13 9.3 User settings (optional)...13 9.3.1 et the unit of measurement for system pressure...13 9.3.2 Configuration of the display...13 9.3.3 Zero-point calibration...14 9.3.4 et delay time for OUT1...14 9.3.5 etting the damping for OUT1...14 9.4 ervice functions...14 9.4.1 Read min/max values for the system pressure...14 10 Operation...15 10.1 Operating indicators...15 10.2 Read set parameters...15 10.3 Error indications...15 2

11 Technical data and scale drawing...16 11.1 etting ranges...16 12 Factory setting...17 1 Preliminary note 1.1 ymbols used Instructions > Reaction, result [ ] Designation of pushbuttons, buttons or indications Cross-reference Important note Non-compliance can result in malfunction or interference. Information upplementary note. 2 afety instructions Please read the product description prior to setup of the unit. Ensure that the product is suitable for your application without any restrictions. If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property can occur. Check the compatibility of the product materials (see technical data) with the media to be measured in all applications. Use in gases at pressures > 25 bar only on request. 3 Functions and features The pressure sensor detects the system pressure. It is shown on a display. It generates 1 output signal according to the set output configuration: OUT1 = switching signal for system pressure limit value. 3

Applications Type of pressure: relative pressure Order no. easuring range Permissible overpressure Bursting pressure bar PI 1) bar PI bar PI PN4220 0...400 0...5 800 600 8 700 1 000 14 500 PN4221 0...250 0...3 630 400 5 800 850 12 300 PN4222 0...100 0...1 450 300 4 350 650 9 400 PN4223 0...25 0...363 100 1 450 350 5 075 PN4224 0...10 0...145 75 1088 150 2 175 PN4226 0...2.5 0...36.3 20 290 50 725 mbar PI bar PI bar PI PN4227 0...1 000 0...14.5 10 150 30 430 bar inhg bar inhg bar inhg PN4229-1...1-30...30 20 590 50 1 476 1) For units with a measuring range of > 999 PI, 1/10 of the PI value is displayed. Consequently, the display value is to be multiplied by the factor 10. Example: Display value = 15; real value = 15 10 = 150 PI. Pa = bar 10 / kpa = bar 100 Pressure Equipment Directive (PED): Units with a final value of the measuring range of 1...400 bar comply with section 3, article (3) of the Directive 97/23/EC and are designed and manufactured for group 2 fluids (stable gases and non-superheated liquids) in accordance with the sound engineering practice. Avoid static and dynamic overpressure exceeding the specified overload pressure by taking appropriate measures. The indicated bursting pressure must not be exceeded. Even if the bursting pressure is exceeded only for a short time, the unit may be destroyed. ATTENTION: Risk of injury! Use in gases at pressures > 25 bar only on request. Indication of the current system pressure as from 1% of the final value of the measuring range. Display 0% does not mean that no pressure is applied to the system! 4

4 Function 4.1 witching function OUT1 changes its switching state if it is above or below the set switching limits (P1, rp1). The following switching functions can be selected: Hysteresis function / normally open: [OU1] = [Hno] ( Fig. 1). Hysteresis function / normally closed: [OU1] = [Hnc] ( Fig. 1). First the set point (P1) is set, then the reset point (rp1) with the requested difference. Window function / normally open: [OU1] = [Fno] ( Fig. 2). Window function / normally closed: [OU1] = [Fnc] ( Fig. 2). The width of the window can be set by means of the difference between P1 and rp1. P1 = upper value, rp1 = lower value. P 1 P FE 2 P rp HY P rp 1 0 1 0 t Hno Hnc 1 0 1 0 t Fno Fnc P = system pressure; HY = hysteresis; FE = window 5 Installation 5.1 Installation of the sensor Before installing and removing the unit: ake sure that no pressure is applied to the system. Insert the unit in a ¼ NPT process connection. Tighten firmly. 5

5.2 Installation of the grounding clamp If installed in an ungrounded pipe system (e.g. plastic pipes), the unit must be grounded. The grounding clamp (order no. E43321) serves this purpose. It is designed to discharge noise voltages in case the sensor is mounted to ungrounded installations. It is available as an accessory and to be used preferably on PN42xx series sensors. The earthing strap and the clamping device must be in contact with the sensor sleeve outside of the area where the type label is! Attach the clamping device of the grounding clamp to the sensor in the area beneath the 12 connector (A). Bend the earthing strap around the sensor sleeve and insert it in the slot of the clamping device (B). A B 6

Push the earthing strap into the clamping device until it is in close contact with the sensor sleeve. Use an adequate screwdriver to tighten the lower screw until the earthing strap can no longer be moved on the sensor sleeve (C). ake sure that the washer is fitted on the upper screw. Fasten the ground cable with the upper screw and an adequate screwdriver to the clamping device (D). D C 7

6 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. For the output circuit, the same protective measures as for the supply circuit must be taken. Insert a miniature fuse according to IEC60127-2 heet 1 (5 A fast acting). The permissible potential difference between supply and output circuit is max. 300 V. The equalisation of potential of metal housing parts must be ensured via the sensor housing. Ensure an electrically conductive connection. The grounding clamp (order no. E43321) can be used for the equalisation of potential. Due to the integrated EC filters, leakage currents of typ. < 0.5 ma can flow via the potential equalisation to the earth potential. If several units are used in parallel, take into account that the leakage currents add. The applicable standards must be adhered to. Disconnect power. Connect the unit as follows: Connector view (at the unit) 4 5 3 1 2 1 2 3 4 5 n.c. L1 N A B A: upply circuit B: Output circuit : afe separation Core colours of ifm sockets: 1 = BN (brown), 2 = BU (blue), 4 = BK (black), 5 = WH (white) 8

7 Operating and display elements 1 2 ode/enter et 3 4 1: 7-segment display - Display of the current system pressure 1). - Indication of the parameters and parameter values. 2: LED red Indication of the switching status; lights when the output is switched. 3: et button - etting of the parameter values (scrolling by holding pressed; incremental by pressing briefly). 4: ode/enter button - election of the parameters and acknowledgement of the parameter values. 1) PI value in case of units with a measuring range > 999 PI = displayed value 10 9

8 enu 8.1 enu structure RUN = ode/enter = et RUN 8.2 Explanation of the menu P1/rP1 10 Upper / lower limit value for system pressure at which OUT1 switches. OU1 Output function for OUT1: witching signal for the pressure limit values: hysteresis function [H..] or window function [F..], either normally open [. no] or normally closed [. nc]. EF Extended functions / opening of menu level 2. HI / LO aximum / minimum value memory for system pressure. COF Zero-point calibration. CAr Reset of the zero-point calibration.

d1 / dr1 dap di Uni witch-on delay / switch-off delay for OUT1. Damping for OUT1. Update rate and orientation of the display. tandard unit of measurement for system pressure. 9 Parameter setting During parameter setting, the unit remains in the operating mode. It continues to monitor with the existing parameters until the parameter setting has been completed. 9.1 Parameter setting in general 3 steps must be taken for each parameter setting: 1 Parameter selection Press [ode/enter] until the requested parameter is displayed. ode/enter et 2 etting of the parameter value Press [et] and keep it pressed. > > Current setting value of the parameter flashes for 5 s. ode/enter et > > After 5 s: etting value is changed: incrementally by pressing the button once or continuously by keeping the button pressed. Numerical values are incremented continuously. To reduce the value: let the display move to the maximum setting value. Then the cycle starts again at the minimum setting value. 3 Acknowledgement of the parameter value Briefly press [ode/enter]. ode/enter et > > The parameter is displayed again. The new setting value is saved. etting of other parameters: tart again with step 1. Finishing the parameter setting: [Press ode/enter] several times until the current measured value is displayed or wait for 15 s. The unit returns to the operating mode if no button is pressed for 15 s after acknowledgement of the new parameter value. 11

Change from menu level 1 to menu level 2: Press [ode/enter] until [EF] is displayed. ode/enter et Briefly press [et]. > > The first parameter of the submenu is displayed (here: [HI]). ode/enter et Locking / unlocking The unit can be locked electronically to prevent unintentional settings. ake sure that the unit is in the normal operating mode. Press [ode/enter] + [et] for 10 s. > > [Loc] is displayed. ode/enter et During operation: > [Loc] is briefly displayed if you try to change parameter values. For unlocking: Press [ode/enter] + [et] for 10 s. ode/enter et > > [Loc] is displayed. On delivery: not locked. Timeout: If no button is pressed for 15 s during parameter setting, the unit returns to the operating mode with unchanged values. 12

9.2 et output signals 9.2.1 et switching limits elect [P1] and set the value at which the output switches. elect [rp1] and set the value at which the output switches off. rp1 is always lower than P1. The unit only accepts values which are lower than P1. 9.2.2 etting of the output function elect [ou1] [Hno] = hysteresis function/normally open, [Hnc] = hysteresis function/normally closed, [Fno] = window function/normally open, [Fnc] = window function / normally closed. 9.3 User settings (optional) 9.3.1 et the unit of measurement for system pressure elect [Uni] and set the unit of measurement: [bar] (= bar / mbar), [PA] (= Pa / kpa), [inh] (= inhg), or [PI]. For units with a measuring range of > 999 PI, 1/10 of the PI value is displayed. Consequently, the display value is to be multiplied by the factor 10. Example: Display value = 15; real value = 15 * 10 = 150 PI. The unit is delivered with stickers for different units of measurement and correction factors. Attach the corresponding sticker to the unit or mark the sticker. 9.3.2 Configuration of the display elect [di] and set the update rate and orientation of the display: [d1]: update of the measured values every 50 ms. [d2]: update of the measured values every 200 ms. [d3]: update of the measured values every 600 ms. [Ph]: display of the pressure peaks remains for a short time (peak hold). [rd1], [rd2], [rd3], [Ph]: display as for d1, d2, d3, Ph; rotated by 180. [OFF]: the display is switched off in the operating mode. 13

9.3.3 Zero-point calibration elect [COF] and set a value between -5% and 5% of the final value of the measuring range. The internal measured value "0" is shifted by this value. Zero-point calibration reset: Press [ode/enter] until [CAr] is displayed. Press and hold [et] until [---] is displayed. Briefly press [ode/enter]. 9.3.4 et delay time for OUT1 [d1] = switch-on delay for OUT1. [dr1] = switch-off delay for OUT1. elect [d1] or [dr1] and set a value between 0.1 and 50 s (at 0.0 the delay time is not active). 9.3.5 etting the damping for OUT1 elect [dap] and set a value between 0.01 and 4.00 s; (at 0.00 [dap] is not active). dap value = response time between pressure change and change of the switching status in seconds. [dap] influences the switching frequency: f max = 1 2dAP. 9.4 ervice functions 9.4.1 Read min/max values for the system pressure elect [HI] or [LO], briefly press [et]. [HI] = maximum value, [LO] = minimum value. Delete memory: elect [HI] or [LO]. Press and hold [et] until [---] is displayed. Briefly press [ode/enter]. 14

10 Operation After power on, the unit is in the Run mode (= normal operating mode). It carries out its measurement and evaluation functions and provides output signals according to the set parameters. 10.1 Operating indicators 1 2 1 Current system pressure in bar, Pa, PI. PI value in case of units with a measuring range > 999 PI = display value 10. 2 witching status OUT1. 10.2 Read set parameters Briefly press [ode/enter]: the parameters are displayed one after the other. Briefly press [et]: the corresponding parameter value is displayed for about 15 s. After another 15 s the unit returns to the Run mode. 10.3 Error indications [OL] [UL] Overload pressure (above measuring range) Underload pressure (below measuring range) 15

11 Technical data and scale drawing Information according to culus approval: Enclosure type 1 Ambient temperature 0 40 C For use in pollution degree 2 environment Further technical data and scale drawing at www.ifm.com Data sheet search Enter the article number. 11.1 etting ranges P1 rp1 min max min max ΔP bar 4 400 2 398 1 PI * 10 6 580 3 577 1 Pa 0.4 40.0 0.2 39.8 0.1 bar 2 250 1 249 1 PI * 10 4 363 2 361 1 Pa 0.2 25.0 0.1 24.9 0.1 bar 1.0 99.9 0.5 99.5 0.1 PI * 10 1 145 1 144 1 Pa 0.10 10.00 0.05 9.95 0.01 bar 0.2 25.0 0.1 24.9 0.1 PI 4 363 2 362 1 Pa 0.02 2.50 0.01 2.49 0.01 bar 0.10 9.99 0.05 9.94 0.01 PI 1 145 1 144 1 kpa 10 999 5 994 1 bar 0.02 2.50 0.01 2.49 0.01 PI 0.4 36.3 0.2 36.2 0.1 kpa 2 250 1 249 1 ΔP = step increment PN4220 PN4221 PN4222 PN4223 PN4224 PN4226 16

PN4229 PN4227 ΔP = step increment P1 rp1 min max min max ΔP mbar 10 999 5 994 1 PI 0.1 14.6 0.1 14.5 0.1 kpa 1.0 99.9 0.5 99.4 0.1 bar -0.97 1.00-0.99 0.98 0.01 inhg -29 30-30 29 1 kpa -97 100-99 98 1 12 Factory setting Factory setting User setting P1 rp1 OU1 25% VR 23% VR Hno COF 0.0 d1 0.0 dr1 0.0 dap 0.06 di d2 Uni EW = final value of the measuring range bar / mbar ore information at www.ifm.com 17