Chapter 16 Test. Directions: Write the correct letter on the blank before each question.

Similar documents
Upon completion of this unit of study, the student should be able to: 1. Identify the term fire stream and the four purposes of a fire stream.

FIRE LOGISTICS AND MATH EDUCATION A Rumpke Public Outreach Program

Chapter 1 FF I Orientation and Fire Service History

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 14 Hydraulics Revised

Pumping Apparatus Driver/Operator Apparatus Testing. Chapter Test. Directions: Write the correct letter on the blank before each question.

Apparatus Operator Refresher Training Program

second test was conducted using at 3/4inch nozzle to determine a practical maximum pressure for the pump.

Ultra-High Pressure Firefighting: The Fastest Attack

Apparatus Operator/Pumper

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Essentials of Fire Fighting

TurboDraft Fire Eductor

INSTRUCT-O-GPAM THE HANDS-ON TRAINING GUIDE FOR THE FIRE INSTRUCTOR FIRE HOSE AND NOZZLES

Head to Head Demo Comparison Sheet

Application Worksheet

FIREGROUND HYDRAULICS

DISCLAIMER TSS is simply providing current information so you can make sound tactical decisions.

EMERGENCY WALL MOUNTED HAND OPERATED DELUGE SHOWER

Model SOP Standard Operating Procedure

Skill Sheet 17-I-2. Attack a structure fire above, below, and at ground level Interior attack. (NFPA 1001, , )

FIRE FIGHTER II - SKILLS PERFORMANCE SHEET

TurboDraft. Fire Eductor Operating Instructions.

Idaho Fire Service Technology Pumping Apparatus Driver/Operator Skill Sheet: 1

Des Plaines Fire Dept. Engineer Program

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

FIRE FIGHTER II SKILL PERFORMANCE CHECK SHEETS NFPA FIRE FIGHTER II SKILL STATION MENU

EDUCTOR. principle of operation

Introduction Volume & Area Based formulas Figure 1

Cozumel Turbodraft. Operational Considerations

Direct attack. 1 Introduction

Colorado Division of Fire Prevention & Control Driver Operator Pumper JPRs (NFPA 1002, 2014 Edition)

Nozzles and portable monitors

Irrigation System Winterization and Pressurization Procedures

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 24 Attack Hose Lays Revised

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Idaho Fire Service Technology Fire Fighter II

Chapter 3. Solids, Liquids, and Gases

Structural Firefighting Review: Fire Attack

Chapter 10 Product Control

Sizing Pulsation Dampeners Is Critical to Effectiveness

Applied Fluid Mechanics

Blue Points 1 ¼ WELL POINT INSTALLATION INSTRUCTIONS

FIRE FIGHTER II JPR: FFII-1A

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

Air Eliminators and Combination Air Eliminators Strainers

PRO SINK -R 1 and 2. Dilution system CONTENTS

SCENARIO 18 Leak on Intermodal Pressure Tank Container

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

HAZARDOUS MATERIALS OPERATIONS NFPA 472, 2008 Edition

The Discussion of this exercise covers the following points:

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Chapter 13 Temperature, Kinetic Theory, and the Gas Laws 497

Safety and operating instructions

Diagnosing EVAP systems By: Bernie Thompson

Pipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3

17 15 NOVA SCOTIA FIRE SERVICE TRAINING EXTERIOR LEVEL (PHASE 2)

INSTRUCTION MANUAL. Gas Salamander

2012 SYLLABUS FOR IFE LEVEL 2 CERTIFICATE FIRE SCIENCE, OPERATIONS AND SAFETY 500/5925/7.

Model 420-HY Pressure Regulating Hydrant Valve

EMERGENCY RESPONDER INFORMATION

WARNING: FOR OUTDOOR USE ONLY

Driver Releasal Manual

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212)

Driver Operator Pumps: Basic Pump Operations

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

Emergency Shower & Eyewash. Training Guide

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES

I. Subject: Compressed gas cylinders, regulators, and portable liquid systems.

Hotspotter. Model WB-100 Professional Series. Assembly, Testing & Operating Instructions. Safety Information:

Button style shirt and firefighting gloves are not required. (This will be a requirement in 2019.)

GEORGIA FIREFIGHTER STANDARDS AND TRAINING FIREFIGHTER PERFORMANCE EVALUATION & INSTRUCTIONS SHEET

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

E X T E R I O R L I V E P R O P A N E F I R E P R O P P R O C E D U R E S F O R U S I N G T H E P R O P A N E P R O P

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

Linde Hydraulics Corporation, P.O. Box 82, Canfield, Ohio 44406

Kansas State University Fume Hood Operation

ENGINE COMPANY OPERATIONS CHAPTER 12 February 15, 2006 WATER LOSS PROCEDURES

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

appendix a recommended rules For sizing the water supply system PRE-PRINT Chart a 1.2 FriCtion losses For Disk-type water Meters

Model: 43T. Bermad Pressure Relief Valve

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

Types ACE95 and ACE95Sr Tank Blanketing Valves

Adjustable. Unloader Valve. O&M Manual. Part #

CHAPTER 16 %UHDWKLQJ*DV0L[LQJ3URFHGXUHV

Lesson 6: Flow Control Valves

III. Identify the initial installation requirements for standpipe systems

Installation and commissioning instructions 255 series and 256 series

PRESSURE ADJUSTMENT Main pressure adjustment

Friction occurs when surfaces slide against each other.

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Varying pump capacity affects the required hoseline diameter

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

AWG Fittings LLC. Pressure Relief Valve Up to 250 PSI. Product Number Read this instruction manual before use.

Enabling Objectives (EO): EO Identify certain practices that could be considered unsafe and result in injury or death.

Transcription:

Chapter 16 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Explain the way vaporization and steam relate to the extinguishing properties of water. 1. Characteristics of water that make it valuable for fire extinguishment include: (944) A. low coefficient of friction. B. a single application method. C. a greater heat-absorbing capacity than other agents. D. an ability to change to steam with little energy required. 2. The primary way water extinguishes fire is by: (944) A. absorbing heat. B. excluding oxygen. C. saturating dry fuel. D. neutralizing the chemical reaction. 3. The energy required to raise the temperature of a substance by one degree is called: (944) A. Specific Heat. B. British Thermal Unit (Joule). C. Latent Heat of Vaporization. D. Standard International Heat Unit. 4. Latent Heat of Vaporization is: (944) A. the temperature at which a substance turns to steam. B. the temperature at which the rate of vaporization begins to decrease. C. the amount of heat required to raise the temperature of a substance by one degree. D. the amount of heat required to convert a unit mass of a liquid into a vapor without temperature change. 16-I-1

5. As water is vaporized into steam, it expands approximately its original volume. (944) A. 700 times B. 1,000 times C. 1,700 times D. 2,200 times 6. Which statement about water streams is MOST accurate? (946) A. Water in a solid stream absorbs heat more rapidly. B. A solid stream has greater surface area to absorb heat. C. A stream broken into small droplets has a greater surface area. D. A stream broken into small droplets absorbs heat less efficiently. 7. Which of the following statements about vaporization and steam is MOST accurate? (947) A. Steam produced in the upper layer of hot smoke and fire gases may cause the upper layer to expand downward. B. Steam produced on contact with hot surfaces is more likely to result in complete vaporization of the fire stream. C. Steam produced in the upper layer of hot smoke and fire gases will cause the upper layer to contract toward the ceiling. D. Steam produced on contact with hot surfaces has little effect on the total volume of the upper layer of hot smoke and fire gases. Objective 2: Identify the factors that create pressure loss or gain. 8. Which of the following statements about friction loss is MOST accurate? (948) A. Friction increases pressure at the nozzle. B. The larger the hose, the higher the friction loss. C. Friction has little effect on the rate of water flow. D. The longer the hose lay, the higher the friction loss. 9. The loss of water pressure in a hoseline is the most common example of: (948) A. breakover. B. friction loss. C. vaporization. D. water hammer. 16-I-2

10. Friction loss may be overcome by: (948) A. curving the hoseline. B. decreasing hose size. C. increasing pump pressure. D. inserting in-line gauges in the layout. 11. Which of the following statements about water pressure is MOST accurate? (948) A. Gravity has little effect on nozzle pressure. B. If the nozzle is above the fire pump, nozzle pressure is decreased. C. If the nozzle is below the fire pump, nozzle pressure is decreased. D. Adjusting pump pressure has little effect in overcoming elevation loss/gain. Objective 3: Describe the impact water hammer has on fire streams. 12. Which of the following statements about water hammer is MOST accurate? (949) A. The effects of water hammer are greater at lower flow rates. B. Water hammer is caused by air and turbulence in hose lines. C. Water hammer creates a startling noise, but no real damage. D. Water hammer can damage water mains, plumbing, fire hose, hydrants, and fire pumps. 13. To prevent water hammer: (949) A. use ball valve controls. B. bleed air from hoselines. C. flush debris from nozzles. D. close control valves slowly. 16-I-3

Objective 4: Explain fire stream patterns and their possible limiting factors. 14. A fire stream is a stream of water or extinguishing agent after it: (949) A. is fully vaporized by the heat of the fire. B. comes in contact with the desired target. C. is pressurized by the pump and passes into the fire hose. D. leaves the fire hose nozzle until it reaches the desired target. 15. Which of the following is a factor that may affect a fire stream? (949) A. Steam conversion rate B. Location of control zones C. Compartment temperature D. Wind direction and velocity 16. Which of the following BEST describes a use of a fire stream? (949-950) A. Scattering heavy weight fuel loads B. Dispersing hot smoke and fire gases from a heated area C. Creating a protective curtain between bystanders and fire personnel D. Pressure-washing soot and debris from apparatus and equipment 17. 18. Which of the following statements about fire streams is MOST accurate? (950) A. The type of nozzle determines the critical flow rate. B. The relief valve influences the reach of a fire stream. C. Hydrant pressure determines the shape of the fire stream. D. The size of the nozzle opening and the nozzle pressure determine the quantity of water flowing from the nozzle. Fire stream pattern types are defined by the specific pattern or shape of the water after it leaves the nozzle and the size of the: (950) A. type of apparatus generating the nozzle pressure. B. volume of water flowing from the nozzle per minute. C. water source that is used for the specific fire stream. D. specific type of fuel that the fire stream is being used on. 16-I-4

19. Which of the following BEST describes the rate of discharge of a lowvolume stream? (950) A. Less than 40 gpm (160 L/m) B. 40 to 350 gpm (160 L/m to 1 400 L/m) C. 100 to 250 gpm (380 L/m to 950 L/m) D. More than 350 gpm (1 400 L/min) 20. Which size fire stream flows 40 to 350 gpm (160 L/min to 1 400 L/min)? (950) A. Master stream B. Handline stream C. Low-volume stream D. High-volume stream 21. Which of the following hoseline sizes are used to supply a handline stream? (950) A. 1½- to 3-inch (38 mm to 77 mm) hoselines B. 2½- to 3-inch (65 mm to 77 mm) hoselines C. 3½ - to 5-inch (88 mm to 125 mm) hoselines D. ¾-inch (20 mm), 1-inch (25 mm), or 1½-inch (38 mm) hoselines 22. Which stream is created by apparatus-mounted appliances? (951) A. Master stream B. Handline stream C. Low-volume stream D. High-volume stream 23. To extinguish by cooling, the fire stream must: (951) A. be fully vaporized into steam. B. fully saturate the fuel source. C. absorb heat faster than fire generates heat. D. absorb over 50 percent of heat generated by the fire. 16-I-5

24. 25. 26. 27. 28. Which of the following statements about fire stream types is MOST accurate? (951) A. The pattern type must be correctly matched to the pattern size. B. The pattern must supply at least 50 percent of the critical flow rate. C. The pattern must be compact enough for the water to reach the burning material. D. The pattern must maintain its shape at least 50 percent of the reach of the fire stream. Which fire stream pattern is produced by a fixed orifice, smooth bore nozzle? (951) A. Fog-stream B. Solid stream C. Broken-stream D. Straight stream Which nozzle produces a compact stream with little shower or spray? (951) A. Cellar nozzle B. Piercing nozzle C. Smooth bore nozzle D. Constant gallonage fog nozzle How may gravity, friction of air, and wind act on a solid fire stream? (951) A. They may alter the rate of vaporization. B. They may decrease the reach of the stream. C. They may make the stream more conductive to electricity. D. They may cause the steam to remain compact for too long. Which of the following fire stream patterns produces less steam conversion and less heat absorption per gallon (liter)? (951) A. Fog-stream B. Solid stream C. Broken-stream D. Straight stream 16-I-6

29. 30. Which of the following statements about fire streams is MOST accurate? (951) A. Solid streams are more likely to conduct electricity. B. Fog-streams are less affected by wind than are solid streams. C. Broken-streams have less reach and penetration than fogstreams. D. Wide angle fog patterns have the greater forward velocity than other patterns. Additional personnel will be required to safely handle smooth bore nozzles at nozzle pressures greater than: (954) A. 50 psi (350 kpa). B. 65 psi (450 kpa). C. 75 psi (525 kpa). D. 100 psi (700 kpa). 31. Which of the following BEST describes a fog-stream? (954) A. A semi-solid stream B. A compact stream with little shower or spray C. A fine spray composed of tiny water droplets D. A fire stream broken into coarsely divided droplets 32. 33. Which of the following fire stream patterns can be used for hydraulic ventilation? (954) A. Fog-stream B. Solid stream C. Broken-stream D. Straight stream Which of the following statements about fog-streams is MOST accurate? (955) A. Fog-streams may be used to cool the hot fire gas layer. B. Fog-streams have the greatest reach of all fire streams. C. Fog-streams are less affected by wind than are other streams. D. Fog-steams have greater reach and penetration than brokenstreams. 16-I-7

34. 35. Which of the following fire stream patterns is usually produced by a fog nozzle? (955) A. Solid stream B. Cellar stream C. Broken-stream D. Straight stream Which of the following stream patterns is used to extinguish fires in attics, cocklofts, basements, and other confined spaces? (955) A. Solid stream B. Cellar stream C. Broken-stream D. Straight stream 36. Which statement about broken-streams is MOST accurate? (956) A. A broken-stream has less reach and penetration than a fogstream. B. Broken-streams may have sufficient continuity to conduct electricity. C. The effects of a broken-stream cannot be created by another stream type. D. Coarse droplets absorb less heat per gallon (liter) than a solid stream does. 37. 38. Which statement about fire stream limiting factors is MOST accurate? (956) A. Gravity causes fire streams to separate and lose shape. B. Surface tension can cause fire streams to overshoot the target. C. Friction with air has greater effect on solid streams than on fogstreams. D. Fire streams have an effective forward velocity of 40 to 60 feet per second (12.2 to 18.3 meters per second). In actual operation, fire stream angles between provide maximum reach. (956) A. 15 to 19 degrees B. 20 to 24 degrees C. 30 to 34 degrees D. 45 to 49 degrees 16-I-8

Objective 5: Describe the three types of fire stream nozzles. 39. 40. 41. 42. 43. Which of the following nozzle categories was established by NFPA 1963, Standard for Fire Hose Connections? (957) A. Bresnan B. Piercing C. Rockwood D. Straight tip Which of the following statements about fire steam nozzles is most accurate? (957) A. Fog nozzles do little to shape the fire stream. B. Smooth bore and fog nozzles are used only on handlines. C. Broken-stream delivery devices are used to apply water in confined spaces. D. Smooth bore nozzles are designed to give water a fan shape before discharge. Which of the following statements about smooth bore nozzles is MOST accurate? (958) A. Smooth bore nozzles operate at high nozzle pressures. B. Smooth bore nozzles are very prone to clogging with debris. C. Hoselines may kink as smooth bore nozzles use less pressure. D. Smooth bore nozzles may be adjusted, resulting in different patterns. Which of the following statements about fog nozzles is MOST accurate? (959) A. Fog nozzles cannot be used to apply foam. B. Fog nozzles must be turned off before flow can be adjusted. C. Fog nozzles do not allow selection of different stream patterns. D. Fog nozzles can provide protection to firefighters with a wide fog pattern. Which of the following types of fog nozzles provides a constant discharge rate throughout a range of patterns? (959) A. Basic B. Constant pressure C. Constant gallonage D. Constant/select gallonage 16-I-9

44. 45. 46. 47. Which statement about constant-pressure fog nozzles is MOST accurate? (961) A. The operator can vary the flow rate while maintaining constant nozzle pressure. B. The operator can vary flow rate but must also change the nozzle pressure. C. Constant-pressure fog nozzles for handlines are only designed for low-flow rates. D. Constant-pressure fog nozzles are reliable when the operating pressure is less than 100 psi (700 kpa). Which of the following is a characteristic of nozzles designed to operate at pressures less than 100 psi (700 kpa)? (961) A. Have more nozzle reaction B. Produce droplets of smaller size C. Produce lower-density fog patterns D. Produce fire streams with greater velocity Which type of nozzle can be used to effectively control fires in concealed spaces? (962) A. Piercing B. Stacked tip C. Smooth bore D. Adjustable fog (xx) Which of the following statements about cellar nozzles is MOST accurate? (962) A. Cellar nozzle standards are established by NFPA 1963. B. Cellar nozzles can be used to apply compressed air foam. C. Cellar nozzles are driven into place with a mallet, sledge hammer, or flathead axe. D. Cellar nozzles are lowered into confined spaces through a hole cut in an overhead surface. 16-I-10

Objective 6: Compare the different types of nozzle control valves. 48. 49. 50. When used with a smooth bore nozzle, a nozzle control valve that causes turbulence when partially open which can affect the quality of a fire stream is the: (963) A. ball valve. B. slide valve. C. standpipe valve. D. rotary control valve. Which of the following nozzle control valves also controls the discharge pattern of the fire stream? (963) A. Ball valve B. Slide valve C. Standpipe valve D. Rotary control valve Which of the following statements about slide valves is MOST accurate? (963) A. Slide valves permit water to flow without creating turbulence. B. Slide valves use an exterior barrel guided by a screw and sliding along an interior barrel. C. Slide valves control both the flow of water and the discharge pattern of the fire stream. D. Slide valves use a ball with a smooth waterway that rotates 90 degrees to control the flow of water. Objective 7: Describe the factors in operating and maintaining handline nozzles. 51. Which of the following statements about smooth bore nozzle reaction is MOST accurate? (964) A. Lean backward to control nozzle as action increases. B. Nozzle valves should be opened slowly to minimize water hammer. C. Increasing discharge pressure and flow rate increases nozzle reaction. D. Additional personnel are required for operating smooth bore nozzles on all hoselines. 16-I-11

52. 53. Which of the following statements about operating fog nozzles on handlines is MOST accurate? (966) A. Fog nozzle flow rates may be adjusted quickly with no nozzle reaction. B. Adjustable fog nozzles must be turned off for the operator to adjust the flow. C. As the fog pattern widens, the nozzle reaction decreases and the nozzle is easier to handle. D. Fog nozzles are more difficult to handle than smooth bore nozzles. Which of the following statements about maintaining nozzles is MOST accurate? (966) A. Nozzles should be inspected after each use, and at least weekly. B. Nozzles should be stored with the control bale in the open position. C. Nozzles should be thoroughly cleaned once per year with soap, water, and a soft bristle brush. D. Maintenance, care and cleaning should be performed according to manufacturer s recommendations. 16-I-12