Operating and maintenance manual Filter and reducing station Series / 1.0

Similar documents
Installation and operating manual. Pneumatic control station LK product no: PCS 1-10

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

User Instruction Manual

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Pressure maintenance valve SDV-P / SDV-P-E

Installation, Operating & Maintenance Instructions. Variable leak valve with manual actuator. Series 590 DN 16 mm (I. D. ⅝") E

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Manual Actuated Boiler Blowdown Valves

Flowmeter. Original operating manual DFM

OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER

APCO ARV CLEAN WATER AIR RELEASE VALVES. Model 50A

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Modular valve block. Operating manual Series MVB 100/200. Version BA EN Print-No TR MA DE Rev001

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

RS(H)20, 25 USER MANUAL

Operation Manual Air Saver Unit ASV5000 Series

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

Type BBS-03, BBS-05, BBS-06, BBS-25

Diaphragm Pressure Keeping Valve

CARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition

Innovative Vacuum for Automation. Operating Instructions Dust Filter STF P / STF-D P.

Siphon vessel / Priming aid

INSTALLATION COMMISSIONING, OPERATION & MAINTENANCE MANUAL

Diaphragm relief valve

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual

Operating instruction

Pneumatic Service Unit

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

Control Valve with ZK Radial Stage Nozzle ZK 210. Original Installation Instructions English

Non-Return Valve SRK 22A

Direct Operated Precision Regulator Modular Style. Standard Specifications

Ball valve. Operating instructions for series. Version BA Print-No TR MA DE Rev001

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Manual Brass Shut-Off Valve DN10 through DN22

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Pressure relief valve

Control Valves ZK 610 ZK 613

Pressure relief valve

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

Installation & Operation Manual Proven Quality since 1892

neska High-Speed Handpiece P320

Declaration of Conformity as per Directive 97/23/EC

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

COSASCO 3600 PSI SINGLE ISOLATION SERVICE VALVE (FR) MAINTENANCE

AIR INLINE METAL SHEAR

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Operating Instructions Hand Test Pump BHP 700

OPERATION MANUAL NTF-15

Operating instructions - Translation of the original -

air/hydraulic nut riveter heavy-duty vacuum system

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Inverted Bucket Steam Trap IB 16A-7

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

GI Series Diaphragm Pressure Gauge Guard

Type /2-Way Globe Valve 3/2-Wege-Geradsitzventil Vanne à siège droit 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Installation, Operating & Maintenance Instructions. All-metal gate valve with extended pneumatic actuator. Series 48 DN mm (I.D.

Installation / Operation / Maintenance Manual KLINGER Reflex Level Gauge Type R 25

Declaration of Conformity as per Directive 97/23/EC

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

Instruction Manual. Alfa Laval SB Pressure Exhaust Valve ESE02965-EN Original manual

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. FAS Brass Check Valve RDL

MF2M Monnier Miniature Compressed Air Filter

Two-stage valve type NE

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

WW-720. Pressure Reducing Control Valve

Attention: This operator's manual should be read carefully before using the pistol! ENGLISH

Neotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions

Instruction Manual Contact Pressure Vacuum Gauge

MoveRoll Conveyor Operating and Maintenance Manual

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

PRESSURE REDUCING STATION INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN Original manual

Bladder Damper PP/PVC

MANUALLY OPERATED VALVE VLM SYNCROFLUX TECHNICAL MANUAL MT042/E

Type 2080 FALTENBALGVENTIL BELLOWS VALVE VANNE A SOUFFLET. Operating Instructions. Bedienungsanleitung Manuel d utilisation

PRESSURE TEST PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model No: PTP100. Part No: GC01/09

PV4 and PV6 Piston Valves

OPERATING AND MAINTENANCE MANUAL

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

Operating Instructions in compliance with Pressure Equipment Directive 2014/68/EU. AWA Change-over Valve

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

Operating instructions for KLINGER SCHÖNEBERG ball valves type RK-Chemoball, type RK-Proball and type RK-Ecoball

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Pressure Reducing Valve DMV 750

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

Transcription:

Operating and maintenance manual Filter and reducing station Series 961 04.2017 / 1.0

Original instructions ARCA Regler GmbH. All rights reserved. Cover picture background: Freepik.com

ARCA Regler GmbH Table of contents Table of contents 1 General data... 4 1.1 Validity of the manual... 4 1.2 Contact details... 4 1.3 Other applicable documents... 4 1.4 Place of storage of the manual... 4 2 Safety... 5 2.1 General safety information... 5 2.2 Explanation of symbols and notices... 5 2.3 Structure of the warning notices... 6 2.4 Intended use... 6 2.5 Inappropriate use... 6 2.6 Qualification of the personnel... 6 2.7 Operator's duty of care... 7 2.8 Personal protective equipment... 8 3 Functional description... 10 4 Installation... 11 5 Adjustment... 12 6 Maintenance... 13 7 Detail drawing... 14 8 Dimensional drawing... 15 9 Fault removal... 16 10 Disposal and recycling... 17 Series 961 04.2017 / 1.0 3 / 18

1 General data ARCA Regler GmbH 1 General data This operating manual contains instructions that enable the product to be safely and properly installed, put into operation and maintained. The target group for this operating manual is exclusively specially trained and authorised technical personnel. Please contact the manufacturer if you encounter problems that cannot be solved with the aid of this operating manual. The product is subject to technical changes at any time. 1.1 Validity of the manual This operating manual applies to the product in the version described in the device passport or data sheet. 1.2 Contact details Further information about the product can be obtained from: Manufacturer's address ARCA Regler GmbH Kempener Str. 18 D-47918 Tönisvorst Tel.: +49 (0) 2156-7709-0 Fax: +49 (0) 2156-7709-55 E-mail: sale@arca-valve.com www.arca-valve.com 1.3 Other applicable documents The product can be delivered as part of an actuator and equipped with additional components that are described in their own operating manuals. The instructions as well as the warning and safety information contained therein must also be observed. Furthermore, the following documents apply in addition to this operating manual. Device passport (only in connection with an actuator) Technical data sheet 1.4 Place of storage of the manual The operating manual and all other applicable documents are part of the product. They must be kept in the immediate vicinity of the product and must be accessible to the personnel at all times. 4 / 18 04.2017 / 1.0 Series 961

ARCA Regler GmbH 2 Safety 2 Safety 2.1 General safety information The operating manual contains detailed descriptions for the safe installation, commissioning and maintenance of the product. Read this operating manual attentively in its entirety in order to familiarise yourself with the product. Particular attention must be paid to the information in this chapter. 2.2 Explanation of symbols and notices Safety and warning instructions are intended to avoid hazards to the life or health of operating or maintenance personnel, and to avoid material damage. It is emphasised through the use of the special terms defined here. Additionally, their location is marked by warning symbols (pictograms). The signal terms used have the following meanings: DANGER means that death, serious injuries and/or considerable damage to property will occur if the corresponding preventive measures are not taken and maintained. WARNING means that death, serious injuries and/or considerable damage to property can occur if the corresponding preventive measures are not taken and maintained. CAUTION means that minor injuries and/or damage to property can occur if the corresponding preventive measures are not taken and maintained. NOTICE indicates an important item of information about the product itself or how the product should be handled, to which special attention should be paid. Series 961 04.2017 / 1.0 5 / 18

2 Safety ARCA Regler GmbH 2.3 Structure of the warning notices Section-related warning notice Section-related warning notices refer to the entire chapter, sections or several paragraphs within this operating manual. Section-related warning notices are structured as follows: DANGER Type and source of the danger Possible consequences of disregard Measure to avoid the danger Further measures Embedded warning notice Embedded warning notices refer to a certain area within a section. They apply to smaller information units than the section-related warning notices. Embedded warning notices are structured as follows: DANGER! Instructions for avoiding a dangerous situation. 2.4 Intended use The product complies with laws, regulations and standards valid at the time of delivery. The product does not pose a danger to people, property or environment if it is used for its intended purpose and the warning notices contained in this operating manual and attached to the product are observed. This applies to the entire lifetime, from the delivery, assembly and operation to the disassembly and disposal. The following is deemed to be used for the intended purpose: Operate the product exclusively in accordance with this operating manual and in accordance with the specification in the order confirmation and the device pass. Use exclusively original ARCA spare parts for the maintenance of the product. 2.5 Inappropriate use Inappropriate use is use of the product other than as described is the chapter entitled Intended use. In the addition, the following applies: Unauthorised modifications to the product can lead to injuries, damage to property and malfunctions. The user alone bears this risk. Warranty and liability claims are excluded. 2.6 Qualification of the personnel The product is exclusively intended for use in plants and installations in which trained technical personnel carry out the necessary work. Technical personnel are persons who are entrusted with the installation, commissioning and operation of this product and who have the appropriate qualifications for their work activities, such as, for example: 6 / 18 04.2017 / 1.0 Series 961

ARCA Regler GmbH 2 Safety Persons Activity training or instruction in accordance with current technical safety standards in the maintenance and usage of appropriate safety equipment. Training in First Aid. In the case of systems with explosion protection: training or instruction and authorisation to carry out work on potentially explosive systems. Repair work may be carried out only by trained and qualified technical personnel. Work on electrical equipment may be carried out only by trained electricians or persons who have received electrotechnical instruction. Instructed persons Persons Persons with a recognised technical education with a recognised electrotechnical education Superiors with relevant skills ARCA service personnel Transport X X X X X Installation X X X X X Commissioning X X X X Maintenance X X X X X Fault finding X X X Mechanical troubleshooting Electrical troubleshooting Repairs X X X X Disposal X X X X X X X X X 2.7 Operator's duty of care To avoid accidents, malfunctions and environmental impacts, the respective person responsible for the transport, commissioning, operation, maintenance and disposal of the product must ensure the following: Observation of all warning and danger notices. Regular instruction of personnel on all applicable questions of work safety, the operating manual and in particular the safety instructions that it contains. Regulations and work instructions for safe working as well as the corresponding instructions for the conduct of the personnel in case of accidents and fire are to be kept at the ready at all times and hung up in the plant if necessary. Operate the product only if it is in perfect working order. Use only spare parts, lubricants and operating resources approved by the manufacturer. Observe the specified operating conditions and requirements at the place of installation. Provide all necessary devices and the personal protective equipment required for the respective task. Series 961 04.2017 / 1.0 7 / 18

2 Safety ARCA Regler GmbH Refer to the chapter entitled Maintenance for the prescribed maintenance intervals and comply with the corresponding regulations. Allow installation, commissioning and maintenance of the product to be carried out only by qualified and trained personnel in accordance with this operating manual. The operator must ensure that the product is used for its intended purpose. Before commissioning the product the operator must carry out a risk assessment and define appropriate inspection and maintenance intervals according to the operating conditions. 2.8 Personal protective equipment Personal protective equipment must be worn during work in order to minimise health risks. During work, always wear the protective equipment necessary for the respective work Follow the notices about personal protective equipment displayed in the working area. Always wear Protective clothing Tight-fitting work clothes with a low tear resistance, with narrow sleeves and without protruding parts. They primarily serve to protect against being caught up by moving machine parts. Do not wear rings, chains or other jewellery. Safety shoes To protect against heavy falling parts and slipping on smooth floors. Wear in case of particular environmental conditions Special protective equipment is necessary in particular environmental conditions. It is to be selected according to the environment. Safety glasses To protect the eyes against flying parts and splashes of liquids. 8 / 18 04.2017 / 1.0 Series 961

ARCA Regler GmbH 2 Safety Wear in case of particular environmental conditions Special protective equipment is necessary in particular environmental conditions. It is to be selected according to the environment. Helmet To protect against falling and flying parts and materials. Hearing protection To protect against hearing damage. Series 961 04.2017 / 1.0 9 / 18

3 Functional description ARCA Regler GmbH 3 Functional description General Function The supply of air free from dust, oil and water is a prerequisite for the reliable functioning of pneumatic actuators and control devices. Since the air is usually withdrawn from a supply network with a fluctuating pressure, it has to be cleaned and regulated to the necessary pressure accordingly in a filter and reducing station. The ARCA filter and reducing station type 961 is designed for the precise regulation of pressure with high air quantities. It was specially designed for use on pneumatic actuators and control devices. This proven, compact station is distinguished by the following properties: High flow capacity exact pressure control quick response simple installation reliable oil and water separation reusable filter The filter and reducing station is a diaphragm-controlled pressure reducing valve. The desired output pressure can be adjusted with the set screw (1). See also the chapter entitled [5] Adjustment The filter water collection system ensures that condensate residues, oil and contaminants such as rust, dust and tinder are reliably retained and downstream high-value control devices are not damaged. The separated fluid can be drained off from time to time via a drain screw (18). By unscrewing the housing screws (4), the built-in filter (16) and the seat behind it can be cleaned and reused without having to remove the filter and reducing station. See also the chapter entitled [7] Detail drawing 10 / 18 04.2017 / 1.0 Series 961

ARCA Regler GmbH 4 Installation 4 Installation Place of installation Air connections Assembly Mounting position The filter and reducing station is to be installed as close as possible to the associated device. It is recommended to allow sufficient space underneath the filter and reducing station to be able to drain off the condensate and remove the lower housing shell. See also the chapter entitled [8] Dimensional drawing The filter and reducing station has four ¼" NPT connections. The air inlet, "IN", can be mounted on the left or right. The air outlet, "OUT", is then on the opposite side. Positioned at a right angle to these connections are two further connections, "Gauge", which are connected to the air outlet. According to the mounting place and position, a manometer can optionally be connected here. The unused connection opposite the manometer must then be sealed with a sealing plug. Mounting on the actuator drive or a wall is possible using additional fixing plates. A pre-filter with automatic drain is to be installed in case of frequent contamination. Please note: CAUTION Mounting position Vertical, drain screw (18) facing downwards Series 961 04.2017 / 1.0 11 / 18

5 Adjustment ARCA Regler GmbH 5 Adjustment The desired output pressure can be adjusted with the set screw (1). Loosen the lock nut (2) Adjust the output pressure to the required value with the set screw (1). NOTICE! Turning the set screw (1) clockwise increases the output pressure, turning it counter clockwise reduces the output pressure. Tighten the lock nut (2) again to secure. 1 2 18 Illustration 1: Adjustment 12 / 18 04.2017 / 1.0 Series 961

ARCA Regler GmbH 6 Maintenance 6 Maintenance CAUTION Fluid under pressure Danger to people and the environment! Wear suitable protective equipment Collect fluid The filter and reducing station is practically maintenance free. However, the following maintenance work is to be carried out at regular intervals. Drain off separated fluid Clean the filter CAUTION! Wear safety glasses if necessary! Undo the drain screw (18) and collect the fluid. CAUTION! Shut off the air supply and bleed the filter and reducing station by unscrewing the drain screw (18). See also the chapter entitled [7] Detail drawing Loosen and remove the housing screws (4) Remove the filter housing (17) Remove and clean the filter (16) NOTICE! Blow out the filter (16) with compressed air from the inside outwards. A new filter (16) must be installed if the filter (16) is damaged or if cleaning is no longer possible. Series 961 04.2017 / 1.0 13 / 18

7 Detail drawing ARCA Regler GmbH 7 Detail drawing 4 1 2 3 10 11 12 13 5 14 6 7 15 16 8 17 9 4 18 Illustration 2: Detail drawing 1 Set screw 2 Lock nut for adjustment 3 Knurled nut 4 Housing screws 5 Spring housing 6 Spring plate 7 Setpoint spring 8 *Complete diaphragm 9 Housing, journal bearing 10 * Plug 11 * Conical spring 12 Spring fastener 13 * O-ring 14 Connection block 15 * O-ring 16 * Filter 17 Filter housing 18 Drain screw * These parts can only be procured as a repair set. 14 / 18 04.2017 / 1.0 Series 961

ARCA Regler GmbH 8 Dimensional drawing 8 Dimensional drawing Illustration 3: Dimensional drawing 1 Drain screw 2 Second manometer connection 3 Mounting bracket, adjustable as required all round All four ¼" NPT connections. Mounting bracket available on request. Series 961 04.2017 / 1.0 15 / 18

9 Fault removal ARCA Regler GmbH 9 Fault removal WARNING Improper troubleshooting work Risk of injury! For all troubleshooting work, observe the corresponding notes in particular the safety instructions in this operating manual or in the operating manuals for the additionally installed components. Please contact the manufacturer if problems occur that are not described in this table. Fault Possible causes Action Leak at the air connection Screw connection leaking Tighten the screw connection Leak at the drain screw (18) Air output too low Threaded connection between screw connection and filter and reducing station leaking Re-seal the screw connection Drain screw (18) not tightened Tighten drain screw (18) Filter and reducing station incorrectly adjusted Screw in the set screw (1) until the desired pressure is achieved Filter (16) dirty Clean or replace the filter (16) 16 / 18 04.2017 / 1.0 Series 961

ARCA Regler GmbH 10 Disposal and recycling 10 Disposal and recycling WARNING Operating media and auxiliary materials that are hazardous to health Danger to people and the environment! Wear suitable protective equipment If applicable, collect and dispose of rinsing medium or residual medium. Particular attention is to be paid to dead spaces (pressure compensation, bellows, etc.) Observe the legal regulations for the disposal of media that are hazardous to health ARCA products are modularly constructed and can be sorted by material into the following components. Electronic components Metals Plastics Greases and oils Packaging material The general rules are: greases and oils are usually water pollutants and must not be allowed to escape into the environment Dispose of dismantled materials properly or recycle the separate materials Observe national disposal regulations Series 961 04.2017 / 1.0 17 / 18

www.arca-valve.com