PC10HP Pipeline Connector (ASME 600)

Similar documents
TSS21 Sealed Thermostatic Steam Tracer Trap

DF1 and DF2 Diffusers

DCV10 Stainless Steel Disc Check Valve for use with Condensate Pumps

Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators

MST21 Stainless Steel Balanced Pressure Thermostatic Steam Trap

TP1 and TP2 Temporary Cone Shaped Strainers

BT6HC Hygienic Sanitary Balanced Pressure Steam Trap for High Capacity and CIP/SIP Applications

BDV1 and BDV2 Blowdown / Depressurisation Valves

PV4 and PV6 Piston Valves

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

DCV1, DCV3 and DCV3LT Disc Check Valves Installation and Maintenance Instructions

UIB30 and UIB30H Sealed Inverted Bucket Steam Traps for use with Pipeline Connectors

Fig 12, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

DCV6 Disc Check Valve

Fig 1, Fig 12, Fig 13, Fig 14HP, Fig 16, Fig 16HP and Fig 16L Strainers

CVS10 Sanitary Check Valves

TA10A and TA10P Steam Tracing Temperature Control Valves Installation and Maintenance Instructions

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

AVC32 Carbon Steel Air Vent for Steam Systems

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

Dri-Line Mk3 Monnier Compressed Air Drain Trap

Dri-Line Mk2 Spirax-Monnier Compressed Air Drain Trap

AVM7 Stainless Steel Thermostatic Air Vent

IFTGS14 Ball Float Steam Trap ½" and ¾" with Integral Spiratec Sensor

TDC46M, TDS46M and UTDS46M Thermodynamic Steam Traps with Maintainable Seat Installation and Maintenance Instructions

FTGS14 Ball Float Steam Trap DN15 (½") to DN25 (1")

Fig 3, 7, 33, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers

CP10 Sensor Installation and Maintenance Instructions

FV Flash Vessel Installation and Maintenance Instructions

AE14 Automatic Air Vents for Liquid Systems Installation and Maintenance Instructions

S1, S2, S3, S5, S6, S7, S8, S12 and S13 Separators Installation and Maintenance Instructions

CA44, CA44S, CA46 and CA46S Air and Gas Traps

PC3000, PC3001 and PC4000, PC4001 Pipeline Connectors

PC3_ and PC4_ Pipeline Connectors

Fig 7, 33, 33.1, 34, 34HP, 36, 36HP, 37, 3616 and Fig 3716 Flanged Strainers Installation and Maintenance Instructions

BTM7, BTS7 and BTS7.1 Stainless Steel Thermostatic Clean Steam Traps

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats

S and SF Inverted Bucket Steam Traps

Manual Actuated Boiler Blowdown Valves

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

MF2M Monnier Miniature Compressed Air Filter

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

USM21 Sealed Bimetallic Steam Trap for use with Pipeline Connectors Installation and Maintenance Instructions

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

MFP14-PPU (Vented) Automatic Packaged Pump Units

CS10-1 Stainless Steel Clean Steam Separator

Spirax Compact FREME Flash Recovery Energy Management Equipment

SRV66 Sanitary Pressure Reducing Valve

M10HTi ISO Tobacco Ball Valve Screwed, SW, BW and Flanged versions

AVS32 Stainless Steel Air Vent for Steam Systems Installation and Maintenance Instructions

BT6-B Sanitary Balanced Pressure Thermostatic Steam Trap

TD62LM and TD62M Thermodynamic Steam Traps with Replaceable Seats Installation and Maintenance Instructions

M33F ISO, M33S ISO and M33V ISO Ball Valves Installation and Maintenance Instructions

SCA Series Inverted Bucket Steam Traps

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

Airodyn, BRair and BRoil Compressed Air Drain Traps

ML3M Monnier Miniature Compressed Air Lubricator

BPT13 Balanced Pressure Thermostatic Steam Traps

FT53, IFT53, FT54, IFT54, FT57 and IFT57 Ball Float Steam Traps - DIN

UBP32 Sealed Balanced Pressure Thermostatic Steam Trap for use with PC_ Pipeline Connectors Installation and Maintenance Instructions

CA10S, CA14 and CA14S Air and Gas Traps

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

SA Control Valve types: BM, BMF, BX, SB, NS, KA, KB, KC (Normally open) BMRA, BMFRA, BXRA, SBRA, NSRA, KX, KY (Normally closed)

TW Temperature Control Valve

Spirax SafeBloc TM DBB3 Double Block and Bleed Bellows Sealed Stop Valve. 1. Safety information. 2. General product information. 3.

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

APT14, APT14HC and APT14SHC Spares 2

BCV31 DN40 - Blowdown Control Valve

M70i ISO and M80i ISO Stainless Steel Ball Valves for Sanitary Systems Installation and Maintenance Instructions

BTD52L Thermodynamic Steam Trap Installation and Maintenance Instructions

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

FTC62 and FTS62 Ball Float Steam Traps Installation and Maintenance Instructions

SRV2S Pressure Reducing Valve

Type 130 and HL10 'Safeguard High Limit Control' Installation and Maintenance Instructions

FT43, FT44, FT46 and FT47 Ball Float Steam Traps Installation and Maintenance Instructions

Thermocirc Installation and Maintenance Instructions

M111 Spiraflo Transducer

BCV31 DN20 - Blowdown Control Valve

TD10, TD52M and TD259 Thermodynamic Steam Traps Installation and Maintenance Instructions

FT16 Ball Float Steam Trap Installation and Maintenance Instructions

QuickHeat TM Packaged Heat Exchanger Solutions

Vane Flow Switches Colima FLU Series

CA16 and CA16S-14 Air and Gas trap Installation and Maintenance Instructions

BRV71 and BRV73 Pressure Reducing Valves

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

MPC1M, MPC2M and MPC2AM Monnier High Efficiency Compressed Air Filter / Regulators

BCVi43 Blowdown Control Valve

Fig 1, Fig 12, Fig 13, Fig 14, Fig 16 and Fig 16L Strainers Installation and Maintenance Instructions

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

LP31 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

BDV60 Blowdown Vessel Installation and Maintenance Instructions

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

SRV461S and SRV463S Stainless Steel Direct Acting Pressure Reducing Valves

STERI-TROL Clean Service 'S' Series Two-port Control Valves DN15 (½") to DN100 (4")

LP10-4 Level Probe. 1. Safety information. 2. General product information. 3. Installation. 4. Wiring. 5. Maintenance IM-P402-92

Transcription:

1280051/2 IM-P128-13 ST Issue 2 PC10HP Pipeline Connector (ASME 600) Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Spare parts and Maintenance Copyright 2014 IM-P128-13 ST Issue 2 1 Printed in GB

1. Safety information Safe operation of these products can only be guaranteed if they are properly installed, commissioned, used and maintained by qualified personnel (see Section 1.11) in compliance with the operating instructions. General installation and safety instructions for pipeline and plant construction, as well as the proper use of tools and safety equipment must also be complied with. 1.1 Intended use Referring to the Installation and Maintenance Instructions, product markings and Technical Information Sheet, check that the product is suitable for the intended use / application. These products comply with the requirements of the European Pressure Equipment Directive 97 / 23 / EC and all fall within category 'SEP'. It should be noted that products within this category are required by the Directive not to carry the mark. i) These products have been specifically designed for use on steam, air or condensate / water, which is in Group 2 of the above mentioned Pressure Equipment Directive. The products' use on other fluids may be possible but, if this is contemplated, Spirax Sarco should be contacted to confirm the suitability of the product for the application being considered. ii) Check material suitability, pressure and temperature and their maximum and minimum values. If the maximum operating limits of the product are lower than those of the system in which it is being fitted, or if malfunction of the product could result in a dangerous overpressure or overtemperature occurrence, ensure a safety device is included in the system to prevent such over-limit situations. iii) Determine the correct installation situation and direction of fluid flow. iv) Spirax Sarco products are not intended to withstand external stresses that may be induced by any system to which they are fitted. It is the responsibility of the installer to consider these stresses and take adequate precautions to minimise them. v) Remove protection covers from all connections, where appropriate, before installation on steam or other high temperature applications. 1.2 Access Ensure safe access and if necessary a safe working platform (suitably guarded) before attempting to work on the product. Arrange suitable lifting gear if required. 1.3 Lighting Ensure adequate lighting, particularly where detailed or intricate work is required. 1.4 Hazardous liquids or gases in the pipeline Consider what is in the pipeline or what may have been in the pipeline at some previous time. Consider: flammable materials, substances hazardous to health, extremes of temperature. 1.5 Hazardous environment around the product Consider: explosion risk areas, lack of oxygen (e.g. tanks, pits), dangerous gases, extremes of temperature, hot surfaces, fire hazard (e.g. during welding), excessive noise, moving machinery. 1.6 The system Consider the effect on the complete system of the work proposed. Will any proposed action (e.g. closing isolation valves, electrical isolation) put any other part of the system or any personnel at risk? Dangers might include isolation of vents or protective devices or the rendering ineffective of controls or alarms. Ensure isolation valves are opened and closed progressively to avoid system shocks. 2 IM-P128-13 ST Issue 2

1.7 Pressure systems Ensure that any pressure is isolated and safely vented to atmospheric pressure. Consider double isolation (double block and bleed) and the locking or labelling of closed valves. Do not assume that the system has depressurised even when the pressure gauge indicates zero. 1.8 Temperature Allow time for temperature to normalise after isolation to avoid the danger of burns. 1.9 Tools and consumables Before starting work ensure that you have suitable tools and/or consumables available. Use only genuine Spirax Sarco replacement parts. 1.10 Protective clothing Consider whether you and / or others in the vicinity require any protective clothing to protect against the hazards of, for example, chemicals, high / low temperature, radiation, noise, falling objects, and dangers to eyes and face. 1.11 Permits to work All work must be carried out or be supervised by a suitably competent person.installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post 'warning notices' if necessary. 1.12 Handling Manual handling of large and / or heavy products may present a risk of injury. Lifting, pushing, pulling, carrying or supporting a load by bodily force can cause injury particularly to the back. You are advised to assess the risks taking into account the task, the individual, the load and the working environment and use the appropriate handling method depending on the circumstances of the work being done. 1.13 Residual hazards In normal use the external surface of the product may be very hot. If used at the maximum permitted operating conditions the surface temperature may reach temperatures in excess of 425 C (797 F). Many products are not self-draining. Take due care when dismantling or removing the product from an installation (refer to 'Maintenance instructions'). 1.14 Freezing Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point. 1.15 Disposal Unless otherwise stated in the Installation and Maintenance Instructions, this product is recyclable and no ecological hazard is anticipated with its disposal providing due care is taken. 1.16 Returning products Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to Spirax Sarco they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous. IM-P128-13 ST Issue 2 3

2. General product information Steam trap options: - UBP32 - UTD30L - UTD30H - UTDS46M - UTD52L - UIB30 - UIB45 - UFT32 - USM21 and - USM32 The universal trap gaskets are supplied with the trap Fig. 1 The PC10HP has been designed for use with the above listed steam trap options 2.1 General description The PC10HP pipeline connector is designed for use with the above listed swivel connector steam traps up to the maximum pressure / temperature limitations of the selected steam trap. The connector can be fitted into any vertical or horizontal pipeline and the trap can also be rotated through 360º to ensure their correct orientation for operation. The principle is that the pipeline connector can be fitted into the pipeline without the trap fitted and the trap is connected afterwards using just two bolts. The trap can be simply and quickly removed / replaced to minimise system downtime and reduce maintenance resource. Standards These products fully comply with the requirements of the European Pressure Equipment Directive 97 / 23 / EC. Certification This product is available with certification to EN 10204 3.1. Note: All certification / inspection requirements must be stated at the time of order placement. Note: For additional information see the following Technical Information sheet TI-P128-10. 2.2 Sizes and pipe connections Condensate inlet / outlet DN15, DN20 and DN25 ½", ¾" and 1" screwed BSP or NPT Socket weld ends to ASME B 16.11 / BS 3799 Class 3000. Flanged versions are also available upon request. Please contact Spirax Sarco for further details. 2.3 Kv values Size DN15 DN20 DN25 Kv 1.1 1.1 1.1 For conversion: Cv (UK) = Kv x 0.963 Cv (US) = Kv x 1.156 4 IM-P128-13 ST Issue 2

2.4 Pressure / temperature limits (ISO 6552) Temperature C 0 200 400 600 800 1000 1200 1400 425 300 Pressure psi g 200 Steam 100 saturation curve 0 0 20 40 60 80 Pressure bar g The product must not be used in this region. 99.3 700 600 500 400 300 200 100 Temperature F Notes: - If flange connections are fitted then these will limit the maximum design conditions of the pipeline connector. - The maximum operating limits of the complete assembly will be dictated by the steam trap of choice. Reference the specific steam trap Technical Information sheet for its maximum pressure / temperature limitations. Body design conditions ASME Class 600 PMA Maximum allowable pressure 99.3 bar g @ 38 C (1 440 psi g @ 100 F) TMA Maximum allowable temperature 425 C @ 56 bar g (797 F @ 812 psi g) Minimum allowable temperature 0 C (32 F) PMO Maximum operating pressure 64 bar g @ 281 C (928 psi g @ 538 F) for saturated steam service TMO Maximum operating temperature 425 C @ 56 bar g (797 F @ 812 psi g) Minimum operating temperature 0 C (32 F) Note: For lower operating temperatures consult Spirax Sarco PMOB Maximum operating backpressure should not exceed 80% of the upstream pressure Designed for a maximum cold hydraulic test pressure of 149 bar g (2 161 psi g) 2.5 Dimensions / weights (approximate) in mm and kg Size A Weight ½" 61.5 0.6 ¾" 73.5 0.7 1" 90.0 0.7 ä A ä IM-P128-13 ST Issue 2 5

3. Installation Note: Before actioning any installation observe the 'Safety information' in Section 1. There are a number of criteria which must be satisfied to ensure that the swivel connector trap will operate correctly and ensure effective condensate removal. Referring to the Installation and Maintenance Instructions, product markings and Technical Information Sheet, check that the product is suitable for the intended installation: 3.1 Check materials and maximum pressure / temperature values. If the maximum operating limit of the product is lower than that of the system in which it is being fitted, ensure that a safety device is included in the system to prevent overpressurisation. 3.2 The correct steam trap and end connection must be selected to meet the system design conditions. 3.3 Steam trap connector bolts are supplied with the selected steam trap. 3.4 The joint between the PC10HP and trap is sealed with high integrity spirally wound gaskets. During installation the gasket faces must be protected from damage caused by weld splatter, knocks, etc.. to the trap gasket face. Hence care must be taken when installing the PC10HP into the pipework. It is recommended that the trap is installed immediately the PC10HP is in the pipework. Alternatively, the trap can be joined to the PC10HP prior to installation. 3.5 Determine the correct installation situation and direction of fluid flow. The PC10HP must be installed with flow in the direction of the arrow. Flow can be horizontal (either direction), vertical or inclined. The flow direction is clearly marked on the trap body or pipeline connector. Caution: The connection face for the swivel connector steam trap of choice must always be in the vertical plane unless stated on the product specific steam trap Installation and Maintenance Instructions provided with the product. 3.6 Remove protection covers from all connections, where appropriate, before installation on steam or other high temperature applications. 3.7 Suitable isolation valves must be installed to allow for safe maintenance and trap replacement. Where the trap discharges into a closed return system a non-return valve should be fitted downstream to prevent back flow. 3.8 Always open isolation valves slowly until normal operating conditions are achieved this will avoid system shocks. Check for leaks and correct operation. 3.9 Always ensure the correct tools, safety procedures and protective equipment are used at all times. 3.11 When a socket weld version is being installed the welding should be carried out to an approved procedure of a recognised standard. Guidance instructions regarding welding socket weld versions are provided in Section 3.12 Notes: 1. If the trap is to discharge to atmosphere, ensure that it is to a safe place. The discharging fluid may be at a temperature of 100 C (212 F). 2. After installation it is recommended that the PC10HP pipeline connector is insulated to minimise radiated heat losses and to protect personnel from burns risk. Please note that there are some trap types that should not be insulated. 6 IM-P128-13 ST Issue 2

3.12 Welding into pipeline of socket weld variants A universal weld procedure covering the requirements of different national and international standards and practices is difficult to provide - specifically regarding the welding procedure, welding conditions (run number, consumable size, current, voltage, polarity), storage of consumables and make / type of consumables due to the abundance of appropriate consumable suppliers. Therefore, this is only advice based on British standards to be used for guidance on the essential requirements of welding socket weld pipeline connectors into the pipeline. This will allow a user to select an appropriate weld procedure from those available to that user. This advice is not intended to be a substitute for a weld procedure: it is for guidance only. The welding of pipeline connector DN15, DN20, DN25 socket weld to pipe DN15, DN20 and DN25 Schedule 80 Parent material(s) Description PC10HP - Austenitic stainless steel with minimum tensile strength up to and including 485 N/mm². Pipe - Carbon steel with minimum tensile strength up to and including 430 N / mm². Parent material(s) dimensions DN15 DN20 DN25 PC10HP Pipe PC10HP Pipe PC10HP Pipe Thickness (mm) 8.85 3.73 5.50 3.91 5.0 4.55 O / D (mm) 39.00 21.30 39.00 26.70 45.0 33.40 Pipe is to BS 1600 Schedule 80 Specification(s) ASTM A351 CF8 - PC10HP ASTM A106 Gr. B - pipe Material group(s) R - PC10HP A1 - Pipe Joint type Socket joint to ANSI B16.11 Class 3000 lb (This is equivalent to BS 3799) Welding process(es) Manual Metal Arc (MMA) Welding position(s) All: site welded Weld preparation Dimensioned sketch Diametrical clearance 1.0 mm maximum PC10HP 1.5 mm approximately Pipe t Continued on page 8 Ref.- BS 2633 : 1987 : Section 3.1 and Fig. 9 IM-P128-13 ST Issue 2 7

3.12 Welding into pipeline of socket weld variants continued Welding consumables Filler material: - Composition - Low C: 23% Cr: 12% Ni: Specification - BS 2926: 1984: 23-12 L BR Shielding gas / flux: Not applicable Parent material temperature Preheat temperature Only required when ambient is below 5 C then 'warm to touch' Method of preparation and cleaning Socket : As supplied and wire brushed. Pipe : Mechanically cut and wire brushed. Additional information 1. Fit-up using tack welds. Run sequence and completed weld dimensions Sketch Interpass temperature Not applicable Post-weld heat treatment None required This edge is not to be completely melted away 1.4t minimum 1.4t minimum PC10HP Pipe Ref.- BS 806 : 1990 : Section 4 : Clause 4.7.3 4. Commissioning After installation and maintenance ensure that the system is fully functional. Carry out tests on any alarms or protective devices. 5. Spare parts and Maintenance Please note that there are no spare parts for the PC10HP pipeline connector. If spare parts are required for the steam trap that is connected to the PC10HP we recommend that you use the product specific Installation and Maintenance Instructions for that particular product. 8 IM-P128-13 ST Issue 2