Körting Liquid Jet Vacuum Ejectors

Similar documents
The Original Simply The Best. Dredging Technology with Körting Ejectors

PENBERTHY SERIES LM, ELL, FL, GL, GH, U, L AND 2NC FOR PUMPING GASES

Pressure reducing valves Index

Pressure Relief Valve DHV 718

Features. General application. Technical data

Instruction presentation Special valves

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

Pressure Reducing Valve for Steam Type 2333 A

Aeration and vent valve BE 891

pumping gases JET PUMP TECHNICAL DATA

Pressure Reducing Valve DMV 755

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

pressure regulator Zero pressure regulator Proportional pressure regulator Compressed air-controlled

Pressure Reducing Valve DMV 750 set range: bar

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Air Eliminators and Combination Air Eliminators Strainers

Steam Trap BK BK 212-ASME. Original Installation Instructions English

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Liquid Ring Compressors Engineered-to-Order Compressor Systems

OXYGEN and SYSTEM OXY

Pressure reduction controller (PN 16, 25, 40)

PROTEGO Pressure and Vacuum Relief Valves. Volume 6. in-line. Volume 6. for safety and environment

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Liquid ring vacuum pumps in compact design

Liquid Ring Compressors Engineered-to-Order Compressor Systems

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Integral type Differential pressure flowmeter VNT Series

NAF-Trimball Control Ball Valves

Air Eliminator Series

Dean Pump Self-Priming Chemical Process Pumps

Chlorinator MODEL MK-I

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

Pressure Equipment Directive (PED) 97/23/EC Page 033 of 124

SIHI LPH-X - Liquid Ring Compressors

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Overflow valves Type OFV REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Tank Blanketing Regulators

776 Cryogenic Safety Valve

ejector solutions Flare Gas Recovery & Zero Flare Solutions

Liquid Ring Compressors Engineered-to-Order Compressor Systems

Compact pressure switches for gas and air

Pressure relief valve DHV 718

Manual Chapter 1. 1 st Generation 2 nd Generation

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework)

T 2523 EN Type 2406 Excess Pressure Valve Self-operated Pressure Regulators ANSI version

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Additional sheet to leaflet Pressure regulators with safety assemblies, Print No Inlet pressures up to max. 1 bar Page 2

PROCESS ROTATING EQUIPMENT (CENTRIFUGAL PUMPS )

Self-operated Pressure Regulators Type 2405 Pressure Reducing Valve

Tank Blanketing Regulators

GA24 Technical Datasheet

Welcome to the LESER Seminar, Taipei 28. June Design_of_safety_relief_valves_250804_Cal

Applied Fluid Mechanics

PRESSURE REDUCING VALVE RP45 (EN)

Gas Pressure Regulator R 51

Overflow valves Type OFV Type OFV-SS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Liquid ring vacuum pumps in compact design

3-way control valves VK 3

Diaphragm Valve, Metal

Body Material: PVC, PP, PVDF Bonnet Material: Glass Filled PP Size: ½ - 2 Pressure Rating: 150 psi Set Pressure: 4 to 150psi Seals:

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve

Flexible Metal Hose Products

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Electro Controls. Pressure WattsIndustries.co.uk

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Pressure Relief Valve DHV 718

Seated valve for steam (PN 25)

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

SMART Explosion. Efficient Boiler Cleaning with Explosion Generators

Engineering Letter. Pump Protection

AVP-F. p setting range (bar) Code No. 003H6200

FLUID DYNAMICS Ch.E-204 Umair Aslam Lecturer Department of Chemical Engineering

Remeha Quinta Cascade guide

What is LPG? Released Energy in the narrowest area. Clean and sure in the practise

Application Worksheet

Seated valves VRB 3, VRG 3

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

GAS PRESSURE CONTROL UNIT TYPE 132

756 Safety Relief Valves

Supratec. MEMBRANE-PLATE-DIFFUSER For fine bubble aeration of liquids BELÜFTUNGSTECHNIK UMWELT- & VERFAHRENSTECHNIK SERVICE & WARTUNG

Another convenient term is gauge pressure, which is a pressure measured above barometric pressure.

MULTI-STAGE VACUUM GENERATORS - GENERAL INFORMATION

VA40 - VA45 Technical Datasheet

Level switches Series LD Vibrating fork level switch for liquids and solids

FLOW MEASUREMENT WITH ORIFICES. Types: BLS500 / BLS550

Serie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY

TECHNICAL ACCESSORIES

LESER Deutschland Standard Functional Tightness Test (Cryo) Content

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Siphon vessel / Priming aid

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

Transcription:

Körting iquid Jet Vacuum Ejectors

Körting iquid Jet Vacuum Ejectors iquid jet vacuum ejectors convey and compress gases or vapours with the aid of a liquid motive fluid. During this action vapours - corresponding to pressure- and temperature ratios - can be partially or completely condensed. iquid jet vacuum ejectors consist - as far their function is concerned - of main parts: motive nozzle, mixing zone and diffuser. These three components form a flow path with an extremely varied cross-section for the motive medium, water or any other liquid. The motive nozzle's shape causes a transformation of pressure- into speed energy, the diffuser's shape then effects a re-conversion of kinetic energy into pressure energy. If the motive medium now flows through these three seriesconnected ejector components as a result of the total pressure difference between motive pressure ptr and the necessary lower counterpressure pd, the result will be a static pressure at the end point of the motive nozzle which will be considerably lower than counterpressure pd and motive pressure ptr. At this point the suction flow is introduced into the ejector. Motive flow and suction flow intermingle and, by means of impulse exchange, a part of the motive jet's kinetic energy is transferred to the suction medium. The resulting mixed flow is delivered under pressure gain in the diffuser to counter-pressure pd. Only by a special combination of the geometry for the nozzle, mixing zone and diffuser is it possible to achieve maximum efficiency under the desired operation conditions. Highest efficiency will result for certain suction- and counter pressures at an optimum pairing of motive flow and motive pressure. The motive pressure should therefore always be matched up with the case in question. The following design diagrams are based on the physical properties of water as a motive medium. iquids with other physical properties require a special ejector design as, amongst other things, boiling behaviour, viscosity and the specific weight of the respective liquid have to be taken into consideration for the ejector's design. DN S iquid jet vacuum ejector Head Mixing zone Diffuser Nozzle system Motive connection DN S Suction connection Mixed connection

Delivery behaviour Application Installation position iquid jet vacuum ejectors can extract gases and vapours and compress them. In the case of liquid jet vacuum ejectors the achievable suction pressure at zero load corresponds more or less to the vapour pressure of the motive liquid. So for example, the suction pressure cannot be below mbar = 7, mm Hg for a jet ejector with water as a motive liquid and a motive water temperature of C. For motive media with negligibly small vapour pressure the achievable suction pressure is between and 6 mbar at zero load. When transporting gases with water or another liquid as motive flow we have two media with very different specific weights. Therefore not only the liquid's pressure energy has to be transformed into speed energy but the jet itself must also be torn apart so far as to include the gas components. This duty is fulfilled by means of a suitable spiral in the motive nozzle. The liquid jet leaves the nozzle at high velocity, entrains the surrounding gas into the mixing zone and delivers it to the required counterpressure in the diffuser (normally this is atmospheric pressure). During this action condensable vapours can be condensed or gas components can be absorbed in the motive liquid. Suction performance and pressure rise are determined by the suction and motive flow as well as by pressure and temperature of the motive liquid. During a start-up process a multiple of the gas flow can be achieved in the upper pressure range compared to the suction flow at final vacuum. This is why the liquid jet vacuum ejector is especially suitable for the start-up evacuation of vacuum vessels. Körting liquid jet vacuum ejectors are utilised e.g. for starting up centrifugal pumps, in chemical processes, for venting vacuum condensers but also for mixing gases and liquids. Furthermore, because of their simplicity of constructional form, low purchasing price and ease of installation, liquid jet vacuum ejectors can be applied in all branches of industry where low investment costs are especially required. One particular advantage of the jet ejectors is to be seen in the fact that they can be manufactured practically of all materials such as metals, plastics or graphite. So it is easy to find a suitable material for each corrosion problem arising on the gas or the liquid side. They can also be operated in such application fields where other pump types can only be used with difficulty or even not at all. iquid jet vacuum ejectors are available ex stocks in standard executions up to a mixed flow connection of DN. Special designs can be chosen to suit specific requirements. iquid jet vacuum ejectors should be mounted in a vertical position with the flow direction from top to bottom. Pipelines can be installed in the respective nominal connection widths. A reduction in performance of approx. % must be considered if the ejector is mounted in a horizontal position. For normal installation a down pipe of approx. m in length should be after-connected and should lead into an overflow vessel and be submerged there at least x the pipe diameter. The free liquid surface in the overflow vessel should be at least times the pipe crosssection. If required, a standard separator to separate gas and motive liquid can also be supplied. Gas Mixed flow d xd ayout of a liquid jet vacuum ejector Motive liquid 0

iquid jet vacuum ejectors for continuous operation Motive medium = water at C Motive pressure range - bar (abs.) Diagram for continuous operation Motive pressure range - bar abs. Counter-pressure: atmosphere bara Performance factor K=, bara bara 0 0 0 00 0 0 600 700 0 900 Fig. ps = Suction pressure in mbar Fig. 9 8 7 6 ms(diag)=suction pressure /h, air C Factor D for motive water flow at suction pressure <0 mbar,,,08,06,0,0 bara, bara bara 00 0 Suction pressure in mbar Example: Suction pressure: ps = 600 mbar Motive water temp.: ttr = C Motive water pressure: ptr =, bar abs. Suction flow (air): ms = 6,0 kg/h Acc. to Fig. the result is: ms(diag) =,0 kg/h air (K=) Size determination acc. to performance factor (table): K=ms/ms(Diag) = 6,0/,0=, chosen K=,6 Size G - _" or DN Motive flow acc. to table at, bar abs.: 8 m /h water For suction pressures <0 mbar the motive water throughput is increased by factor D acc. to Fig.. Constructional dimensions and connections acc. to table of dimensions. Operation under increased counter-pressure: Information on reduction in performance at increased counter-pressure can be given on demand. Size Size PErformance Motive flow (m /h) at motive pressure (bara) Thread Flange, G / 0,,7, G 0,6,8,,6 G /,,7 G /,6 6,9 8 8,9 G,,,,87 7,6,,8 6, 7,,8,6 9,76,7, 6,, 70, 8, 9 0 7 Required order data: Determine factor K in acc. with the above given example. Indicate your motive pressure. Choose your material and connection type acc. to the tables given on pages 8 and 9. : Motive pressure: Material: Connection type:

iquid jet vacuum ejectors for continuous operation Motive medium = water at C Motive pressure range - 7 bar (abs.) Diagram for continuous operation Motive pressure range - 7 bar abs. Counter-pressure: atmosphere Performance factor K= 7 bara 6 bara bara bara 0 0 0 00 0 0 600 700 0 ps = Suction pressure in mbar 8 7 6 ms(diag)=suction pressure /h, air C Counter-pressure pd in bar abs.,, 7 bara, 6 bara,9,8,7 bara,6, bara,,,, 0,7 0,8 0,9 Factor for reduced performance Fig. Fig. Example: Suction pressure: ps = 0 mbar Motive water temp.: ttr = C Motive water pressure: ptr = 6,0 bar abs. Suction flow (air): ms = kg/h Acc. to Fig. the result is: ms(diag) = 6, kg/h air (K=) Size determination acc. to performance factor (table): K=ms/ms(Diag) = /6, =, chosen K=, size G" or DN Motive flow acc. to table at 6 bar abs.:, m /h water Constructional dimensions and connections acc. to table of dimensions. Operation under increased counter-pressure: iquid jet vacuum ejectors can be operated at a counter-pressure above atmospheric pressure. Such operating conditions can occur when the resistances after the ejector are increased by long pipelines or filters. To ensure a safe operation the motive pressure must be at least bar. Surmounting a higher counter-pressure is connected to a reduction in suction performance. The decrease in performance in comparison to normal operation may be taken from the diagram in Fig.. Size Size Performance Motive flow(m /h) at motive pressure(bara) Thread Flange G / 0,,7 G 0,6,7 G /, G /,6 6,7 G, 0,,87 7, 6, 7 9,76, 67 08,9,9 7,6 9, 0, 7,8 76 6,,, 8,,,6,8 8 7,,6,9 9,,, 6,8 7, 9 7 Required order data: Determine factor K in acc. with the above given example. Indicate your motive pressure. Choose your material and connection type acc. to the tables given on pages 8 and 9. : Motive pressure: Material: Connection type:

iquid jet vacuum ejectors for start-up operation Motive medium = water at C Motive pressure range - bar (abs.) b = spec. evacuating time in minutes per m 0 0 Diagram for start-up operation Motive pressure range - bar abs. Counter-pressure: atmosphere Performance factor K= bara, bara bara Factor D for motive water flow at suction pressure <0 mbar 0 0 00 0 0 600 700 0 900 ps = Suction pressure in mbar Fig. Fig. 6,,,08,06,0,0 bara, bara bara 00 0 Suction pressure in mbar Example: A tank with V=, m contents is to be evacuated in t=8 min. from atmospheric pressure to 00 mbar. Motive water pressure: ptr =, bar abs. Motive water temp.: ttr = C Acc. to Fig. with performance factor K= the spec. evacuation time will be b = minutes per m.the required performance factor can be calculated as follows: K = (V x b) / t = (, x ) / 8 =,7 The next largest performance factor K=,87 acc. to table will be chosen and size DN is the result. Motive flow at, bar abs. acc. to table:, m /h water. At suction pressures <0 mbar the motive water throughput increases by factor D acc. to Fig. 6. Constructional dimensions and connections acc. to table of dimensions. Operation under increased counter-pressure: Information on reduction in performance at increased counter-pressure can be given on demand. Size Size Performance Motive flow (m /h) at motive pressure (bara) Thread Flange, G / 0,,7, G 0,6,8,,6 G /,,7 G /,6 6,9 8 8,9 G,,,,87 7,6,,8 6, 7,,8,6 9,76,7, 6,, 70, 8, 9 0 7 Required order data: Determine factor K in acc. with the above given example. Indicate your motive pressure. Choose your material and connection type acc. to the tables given on pages 8 and 9. : Motive pressure: Material: Connection type: 6

iquid jet vacuum ejectors for start-up operation Motive medium = water at C Motive pressure range - 7 bar (abs.) b = spec. evacuation time in minutes per m 0 0 Diagram for start-up operation Motive pressure range - 7 bar abs. Counter-pressure: atmosphere Performance factor K= bara bara 6 bara 7 bara 0 0 00 0 0 600 700 0 ps = Suction pressure in mbar Fig. 7 Fig. 8 Counter-pressure pd in bar abs.,,,,9,8,7,6,,,,, 7 bara 6 bara bara bara,,,, Time factor Example: A tank with V= m contents is to be evacuated in t=0 min. from atmospheric pressure to 00 mbar. Motive water pressure: ptr = bar abs. Motive water temp.: ttr = C The spec. evacuation time acc. to Fig. 7 with performance factor K= will be b = 7 minutes per m, the required performance factor can be calculated as follows: K = (V x b) / t = ( x 7) / 0 = 8, The next largest performance factor K=9,76 acc. to table will then be chosen and size DN is the result. Motive flow mtr = 7,8 m /h water (acc. to table) Operation under increased counter-pressure: iquid jet vacuum ejectors can be operated at a counter-pressure above atmospheric pressure. Such operating conditions can occur when the resistances after the ejector are increased by long pipelines or filters. To ensure a safe operation the motive pressure must be at least bar. Surmounting a higher counter-pressure is connected to an increase in evacuation time. The increase in time in comparison to normal operation may be taken from the diagram in Fig. 8. Size Size Performance Motive flow (m /h)at motive pressure(bara) Thread Flange G / 0,,7 G 0,6,7 G /, G /,6 6,7 G, 0,,87 7, 6, 7 9,76, 67 08,9,9 7,6 9, 0, 7,8 76 6,,, 8,,,6,8 8 7,,6,9 9,,, 6,8 7, 9 7 Required order data: Determine factor K in acc. with the above given example. Indicate your motive pressure. Choose your material and connection type acc. to the tables given on pages 8 and 9. : Motive pressure: Material: Connection type: 7

Type 6 Material: Cast Iron Type 6 Material: Bronze G T / = Motive connection G S / DN S = Suction connection G G / = Mixed flow connection Connection female thread G / - G ISO 8 Typ 6 (CI) / *Typ 6 (Bronze) 0,,00,6, Connection nominal widths G G G / G G / G / G G S G / G G / G / G G T G / G / G G / G / Construction size in mm 0/* 8/*8 60 0 0 S 60 70 H 60 70 7 7,,,8 6, Flanged connection DN - DIN Typ 6 (CI) / *Typ 6 (Bronze) Connection nominal widths Construction size in mm 0,,00,6, DN S /* 06/*8 7/* 7/*7 6/* S 78/* 68/*70 9/*7 0/*8 7/*9 H 9/*7 0/*8 /*9 /*0 /*0,8 7, 9,6 Flanged connection DN - DIN Typ 6 (CI) und Typ 6 (Bronze),87 6, 9,76,,00 Connection nominal widths DN S Construction size in mm 6 7 98 S 70 8 08 60 H 70 9 8 68 8

G T / = Motive connection G S / DN S = Suction connection G G / = Mixed flow connection Typ 68 Materials: PVC, PP, PVDF Flanged connection (loose flange) DN -DN DIN Material PVC Typ 68- Material PP Typ 68-6 Material PVDF Typ 68-8 Connection nominal widths Construction size in mm 0,,00,6,,87 6, 9,76 DN S 7 7 6 87 00 9 8 67 8 98 8 6 60 79 8 9 8 9 60 0,6 0,8,,,, 6,7,8 Connection by threaded socket G / - G Material PVC Typ 68- Connection nominal widths Construction size in mm 0,,00,6, G G G / G G / G / G G S G T 6 87 7 8 6 7 90 07 86 9 99 8 7 Adhesive connection with union DN - DN Material PVC Typ 68- Connection nominal widths Construction size in mm 0,,00,6, DNS S G / G / G G / G / G / G / G G / G / 0 77 6 69 6 7 8 9 9 09 8 8 Connection by threaded socket G / - G Material PVC Typ 68- Connection nominal widths Construction size in mm 0,,00,6,,87 6, 9,76 DN S 0 6 9 0 69 799 989 6 7 90 0 8 7 79 86 0 0 0, 0, 0,9,7,8 0, 0, 0,7,, 0, 0, 0,6,,, 0, 9

Programme Jet ejectors Steam, gas, water jet ejectors Steam jet vacuum ejectors Steam jet thermocompressors Steam jet ventilators for creating of vacuum, conveying, compressing and mixing of gases, liquids and solids single and multi-stage, with direct contact condenser or surface condenser for suction pressures from 0.00 mbar for evaporation plants and paper drying equipment Waste gas mixing jets Steam jet liquid ejectors, Steam jet heater, Steam jet heater Type ORK Gas jet gas compressors Water jet liquid eductors, Water jet vacuum ejectors, Water jet ventilators, Water jet solids ejectors Gravel pumps Water jet condensers self-priming Vacuum and heat processing Evaporating units for the textile industry Steam jet cooling systems single and multi-stage with or without thermocompressor for cold water production by partial evaporation Surface condensers, Direct contact condensere for process plants and steam turbines Bereich S Strahlpumpen Vakuumtechnik Badenstedter Str. 6 D-0 Hannover Postfach 9 6 D-0 Hannover Telefon: +9 9-0 Telefax: +9 9- Internet: http://www.koerting.de E-Mail: s@koerting.de -dtsch. 0