THE PMI ADVANCED PERM POROMETER

Similar documents
THE PMI ADVANCED CAPILLARY FLOW POROMETER

Capillary Flow Porometer/Frazier/C-522 CFP-1100AEX-F-C522

CAPILLARY FLOW POROMETER CFP-1500AL. Not just products... solutions.

Frazier Permability Tester & Average Fiber Diameter Analyzer. Permeability measurement according to ISO: 4003 & ASTM D standard

PMI ADVANCED AUTOMATED HYDRAULIC PRESSURE LEAK TESTER APCS-H-60K. Not just Products... Solutions!

THE PMI AUTOMATED GAS/HELIUM PYCNOMETER PYC-G100A

PMI Advanced Automated. Pulse Decay Permeameter APDP-10K-HP-101. Not just products... Solutions!

THE MARKET LEADER IN CAPILLARY FLOW POROMETRY CFP1

POROMETER 3G POROMETER. through-pore size analyzer. Membranes. Filters. Non-Woven. Textiles. Papers. Ceramics. Sintered Metals SERIES

PMI Pulse Decay Permeameter for Shale Rock Characterization Yang Yu, Scientist Porous Materials Inc., 20 Dutch Mill Road, Ithaca NY 14850

PMI Advanced Media Bubble Point Tester

US A1 (19) United States (12) Patent Application Publication (10) Pub. No.: US 2005/ A1 Gupta et al. (43) Pub. Date: Oct.

tel: fax: web:

Accelerated Corrosion Test Chambers

Integrity Testing LifeASSURE BNA045 and BNA065 Series Filter Cartridges

Air permeance of paper and paperboard (Sheffield method)

Automatic Isokinetic Sampler. ST5 Evo

Complete Range of Force Tensiometers

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

FPG8601 Force Balanced Piston Gauge

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Pressure Calibrators. Series PC..., PM...

Agilent Flowmeter ADM1000

Pressure Measurement

Determination of Capillary pressure & relative permeability curves

Oil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e

A VALID APPROACH TO CORRECT CAPILLARY PRESSURE CURVES- A CASE STUDY OF BEREA AND TIGHT GAS SANDS

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

HumiSys HF High Flow RH Generator

Tensiometer For the measurement of surface and interfacial tension

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator

Automatic Isokinetic Sampler. ST5 Evo

Level MEASUREMENT 1/2016

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

Customer Responsibilities

HTHP Filter Press for Ceramic Disks with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual

Series Environmental Chambers

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:

Permeability. Darcy's Law

Oxidation Stability of Gasoline and Aviation Fuels

2600T Series Pressure Transmitter Models 264DC Differential and 264HC Gage Level Transmitters. Kent-Taylor

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

Fuel Filters DN15 DN25. elektrogas.com DE

Tensiometer For the measurement of surface and interfacial tension

F&J SPECIALTY PRODUCTS The nucleus of quality air monitoring programs

Valves. Diaphragm shut-off valves, kidney-type

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display:

Air Operated Hydraulic Pumping Systems to 50,000 psi

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

Chest Drainage Systems for Cardiac & Thoracic Surgery. Including portable suction with Digital Air Leak Monitoring

Customer Responsibilities. Important Customer Information. Cary 4000/5000/6000i UV-Vis spectrophotometer Site Preparation Checklist

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Optical Dissolved Oxygen Meter

Gripping modules Pneumatic 2-finger parallel gripper Long-stroke gripper for small components Gripping force 120 N..

UNIVERSAL MASK TEST SYSTEM

InFlow Modular perfusion bioreactor

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

Generating Calibration Gas Standards

Bubble Point / Pressure Decay Test / Gas Transport Rates through Membranes

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

The Palltronic AquaWIT IV Filter Integrity Test System

Variable Area Flow Meters

MoveRoll Conveyor Operating and Maintenance Manual

INSPIRE Min.I. Redefining minimally invasive approach to perfusion. Expand your choices with INSPIRE Min.I.

TECHNICAL INFORMATION

TURBINE SEAL: AXIAL TYPE DESIGN

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1


Mass Flowmeters. Mass Flowmeters for Gases

Next Generation Quartz Pressure Gauges

Additel 761 Automated Pressure Calibrators Selection Guide

PERME- OX2/230 Oxygen Transmission Rate test system

Valve Inspection & Testing

CAPITAL CONTROLS SERIES NXT3000

3 1 PRESSURE. This is illustrated in Fig. 3 3.

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Pressure calibration. 20

How to specify a product. Process Sensors and Mechanical Instruments

TransPort PT878GC Panametrics Portable Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

SITRANS P measuring instruments for pressure

SPECIFICATION FOR REPEATED LOAD TRIAXIAL (RLT) TESTING FOR PAVEMENT MATERIALS

Model PDT Dewpoint Transmitter

OPCom With laser diode Measurement range 4, 6,14 and 21 µm(c) Operating pressure up to 500 bar

ORG. Application example. Special Grippers O-ring Assembly Gripper. Weight 1.35 kg. Ring diameter O.D. Assembly appr.ø 5 mm.. ø 160 mm.

TransPort PT878GC Panametrics Ultrasonic Portable Gas Flowmeter. GE Infrastructure Sensing. Features. Applications

Ultrasonic level transmitter and indicator

AUTOMATIC HOSE TEST UNIT, TYPE SPU

Cell Injury Controller II (CIC II)

Additel 761 Automated Pressure Calibrators Selection Guide

Optical Dissolved Oxygen Meter

TEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions

Int r oduct ion t o Int egr it y Tes t ing Theor y

Ascott an introduction. World leaders in salt spray cabinets and cyclic corrosion test (CCT) chambers for corrosion testing

Your local gas generation partner. Precision series Modular gas generation solution for GC.

DELTI. Vac. DELTI-Vac MIL. Application. Principle. Characteristic

Physics 221, March 1. Key Concepts: Density and pressure Buoyancy Pumps and siphons Surface tension

Oxygen Dialflow Meter. Instructions for Use

Transcription:

THE PMI ADVANCED PERM POROMETER CFP-1020-APLC-GFR The PMI Advanced Perm Porometer is designed to measure pore size of non-wovens according to the standard ASTM F 316-03, Gurley Permeability according to standards ISO 5636-3 and 5, TAPPI-T460, Frazier Permeability according to standards IS:11056-1984, DIN 53887, ASTM D-737-96 ASTM D 3574, EN ISO 7231, BS 5636, ISO-9237/7231, JIS L 1096A, EDANA 140.1, AFNOR G07-111, TAPPI T251, GB/T 5453/13764, and Rayl Permeability according to ASTM C522-03. Not just products... solutions!

Description The PMI Advanced Perm Porometer is capable of measuring pore throat diameter, bubble point, mean flow pore diameter, pore diameter range, and pore size distribution. PMI Perm Porometers are used for R&D and quality control in industries worldwide such as filtration, nonwovens, pharmaceutical, biotechnology, healthcare, household, food, hygienic products, fuel cell, water purification, and battery. Samples often tested include filter media, membranes paper, powders, ceramics, battery separators and health care products. Figure 1 Gas Typical pore analysis procedure Throat Diameter Principle of Porometry A wetting liquid is allowed to spontaneously fill the pores in the sample and a nonreacting gas is allowed to displace liquid from the pores. The gas pressure and flow rates through wet and dry samples are accurately measured. The gas pressure required to remove liquid from the pores and cause gas to flow is given by D = 4 γ cos θ / p where D is the pore diameter, γ is the surface tension of liquid, θ is the contact angle of liquid, and p is the differential gas pressure. From measured gas pressure and flow rates, the pore throat diameters, pore size distribution, and gas permeability are calculated. Figure 2 Basic principle behind analyzing pore structure Principle of Gas Permeabilty The PMI Advanced Perm Porometer can be used to determine the permeability of porous solids. A gas such as air is forced to flow through the test sample. Measurements of the steady-state flow rate and the corresponding pressure drops provide the necessary data for calculation of the permeability using Gurley, Rayl and Frazier units.

Principle of Liquid Permeability The flow of liquid through a sample is measured by the distance a column of liquid drops in relation to time and pressure. This method gives reproducible results, even for hydrophobic materials, as pressure can be applied up to 200 psi to the liquid column to force the liquid through the sample. Very low permeability samples are tested using an accurate weighing balance to measure liquid flow rate. Gas Under Pressure Liquid Sample Liquid Flow Application Figure 3 Principle of liquid permiability test PMI Perm Porometers yield very objective, accurate and reproducible results, considerably reduce test duration, and require minimal operator involvement. The pressure is measured close to the sample and therefore, the correction term in the differential pressure measurement is minimized. This sophisticated instrument has found applications in a wide variety of industries. Testing Capabilities of Porometry Diameter of the most constricted part of a through pore (pore throat) Mean flow pore diameter (50% of flow is through pores smaller than the mean flow pore) Pore diameter range Pore distribution: f = -d[(fw/fd) x 100] / dd fw = flow rate through wet sample fd = flow rate through dry sample Testing Capabilities of Frazier, Gurley and Rayls Permeability Frazier, Gurley and Rayls permeability is measured according to standards ISO 5636-3 and 5, TAPPI-T460, IS:11056-1984, DIN 53887, ASTM D-737-96 ASTM D 3574, EN ISO 7231, BS 5636, ISO-9237/7231, JIS L 1096A, EDANA 140.1, AFNOR, G07-111, TAPPI T251, GB/T 5453/13764, and ASTM C522-03

Optional Capabilities Pressure hold test Hydro-head (break through pressure) test Integrity test Envelope surface area, average particle size and average fiber diameter obtained from gas flow rate through dry sample Multiple sample chamber Multiple test mode Shuffled smoothness test Burst pressure test Use of desired fluid including strong chemicals Elevated temperature test Gurley, Frazier, or Rayls permeability (special sample holders and pressure transducers for high accuracy tests) Porometry Features Fully automated and computer controlled Testing of small samples as well as complete parts Ability to measure diameter of the most constricted part of a through pore (pore throat), bubble point, mean flow pore diameter, pore diameter range, and pore size distribution Any sample geometry (Example: sheets, rods, tubes, hollow fibers, cartridges, & powders) Ability to switch between two or more flow meters Any nonwetting liquid Able to measure permeability of liquids such as water and alcohol Tests in QC, research, or any number of user defined modes Based upon PLC Technology with 24 bit resolution pressure and flow sensors Real time graphic display Window based software for all control, measurement, data collection, data reduction, and report preparation Fluid Surface Tension dynes/cm Diameter µm (100 psi Porometer) Diameter µm (200 psi Porometer) Diameter µm (500 psi Porometer) Water 72 0.30 0.15 0.06 Mineral Oil 34.7 0.14 0.07 0.03 Petroleum Distillate 30 0.12 0.06 0.03 Denatured Alcohol 22.3 0.09 0.05 0.02 Silwick 20.1 0.08 0.04 0.02 Porewick 16 0.07 0.03 0.014 Galwick 15.9 0.07 0.03 0.014 Figure 4 Intrusion Liquid Chart

Frazier Features Fully automatic Windows-based software handles all control, measurement, data collection, and report generation; complete manual control also possible Comes with a PC computer equipt with real-time graphical LCD test display that depicts testing status and results throughout operation Non-destructive testing Length of test approximately 1 minute Wide range of acceptable sample types and sizes Multiple sample chambers available Minimal maintenance required Units in Frazier Automatic, pneumatic sample clamping Interchangeable test head Gurley Features Fully automatic Windows-based software handles all control, measurement, data collection, and report generation; complete manual control also possible Comes with computer equipt with real-time graphical test display depicts testing status and results throughout operation Non-destructive testing Length of test approximately 1 minute Wide range of acceptable sample types and sizes Multiple sample chambers available Minimal maintenance required Units in Gurley Completely automated air permeability tester Pneumatic Clamping Rayl Features Windows-based software handles all control, measurement, data collection, and report generation; complete manual control also possible Compatible with Windows 97 or higher Real-time graphical test display depicts testing status and results throughout operation Non-destructive testing Length of test approximately 1 minute Minimal maintenance required Multiple sample chambers available

Porometry Specifications* Pore Size Range: 0.5-500 microns Pressure Accuracy: 0.15% of reading Pressure Range: 0-20 psi Sample Size for Holder 1: 5-40 mm diameter / 20mm thickness Sample Size for Holder 2: 60mm diameter / 40mm max thickness Flow Meter: Maximum flow rate 200 liter/min capacity Flow Meter Resolution: 1 in 60,000 Pressure & Flow Resolution: 1/60,000 of full scale (1 part in 60,000) Sample Geometry: Sheets, Rods, Tubes, Hollow Fibers, Cartridges, Powders Frazier Specifications* Sample Size: 5 cm2 to 100 cm2 test area Pneumatic Clamping: (180±30)N Pressure Range: Up to 15" water column Pressurizing Gas: Clean, dry or compressed air (Or any other nonflammable and noncorrosive gas) Pressure controller: 0.5 ± 0.01 inch water Accuracy: 0.15% of reading Mass Flow Transducer Range: 200 LPM Power Requirements: 220-230V, 50Hz Gurley Specifications* Air Permeance Range: 0.35µm/(Pa s) and 15µm/(Pa s) and 0.1 µm/(pa s) and 100 µm/(pa s) Sample Size: 100mm x 100mm Pneumatic Clamping: (180±30)N Pressure Range: Up to (127 ± 0.02)kPa Pressurizing Gas: Clean, dry or compressed air (Or any other nonflammable and noncorrosive gas) Pressure Transducer Range: 0 150 kpa Reservoir Volume: 10 litres Pressure controller: 1.47 ± 0.02 kpa Accuracy: 0.15% of reading Mass Flow Transducer Range (3 options): 5-150 ± 2 ml/min 50-500 ± 5 ml/min 300-3000 ± 20 ml/min Power Requirements: 220-230V, 50Hz (others available)

Rayl Specifications* Permeability Range: 100-10,000 Mks Rayls Pressurizing Gas: Clean, dry or compressed air (or any other non-flammable and non corrosive gas) Pore Pressure: 250 psi or more Pressure Transducer Range: 0-500 PA Resolution: 1-60,000 Accuracy: 0.15% of reading Mass Flow Transducer Range: 10cm³/min - 500,000 cm³/min Power Requirements: 110/220 VAC, 50/60 Hz (others available) *Other specifications for this machine are available. Specifications are subject to change without notice. Sales & Services Our sales team is dedicated to helping our customers find which machine is right for their situation. We also offer custom machines for customers with unique needs. To find out what we can do for you, contact us. We are committed to customer support including specific service products, short response times & customer specific solutions. To quickly & flexibly meet our customer's requirement, we offer a comprehensive range of services. Customize your machine today! 20 Dutch Mill Rd, Ithaca, NY 14850, USA Toll Free (US & Canada): 1-800-TALK-PMI (1-800-825-5764) Phone: 607-257-5544 Fax: 607-257-5639 Email: info@pmiapp.com www.pmiapp.com

The most advanced, accurate, easy to use and reproducable porometers in the world. Celebrating 35 years of solutions 20 Dutch Mill Rd, Ithaca, NY 14850, USA Toll Free (US & Canada): 1-800-TALK-PMI (1-800-825-5764) Phone: 607-257-5544 Fax: 607-257-5639 Email: info@pmiapp.com www.pmiapp.commay 2012