OXY-VIVA 3 RESUSCITATOR OPERATING INSTRUCTIONS

Similar documents
SERIES-O REGULATOR. Instructions for use

Pressure Regulator. Instructions for Use

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% USER ADMINISTRATION SYSTEM 01EQ7000E DEMAND VALVE 01EQ7001E TABLE OF CONTENTS

SUCTION Attachments 7 Suction Regulators 10 Accessory Products 11. EMERGENCY RESUSCITATION Oxy-Viva 3 12 R-Viva 13 Demand Valves & Masks 15

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

2 PRE USE FUNCTION CHECK 3 OPERATING PROCEDURE 4 SERVICING. 5 CAREvent ALS ACCESSORIES 11

Pressure Regulators. Instructions for Use

Dialflow Regulator. Instructions for Use

CPR MEDICAL DEVICES INC. OPERATING MANUAL FOR RESUSCITATOR

Rev. B. Operating Instructions

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

CPR MEDICAL DEVICES INC. OPERATING MANUAL

OXY-life TM. Oxygen Resuscitator OPERATING MANUAL

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

Oxygen Dialflow Meter. Instructions for Use

CLEMENTS. ANA Oxygen Regulator with Yoke Connector. User Manual. Manual No. ANA Issue 1

AUTOVENT 4000 VENTILATOR

Presence PR, PRC & PRE

Equinox II NITROUS OXIDE / OXYGEN ADMINISTRATION EQUIPMENT 01EQ7000E

Breathing Devices. Chapter 8 KNOWLEDGE OBJECTIVES SKILL OBJECTIVES. 6. List four precautions to take when using oxygen.

Micro Dial-Flowmeter. Instructions for Use

OXI-sok 2 OXYGEN RESUSCITATION KIT OPERATING MANUAL. Oxygen bottle not included

Oxygen Dialflow Meter. Instructions for Use

OXI-dive 3 OXYGEN RESUSCITATION UNIT OPERATING MANUAL

Oxygen Demand Valve. Instructions for Use

Training. Testor Training Manual

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

USER MANUAL (For G2005 Model)

Peninsula Dental Social Enterprise (PDSE)

SERVICE KITS AND CALIBRATION NOTES

Complex Care Hub Manual: Oxygen Therapy

User manual. ZX trolley.

Yoke Block Instruction Manual

RB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23

80 Litre Suction Oil Drainer

O-Two Self-Study Guide. Equinox Relieve

Operation and Maintenance Manual for GENTEC Model 881VR Continuous/Intermittent Digital Suction Regulators

Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL

AIR HAMMERS MODEL NO: CAT138/CAT139 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: / GC064

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

C-1 C-7. C-6 Short air tubing Upper Velcro straps. C-a C-5 C-2 C-4 C-3 B-1 B-9 B-10 B-2 B-7 B-8 B-3 B-6 D-1 D-2 D-13 D-3 D-12 D-10 D-11 D-4 D-5 D-8

Operation and Maintenance of the EPV200 Portable Ventilator

User Instruction Manual

VERTICAL AIR COMPRESSORS

Operation and Maintenance of the MCV100 and MCV100-B Portable Ventilator

MANUAL GAS MANIFOLDS

NeoNatalie Resuscitator Oxygen kit

CONTROL MODULE FOR RESUSCITATOR

Hallowell EMC 2000 and 2002 Veterinary Ventilator Set-up, Use, and Troubleshooting

PRESSURISED PAINT CONTAINER

RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL

Mirage Vista Nasal Mask

Instruction Manual Updated 7/26/2011 Ver. 2.2

Code AWC20HP Air Compressor

45A, Armthorpe Road, Brampton, Ontario, Canada, L6T 5M4. Made in Canada by O-Two Medical Technologies Inc.

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

NeoNatalie Resuscitator Oxygen kit

5 Gallon Pressure Pot with HVLP Spray Gun and Hose

Oxygen Therapy Devices

Testing anaesthetic machines, ventilators and related equipment

Yoke Block Instruction Manual

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

Paradise Pump Series Operator s Manual

Operation Manual Air Saver Unit ASV5000 Series

Product Information News September 26, 2003

RhinoPro Cartridge Gun Manual

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

SCK01 AIR COMPRESSOR KIT WITH QUICK FITTINGS - SPRAY/BLOW/OIL GUN, TYRE INFLATOR & HOSE

VERTICAL AIR COMPRESSORS

Service and Repair Manual

Tracheostomy and Ventilator Education Program Module 11: Emergency Preparedness

BOC: Living healthcare. Manual. LIV IQ BOC Integrated Valve with digital display portable delivery system for Medical Oxygen. BOC: Living healthcare

Analgesic Demand Valve. Instructions for Use

PO Box 370 Phone: Swansea NSW 2281 Fax: AUSTRALIA Mobile: Web:

Operators Manual. Supera Floor Stand Anesthesia Machine M1000. Models: M1000 Basic Non-rebreathing M1200 Basic M1200

USER MANUAL AUTOMATIC AND MANUALLY TRIGGERED RESUSCITATOR. O-TWO MEDICAL TECHNOLOGIES INC. Innovation in Resuscitation

OPERATING AND MAINTENANCE MANUAL

V-24 OXYGEN LANCE VALVE

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

50L ENGINE DRIVEN AIR COMPRESSOR MODEL NO: XPPV11 & XPP15 RANGE

Oxygen Delivery Systems:

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Instructions for use Compressed air injector with water trap

Technical Operating Instructions for Magnum Cutting Systems. for online instructions

Unit 15 Manual Resuscitators

OPERATION MANUAL NTF-60 Plus

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

ATI Skills Modules Checklist for Oxygen Therapy

AUTOMATIC GAS MANIFOLDS

Product Information News

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

CleanAIR ARES CA-83. welding leather hood. Contents. 1 General information 2 Use 3 Technical specification 4 Maintenance 5 List of parts 6 Approvals

PC7-C Flowmeter O2/N2O Sedation Unit Instruction Manual

OXY FUEL SYSTEM SET UP & SHUT DOWN PROCEDURE CHECKLIST ACETYLENE FUEL GAS

WW-730. Pressure Sustaining/Relief Control Valve

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

MMR Air Mask With. with Quick-Connect Hose

EasyFit Lite Nasal Mask, Silicone. Nasal Mask. EasyFit Lite Nasal Mask. Device Description and Instructions for Use. Caution:

Dash8 - Q400 - Oxygen

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Transcription:

OXY-VIVA 3 RESUSCITATOR OPERATING INSTRUCTIONS COMWELD MEDICAL

TABLE OF CONTENTS 1.0 INTRODUCTION 3 2.0 GENERAL DESCRIPTION 3 3.0 SAFETY PRECAUTIONS 3 4.0 PARTS IDENTIFICATION 4 5.0 OPERATIONAL CHECK-OUT 5 6.0 EQUIPMENT USE 5 7.0 CLEANING 8 8.0 EQUIPMENT TESTING 9 9.0 SPARES AND ACCESSORIES 10 10.0 SPECIFICATIONS 11 11.0 SERVICE RECOMMENDATIONS 12 12.0 NOTES 13 2

1.0 INTRODUCTION This manual is intended to provide the users with information on the features, testing, use and care of an OXY-VIVA 3 resuscitator. Any potential users of an OXY-VIVA 3 should carefully read the contents of this manual to ensure that they are fully conversant with all the information on its testing, use and care before attempting to use the resuscitator. Resuscitation using an OXY-VIVA 3, or any other type of resuscitator, should only be attempted after the operator has completed a recognised course of study and practised regularly on a resuscitation manikin. The information contained in this manual should not be considered an adequate training program in resuscitation. Information concerning resuscitation in Australia is available from: Australian Red Cross National Heart Foundation The Royal Lifesaving Society of Australia St John Ambulance Surf Life Saving Associations Water Safety Councils Ambulance Services 2.0 GENERAL DESCRIPTION The information in this manual covers the OXY-VIVA 3 rescuscitator P/N 552090, and P/N s 517859 and 517621 when modified with upgrade kit P/N 552081. The main features of the OXY-VIVA 3 are a gas powered demand resuscitator, a suction attachment with collection jar, a fixed flow oxygen therapy attachment and an auxiliary inlet/outlet. It also contains adult and child resuscitation masks, adult and child therapy masks, airways, therapy tubing, suction tubing and a suction catheter. 3.0 SAFETY PRECAUTIONS Resuscitation should only be undertaken by persons who have received adequate training. The resuscitator should only be used if the assembly and all its components are in correct operating condition as described in the manual. An OXY-VIVA 3 resusctitator operates using oxygen. When using the resuscitator the following precautions should be observed: - No smoking, naked flames or sources of ignition nearby. - Use no oil or greases as a fire or explosion may result - Open cylinder valves slowly and fully. - Turn off cylinder valve when not in use. - Keep gas cylinders cool. - Do not dump or drop cylinders. The suction unit uses oxygen. Prolonged use may deplete the oxygen supply. All repairs should be undertaken only by personnel trained in the servicing procedures for medical equipment. Use only manufacturer approved spare parts when servicing. An OXY-VIVA resuscitator is not suitable for use in hazardous or explosive atmospheres.toxic gases may be entrained into the patient s lungs causing patient harm. 3

4.0 PARTS IDENTIFICATION Store suction tubing by winding around knobs. Storage sheath for suction catheter. Brief operating instructions. Cylinder contents gauge. Inlet-outlet for oxygen at 400kPa (hidden). Cylinder keywheel. Yoke connection,bodok seal yoke wing screw. Demand Resuscitator. Adult resuscitation mask. Collection jar for suction system. On-off control for suction. On-off control for oxygen therapy. Suction tubing. Oxygen therapy tubing. Oxygen therapy mask. Oxygen therapy mask. Child resuscitation mask. Guedel airways. Suction handpiece. 4

5.0 OPERATIONAL CHECK-OUT It is recommended that the OXY-VIVA 3 undergo the following simple functional tests to ensure that the unit is in readiness for use in an emergency. In addition to these tests the OXY-VIVA 3 should be placed on a preventative maintenance schedule which should include the tests detailed in section 8 of this manual. 1 Tighten the oxygen cylinder in the yoke, making sure that the Bodok seal is in good condition and is in position (see 6.1, Cylinder Supply). Turn on the oxygen cylinder valve (anticlockwise) to ensure that no leaks exist (see 8.1) and that adequate contents are registered on the gauge. 2. The suction trap jar must be located in the housing provided, and connected to the venturi outlet. 3. Check that the suction, attachment operates by turning the SUCTION control ON, and confirm that suction is generated at the suction outlet of the trap jar. 4. Ensure that the Demand Resuscitator functions when the cylinder valve is open and the actuating button is pressed. When released, the plunger must return fully to the OFF position and completely shut off the gas flow. Block off the mask connection on the Demand Resuscitator and press the manual ventilation button.the pressure relief valve should open and gas should be heard venting to the atmosphere. 5. Check that the oxygen therapy attachment functions by turning the THERAPY control ON and confirm that gas flows. 6. Check that both airways are present and held securely in their clips. 7. Check that the cylinder keywheel and yoke plug are securely attached to the case by their chains. 5 8. Check the condition of the resuscitation masks. Ensure that they fit the Demand Resuscitator, that they are free from damage, and the cuffs are soft and pliable. 9. Turn off the cylinder valve (clockwise) and place the keywheel in the case. Depressurise the unit by turning on the therapy flow control until the flow stops. Turn off the therapy flow control. The lid can now be closed and the OXY-VIVA is ready for immediate application should an emergency arise. 6.0 EQUIPMENT USE 6.1 Oxygen Supply The OXY-VIVA 3 has two oxygen supply inlets, a pin indexed yoke inlet for connection to oxygen cylinders and an auxiliary inlet/outlet sleeve indexed system (SIS) inlet for connection to a regulated 400 kpa external supply source. Cylinder Supply To fit a C size cylinder to an OXY-VIVA 3 first check that the Bodok seal is fitted to the pin indexed yoke connection and that the yoke wing screw is backed off. Remove any protective cover on the cylinder valve outlet. Crack the cylinder by briefly opening then closing the cylinder valve. Slide the cylinder into the frame at the base of the case. Locate the pin index holes on the cylinder valve with the corresponding pins on the yoke. Secure the cylinder valve in position by tightening the yoke wing screw. Fit the keywheel to the cylinder valve and slowly open (anticlockwise). Ensure that the cylinder valve has made a leaktight seal and the cylinder pressure registers on the contents gauge. Close the cylinder valve and release pressure from the unit by turning ON therapy flow control until the pressure gauge

reads zero. Turn OFF therapy flow control. Leave cylinder fitted and turned off until it is required for use. Auxiliary Inlet/Outlet Supply This inlet allows the OXY-VIVA 3 to be used in a fixed location when a regulated external supply of oxygen is available, thus leaving the cylinder supply for use when portability is required. To connect to a regulated supply,the pin indexed yoke must be blocked off. This can be done by closing the cylinder valve, or by using a blanking plug secured in the pin indexed yoke. A length of oxygen hose with sleeve indexed hand wheels can be used to connect the OXY-VIVA 3 to the regulated supply source (connect the OXY-VIVA 3 end first, then the regulated supply end to prevent whipping of hose). 6.2 Demand Resuscitator - General Description With the oxygen supply turned on, there will be no flow from the Demand Resuscitator until either the manual ventilation button is depressed or the patient inhales. A very slight inhalation effort produces an oxygen flow. The oxygen flow varies according to the inhalation effort and stops flowing during exhalation. An integral part of the Demand Resuscitator is an exhalation or non-rebreathing diaphragm and patient valve which allows gases from the lungs to be expelled during exhalation. To resuscitate a non-breathing patient the Demand Resuscitator has been designed to supply oxygen to the patient s lungs by means of a mask or endotracheal tube. When the manual ventilation button is depressed, oxygen will flow and inflate the lungs. When the manual ventilation button is released the gases are passively expelled from the lungs via the exhalation diaphragm and patient valve. USE ON A NON BREATHING PATIENT 1. Turn on the oxygen cylinder valve The keywheel is located inside the case. Turn anticlockwise. Open the valve slowly and fully. Check the contents gauge for adequate supply. 2. Clear the patient s mouth and throat, use suction if required. Insert airway if necessary. 3. Tilt the head back, lift jaw. Place support under shoulders if necessary. 4. Attach the mask to the Demand Resuscitator. Select the child or adult size mask as necessary. 5. Apply the mask firmly to the patient s face. Maintain an airtight seal over the nose and mouth. 6. Press the manual ventilation button on the Demand Resuscitator until the chest rises - then release. Wait until the lungs deflate, then repeat the operation continuously. 7. When the patient begins to breathe, stop pressing the manual ventilation button. Keep the mask on the face. The patient will automatically receive 100% oxygen with each breath on demand. CAUTION: Hazards of Overinflation. Overinflation of the lungs can occur if an excessive tidal volume is delivered, particularly in the case of children and when an endotracheal tube is in place. Inflation of the stomach can occur if an excessive tidal volume is delivered or if inflation is performed in the presence of a partially obstructed airway. If the stomach becomes distended, check the airway again but do not try to empty the stomach. 6

USE ON A BREATHING PATIENT Turn on the oxygen cylinder valve. The keywheel is located inside the case. Turn anti clockwise. Open the valve slowly and fully. Check the contents gauge for adequate supply. Attach the child or adult mask to the Demand Resuscitator Apply the mask firmly over the nose and mouth ensuring an airtight seal.when the patient breathes, the resuscitator will automatically supply 100% oxygen. If breathing stops,immediately proceed from Step under Patient not breathing. NOTE The demand Resuscitator, when delivering a tidal volume of 600 ml, 12 times a minute to a patient, would deplete a C size cylinder (contents approximately 400 litres) in approximately 45 minutes. 6.3 SUCTION ATTACHMENT To ensure clear airways before or during resuscitation, suction may be applied via the flexible suction tubing and catheter or handpiece when necessary. 1. Ensure that the suction collection jar is connected to the suction venturi under the ON/OFF lever. 2. Connect the suction tubing to the collection jar. 3. Fit the suction handpiece or catheter to the suction tubing. 4. Turn the Suction control to ON. This produces a continuous vacuum in the plastic reservoir jar and enables blood and other fluids to be sucked from airways. 5. If necessary, empty the reservoir jar during use to prevent overfilling. Important Turn suction OFF after use to prevent oxygen cylinder depletion. Trouble Shooting When suction is turned on, there is no aspiration of fluids. 1. Check that the jar is tight. 2. Check that there is no blockage in the suction tubing. NOTE Operation of the suction attachment uses oxygen. When suction is in use the suction attachment would empty a full C size cylinder (approximate contents 400 litres) in approximately 8 minutes. 6.4 THERAPY ATTACHMENT When necessary oxygen therapy can be used. To use the oxygen therapy attachment: 1. Connect one end of the therapy tubing to the therapy outlet under the ON/OFF lever. 2. Connect the other end of the therapy tubing to the therapy mask. 3. Turn the Therapy control to ON. 4. Fit the therapy mask to the patient s face and form an effective seal. The elastic bands should pass just above and below the ears and the soft metal strip should be bent over the nose to form a seal. 5. The oxygen concentration delivered to the patient depends on the particular mask used, see specification section of manual. 7

6 Turn therapy OFF when finished. If a variable flow is required,a flowmeter may be attached to the auxiliary inlet/outlet connection on the outside of the case. 7.0 CLEANING The OXY-VIVA 3 and its accessories must be thoroughly cleaned after each use. When cleaning use only legally marketed commercially available disinfectants or sterilising agents. Disinfectants and sterilising agents must only be used in accordance with their manufacturers instructions. The recommend cleaning method for various OXY-VIVA 3 accessories is listed below: 7.1 Case The OXY-VIVA 3 case may be cleaned using a mild soap solution, methylated spirits or a disinfectant. 7.2 Demand Resuscitator Operate the Manual Ventilation Button to blow out any loose contaminant. Ensure that the oxygen supply is turned off. Bleed the remaining pressure out of the system by depressing the Manual Ventilation Button. Remove any mask fitted to the Demand Resuscitator and disconnect it from the supply hose. Unscrew the mask connector from the Demand Resuscitator body. Remove the exhalation disc from the mask connector. All components, except the body, can be cleaned using a mild soap solution, disinfectant, autoclaving or ethylene oxide gas. The resuscitator body should only be wiped over with a soft cloth and a mild soap solution. After cleaning dry all components thoroughly. Re-assemble the exhalation disc to the mask connector. The exhalation disc must be centralised and it should freely rotate when lightly moved with a finger. Insert the diaphragm into the body of the resuscitator and smooth it into position with a finger. Place the mask connector diaphragm and screw it hand tight in a clockwise direction onto the body. Check the operation of the Demand Resuscitator as per section 5 of this manual. Resuscitator Body Manual Ventilation Button Diaphragm Mask Connector Exhalation Disc 8

7.3 Suction Jar, Suction Handpiece and Tubing The suction trap jar and tubing can be cleaned by drawing soap water,or a disinfectant through them or by autoclaving. If a mild soap solution is used, flush with clear water after cleaning to remove any solution. 7.4 Resuscitation Masks The adult and child resuscitation masks supplied with an OXY- VIVA 3 may be cleaned with a mild soap solution or disinfectant. They are NOT suitable for autoclaving or ethylene oxide gas. 7.5 Therapy Masks The therapy masks supplied with an OXY-VIVA 3 are for single use only. They must not be cleaned and re-used. 7.6 Orophharyngeal Airways The airways supplied with an OXY-VIVA 3 are for single use only. They must not be cleaned and re-used. 8.0 EQUIPMENT TESTING 8.1 Leak Test 1. Fit a full (10,000 kpa minimum) oxygen cylinder to the unit. 2. Open the cylinder valve to pressurise the piping system and note the regulator gauge reading. 3. Firmly close the cylinder valve, wait three minutes then note the regulator gauge reading again. 4. The maximum permissible leak is 2 widths of the gauge pointer. 8.2 Therapy Flow Test 1. Turn the cylinder valve fully ON. 2. Connect a suitable oxygen rotameter to the therapy outlet and turn the therapy valve ON. 3. The reading on the rotameter should be 7 to 9 litres per minute. 8.3 Suction Test 1. Ensure that the cylinder valve is turned fully ON. 2. Connect a suitable vacuum gauge to the suction hose so that the hose is occluded. 3. Turn the suction valve fully ON then take the reading on the gauge. This reading should indicate a suction level of -60 kpa minimum, (450 mmhg). 4. Check that the suction unit displaces 300 ml of water in about 2 seconds. Check that the edge of the plastic jar is not chipped and that the sealing gasket is sound. Check that the suction tubing is not blocked and the filter, adjacent to the control block, is clean. 9

8.4 Demand Resuscitation Test 1. Ensure that the cylinder valve is turned fully ON. 2. Connect a suitable oxygen rotameter to the Demand Resuscitator mask connection. 3. Depress the Demand Resuscitator operation button. 4. The flow reading should be 40 to 60 litres per minute. 5. Connect a suitable pressure measuring device to the mask connection. 6. Depress the manual ventilation button. 7. The pressure generated should be 54 to 60cm H 2 0. The Demand Resuscitator is not designed for field disassembly or service outside that indicated in this manual. Any malfunctioning units should be returned to an authorised repairer. Unauthorised repairs will nullify the product warranty. 9.0 SPARES AND ACCESSORIES 9.1 OXY-VIVA 3 Accessories Listed below are some of the accessories suitable for use with an OXY-VIVA 3. It is recommended that if any other accessories are intended to be used with an OXY-VIVA 3 your nearest authorised distributor should be contacted to check the compatibility of the accessory. Description Part No EZI-FLOW 0-15L/min flowmeter 515800 EZI-FLOW 0-2.5L/min flowmeter 515824 Gauge type 0-14L/min flowmeter TM17 O-TWO Demand Resuscitator upgrade kit for OXY-VIVA 3 (Part Number 517859) 552081 9.2 User Replacement Parts Listed below are the items that are considered to be user replaceable parts. It is recommended that the owner keep stock of items like Bodok seals, airways, therapy masks,...etc to ensure that the OXY-VIVA 3 is quickly replenished after any items are used. Description Part No Bodok Seal, 10 pack 551022 Inlet filter RB38, 10 pack 551024 Inlet filter/retainer, 10 pack 551028 Adult resuscitation mask - size 5 515743 Child resuscitation mask - size 3 515744 Demand Resuscitator diaphragm 552082 Demand Resuscitator mask connector 552083 (with exhalation disc) 10

10.0 SPECIFICATIONS Part Numbers 552090 OXY-VIVA 3 Demand Resuscitator 517859 OXY-VIVA 3 Demand Valve Model with upgrade kit 552081 fitted 517621 OXY-VIVA 3 RM Resuscitator with upgrade kit 552081 fitted Weight Each model weighs 6.5kg without a cylinder fitted, (approximately 10 kg with a cylinder fitted). Dimensions Each model 570 x 180 x 295 mm Cylinder Compatibility The OXY-VIVA 3 is compatible with all C size cylinders fitted with pin indexed cylinder valves. Gas Inlets 1. Cylinder Connection: Pin indexed high pressure oxygen yoke inlet to AS 2473.3 Demand Resuscitation Supply Pressure: 400k kpa nominal Resuscitation Flowrate: 40-60 L/min Demand Flowrate: 0-160 L/min Demand Triggering Pressure: 0.2 kpa (2cm H 2 0) max Negative Pressure: 0.8 kpa (8cm H 2 0) max (for a flow of 100 L/min) Pressure Relief Valve: 54-60cm H 2 0, available Delivered Oxygen Concentration: 100% during both Manual and Demand modes Patient Connection: 22mm Male/15mm Female Taper Inlet Connection: 9/16 DISS Suction Attachment Control Operation: Static Vacuum: Suction Flow: Suction Jar Capacity: Suction Connection: Suction Tubing: Suction Handpiece: ON/OFF lever -60 kpa (-450 mmhg) 40 L/min free air minimum 350 ml separate trap jar to suit standard 8mm tubing 1.5 metres of 8mm suction tubing Yankuer suction tip 2. auxiliary Inlet/Outlet: Sleeve indexed low pressure oxygen connection to AS2896, nominal 400kPa). Maximum Inlet Pressure Pin indexed yoke connection 20,000 kpa @ 15 o C. Therapy Flow Attachment Control Operation: Flowrate: Connection: Therapy Tubing: ON/OFF Lever 8 L/min fixed to suit standard 5mm tubing 2 metres of 5mm therapy tubing NOTE When the therapy mask supplied with the OXY-VIVA 3 is used, a fixed flow of 8 L/min will give a delivered oxygen concentration of approximately 60%. 11

11.0 SERVICE RECOMMENDATIONS An OXY-VIVA 3 is a piece of life saving emergency equipment. To ensure that the unit is always in a reliable, useable condition it is recommended that the unit be placed on a preventative maintenance program every 3 to 6 months depending on usage. The preventative maintenance program should include the test detailed in section 8. In addition to these tests the inlet filter and Bodok seal should be replaced annually, and the regulator seat be replaced every three years. Maintenance servicing of the OXY-VIVA 3 should only be carried out by trained service personnel. Contact your nearest authorised service agent for further information. 12

12.0 NOTES 13

14

15

COMWELD MEDICAL CIGWELD Pty. Ltd. A.B.N. 56 007 226 815 71 Gower Street, Preston, Victoria, Australia 3072 Customer Service & Technical Support Line Ph: +61 3 9474 7314 Fax: +61 3 9474 7391 Website: www.cigweld.com.au In the interest of continuous improvement, CIGWELD Pty. Ltd. reserves the right to change the specifications or design of any of its products without prior notice. PART NO. ISSUE DATE 522392 02 706