ARCHITECTURAL GUIDELINES FOUR-PIECE COMMERCIAL

Similar documents
ARCHITECT GUIDELINES 1000 T

ARCHITECTURAL GUIDELINES ONE-PIECE COMMERCIAL

ARCHITECTURAL GUIDELINES 1000 S

ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL

ARCHITECT INSTALLATION GUIDELINES FOR RESIDENTIAL TRITON INSTALLATIONS

Blue Whale Spa :- Site Preparation and Delivery

Swim Spa Pre-delivery Guide

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

PRE-PURCHASE DECISIONS...1 BEFORE DELIVERY...1

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

Life Smart Spas Frequently Asked Questions

Step-by-Step Planning Guide

SPA WORLD. Pre- delivery Guide

ETL listed for installations within 5 ft. (1.5M) of outer edge of water

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

Swimming Pool Requirements Packet

APPLICATION FOR A PERMIT TO CONSTRUCT OR ALTER A PUBLIC SWIMMING POOL, SPA POOL, WADING POOL OR FOUNTAIN

GWINNETT COUNTY SWIMMING POOL PLAN REVIEW CHECKLIST

ROCKDALE COUNTY NEW SWIMMING POOL PLAN REVIEW

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

Jackson County Department of Public Health Application to Construct, Install, Remodel or Modify a Public Swimming Pool

You are now the proud new owner of an Alpine Swim Spa!

Jennifer Hatfield FSPA Government Relations Consultant J. Hatfield & Associates, PL

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Dan Johnson, CBP Swim, Incorporated Lead Dog Aquatic Consulting

1 Exam Prep NSF/ANSI Tabs and Highlights

Spas Hotels/Resorts Apartments & Condominiums Campgrounds Health Clubs Medical Clinics Waterparks

Life Smart Spas Frequently Asked Questions LS600DX

KERN COUNTY PUBLIC HEALTH SERVICES DEPARTMENT ENVIRONMENTAL HEALTH DIVISION

Blue River Technologies Port-A-Poly Mixer w/2.5 GPH LMI Pump And Secondary Water Dilution Line INSTALLATION AND OPERATION

2018 MODEL. SwimFit / SwimExpert INSTALLATION GUIDE

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

In Vessel Composter Installation & Commissioning Manual

D E L U X E S E R I E S. Your Hot Tub Pre-Delivery Guide D E L U X E

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

AMITY TWP POOL REQUIREMENTS

SANITIZERS SANITIZERS SANITIZERS FOR POOLS & SPAS

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS CMP SERIES. Brilliant Wonders LED BUBBLERS

Your Hot Tub Pre-Delivery Guide

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 271

1020 Industrial Drive, Orlinda, TN fax

Pool Name Length Width Lineal Ft. Gallons Weight $ Price $

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

PLAN REVIEW NEW CONSTRUCTION AND MAJOR REMODEL WORKSHEET

Office Use Only Fee Paid

Installation. Heat Trace Combination Drench Shower and Eyewash Unit (includes 120 V and 208/240 V versions) S19-304GA

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

RED DOT UNITS 72R SERIES. Controls. Water & Air PAGE 343

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

WARNING: FOR OUTDOOR USE ONLY

COATINGS SPRAY GUIDE Fast Set Urethane 530

icon i150 / i350 Installation / Operation Manual

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

LAKOS Waterworks. PWC Series Sand Separators. Installation & Operation Manual LS-829 (10/12)

MATH AND MAINTENANCE FOR PUMPS AND BLOWERS TRAINING SEMINAR

Swimming Pool Plans and Specification Report

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

COATINGS SPRAY GUIDE Urethane 520

Ventam 85 Installation & Commissioning Instructions

DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank

Pool Inspection. Your Street San Diego, California Prepared for: Your Name Prepared by: Priority Inspection Service

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212)

PRECAUTIONS. Never enter the swim area unless the floating cover is completely removed and stored.

Flow Material Length. Weight GPM LPM. Style 3095

2018 MODEL. SwimFit / SwimExpert INSTALLATION GUIDE

Propane Conversion Kit Instruction

Swimming Pools, Hot Tubs and Spas

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Accu-Tab Systems 2000 P Series by Axiall Corporation

MOREHEAD CITY COUNTRY CLUB POOL BUILDING

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

KJ1000 Operating Instructions & Parts Manual NSN

SWIMMING POOL, SPAS, HOT TUB REQUIREMENTS AND GUIDELINES (Updated 3/2018)

PUBLIC POOL CHECKLIST. (This checklist is based on the Ministry of Municipal Affairs and Housing checklist)

Vertex VP Operation and Maintenance

KJ4000 Operating Instructions & Parts Manual NSN

City of DuBois PERMIT APPLICATION P. O. Box 408, 16 West Scribner Ave - DuBois, PA Phone: Fax:

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

Lincoln County Environmental Health Department 302 North Academy Street, Suite B Lincolnton, NC Phone: Fax:

City of Crystal Lake Community Development Department

SEMI FIXED/PORTABLE LINE PROPORTIONERS SLP NPR270

City of Lockport Above Ground Pool Regulations

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

ENGINEERING DATA. Engineering Data

2004 Consumer Planning Guide

JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE

Swimming Pool Requirements

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

Pressure Dump Valve Service Kit for Series 3000 Units

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

Accu-Tab Systems 1000 Series by Axiall Corporation

HAS2400 Hepa Air Scrubber

Check with local zoning official for property line distance requirements.

Pressure Dump Valve Service Kit for Series 2300 Units

Saline C 6.0 Junction Box

1 Exam Prep NFPA 99 Health Care Facilities Questions and Answers (Plumbing Contractor)

Transcription:

ARCHITECTURAL GUIDELINES FOUR-PIECE COMMERCIAL

ARCHITECT GUIDELINES FOR SWIMEX FOUR-PIECE COMMERCIAL INSTALLATION GENERAL LAYOUT Call SwimEx at 800-877-7946 to receive AutoCad Drawings of the SwimEx Model that you will be installing. These drawings can be placed directly into your pool room layout and site drawings. SwimEx pools are available in two versions: For existing construction, the pool comes standard in four pieces. For new construction we recommend that the option for the pool assembly at the factory be purchased (SX418). In this case, the pool arrives as one piece and is placed into the facility early in construction. ** See Blueprint Section for sizes of pieces and whole pool. Check local jurisdiction for any pool room requirements. Jurisdictions often require signage, lavatory facilities, shower rooms, drainage, hose bibs, and many other items to be indicated on site plans. State Pool Codes are available from the NSPI (703-838- 0083) Provide a flat level surface for pool to sit on with a load bearing capacity of 460 lbs./sq. ft. **Footprint of pool must be level, remainder of pit or area can be sloped to drain water. Below ground installation requires a minimum pit of 12 wide by 20 long and 68 deep. The pit side walls provide no structure for the pool they are only retaining walls for keeping back fill from falling in against the side of the pool. Above ground installation requires a minimum ceiling height of 10 with no obstructions above the pool (Lights, vents, ducts, beams) ** Check local building codes for minimum ceiling height and required decking area. Every SwimEx comes standard with an entrance ladder and 4 observation windows. Based on the orientation of the pool within the room, these elements need to be placed in the optimum locations. Please familiarize yourself with the SwimEx orientation, and make sure that the order specifies the side for the ladder. The ladder can be placed on either side for no charge so long as the order indicates the location. (This is done in the molding process, thus we must know at the time the order is placed)

WINDOW LOCATIONS RIGHT SIDE FRONT END CAP SwimEx 400, 500 and 600 PADDLEWHEEL WINDOW LOCATIONS LEFT SIDE Allow access to equipment and pool via access hatch for inground, or access panels for above ground installations. Patient lifts must be considered for the proper installation. Lifts differ for above and in ground applications. Please specify pool installation method for proper lift specifying. (Aquatic Access is our preferred supplier 800-325 LIFT) Delivery Requirements: Clear passage for 18-wheel truck to deliver and forklift on site to off load pool from truck. ** Please review Shipping Section of Manual. Clear passage from entry to the final location of pool. For the Model 600T; door openings must be 48 wide by 84 tall with a clear area on both sides of the door. For doors leading to corridors, the door and corridor must be 70 wide by 84 tall. ** Please review Site Preparation Section of Manual. A clear, unobstructed working area in and around the pit must be provided for movement of the parts into the pit and assembly of the pool. No decking shall be constructed until the pool has been filled and water tested. Once the pool has been filled and water tested, the decking will need to be constructed around the SwimEx. This is not part of the SwimEx assembly, please refer to Deck Construction Section of the Manual for instructions. Electrical Requirements: Standard pool requires 220/240 Volt, single phase, 105 Amps GFCI Breakers to be provided by electrician Paddlewheel Controller: 60 Amp 208/240V Single Phase Heater : 30 Amp 208/240V Single Phase Pump: 15 Amp 208/240V Single Phase Must provide sub panel with appropriate GFCI breakers for equipment ***Please refer to Electrical Schematic in Electrical section of Manual Variable speed controller takes 220/240Volt single phase in and converts to 3 phase to drive the gearmotor.

Electrician, in accordance with local and national electric codes, must make all connections between equipment and circuit breakers. Connections to be made dealing with the SwimEx are from the breaker panel to the variable speed controller, controller to gearmotor, breaker panel to heater, and breaker panel to pump. These must be done on site by an electrician provided by owner. Conduit needed from Variable speed Controller to poolroom near front of pool for SwimOmeter. Conduit must be able to let a 7/8 diameter connector pass through. The location of the SwimOmeter must be 5 away from the pool and should be determined by the end user of the pool. Ozonator, 110V plug in unit. Should be connected through same line as Pump to ensure that it shuts off when pump is turned off. Other Equipment Considerations: Optional SwimEx equipment: *Please refer to Other Equipment Assemblies Section of the Manual Underwater Lights, 110Volt plug in unit on right or left side of pool. Air button provided to turn light on and off Jet Option : Jet Pump: 220Volt controlled with ES Combo air switch controller (provided with option). Electrician must wire to controller and from controller to pump MOTORIZED TREADMILL OPTION: 220V single phase input, to separate variable frequency drive and then wire from drive to motor on pool. 40 amp circuit required. Non SwimEx Equipment provided by owner Sump Pump: Plumber will locate a sump pump within pit area, connection means must be provided for Lights under deck or in pit area: Pit area must have lights for future maintenance. Ventilation and exhaust requirements. Mechanical Requirements: **Please read and familiarize yourself with the Plumbing section of the Manual Plumbing: Pool is pre-plumbed with all eyeball and suction fittings. On site plumber (by owner) must make connections between pool and provided pool equipment. All connections are PVC and will vary dependent on location. Typical connections are schedule 80 PVC and range from 1 to 3 in diameter. Water fill: ¾ Cold Water fill line for pool (tempered water can be provided but is not required). The fill line must be protected by backflow preventers as required by local codes.

Valve for water fill should be located within poolroom so that operator can see water level as pool is being filled. Drain: The SwimEx comes with a 2 drain from the front of the pool with a shutoff valve. A floor drain or sump pump and pit must be provided for semi annual draining of the pool. Drain from pool is elevated approximately 3 ½ from floor. Drain will have approximate flow of 80 GPM when pool is full. Recommend floor drain in deck near ladder area to drain water from pool deck. Hose Bibs: A hose bib is recommended (and required within some jurisdictions) within the SwimEx pool area for semi annual cleaning of the pool interior. If an aqua-powered lift is being a used, appropriation for water supply and drain must be made. Typical pool lifts need a ¾ line with 55 psi. Ventilation and exhaust from pool room. Small water area exposed to air eliminates need for large dehumidification systems. Typical water loss due to evaporation is in the range of 4-lbs./ hour for a standard SwimEx pool. STANDARD EQUIPMENT The following is a list of the standard pool equipment supplied with SwimEx Models 600 T Series, 480 T, 500 T Series, and 400 T. PUMP: Pentair Pool Products Model: Whisperflow WFE-4 1 HP filtration Pump 87 GPM @ 60TDH Electrical Requirements: 240V single phase 15 Amp GFCI breaker Standard SwimEx 600T 3200 Gallons turnover : 42.5 minutes. NSF LISTED FILTER: Pentair Pool Products Model: Clean & Clear Plus CCP 320 320 Square Feet of filtration Area Design Flow Rate of.375 G/sq.ft. for a flow of up to 120 GPM Connections 2 PVC Glue Unions Dimensions: 43 T x 21.5 dia

Removal of cover req. 62 Height NSF LISTED HEATER: Coates Heater Company Model 12406T 5.5 KW Electric Heater Dimensions 17 ½ L x 4 W x 14 ½ H Electrical Requirements: 240V Single Phase 30 Amp GFIC Breaker feed Architect Guidelines for SwimEx Installation Model 60MT GENERAL LAYOUT Call SwimEx at 800-877-7946 to receive AutoCad Drawings of the SwimEx Model that you will be installing. These drawings can be placed directly into your pool room layout and site drawings. SwimEx pools are available in two versions: For existing construction, the 60T pool comes standard in three pieces. For new construction we recommend that the option for the pool assembly at the factory be purchased (SX418). In this case, the pool arrives as one piece and is placed into the facility early in construction. ** See Blueprint Section for sizes of pieces and whole pool. Check local jurisdiction for any pool room requirements. Jurisdictions often require signage, lavatory facilities, shower rooms, drainage, hose bibs, and many other items to be indicated on site plans. Provide a flat level surface for pool to sit on with a load bearing capacity of 525 lbs./sq. ft. **Footprint of pool must be level, remainder of pit or area can be sloped to drain water. Below ground installation requires a minimum pit of 12 wide by 15 long and 68 deep. The pit side walls provide no structure for the pool they are only retaining walls for keeping back fill from falling in against the side of the pool. Above ground installation requires a minimum ceiling height of 10 with no obstructions above the pool (Lights, vents, ducts, beams) ** Check local building codes for minimum ceiling height and required decking area. Every SwimEx comes standard with an entrance ladder. Based on the orientation

of the pool within the room, these elements need to be placed in the optimum locations. Please familiarize yourself with the SwimEx orientation, and make sure that the order specifies the side for the ladder. The ladder can be placed on either side for no charge so long as the order indicates the location. (This is done in the molding process, thus we must know at the time the order is placed) WINDOW LOCATIONS RIGHT SIDE FRONT END CAP SwimEx 400, 500 and 600 PADDLEWHEEL WINDOW LOCATIONS LEFT SIDE Allow access to equipment and pool via access hatch for inground, or access panels for above ground installations. Patient lifts must be considered for the proper installation. Lifts differ for above and in ground applications. Please specify pool installation method for proper lift specifying. (Aquatic Access is our preferred supplier 800-325 LIFT) Delivery Requirements: Clear passage for 18-wheel tractor trailer truck to deliver and forklift on site to off load pool from truck. ** Please review Shipping Section of Manual. Clear passage from entry to the final location of pool. For the Model 60T; door openings must be 96 wide by 102 tall with a clear area on both sides of the door. For doors leading to corridors, the door and corridor must be 96 wide by 102 tall. ** Please review Site Preparation Section of Manual. SwimEx units are available assembled at the factory. The pool will then arrive in one piece and will be craned into position. Planning must be done so that this can occur early in the construction process to have complete access to the area. Typically this is the most cost-effective way for new construction installations. A clear, unobstructed working area in and around the pit must be provided for movement of the parts into the pit and assembly of the pool. No decking shall be constructed until the pool has been filled and water tested. Once the pool has been filled and water tested, the decking will need to be constructed around the SwimEx. This is not part of the SwimEx assembly, please refer to Deck Construction Section of the Manual for instructions.

Electrical Requirements: Standard pool requires 220/240 Volt, single phase, 95 Amps GFCI Breakers to be provided by electrician Paddlewheel Controller: 40 Amp 208/240V Single Phase Heater : 30 Amp 240V Single Phase Pump: 15 Amp 208/240V Single Phase Must provide sub panel with appropriate GFCI breakers for equipment ***Please refer to Electrical Schematic in Electrical section of Manual Variable speed controller takes 220/240Volt single phase in and converts to 3 phase to drive the gearmotor. Electrician, in accordance with local and national electric codes, must make all connections between equipment and circuit breakers. Connections to be made dealing with the SwimEx are from the breaker panel to the variable speed controller, controller to gearmotor, breaker panel to heater, and breaker panel to pump. These must be done on site by an electrician provided by owner. Conduit needed from Variable speed Controller to poolroom near front of pool for Swimometer. Conduit must be able to let a 7/8 diameter connector pass through. The location of the Swimometer must be 5 away from the pool and should be determined by the end user of the pool. Other Equipment Considerations: Optional SwimEx equipment: *Please refer to Other Equipment Assemblies Section of the Manual Underwater Lights, 110Volt plug in unit on right or left side of pool. Air Button is provided to control lights Ozonator, 110V plug in unit. Should be connected through same line as Pump to ensure that it shuts off when pump is turned off. Jet Option : Jet Pump: 220Volt controlled with ES Combo air switch controller (provided with option). Electrician must wire to controller and from controller to pump Non SwimEx Equipment provided by owner Sump Pump: Plumber will locate a sump pump within pit area, connection means must be provided for Lights under deck or in pit area: Pit area must have lights for future maintenance. Ventilation and exhaust requirements. Mechanical Requirements: **Please read and familiarize yourself with the Plumbing section of the Manual Plumbing: Pool is pre-plumbed with all eyeball and suction fittings. On site plumber (by owner) must make connections between pool and provided pool equipment. All

connections are PVC and will vary dependent on location. Typical connections are schedule 80 PVC and range from 1 to 3 in diameter. Water fill: ¾ Cold Water fill line for pool (tempered water can be provided but is not required). The fill line must be protected by backflow preventers as required by local codes. Valve for water fill should be located within poolroom so that operator can see water level as pool is being filled. Drain: The SwimEx comes with a 2 drain from the front of the pool with a shutoff valve. A floor drain or sump pump and pit must be provided for semi annual draining of the pool. Drain from pool is elevated approximately 3 ½ from floor. Drain will have approximate flow of 80 GPM when pool is full. Hose Bibs: A hose bib is recommended (and required within some jurisdictions) within the SwimEx pool area for semi annual cleaning of the pool interior. If an aqua-powered lift is being a used, appropriation for water supply and drain must be made. Typical pool lifts need a ¾ line with 55 psi. Ventilation and exhaust from pool room. Small water area exposed to air eliminates need for large dehumidification systems. Typical water loss due to evaporation is in the range of 4-lbs/hour for a standard SwimEx pool. Standard Equipment The following is a list of the standard pool equipment supplied with SwimEx Model 60T PUMP: Pentair Pool Products Model: Whisperflow WFE-4 1 HP filtration Pump 87 GPM @ 60TDH Electrical Requirements: 240V single phase 15 Amp GFCI breaker Standard SwimEx 600T 3200 Gallons turn-over : 42.5 minutes. NSF LISTED

FILTER: Pentair Pool Products Model: Clean & Clear Plus CCP 320 320 Square Feet of filtration Area Design Flow Rate of.375 G/sq. ft. for a flow of up to 120 GPM Connections 2 PVC Glue Unions Dimensions: 43 T x 21.5 diameter Removal of cover req. 62 Height NSF LISTED HEATER: Coates Heater Company Model 12406T 5.5 KW Electric Heater Dimensions 17 ½ L x 4 W x 14 ½ H Electrical Requirements: 240V Single Phase 30 Amp GFIC Breaker feed