ISO INTERNATIONAL STANDARD. Gas cylinders Cylinder valves with integrated pressure regulators Specification and type testing

Oxygen Dialflow Meter. Instructions for Use

MEDAP-MOBILE GAS SUPPLY

OXYGEN THERAPY FLOWMETERS, REUSABLE AND SINGLE-PATIENT HUMIDIFIERS, PRESSURE REGULATORS, FLOW SELECTORS

Presence PR, PRC & PRE

MEDICAL REGULATOR RANGE (MEDIREG RANGE)

Micro Dial-Flowmeter. Instructions for Use

TITAN Oxygen Regulators

Oxygen Dialflow Meter. Instructions for Use

PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES

Wheel operated Residual Pressure Valves

OxyTOTE PORTABLE OXYGEN SYSTEM

REFERENCE GUIDE ON MEDICINAL GAS CYLINDER VALVES

THE COMPACT LINE. Mobile power packs in convincing BAUER quality l/min 225 / 330 bar TOUGH RELIABLE WELL ESTABLISHED

RESIDENTIAL REGULATORS

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Life Raft - Product Information

Pressure Regulators. Instructions for Use

FLOWMETER UNITS FLOWMETER DEVICES, BY-PASS SYSTEMS

PLD 03 T A CASAPPA S.p.A.

CASH VALVE TYPE KP BACK PRESSURE VALVES

BRITISH COMPRESSED GASES ASSOCIATION Registered office: 4a Mallard Way, Pride Park, Derby, UK. DE24 8GX Company Number: 71798, England

The right atmosphere for health. A system for medical gas supply

Description Advanced Features Typical Applications

Direct Operated Precision Regulator Modular Style. Standard Specifications

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

ISO INTERNATIONAL STANDARD. Flow-metering devices for connection to terminal units of medical gas pipeline systems

BY GREGGERSEN CATA LOG

DESIGN CONSIDERATIONS AND GUIDANCE FOR THE SAFE USE OF MEDICAL GAS VIPR

Pressure regulators for a wide range of applications

Dialflow Regulator. Instructions for Use

Wheel operated residual pressure cylinder valve (Inline) in O-ring seal design for technical and medical gases

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

SUCTION Attachments 7 Suction Regulators 10 Accessory Products 11. EMERGENCY RESUSCITATION Oxy-Viva 3 12 R-Viva 13 Demand Valves & Masks 15

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

HIGH PRESSURE CYLINDER VALVES HIGH PRESSURE CYLINDER VALVES

4.0 DOT CYLINDERS 17

SERIES-O REGULATOR. Instructions for use

Emergency Mobile Unit Medicinal gases everywhere, always on time

Table of Contents. Operating Instructions. Resource v.2 Conserving Regulator

B84G - Excelon Plus Modular System General purpose filter/regulator

Optimum oxygen supply for your patients! ATMOS Oxygen Supply

QUALIFIED EXPERIENCE AND CERTIFIED RELIABILITY

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

PULSAR4 Pressure regulating valve (Unloader)

erc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Flowmeters & Accessories Guide

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

AIR/OXYGEN BLENDER INSTRUCTION MANUAL

Types 749B and R130 Changeover Manifolds

SG3 Series Regulators - Pressure Reducing

Plant, components and devices for very high and high pressures (7000 bar and over)

Precision matters. HiQ equipment for specialty gases.

Livewell/Baitwell Pumps. Livewell/Aerator

CLASS TLP Pressure Reducing Valve

SAFETY PRINCIPLES FOR PRESSURE REGULATORS FOR MEDICAL OXYGEN CYLINDERS

COMPACT TRIPLE WALL OUTLET STATION MODEL INSTALLATION AND OPERATING INSTRUCTIONS

Piloted Non-Return Valves

[Instruments for vacuum measurement, checking and adjustment] 3

Pressure Regulator. Instructions for Use

INTERNATIONAL ISO STANDARD Anaesthetic machines for use with humans. Appareils d anesfhesie pour utilisation chez I homme

SG2 Series Regulators - Pressure Reducing

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

Breathing Air Purifiers. Comply with European Pharmacopoeia and International Breathing Air Standards

DS05C,D,G Dial Set Pressure Regulating Valves

Flow meter. bellow vaporizer. APL valve. Scavenging system

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

World Area Differences Technical Information

B74G - EXCELON Modular System General purpose filter/regulator

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Oxygen Usage Best Practice Guide

Equinox II USER MANUAL NITROUS OXIDE/ OXYGEN 50%/50% ADMINISTRATION SYSTEM (01EQ7000E) DEMAND VALVE (01EQ7001E) O-TWO MEDICAL TECHNOLOGIES INC.

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Pressure Reducing Valve DMV 750 set range: bar

CENTRAL GAS SUPPLY SYSTEMS COMPONENTS AND ACCESSORIES

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

DISPOSABLE GAS EQUIPMENT

PRO-50 Instrument Supply Regulator

CRYOGENIC SERIES Regulators, Pressure Gauges, Shut-off Valves, Relief Valves Technology for a Better Future

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

VB85/ Pressure regulating valve (Unloader)

SG1 Series Regulators - Pressure Reducing

valves and actuators SUBSEA ACTUATION

Technical Specification

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI

MEDICAL GAS SYSTEM & EQUIPMENT

PULSAR4 Pressure regulating valve (Unloader)

BRAZING & CUTTING. Kits Easy To Use

Si C132. Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

O-Two Self-Study Guide. Equinox Relieve

Air Amplifiers & SYSTEMS

Transcription:

Valve with Integrated Pressure Regulator for medical OXYgen Handling and performing ALL IN ONE solution Compact and light design User friendly Suitable for home care, intensive and baby care Use for oxygen, nitrous oxide and mixture of the above Available on 230 or 300 bar touch

Applications Home care The Viproxy s user friendly features and smart design are what make a real difference especially when used at home. The valve was designed not only to be reliable under all operating conditions, but already in the design phase a distinctive target was set to make use and operating features simple and carefree. Intensive care For well over sixty years we have been manufacturing and supplying pressure control equipment to markets throughout the world. Our experience and the quality of materials and components we use are second to none especially when it comes to life support. This is why institutions worldwide when making a choice select Cavagna Group pressure control equipment.

Baby care Babies can have health issues that are different from older children and adults. The all new Viproxy regulator valve though was designed to be used for patients of all age groups. The built in regulating features combined with the dynamic flow selector guarantee a constant and measured oxygen dispensing. Nitrous oxide sedation Commonly known as laughing gas, nitrous oxide is mostly used as a dental sedation method for those patients with dental anxiety. Although the Viproxy was not specifically designed for this application, thanks to its innovative technological features it has become a well known product among dental professionals as well as emergency operators.

For over 60 years our Group has been designing, developing and manufacturing medical valves and regulators for the healthcare industry. Our mission has been, is, and will continue to be, delivering high performance equipment to hospitals, homecare services, and clinics. The viproxy valve has been designed to be safe, reliable and multipurpose. Cavagna Group is there where it counts. A user friendly design allows access to the main functions from one side without having to turn the cylinder. TECHNICAL SPECIFICATIONS Viproxy incorporates an Active Gauge that allows pressure reading, when the cylinder shut-off valve is closed. This will allow quick reading of the remaining quantity of gas contained in the cylinder. Special fluorescent dial provides great reading visibility in the dark. Dual outlet (hose barb and fixed high pressure) cover all the possible applications of the Viproxy. Dual reading dials on the side and on the top of the flow selector allow easy reading from different angle perspectives. Viproxy incorporates also a residual pressure device, to protect cylinder from accidental contamination. A spring loaded pressure relief device is located in the low pressure section of the regulator to discharge accidental overpressures. Viproxy incorporates a low torque non rotating spindle shut off valve for lower torques at high service pressure. Maximum torque at 300 bar working pressure is 1,2 N/m. The On-Off Handwheel can allocate a transponder for cylinder data tracking. A sintered bronze filter is incorporated in the inlet of the valve preventing particles from entering the valve. On demand it may also incorporate an excess flow device. All thread configurations are available. Viproxy is the first VIPR to incorporate a balanced regulator oriented in a horizontal way. Balanced regulator allows a better flow rate accuracy at (+/- 5% of dial at setting) different service pressures. Horizontal orientation of the regulator reduces the overall height of the valve improving its resistance to lateral impact. Filling port. With Protection Nut and chain. (optional) Viproxy can be equipped with bursting disc device on the high pressure side depending on customer requirements. Various Pressure ratings are available.

ASSORTED PLASTIC PROTECTION HANDLES COMPLYING WITH IMPACT TEST REQUIREMENTS OF ISO 11117 AND AVAILABLE IN DIFFERENT COLOURS ON DEMAND 1 ASSEMBLED ON THE VALVE 2 ASSEMBLED ON THE CYLINDER NECK RING Hospital bed hanger 3 ASSEMBLED ON THE CYLINDER NECK RING 4 COMPACT ERGONOMIC VERSION ASSEMBLED ON THE VALVE AND THE CYLINDER NECK RING

An o new touch TECHNICAL SPECIFICATIONS 1 touch incorporates an Active Gauge that allows pressure reading, when the cylinder shut-off valve is closed.this will allow quick reading of the remaining quantity of gas contained in the cylinder. Special fluorescent dial provides great reading visibility in the dark. Dual outlet (hose barb and fixed high pressure) cover all the possible applications of the Viproxy. Dual reading dials on the side and on the top of the flow selector allow easy reading from different angle perspectives. 1 touch incorporates also a residual pressure device, to protect cylinder from accidental contamination. pos ges An integrated pressure relief device is located in the low pressure section of the regulator. 1 touch incorporates also a low torque non rotating spindle shut off valve with an integrated ten position flow setting device. A sintered bronze filter is incorporated in the inlet of the valve preventing particles from entering the valve. On demand it may also incorporate an excess flow device. All thread configurations are available. tou 1 touch integrates an high flow piston regulator upper stream protected by a special labyrinth filter. 1 touch can be equipped with bursting disc device on the high pressure side depending on customer requirements. Various Pressure ratings are available. Filling port. With Protection Nut and chain. (optional) HIGH PERFO piston pressu Total weight w protection ca

perational concept ASSORTED PLASTIC PROTECTION HANDLES COMPLYING WITH IMPACT TEST REQUIREMENTS OF ISO 11117 AND AVAILABLE IN DIFFERENT COLOURS ON DEMAND ition 1 ERGONOMIC VERSION ASSEMBLED ON THE CYLINDER NECK RING 2 ASSEMBLED ON THE VALVE ture ch 3 COMPACT ERGONOMIC VERSION ASSEMBLED ON THE VALVE AND THE CYLINDER NECK RING RMANCE re regulator ith p: 1.400 gr.

Rev. 6 Eng. - 12/13 Technical features: Suitable for up to 300 bar oxygen service pressure (4351 PSI) Active gauge available with PSI or bar scales and fluorescent dial Total weight with protection cap: 1.500 gr. ~ (for the fully equipped version) Conforms all the requirement of EN-ISO 10524-3 CE and π marked according to the European Directives for Medical and trasportable pressure devices MRI compatible certified up to Tesla 3 Conforming to the PILL test ASTM G175 (up to 230 bar 1touch) Optional features: Hospital bed hanger available for all handle versions (see images below) Protection handles conforming to ISO 11117 Non-active gauge Configuration available with 1 or 2 outlet. Barbed fitting for 1/4 I.D. hose and Quick connection with pressure fixed at 4 bar (58 PSI) Antifilling device and non return valve in the filling port Filling port protection nut Bursting disc device Excess flow device Special smart filter cartridge Available with different flowmeter ranges: Application l/min Baby care 0 ¼ ½ ¾ 1 1 ½ 2 2 ½ 3 4 5 6 Home care 0 ½ 1 2 3 4 5 6 8 10 12 15 Home care 0 ¼ ½ 1 2 3 4 6 8 10 12 15 Intensive therapy 0 1 2 3 4 5 6 8 10 12 15 25 Intensive therapy 0 ¼ ½ 1 2 3 4 6 8 10 15 25 Dimensions: max 26,7 kg max 30 kg max 27 kg max 50 kg max 16 kg 1touch 115 mm 153 mm 198 mm 165 mm 101 mm 96 mm 114 mm 110 mm 165 mm 165 mm 130 mm 160 mm 120 mm 142 mm 100 mm 175 mm 124 mm PERGOLA s.r.l. Via Statale n.11/13-25011 Ponte S.Marco di Calcinato (BS) - Italy Tel. +39 030 9663111 - Fax +39 030 9980894 www.cavagnagroup.com For further information visit www.viproxy.com

ATOM Valve with Integrated Pressure Regulator for medical OXYgen ONLY 900 Gr The first optimized solution for home healthcare Compact and light design suitable for <5 L capacity cylinders User friendly Extra light solution Easy handling for everyone

ATOM Valve with Integrated Pressure Regulator for medical OXYgen Active Gauge Viproxy Atom incorporates an Active Gauge that allows pressure reading, when the cylinder shut-off valve is closed. This will allow quick reading of the remaining quantity of gas contained in the cylinder. Special fluorescent dial provides great reading visibility in the dark. Piston Regulator Viproxy Atom incorporates an optimized piston regulator designed for home healthcare. Filling Port Viproxy Atom incorporates an exchangable modular filling port. Low torque non-rotating spindle Viproxy Atom incorporates a low torque non rotating spindle shut off valve for lower torques at high service pressure. Maximum torque at 300 bar working pressure is 1,2 N/m. The On-Off Handwheel can allocate a transponder for cylinder data tracking. Protection Handle Assembled on the valve, designed for the maximum compactness and comfort. We understand the need for patients to remain active while receiving at-home care, and in order to do so, they need lightweight and portable solutions. Viproxy Atom valve with integrated pressure regulator for medical Oxygen works reliably in home care Oxygen therapy. The valve was designed not only to be reliable under all operating conditions, but already in the design phase a distinctive target was set to make use and operating features simple and carefree. Looking at the benefits, people get out of the house and remain engaged in life outside their home. While out, using oxygen makes it easier to do more, brain thinks more clearly and people are much happier when in the company of others. PERGOLA SRL Via Statale 11/13 - Frazione Ponte San Marco 25011 Calcinato - Brescia (Italy) Tel. 0039 030 9663111 - Fax 0039 030 9980894 info@cavagnagroup.com www.cavagnagroup.com Technical features: The first optimized solution for home healthcare Compact and light design suitable for <5 L capacity cylinders Suitable for up to 300 bar oxygen service pressure (4350 PSI) Active gauge available with PSI or bar scales and fluorescent dial Non return valve in the filling port Total weight with protection cap: 900 gr. ~ (for the fully equipped version) Conforms all the requirement of EN-ISO 10524-3 CE and π marked according to the European Directives for Medical and trasportable pressure devices Flow Scales: Application l/min Home care 0 1/2 1 2 3 4 5 6 8 10 12 15 Home care 0 1/10 1/4 1/2 1 2 3 4 6 8 10 15 Optional features: Custom Flow Scales available upon request Other Active gauge Configuration available with 1 outlet. Barbed fitting for 1/4 I.D. hose or Quick connection with pressure fixed at 4 bar (58 PSI) Antifilling device available upon request Filling port protection plug in metal or plastic Excess flow device available upon request Special dip tube or special smart filter cartridge 4CA1532 - Rev.0 ENG. 11/15