Modulating Flow Control with Mesurflo

Similar documents
Figure 4 Figure 5 Figure 6

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Pressure Independent Control Valves

CONTROL VALVE WHAT YOU NEED TO LEARN?

Hydronic Systems Balance

WaterSource Heat Pump Hose Kit Performance Specification-Summary

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Lesson 6: Flow Control Valves

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Process Simulator Evaluates Blower and Valve Control Strategies for WWTP Aeration

VB-7213 Series. Application. Features. Applicable Literature. 1/2" to 2" Screwed NPT Stem Up Open, Two-Way Valves General Instructions

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

LABORATORY EXERCISE 1 CONTROL VALVE CHARACTERISTICS

CASH VALVE TYPE KP BACK PRESSURE VALVES

LINE PROPORTIONERS LP NPR260 Approvals: UL, ULC

VB-7273 Series. Application. Features. Applicable Literature

The Discussion of this exercise covers the following points:

Models 106-RF / 206-RF Rate of Flow Control Valve

EN00 Pre-Instructional Survey

VB-7212 Series. Application. Features. Applicable Literature. 5/8" O.D., 45 SAE Flared Stem Up Open, Two-Way Valves General Instructions

VBS-9263 Series. Application. Features. Applicable Literature

Fundamentals of Hydronic Design. Fundamentals of Hydronic Design. Fundamentals of Hydronic Design. Fundamentals of Hydronic Design

VB-7263 Series. Application. Features. Applicable Literature

AUTOMATIC FLOW CARTRIDGES. Competition Analysis Not All Automatics Are Created Equal

FUNDAMENTAL PRINCIPLES OF SELF-OPERATED PRESSURE REDUCING REGULATORS. John R. Anderson Emerson Process Management Fluid Controls Institute

Gerald D. Anderson. Education Technical Specialist

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

Pettinaroli Pressure Independent Control Valves. EvoPICV

PRESSURE COMPENSATORS TECNORD

Operational Settings:

The Use of a Process Simulator to Model Aeration Control Valve Position and System Pressure

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

RTG 25. Introduction

PROCESS MONITORING AND CONTROL

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

BACK PRESSURE / SUSTAINING

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

Float Operated Level Controllers

Rate of Flow Valve Series 120

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Noth American 7347 High Pressure Gas Regulators

ISO INTERNATIONAL STANDARD

Type R622 Pressure Reducing Regulator

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

BACK PRESSURE / SUSTAINING

This portion of the piping tutorial covers control valve sizing, control valves, and the use of nodes.

Pressure independent control valve (PICV) FLOWMATIC

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

Third measurement MEASUREMENT OF PRESSURE

Chapter 10: Bidirectional Flow Controls

The Advancement of Pressure Independent Technology

Full Range Pressure Compensating Variable Flow Control

GeQuip Joule Thomson Plant. Process Description (see Figure 1) Standard Control Instrumentation

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Appendix A Frequently Asked Questions

Control Valves, Actuators, & Pressure Safety Valves

Aspects of Flow Control in Metering Henry Gomes SGS Kuwait WLL

Series MX pressure regulators 3/

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

RELIEF VALVES IN PARALLEL

Proper Pump Installation Practices

FILTER BYPASS CONTROL

WW-730. Pressure Sustaining/Relief Control Valve

The Ins and Outs of I/P Transducers

STANDARD FOR CONTROL VALVE SEAT LEAKAGE

Powers Controls D Day-Night Thermostats

TOPIC: KNOWLEDGE: K1.01 [2.5/2.7] An atmospheric pressure of 15.0 psia is equivalent to... A psig. B psig. C psig.

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

FloCon Commissioning Modules DESIGN GUIDE - JUNE Variable Flow Systems & Solutions brought to you by Hurlstones

OPERATING AND MAINTENANCE MANUAL

SINGLE VALVE WITH LOW-FLOW BYPASS

Model: 43T. Bermad Pressure Relief Valve

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Characterizers for control loops

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

TECHNICAL INSTRUCTIONS Iron Body Series 597 SI

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Gas Lift Valve Testing

OIL & GAS. 20th APPLICATION REPORT. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. Q&A: OPEC Responds to SHALE BOOM

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

Reset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5

VALVES HIDROMATIC VALVE.

Reverse Osmosis System Installation Guide and Operation Manual.

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

Solenoid Valves, one - or two step, on/off ICLX

INTRODUCTION TO REGULATOR AND RELIEF VALVE SIZING. Introduction

Continuous Flow Gas Lift Design By Jack R. Blann 2/9/2008 1

Cavitation in Valves

Principle of Operation. Features. Applications. CL34 Operating Schematic

FUNDAMENTALS OF PRESSURE REGULATORS ROBERT BENNETT MANAGER OF TRAINING ELSTER AMERICAN METER

Digital Level Control One and Two Loops Proportional and Integral Control Single-Loop and Cascade Control

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

2-step solenoid valve Type ICLX

Discharge Relief Valve Operation & Maint.

Transcription:

Modulating Flow Control with Mesurflo Excellent synergies occur when using a Mesurflo valve with a modulating temperature control valve. Both valves serve their design function and do not interfere with the function of each other. Since the Mesurflo valve will limit the flow rate of fluid independent of pressure the usual way of approaching the combination of two valves using C V values does not work. Instead the result must be evaluated in terms of flow directly. A look at how the Mesurflo and a modulating control valve each work from the viewpoint of flow will lead into a clear understanding of how the two will behave together. The Mesurflo flow control device is designed to limit flow through the valve to the rated amount on the valve. The Mesurflo operates by the deflection of a diaphragm on to an orifice plate. As flow increases through the flow control the pressure across the Low Pressure Intermediate Pressure High Pressure Figure A: Mesurflo Deflection with Pressure diaphragm increases. This pressure deflects the diaphragm such that the open area between the diaphragm and the orifice plate decreases as shown in Figure A. The orifice plate is carefully designed such that the flow rate through the device is maintained constant from 2 to 80 psi differential across the Mesurflo. Below 2 psi (minimum operating pressure for most Mesurflo devices) the Mesurflo will behave very similar to a fixed orifice (constant C V ). In terms of flow the Mesurflo will produce a restriction proportional to flow rate squared until almost the rated flow. As the flow approaches the rated flow the restriction then becomes independent of flow such that the flow through the Mesurflo is held constant, this is shown in Figure B.

Mesurflo Performance 5 4.5 4 Above 2 psi the Mesurflo acts to maintain the flow at the rated value 3.5 Pressure Drop (psi) 3 2.5 2 1.5 Below 2 psi Mesurflo acts very similar to a fixed orifice 1 0.5 0 4 6 8 10 1 Flow (Percent of Rated Flow) Figure B: Mesurflo Performance The modulating flow control basically operates by changing the open area of the valve in such a way that for each position of the valve there is a different C V. The performance of a typical Equal Percentage valve for a single pressure across the valve is shown in Figure C. Figure D shows the effect of varying pressures on the flow rate through the valve. Note that at all points above the design pressure the flow can exceed the design flow rate. Typical Control Valve Characteristic 10 9 8 7 6 5 4 3 1

Figure C: Typical Control Valve Flow versus Travel at a Single Pressure Typical Control Valve Characteristic 14 1 Maximum Flow Rating of Terminal Unit 10 8 6 4 Design Pressure ½ Design Pressure Drop ¾ Design Pressure Drop 1½ Design Pressure Twice Design Pressure Figure D: Typical Control Valve Performance at Varying Pressures When a Mesurflo device is added in line with the Control Valve there is no impact on the operation of the valve at flows below the rated flow. When the pressure exceeds the design pressure the Mesurflo will act to limit the flow. This is shown graphically in Figure E. Typical Control Valve Characteristic when Combined with a Mesurflo 14 1 Maximum Flow Rating of Terminal Unit 10 8 6 4 Design Pressure ½ Design Pressure Drop ¾ Design Pressure Drop 1½ Design Pressure Twice Design Pressure Figure E: Performance of a Modulating Control valve with Mesurflo

The Mesurflo prevents the system from experiencing excessive flow. This saves energy by lowering total system flow in conditions where higher than normal pressures occur. This also protects equipment from the detrimental effects of flow induced erosion. Since Mesurflo acts very much like a fixed orifice at flow rates below the design point there is no interaction of the Mesurflo with the Control valve for authority. Due to the diminishing returns of heat exchangers, see Figure F, the impact on the control system of limiting flow to the rated maximum is minimal. 1 Heat Transfer Performance %Heat Transfer / ITD (Btu/hrF) 10 8 6 4 4 6 8 10 1 Water Flow (gpm) 30 F In 70 F In Figure F: Diminishing Returns of Heat Exchangers For modulating valves that are controlled by a temperature feedback system the combination of a Mesurflo and Characterized Disk Control valve provides the same benefit as the more expensive Pressure Independent Control Valve. The temperature feedback system will correct for changes in flow due to pressure changes in the system. Below the design point any change in flow will result in a change in temperature off the coil. The controller will modify the position of the valve to provide the correct temperature. This makes the Pressure Independent aspect of a PICCV superfluous below the design point. The temperature off a typical coil is provided in Figure G. Feedback System Signal Air Off Coil Bulk Temperature ( F) 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 4 6 8 10 Percentage of Design Flow 30 F Air In 70 F Air In

Figure G: Air Off Coil Temperature / Feedback Signal As can be seen the change in temperature off the coil diminishes as the flow approaches the design point. A detail of the change in temperature is provided in Figure H. Feedback System Signal Air Off Coil Bulk Temperature ( F) 190 189 188 187 186 185 184 183 182 181 180 7 8 9 10 11 1 13 14 15 Percentage of Design Flow 30 F Air In 70 F Air In Figure H: Detail of Temperature Off Coil / Feedback Signal at Design Point As can be seen it is only at the design point where the air off temperature control breaks down. At the design point the change in temperature is not sufficient to provide control. For example a dead band of ±2ºF (fairly normal) will result in no position correction until 15 of design flow. Without flow control, this provides a potential waste of 5 of flow, increasing both the pressure drop of the distribution system (further exacerbating imbalance) and the flow required. Mesurflo in line with each control valve will prevent the flow from increasing above the design point, correcting the only limitation found in the use of modulating valves with air off control. 114 Eason Road / P.O. Box 580 Dallas, NC 28034 800-354-4297 (T) * 704-922-9595 (F) www.haysfluidcontrols.com