mn100 Analog Display

Similar documents
Before installing to a boat of aluminum or steel construction, please contact your Tacktick dealer.

EMC Conformance. Important

Dual Maxi Display User Guide

Maxi Display User Guide

Dual Digital Display

INTRODUCTION TO NETWORK WIND 3 MOUNTING THE UNIT 14 SELECTING THE DISPLAY MODE 5 ABBREVIATIONS AND DEFINITIONS 17

Race Master System User Guide

TOP BLEED Position for SeaTalk 2 colour logo ST 30. COMPASS Operation and Installation

PART 5 - OPTIONS CONTENTS 5.1 SYSTEM EXPANSION 5-3

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

S100 Controller. User guide. English Date: Document number: EN 2006 Raymarine UK Limited

ECHO MANUAL WARNING. L B A ltim e te rs. ECHO is a trademark of LB Altimeters, Denmark

WIND. - Instrument - Installation and Operation Manual English

COMBAT SWIM BOARD. RJE International, Inc. RJE International January 16, TAC-300 Revision 4

Tacktick Wireless Instruments

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

USER GUIDE FOR DATALINE-X SDX. Stowe Marine Ltd. Tel +44(0)

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

GNX Wind. Owner s Manual

Pedometer with PC download. Model: FB322 OVERVIEW FRONT VIEW INDEX

Steer to Wind angle, Wind Mode, when connected to the h1000 Wind Interface

COMBAT SWIM BOARD. RJE International, Inc. TAC-300 Revision C. RJE International August 3, TAC-300 Revision C

ST60+ Depth Instrument Owner s Handbook

OWNER S MANUAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

ST60 Depth Instrument Owner s Handbook. Document number: Date: 1 April 2004

Model 6812C Dual Lane Scoreboard Owner s Manual

GHC Remote Control Instructions manual

Arena by Oregon Scientific

ST40 Bidata Instrument Owner s Handbook. Document number: Date: March 2006

WELCOME TO THE REVOLUTION

iregatta User Manual

OPERATION AND INSTALLATION MANUAL

SP-110 Autopilot OPERATION

Installation, Compensation and Maintenance Instructions for. RITCHIE Compasses. Made In U.S.A

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

BI-680 Online Dissolved Oxygen Controller Instruction Manual

DIVER NAVIGATION BOARD. RJE International, Inc. RJE International Feb 1, TAC-100D Revision 10

PIRANHA I & 2 OPERATION GUIDE

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

Part specifications...6 Installation...8 Installing the instrument...9 First start (only in a Nexus Network)...13 Operation...14 Calibration...

GV Standard X-Vent. Setup, Commissioning & Installation Guide

GNX 20/21. Owner s Manual

ATOC Meteorological Tower (6 meter-4 level) Guide

200 PSI COMPRESSORS - MODEL NUMBERS

100C Air Compressor Kit

GHC 20. Owner s Manual

GNX 20/21. Owner s Manual

Scoreboard Operator s Instructions MPC Control

TS-202 FFU Lever Remote Part Number & Operation & Installation Instructions Version 2.1

INSTALLING THE ECHO SOUNDER TRANSDUCER CHANGING THE OPERATING CONFIGURATION

GNX 20/21 Owner s Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Pilot 3380 A U T O P I L O T. Operation Manual NAVMAN

Remote Control Bait Boat

A4s Operation Manual

AIR FLOW ANEMOMETER INSTRUCTION MANUAL

ACCUSTRIDE ACCUSTRIDEFM. Digital Clip-on Pedometer WC153. Digital Clip-on Pedometer WC154 ENGLISH

Getting to know your Sureshotgps micro V3

GNX 120/130. Owner s Manual

User Manual GRI- 1500Li

Digital Melting Point Apparatus

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

Instruction Manual. Features. Specification: Length: 730mm Width: 500mm Height: 1000mm Sail Area: 0.15m 2. Weight: 692g (w/o battery & receiver)

Version-E E100930

TABLE OF CONTENTS INTRODUCTION 3 SAFETY PRECAUTIONS 3 PACKAGE CONTENTS 4 DEVICE OVERVIEW 4 BUTTON OPERATION SUMMARY 5 BASIC OPERATION 6

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

How to calibrate the formaldehyde sensor within a PPMonitor Wireless Unit:

VERTICAL AIR COMPRESSORS

Manufactured by: AAA

TECNAUTIC_GmbH. Display Functions with the PB100/200 connected: -- GND Speed -- GND Course -- Heading (Gyro option is recommended) 2 m

QRAE II Quick Reference Covers Diffusion & Pump Models with Firmware Version 3.12 and higher

444C DUAL PERFORMANCE VALUE PACK

GHC 20 Owner s Manual

9A5N Solid State CW Paddle

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

GPS OWNERS MANUAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

400C & 450C DUAL PERFORMANCE VALUE PACKS

A180 DO/BOD/OUR/SOUR Meter Instruction Manual

BUILT TO WIN PAINTBALL LOADER SPIRE III MANUAL

USER MANUAL. Premier Way, Abbey Park Romsey Hampshire, SO51 9DH, UK. Tel: (+44) Fax: (+44)

OPERATION & INSTALLATION INSTRUCTIONS

4WD ACCESSORIES BONUS CARRY BAG 100L AIR COMPRESSOR INSTRUCTION MANUAL

User s Guide. Leisure Pilots 715, 730 & 740. for. Issue 06 for use with version V3.00 software (or later) in the Pilot Computer

I. GENERAL INFORMATION

Field 1. Barometer Alarm Symbol. Field 2. Barometer Trend Indicator. Altimeter/Barometer Alarm Symbol Field 4. Altimeter Function Indicator

Car Baby Walker 2-in-1 Baby walker

CONSUMER MODEL INSTALLATION GUIDE

IMPORTANT SAFETY INSTRUCTIONS

S1000+ / S2000+ Tiller Pilots

Operating Instructions Part No

Yakuza OLED Series Droid & Cyborg 07 Board

Outbreaker Sailor Compass / Outbreaker Sailor Compass Medium Model: RA202 / RA282 User Manual TABLE OF CONTENTS

DT 630 ALTIMETER, BAROMETER AND COMPASS WATCH OPERATING INSTRUSTIONS

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

USER S GUIDE DepthTrax 1H HawkEye Portable Depth Finder (DT1H)

WE DON T STOP AT BARRIERS

HERCULES 390 OWNERS HANDBOOK Volume 1 Primary System

DG100 Digital Depth Gauge and Timer. Training Module, Rev B

Bante821 Portable Dissolved Oxygen Meter Instruction Manual

Transcription:

mn100 Analog Display uu040 rev. 8

mn100 Analog Display EMC Conformance All Tacktick equipment is designed to the best industry standards for use in the recreational marine environment. The design and manufacture of Tacktick equipment conforms to the appropriate Electromagnetic Compatibility (EMC) standards. Correct installation is required to ensure that performance is not compromised. Important Due to the wireless communication systems used in Micronet instruments they are only recommended for use on boats up to 14 meters (45 ft.) which are of glass, carbon, or wooden construction. Like any other Electronic instruments your Micronet system is designed to serve only as an aid to navigation and it remains the skippers responsibility to maintain a permanent watch and be aware of developing situations. 2

Contents 1 Information 1.1 Introduction - 2 1.2 Specifications - 2 1.3 Power Management and Battery Life - 4 1.4 Safety and Disposal - 4 2 Operation 2.1 Instrument Display Information - 5 2.2 Switching the System On and Off - 6 2.3 Backlighting - 6 2.4 Audible Signals and Alarms - 7 2.5 Chapter and Page Operation - 8 2.6 Chapter and Page Description - 10 3 Setup and Calibration 3.1 Entering Setup and Calibration Mode - 12 3.2 Chapter and Page Setup and Calibration - 12 3.3 Editing Values - 15 3.4 Setup Page Description - 14 4 Seatrial and Calibration 4.1 Wind Angle and Speed Calibration - 16 5 Installation 5.1 Tools List & Parts - 18 5.2 Precautions and Positioning Advise - 18 5.3 Bracket Mounting - 19 5.4 Surface Mounting - 20 5.5 External Power Connections - 21 6 Maintenance and Fault Finding 6.1 Care and Maintenance - 22 6.2 Fault Finding and Technical Support - 22 6.3 Warranty Information - 24 1

mn100 Analog Display 1 - Information 1.1 Introduction Your Micronet instrument is powered for life by the environment. Although feature packed and highly visible in all conditions, current demand is so low, and the supply so efficient, that the solar-powered display is self sufficient. Combined with other instruments in the Micronet range this display becomes part of a complete navigational system. 1.2 Specifications Height of digits: 7mm (0.28 ) Backlighting: 3 levels with daylight shutoff System-wide or local control Power: Solar Powered 300 hrs autonomy by day, 7 nights at brightest backlighting, 20 nights at economy backlighting without charge Units of display: Wind Speed (knots, meters per second, Beaufort) Alarm: Audible Alarm for Wind Weight: 285g (0.63lbs) Operating Temp.: -100 to +600C (140 to 1400F) Frequency: 868 MHz or 905 MHz 1.3 Power Management and Battery Life What makes your mn100 instrument possible is Tacktick s revolutionary approach to power management. By reducing the amount of power being used by the electronics and maximizing the potential of the sun to provide power, a mn100 instrument becomes a virtually perpetual device. Power status is indicated by two icons on the instrument display: Battery Level and Charge Rate Used together these icons will show the condition of your instrument s power supply. 2

Operation Bright Day Sunny and and Battery is charged and being topped up by the sun. * Battery is low and being charged by the sun. Overcast Day Night and and and and Battery is charged and requires no further charging. Battery is low but maintaining it s level. Battery is charged but is not charging. Battery is low with no charging. LOW Power and Flashing It is recommended that the instrument be left in daylight for some time for the battery to recover, or charge from an external 9-24V power source. A fully discharged battery will recharge in approximately 12 hours of direct bright sunlight. If using the instruments at night power usage can be reduced dramatically by switching the Backlighting to level 1 or Off. If Backlighting is not required on instruments located below decks it is best to set them to Local Backlighting control (see page 15 s6) so that power is not being wasted in instruments which may not be visible from the one being viewed. * If the internal battery is fully charged then it does not matter how much the instrument is subjected to bright sunlight no further charging is required and the Charge Rate Indicator will remain low. If the instruments are to be stored for a long period of time before next use (Over Winter) ensure that the batteries are fully charged before storage. If necessary connect to a 9 to 24v power supply for 24 hrs prior to storage. 3

mn100 Analog Display If there is no boat speed or change in heading registered on the system for a period of 12 hours your Micronet instrument will switch off to conserve power. A POWER SAVE alarm will sound before the instrument system is switched off. Pressing any button within 10 seconds of the alarm sounding will allow the system to remain switched on. Backlighting will automatically shut down/off when operated in daylight. Artificial light WILL NOT recharge the battery. Placing your Micronet instrument close to an artificial light will seriously damage the instrument. Only recharge in natural daylight. Applying External Power In cases where instruments are mounted permanently below decks it will be necessary to apply an external power source to prevent complete discharge of the built in battery. Connections on the rear of the instrument allow a 9V to 24V DC power source to be connected. Connections can be made to the vessels DC system or a 9V battery pack may be connected. It is recommended that permanent connection is only made when the instruments are permanently fixed to the vessel and not when the clip brackets are used. Connection to a 9V (PP3) battery will fully recharge the internal battery over a period of 24 hours. 1.4 Safety and Disposal Your Micronet instrument contains Manganese Lithium Dioxide batteries which should be disposed of correctly. Do not dispose of any instrument in domestic waste. Refer to regulations in force in your country. If in doubt return the instrument to Tacktick Ltd. for correct disposal. 4

Operation 2 Operation Important: Ensure that the Auto Network procedure described on the yellow instruction sheet and full Setup and Calibration has been performed correctly before attempting to use your Micronet instruments for navigation purposes. 2.1 Instrument Display Information 5

mn100 Analog Display 2.2 Switching the System On and Off To switch on your Micronet system select any instrument and press the button for 2 seconds. To switch off your Micronet system select any instrument and press and hold the button for 2 seconds. 2.3 Backlighting At any stage of the instrument s operation press and hold for 2 seconds the button to access the lighting control. Pressing the and buttons will scroll through setting OFF, 1, 2 and 3 whilst changing the Backlighting. Depending on the instrument setup (see page 16 -s5), Backlighting on the whole system or just the single instrument will be altered. Backlighting is automatically switched off in daylight as part of the instrument s power saving feature and will not operate in daylight. 6

2.4 Audible Signals and Alarms Operation At stages during its operation your Micronet instrument will beep to indicate alarms or moments of importance. Power-up Once operating as part of a network the instrument will issue a single beep as it is switched on by pressing the button for 2 second. Button Press A single beep is issued each time a button is pressed A second beep is issued after a 2 seconds hold down of the button. Alarm Timer Continuous bursts of three beeps will indicate an alarm. The alarm activated will be indicated on the digital display, accompanied by the flashing symbol. Pressing any button will silence the alarm. A single beep will be issued at each minute of the countdown. With 1 minute left to go a beep will sound every 10 seconds. With 10 seconds to go a beep will sound every second. Countdown complete will be indicated by a single burst of three beeps. 7

mn100 Analog Display 2.5 Chapter and Page Operation Instrument information is displayed in a Chapter and Page format using the button to scroll through the Chapters and the and buttons to move between Pages. The diagram below shows the information format. Default Chapter Selection 8

Operation Pressing the button at any time will move on to the next Chapter and on scrolling through the Chapters the Page last selected in that Chapter will be displayed. Both Chapter and Page selection will scroll back to the first Page once a cycle has been completed. Page Selection For a full description of each page refer to items 1 to 8 on the following pages. 9

mn100 Analog Display 2.6 Chapter and Page Description 360 0 Wind Chapter (1) Apparent Wind Angle The Actual Wind Angle with respect to the vessel as measured by the Wind Transmitter. and Apparent Wind Speed The Actual Wind Speed with respect to the vessel as measured by the Wind Transmitter. (2) True Wind Angle The True Wind Angle with respect to the vessel, calculated by the instrument taking into account the vessels speed through the water. Both Apparent Wind Speed, Angle and Boat Speed must be available for this calculation. and True Wind Speed The True Wind Speed with respect to the vessel, calculated by the instrument taking into account the vessels speed through the water. Both Apparent Wind Speed, Angle and Boat Speed must be available for this calculation. Magnified Wind Chapter (3) Magnified Apparent Wind Angle The Actual Wind Angle with respect to the vessel as measured by the Wind Transmitter and displayed on a 0 to 60 degree scale. and Apparent Wind Speed (see above) (4) Magnified True Wind Angle The True Wind Angle with respect to the vessel, calculated by the instrument taking into account the vessels speed through the water and displayed on a 0 to 60 degree scale. Both Apparent Wind Speed, Angle and Boat Speed must be available for this calculation. and True Wind Speed (see above) 10

Operation VMG Chapter (5) True Wind Angle (see above) and Velocity Made good to Windward The vessels calculated speed directly upwind. This value is calculated by the instrument from the Boat Speed and Apparent Wind Angle. Beaufort Chapter (6) Beaufort Wind Speed The actual wind speed over the water displayed using the Beaufort scale, calculated by the instrument taking into account the vessels speed through the water and compass heading. Apparent Wind Speed, Angle, Boat Speed and Current Heading must be available for this calculation. and True Wind Angle The True Wind Angle with respect to the ground, calculated by the instrument taking into account the vessels speed through the water. Apparent Wind Speed, Angle, Boat Speed and Current Heading must be available for this calculation. Heading Chapter (7) Analogue Pointer Indicating the direction of North and Magnetic Heading Current Magnetic Compass Heading of the vessel as measured by the Compass Transducer. The value displayed will be affected by the calibration routine for the compass. (8) Tack Magnetic Magnetic Compass Heading that the vessel will follow should it tack through the wind, calculated by the instrument. Apparent Wind Angle and Magnetic Heading must be available for this calculation to be made. (9) Analog pointer indication of True North and COG The vessel s Course Over the Ground as calculated by the GPS Antenna. 11

mn100 Analog Display 3 - Setup and Calibration 3.1 Entering Setup and Calibration Mode To enter the Setup and Calibration menu press and hold for 2 seconds the button. 3.2 Chapter and Page Setup and Calibration Instrument Setup and Calibration is displayed in a Chapter and Page format using the button to scroll through the Chapters and the and buttons to move between Pages. The diagram below shows the information format. Note: Unlike normal operation you must scroll to the Chapter heading page before moving to another chapter. 12

Setup and Calibration Editing Values To adjust any settings press the button. The setting will start to flash and the and buttons will change the value. 13

mn100 Analog Display 3.4 Setup Page Description Units Chapter Press the button quickly to edit, press the or to change units and press the button quickly to select the chosen units. Default values are shown in bold. (s1) Sets the units in which ALL Wind Speed related information is displayed. Knots or Meters per second (M/S). Wind Chapter Press the button quickly to edit, press the or to change units and press the button quickly to select the chosen units. Default values are shown in bold. (s2) (s3) (s4) RESP Sets the update period of the Wind display. Aut/Slow/Normal/Fast Wind Angle Offset Aligns the displayed apparent wind angle with the actual wind direction with respect to the boat. See page 18 for calibration. Wind Speed Calibration Factor Adds a percentage factor which corrects the information from the Wind Transmitter and ensures the Apparent Wind Speed is displayed correctly. See page 18 for calibration. Options Chapter Press the button quickly to toggle the values between settings or press the button quickly to edit, press the or to change values and press the button quickly to select the chosen value. Default values are shown in bold. (s5) AUTO net Only available on the instrument which was used to power up the system. Refer to the Auto Network sheet for further information. 14

Setup and Calibration (s6) (s7) (s8) (s9) LITE Tells the instrument to control the system Backlighting or just its own Backlighting. net/loc. SHOW Allows the instrument to display information when NOT installed as part of a Micronet system for demonstration purposes only. Off/On. LCD Adjusts the viewing angle and contrast of the LCD display to improve visibility under varied mounting possibilities. 1-7 default 4. RSET Returns all the calibration settings to the factory default values. Health Chapter (s10) (s11) V / no Displays the instrument s Software Version, battery level and charge rate to assist in troubleshooting and fault finding. If the instrument is the Master (the one used to switch on the system) then the number of items (nodes) in the system will be displayed. If the instrument is a Slave (was switched on by the system) then the signal strength to the Master will be displayed HULL Shows the signal strength and battery level of the Hull Transmitter to assist in troubleshooting and fault finding. (s12) WIND SIGNL (as above but for Wind Transmitter information) (s13) NMEA SIGNL (as above but for NMEA Interface information) (s14 --) TYPE 4 - Further signal strength indications will be displayed if available. 15

mn100 Analog Display 4 - Seatrial and Calibration Once the Micronet Instrument system has been installed on the vessel and Autonetworking has been completed it is necessary to carry out calibration. It is not safe to use the instruments for navigational purposes until calibration has been carried out correctly. Wind Calibration Both Wind Speed and Direction can be calibrated to ensure that readings from the Wind Transmitter are displayed accurately. 4.1.1 Wind Angle Offset Motor the vessel directly into the wind. Press and hold the button for 2 seconds to enter Setup Press the button repeatedly to scroll to the SETUP/WIND Chapter Press the button to advance to WIND/+0000 Page Press the button to enter Edit Mode Press the or buttons to change the displayed value to 000. The bottom digits will indicate the number of degrees of offset entered. Press the button to exit Edit Mode Press and hold the button to exit Setup and return to normal operation. 16

Setup and Calibration 4.1.2 Wind Speed Correction Note: Wind Speed reading is factory calibrated to display correctly and should not be altered unless external factors are thought to be causing incorrect readings. Correction should only be carried out if a known correct windspeed is available. Press and hold the button for 2 seconds to enter Setup Press the button repeatedly to scroll to the SETUP/WIND Chapter Press the button to advance to WIND/+0% Page Press the button to enter Edit Mode Press the and buttons to change the displayed value to the required percentage. The bottom digits will indicate the displayed Wind Speed. Press the button to exit Edit Mode Press and hold the button to exit Setup and return to normal operation. 17

mn100 Analog Display 5 Installation 5.1 Tools Required and Parts List 1. 2mm or 5mm Drill Bit (7mm if power connection required) 2. Power Drill 3. Cross Head Screwdriver 1. Mounting Template 2. Display Bracket 3. Mounting Screws (3) 4. Mounting Bolts (3) 5. M4 Studs & Thumbnuts (3) 6. Double Sided Tape 5.2 Precautions and Positioning Advice Ensure mounting surface is flat. Leave space between instruments for sun covers. Leave space to remove instrument from bracket (if used). Avoid areas where damage may occur (winch handles, feet, warps etc.) Select a flat, smooth, surface for mounting and use the Template provided to select a suitable position for mounting your Micronet instrument. Check for clarity of vision and ease of access to the control buttons, it is recommended that instruments are positioned such that your arm does NOT pass through the spokes of the steering wheel when operating the buttons. 18

Installation 5.3 Bracket Mounting (Preferred Method) This method allows for the easy removal of an instrument as and when required, for either security reasons or to prevent damage or discomfort whilst not in use. 1. Using the three supplied M4 bolts attach the back plate to the rear of the instrument (Fig.1). 2. Drill three 2mm holes marked BRACKET on the Template and using the supplied self tapping screws attach the clip bracket to the mounting surface (Fig.2). 3. Place the instrument flat against the bracket slightly higher than the final position and slide gently down into position. There will be a small click as the bracket secures the instrument into position (Fig.3). 4. To release the instrument press lightly on the bracket tab and slide the instrument upwards (Fig.4). 19

mn100 Analog Display 5.4 Surface Mounting 5.4.1 Where there is no access to the rear of the mounting surface Easy installation but will allow removal without gaining access to the boat. Position the supplied Template carefully before starting. 1. Drill three 2mm holes marked SURFACE on the Template 2. Carefully snap the facia of the instrument off the main body taking care not to drop the button pads. HINT It may be useful to place a piece of sticky tape across the front of the buttons before removing the facia to prevent them from falling out during the installation. 3. Remove the three captive M4 nuts from the plastic moulding and attach the instrument to the mounting surface using the three self tapping screws provided. Take care not to over tighten the screws as this may cause the moulding to crack. 4. Check the instrument is perfectly level, carefully position the button inserts into the correct slots and snap the facia back into position. 5.4.2 Temporary Mounting 1. Use the double sided tape provided to secure the instrument to a suitable mounting surface. Press the instrument firmly against the surface until secure. Note: This method is recommended for temporary use only. 20

Installation 5.4.3 Where access is available to the rear of the mounting surface This method allows for maximum security of a permanently mounted instrument. Position the supplied Template carefully before starting. 1. Drill three 5mm holes marked B on the Template. 2. Screw the four M4 brass studs into the rear of the instrument. 3. Place the instrument in position pushing the three studs through the newly drilled holes. 4. Using the three supplied thumb nuts, secure the instrument to the surface making sure the instrument is level before final tightening. 5.5 External Power Connections To connect an external 9 to 24 volt power supply to the instrument head from either a portable battery or the vessel s existing power system. 1. Drill two 7mm holes marked P on the Mounting Template and smooth them together with a sharp knife or small file. 2. Pass the supply cable through the new hole and attach the supplied crimp spade receptacles. 3. Remove the blanking plug from the rear of the instrument to expose the terminals. 3. Taking care to connect the correct polarity push the receptacles firmly onto the spades on the rear of the instrument. 4. Mount the instrument head securely in position. 5. Clamp the cable securely close to the instrument. 21

mn100 Analog Display 6 Maintenance and Fault Finding 6.1 Care and Maintenance All Micronet products are totally sealed against water and are not serviceable. Any attempt to take a Micronet product apart will invalidate the warranty. To clean, use only a damp, soft cloth. No detergents, solvents or abrasives should be used. To avoid damaging a Micronet display unit we recommend storing in the supplied soft pack when not in use. If the instruments are to be stored for a long period of time before next use (Over Winter) ensure that the batteries are fully charged before storage. If necessary connect to a 9 to 24v power supply for 24 hrs prior to storage. 6.2 Fault Finding and Technical Support 6.2.1 Power Save Alarm sounds. There has been no significant data activity on the network. The alarm sounds to indicate that the instrument system will turn itself off. To continue using the system press any button to cancel the alarm. 6.2.2 Lost Network Alarm sounds. On a single instrument this indicates that the particular instrument has lost communication with the Master*. Either there is a problem with the Master* instrument or the instrument in question has been moved out of effective range. On several instruments this indicates that these instruments have lost communication with the Master*. Either there is a problem with the master or the Master* has been moved out of effective range. The instruments will power down shortly after sounding the alarm to save power. 22

Maintenance and Calibration 6.2.3 A single instrument flashes the battery symbol and then switches off. The battery level is low on the particular instrument affected. Connect to a 9 to 24V power source or leave in bright sunlight for 12 hours minimum to fully recharge the instrument s internal battery. If the particular instrument is the system Master* then the other instruments will sound the Lost Network Alarm. To continue using the rest of the system power down and restart the system from another instrument. 6.2.4 Low Battery Alarm Sounds. The power level is low in the Hull Transmitter, NMEA Interface or Wind Transmitter. On any Digital Instrument enter setup and calibration mode (page 14) and scroll through to the Health Chapter. Check the signal levels of the Transmitters and Interface Box. Connect the Hull Transmitter or NMEA Interface to a 9 to 24V power source for 12 hours minimum to recharge the internal battery. Leave the Wind transmitter in bright sunlight for 12 hours minimum to recharge its internal battery. 6.2.5 Data is shown as dashes. The information is not been transmitted to the instrument displays. There may be lost communication between the Wind Transmitter or Hull transmitter and the instrument displays. On any Digital instrument enter setup and calibration mode (page 14) and scroll through to the Health Chapter. Check the signal levels of the Hull and Wind Transmitters 6.2.6 Wind speed reads 0. Information being transmitted from the Wind Transmitter is being received with a Zero value. If the anemometer cups at the top of the mast are turning and the Wind Speed reads 0 then there is a problem with your Wind Transmitter. 6.2.7 No NMEA data showing on external instruments. From any Instrument enter setup and calibration mode (page 14) and scroll through to the Health Chapter. Check the signal level and battery status of the NMEA Interface Box. * The Master Instrument is the instrument which was used to power up the entire system. This instrument may be different each time the system is used. If you are fault finding and are uncertain which instrument is the master the switch off the system and switch on again. The instrument which you switched on is now the master 23

mn100 Analog Display Warranty Information Tacktick Limited or its authorized Distributors will repair or replace a Tacktick product free of charge where a manufacturing fault becomes apparent within two years of the purchase date provided: 1. No unauthorized attempt has been made to repair the product. 2. The product has not been misused, operated outside of its intended environment or operated in a manner which is incompatible with the written instructions supplied on purchase. Proof of purchase date is required for the warranty period to be valid. Due to the removable nature of the Tacktick product, on board service will only be available with prior consent from Tacktick or its authorized Distributors. Failure within the warranty period: Simply return the product to your nearest authorized Tacktick Distributor, together with proof of purchase date. Failure outside the warranty period: Simply return your product to the nearest authorized Tacktick Distributor and an estimation for repair will be provided. Authorized Tacktick Distributor details can be found at www.tacktick.com, or on the back of Tacktick sales brochures. 24