Medical Gas Control Panel

Similar documents
Installation Instructions for NP100 Series Nitrogen Control Panels

Pressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions

- GAS REGULATOR - COMPACT STYLE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Installation Instructions

Steel Spring Driven Reel Instruction Manual

Shut-Off Valves and Valve Boxes

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Types 749B and R130 Changeover Manifolds

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

Natural Gas to L.P. Gas Conversion Kit

Natural Gas to L.P. Gas Conversion Kit

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

OPERATION MANUAL NTF-15

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Push-To-Set Intermittent Suction Unit (PTS-ISU) Instructions for Use

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

PENBERTHY SUBMERSIBLE AUTOMATIC SUMP DRAINER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MMR Air Mask With. with Quick-Connect Hose

OPERATING AND MAINTENANCE MANUAL

Halsey Taylor Owners Manual STOP!

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

MEGR-1912 Instruction Manual

FRAGMENTATION INSTRUCTION & OPERATION HANDBOOK

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

Booster Pump PB4-60 Replacement Kits

OPERATION MANUAL NTF-60 Plus

Installation, Operation, and Maintenance Manual

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Interface Devices, Inc. Hydraulic Mini Mule

INSTALLATION INSTRUCTIONS MANUAL ON/OFF SAFETY VALVE/PILOT KIT MODEL GA9050A-1 (F0235)

RD(H)20/25 Pressure-Reducing Regulator User Manual

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

1 Exam Prep. Tabs and Highlights

TECHNICAL DATA. Q= Cv S

Halsey Taylor Owners Manual

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

V46 Series 2-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Installation/Care/Use Manual

Installation and Maintenance Manual. Compact Medical Gas Outlets

MEGR-1627 Instruction Manual

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

MANUAL GAS MANIFOLDS

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA CAUTION

1020 Industrial Drive, Orlinda, TN fax

Installation and Maintenance Manual. Dual Medical Gas Outlets

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Operation Manual Piston Sensed Gas Pressure Regulators

Your safety and the safety of others are very important.

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Bermad Pressure Reducing. Model: 42T

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

NGP-250/500 Nitrogen Generator Quick Start Guide

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

DUPLEX PRESSURE REDUCING SET

Anti-flood device Model B-1

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

Instruction Manual O-Ring Ejector Chlorine & Sulfur Dioxide to 500 PPD (10 kg/h)

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

1805 Series Relief Valves

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

453 Series Steam Heated Vaporizing Regulator

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA. Trimpac 244a. September 16, 2013

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

The conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

Tri-Safem Model I1 Regulator. INSTRUCTIONS and PARTS

Product Information News

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Model 420-HY Pressure Regulating Hydrant Valve

TECHNICAL DATA CAUTION

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

MEDICAL EQUIPMENT CATALOG

Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA USA Tel: Ref Rev.

Installation & Operating Instructions for Genesys Analog Series Manifolds

Product Information News September 26, 2003

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Inert Air (N2) Systems Manual

TECHNICAL DATA. Q = C v P S

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Protocol Switchover Station

Transcription:

Medical Gas Control Panel INSTALLATION & MAINTENANCE MANUAL 255105 (Rev. 6) 2018-04

2 255105 (Rev. 6) 2018-04

1.0 User Responsibilities The information contained in this installation and operation maintenance manual pertains only to the Ohio Medical gas control panel. The gas control panel will operate in conformance with the descriptions outline in this manual only when it is operated, maintained and serviced properly and in compliance with the instructions contained herein. The gas control panel should be tested and examined periodically. Any parts that are found to be damaged, corroded, contaminated etc. should be replaced. Should such repair or replacement become, necessary, contact Ohio Medical LLC at 1-800-448-0770 for original equipment replacement parts. 2.0 System Description and Function The Ohio Medical gas control panel is designed to supply medical air tools with variable pressures up to 200 psig. The gas control panel is comprised of supply and delivery gauges, a pressure regulator, a shut off valve, DISS (Diameter Index Safety System) outlet connection and an outlet pipe, which allows connections to additional outlets. For ease of installation the Ohio Medical gas control panel is delivered in two sub-assemblies, the box assembly and the front frame assembly. The box assembly is made of the box itself, mounting brackets, hardware and type K copper stubs. The front frame assembly consists of the frame, supply valve and supply and delivery gauges, pressure regulator, shut off valve and the DISS outlet connection. 3.0 Mounting Instructions The box assembly includes brackets for ease of installation. The bracket includes a means to allow for varying wall thickness. The brackets should be adjusted so that the front edge of the box sub assembly will be approximately 3/8 past the finished wall with the mounting hardware tightened. The box should then be securely fastened to the wall studs at the desired height. The copper pipe stubs may now be brazed to the appropriate pipeline. The pipe stubs are clearly marked with color coded labels indicating the correct gas. Take extreme caution not to overheat the panel during the brazing process by wrapping the lower part of the pipe stub in a cool damp cloth. After the brazing has been completed the system may be pressure tested per NFPA 99 and/or local standards. All joints should be inspected for leaks. It is important to bypass the regulator and gauges in the gas control panel when performing the static pressure test on the completed pipeline system. To facilitate this, the back box is supplied with two flexible hoses joined together via a flared coupling, connecting the inlet stub directly to the outlet stub inside the box. After the static pressure testing is complete the gas control will be readied for use by disconnecting the flexible hoses; and connecting the free end of the inlet flexible hose to the inlet flare adapter. Likewise connect the free end of the outlet flexible hose to the outlet flare adapter. Now the flow of the gas from the inlet stub is directed through the components prior to exiting the outlet stub. Check all connections for tightness before putting the gas control panel into service. 255105 (Rev. 6) 2018-04 3

4.0 Operation Start-Up 1. Open the supply valve and verify incoming pressure by observing the supply gauge. 2. Connect the surgical equipment to the local and/or remote DISS (Diameter Index Safety System) Outlet(s). 3. Turn the pressure regulator knob either clockwise (increasing) or counter clockwise (decreasing) while observing the delivery pressure gauge until the desired pressure is met. Shut Down 1. Close the supply valve, and operate the surgical tool to bleed 2. Turn the regulator knob fully counter clockwise 3. When the pressure is zero disconnect the surgical equipment 5.0 Servicing Before servicing the gas panel, follow the shut down procedure and bleed pressure from the nearest zone or lateral valve and then disconnect the incoming line. Remove the screws from the gas panel front assembly, and disconnect the inlet and outlet flexible tubing located on the backside of the front panel. Tightening tube fittings can eliminate most leaks. Use caution not to bend or over tighten fittings. When replacing fittings use Teflon tape. 6.0 Trouble Shooting PROBLEM Difficulty in Maintaining Pressure Low Operating Pressure Difficulty with Shut Off Valve DISS Outlet Leaks Difficulty with Regulator Knob Hissing Noise CAUSE Check for Leaks Inside Panel Defective Regulator Check Source Pressure Check for Leaks Inside Panel Defective Regulator Replace Shut Off Valve Replace Valve Seats and/or Outlet Valve Lubricate Knob or Replace Normal, when Regulator Pressure is Reduced. Regulator is relieving type. 4 255105 (Rev. 6) 2018-04

ITEM QTY DESCRIPTION NITROGEN PART NUMBER AIR PART NUMBER CO 2 PART NUMBER 1 1 Face Plate 261798 261913 263284 2 1 2 Way Brass Valve 261778 261778 261778 3 2 Gauge 261781 261781 261781 4 1 DISS Fitting 261731 261729 261753 5 1 Regulator (Set to 0 to 300 PSIG) 261766 261766 261766 6 2 Flared Adapter 261787 261787 261787 7 2 Flexible Hose 261772 261772 261772 8 1 Flared Union 261835 261835 261835 255105 (Rev. 6) 2018-04 5

NOTES: 6 255105 (Rev. 6) 2018-04

NOTES: 255105 (Rev. 6) 2018-04 7

North America United States Customer Service, Distribution Center Technical Support, Sales and Service Equipment Service Center Ohio Medical LLC 1111 Lakeside Drive Gurnee, IL 60031 USA P: 866 549 6446 P: +1 847 855 0800 F: +1 847 855 6218 info@ohiomedical.com www.ohiomedical.com 2018 Ohio Medical LLC. This document contains information that is proprietary and confidential to Ohio Medical LLC. Use of this information is under license from Ohio Medical LLC. Any use other than that authorized by Ohio Medical LLC is prohibited. 255105 (Rev. 6) 2018-04