Digi Connect ME 9210 Linux: 2 nd serial over FIM

Similar documents
Digi Connect ME 9210 Linux: serial port 2 for JTAG modules

Setting Up the Ingenico isc250 Pinpad via USB

Setting up the Ingenico isc250 Pinpad via USB in Windows 8

BASnet LightiView Install Guide

Oxygen Meter User Manual

IBU3 Manual Addendum 1

Drag racing system HL190 User Manual and installation guide

Product Overview. Product Description CHAPTER

215 Liquid Handler Up-Grade Manual

ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11

MASK INTEGRITY TEST ACCESSORY (MITA) MODEL 8120

Using the Lego NXT with Labview.

T i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)

Drag Racing Scoreboards

1. Hardware...2. Hardware Connection... Connection Diagram... DIP Switch Setting... & 0 PIN Button Layout...

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

D-Opto Dissolved Oxygen Sensor Operation Manual

1. Hardware Hardware Connection... 2 Connection Diagram... 3 DIP Switch Settings & 10 PIN Button Layout... 4

GMB HR84. GMM 518 Zero

INSTALLATION INSTRUCTIONS AND REFERENCE HANDBOOK

AN-140. Protege WX SALLIS Integration Application Note

Race Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock

APPLICATION NOTES. WIND MEASURING SYSTEMS using XDi-N indicators. Document no.: B

UG4: OPEN HAB. Elelabs ZigBee RPi Shield firmware version, referenced in this guide: OpenHab2 software version, referenced in this guide: v2.3.

Track and Field Interface

Stand-Alone Bubble Detection System

WELCOME TO THE REVOLUTION

Wickets Administrator

Instrument pucks. Copyright MBARI Michael Risi SIAM design review November 17, 2003

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

What to Expect at Your First FTC Tournament. Eric Grajales Mike Nicolai September 17, 2011

D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Connect with Confidence NO POWER NO PROBLEM

CNC Communication Protocol

1001ICT Introduction To Programming Lecture Notes

HyperSecureLink V6.0x User Guide

VOLAR PRODUCTION TRUCK SCOREBOARD CONTROLLER DATA INTEGRATION

SHIMADZU LC-10/20 PUMP

DIVE MEET SCORING INSTRUCTIONS. Day before meet

DST Host User Manual

SECTION 2 SMART PAYOUT MANUAL SET FIELD SERVICE MANUAL

1. Hardware Bookkeeping & Adjustment...7. Access Flow Chart... 7 System Adjustment... 8 Chance Adjustment... 9 Touch Screen Calibration...

Configuring Bidirectional Forwarding Detection for BGP

Please note. Right now, the ongoing version of emax (3.9C) is not already completely compatible with the newest firmware version of Shimano!

Mass Flow Controller (MFC) for Gases

XC2 Client/Server Installation & Configuration

TR Electronic Pressure Regulator. User s Manual

IPR208D - IPR215D IPR208D - IPR215D GB r docx IPR208D -IPR215D 1/99

1. Hardware Bookkeeping & Adjustment Access Flow Chart... 6 System Adjustment... 7 Chance Adjustment... 8 Touch Screen Calibration...

Pneumatic high-pressure controller Model CPC7000

Rescue Rover. Robotics Unit Lesson 1. Overview

Technical Bulletin, Communicating with Gas Chromatographs

Instruction Manual. BZ7002 Calibration Software BE

Operating Manual. SUPREMA Calibration. Software for Fire and Gas Warning Units. Order No.: /01. MSAsafety.com

OC508 Programmable mv Calibrator

PRODUCT MANUAL. Diver-Mobile for Android

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

SWIM MEET MANAGER 5.0 NEW FEATURES

Instruction Manual. Smartinterface serial

Diver-Office. Getting Started Guide. 2007, Schlumberger Water Services

D-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)

CONSOLE-320 ENGLISH. 230A: CONSOLE-320 with cable data output Item 230B: CONSOLE-320 with cable + wireless radio data output

Document Number: 239/34000/76 Revision: (-) 2009-Apr-13

Manual Weighingblock VB2 series and Uniscale

APPLICATION NOTE. OJ-DV Modbus protocol. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS E 03/18 (PDJ) 2018 OJ Electronics A/S

The examples below are a starting point, and some fine tuning may be required.

HART Communications Board

BGA244 Binary Gas Analyzer

Session Objectives. At the end of the session, the participants should: Understand advantages of BFD implementation on S9700

EZ Boom 2010 System for the EZ Guide 500 Lightbar Triangle Ag Services Users Guide

This document contains recommendations that may help teams be more successful in preparing for and participating in the FTC World Championship Event.

STAND alone & p.c. VERSION

TESLAGON. ShotHelper Manual. How to install and use the Program. Version /30/2014

DIY - PC - Interface for Suunto Cobra/Vyper/Mosquito

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases

Perfect Golf Quick Start Guide

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

OMNISPORT 2000 SWIMMING QUICK REFERENCE

RaceAmerica Corporation 105 Bonaventura Drive San Jose, CA (408)

SDI mA Pressure Transducer (Submersible + Dry) Model WL2100 Operating Manual

D-OptoLogger Dissolved Oxygen Logger Operation Manual

Edgecore ASFvOLT16 VOLTHA Adapter and Driver. Kim Kempf, Sr. Systems Architect CORD Build 2017, San Jose November 8, 2017 MT08.3.

GasSense NDIR User Manual

FOOD INTAKE MONITOR. Hardware and Software User s Manual DOC-047 Rev 3.0. Copyright 2009 All Rights Reserved

Upgrading Bio-Plex Manager 4.1, 5.0, or 6.0 Software to Bio-Plex Manager 6.1 Software

REMOTE CLIENT MANAGER HELP VERSION 1.0.2

GV Standard X-Vent. Setup, Commissioning & Installation Guide

CONSUMER MODEL INSTALLATION GUIDE

Mass Flow Controller (MFC) for Gases

AGW SYSTEMS. Blue Clock W38X

5) Match timer: Hanged on the court, display the match time synchronous with scoring system.

Gas Analyzer for TC Sensors (CO2, H2, N2) Series 62101, 64101, Operating Manual

Education and Research

PC Configuration software for Discovery MkVI v 1.03 User guide

OPERATION MANUAL DIVE CALIPER NOT SCALE / IF IN DOUBT ASK* *ALL UNITS IN MM/DEGREES UNLESS SPECIF. Dive Caliper General DC-051

SR-242 USER S GUIDE. Table of Contents

Airflow Options for Cisco MDS 9396S SAN Switch

RM-80 respiration monitor

Transcription:

Digi Connect ME 9210 Linux: 2 nd serial over FIM

Document History Date Version Change Description 09/04/2009 Initial entry/outline Table of Contents Document History... 2 Table of Contents... 2 1 Problem Description... 3 2 Requirements... 3 3 Software Setup... 3 4 Hardware Setup... 6 5 Testing... 7 Copyright 2009 Digi International Page 2/8

1 Problem Description The Digi Connect ME 9210 module without JTAG has only one serial line (port A of the NS9210 processer) connected. If you need a second serial line you can use the NS9210 internal FIM to drive some of the free GPIOs as serial line. Unfortunately the handshake lines of serial port A and the FIM pins overlap, such you can only drive two serial lines if you disable hardware handshake (TX/RX only). Click here for source files 2 Requirements To try the example in this document you need: Digi Connect ME 9210 module with Linux (DC-ME-Y402-LX). Digi Embedded Linux (DEL) 5.0 or above development environment. For DEL 5.0 you need to have installed the latest patches via the package manager. With DEL 5.1 it should work out of the box. Either the Digi Connect ME development board with additional TTL232 adapter (e.g. Digi FS-276), or your custom board. You can get everything together in a Digi Connect ME 9210 Linux JumpStart Kit: DC-ME-9210-LX 3 Software Setup Install Digi Embedded Linux (DEL) 5.0 or higher, apply latest patches with the Package Manager. Create a new Digi EL Kernel/Rootfs/U-Boot Project for Platform Digi Connect ME 9210, but select only Kernel, Kernel Modules, Root File System as project Copyright 2009 Digi International Page 3/8

components: Digi Customizing Platform Code In Digi Embedded Linux Configure the project (right click on the project an select configure) Copyright 2009 Digi International Page 4/8

Select Linux Kernel Configuration, Device Drivers, FIM drivers support, FIM0, Serial driver 2-wire (CONFIG_FIM_ZERO_SERIAL_RXTX): Select Digi Connect ME 9210 on Devboard in the Linux Kernel Configuration System Type. Enable Serial port A with RX/TX only (CONFIG_CME9210JS_SERIAL_PORTA_RXTX): Copyright 2009 Digi International Page 5/8

Select Device Drivers, Character devices, Serial drivers, Digi NS921x serial port support, Console on Digi NS921x serial (CONFIG_SERIAL_NS921X_CONSOLE): Build and install the project 4 Hardware Setup Turn off the development board. Connect the power cable. Plug Connect ME 9210 module to the development board. Connect Ethernet cable to Connect ME 9210 to your development PC (for updating firmware). Connect a serial null modem cable (pins 2 and 3 crossed) to your host computer (e.g. COMA is the CONSOLE). Plug the cable into Serial Port A of the Digi development board. Copyright 2009 Digi International Page 6/8

Connect a serial null modem cable (pins 2 and 3 crossed) to your host computer (e.g. COMB is the FIM_SERIAL). Plug the cable into a serial TTL converter like Digi FS-0276. Connect the serial TTL converter as following to the P3 (signal rail) of the Digi Connect ME development board: TTL converter pin 9 GND dev board P3 pin 16 TTL converter pin 10 VCC (+3.3V) dev board P3 pin 15 TTL converter pin 3 - RX - dev board P3 pin 12 TTL converter pin 5 - TX - dev board P3 pin 11 Set the devboard SW3 dip switches to IO2 (SW3:2) and IO3 (SW3:3) 5 Testing Run the new build kernel and rootfs on the Digi Connect ME 9210 module (e.g. update the images in flash build in section 3). Start a terminal program with 38400 8N1 on your development host on COM1 (console) and COM2 (serial FIM). Boot Linux on the Digi Connect ME 9210 module. On the serial console (COM1), configure the serial interface: # stty F /dev/ttyfim0 38400 Send some test string from the ConnectME 9210 serial FIM to the development host (COM2 serial FIM): Copyright 2009 Digi International Page 7/8

# echo Hello World >/dev/ttyfim0 Check if the test string is received by your terminal program on COM2. Send some test string from the development host via the serial FIM to the Digi Connect ME 9210. First start a program on the Connect ME 9210 which is able to receive the chars, e.g.: # cat /dev/ttyfim0 Enter some string on the COM2 serial FIM terminal program of your development host (press Enter, if everything is configured in line mode which is the default) and check if it is received on the Connect ME 9210 console. Copyright 2009 Digi International Page 8/8