Certification Exhibit FCC ID: R7PIWRS4. FCC Rule Part: ACS Report Number: W03.11.A

Similar documents
WELCOME TO THE FUTURE OF TELEVISION. User Manual

Read This First. SurfLink Media Controls Overview. Back View

Scoreboard Operator s Instructions MPCW6 Control

User Guide. 2 Player Basketball Game

SVEA II GSM Connector User Manual

Puck Installation Guide

FireHawk M7 Interface Module Software Instructions OPERATION AND INSTRUCTIONS

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Wireless Belt Pack BP Conductor with Radio Transmit

Resusci Anne Simulator

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Wireless Belt Pack BP Conductor Jack with Radio Transmit & Volume Control

PTP 800 SPLIT-MOUNT SOLUTION

PROGRAMMER OPERATIONS MANUAL

BASnet LightiView Install Guide

User Manual. Bluetooth Pedometer. AmericanPumpkins. version:1.0

MOTOROLA PTP 800 LICENSED ETHERNET MICROWAVE

ASSEMBLY INSTRUCTIONS

MEDIA 2 OPERATIONS MANUAL

PitchTracker Softball User Guide

WARNING: Read this manual in it s entirety before using this product. Improper use could result in damage to the product or lead to injury.

3M Electrial Markets Division EMS. Electronic Marker System

xx TA-CMI. User Manual

SonoMeter 30 Energy Meters

SAR COMPLIANCE REPORT

Domino DUEMMEGI. Domino. Communication Interface DFTS User s Manual. Release September 2007

PitchTracker User Guide. Model: DKPT01 User Guide

Datasheet: K-30 ASCII Sensor

Quick Start Installation Guide

PointsPlus U S E R G U I D E

IDeA Competition Report. Electronic Swimming Coach (ESC) for. Athletes who are Visually Impaired

OPERATING INSTRUCTIONS FOR MODEL VSBX

Scoreboard Operator s Instructions MPCX2 Baseball Control

SkillGuide. User Guide. English

Pedometer with Speed Sensor. User Manual

Residential Ultrasonic Gas Meters

Baby Basketball. Model Number 74069

PRODUCT MANUAL. Diver-MOD

SMART Oxygen Analyzer. User Manual

INSTRUCTION MANUAL. Pedometer Downloadable Model: HJ-323U ENGLISH

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

Aeroqual AirCal 1000 User Guide

WAVE 300 XL. User Instructions

HumiSys HF High Flow RH Generator

Batter Up & Bowl Sports Arena

Programmable pressure and temperature transmitters PTM/RS485

Connect with Confidence NO POWER NO PROBLEM

REMOTE CONTROL OPERATIONS MANUAL

REMOTE CONTROL OPERATIONS MANUAL

WARNING: Read this manual in it s entirety before using this product. Improper use could result in damage to the product or lead to injury.

ATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Visualize Nitrogen Gas Consumption

SAUTER flexotron 800 heating. List of network variables for Modbus communication. Manual P A P

AMS 6915 Board mount pressure sensor with digital output (I²C)

AMB MOISTURE BALANCE AMB 50, AMB 110 and AMB 310. Operating Manual

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

RACE RESULT SYSTEM DATA SHEETS. Decoder. Passive Antenna. Passive Transponders. Active Extension. Active Transponders.

Additel 761 Automated Pressure Calibrators Selection Guide

Programmable pressure and temperature transmitters PTM/RS485

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

OPERATING INSTRUCTIONS FOR

Parametrable / Programmable Pressure Transmitter

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

Fixed Ozone Monitor User Manual December, Automatikprodukter

Programmable Submersible Level Transmitters

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

CSBUOY-DT INSTRUCTION MANUAL

ANTARES PUNTOS MULTISPORT SCOREBOAD

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

Additel 761 Automated Pressure Calibrators

IBU3 Manual Addendum 1

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

AN-140. Protege WX SALLIS Integration Application Note

SonoSelect 10 and SonoSafe 10 energy meters

Additel 761 Automated Pressure Calibrators Selection Guide

Additel 761 Automated Pressure Calibrators

Additel 761 Automated Pressure Calibrators

OWNER S MANUAL. GLF-125 Golf GPS. The Whistler Group, Inc. - Corporate Offices 3604 NW Frontage Road Bentonville, AR

A full user manual detailing the additional features of the Neo XS is available for downloading at

Owner s Manual. Model H4685

Test Report #: Date: June 21, 2005

User Manual. 3BaysGSA PRO - Golf Swing Analyzer 10,000 DATA POINTS CAPTURED PER SWING. [For Android User]

Interactive Fitness Holdings Expresso S3 Recumbent Bike User Guide

Blood Pressure Monitor Instruction Manual

User Guide CyberCycle. User Guide

Lam Rainbow and TCP Product Status Checklist. System Type: Poly Etcher System Model: 4420 D.O.M.:

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

WARNINGS. Do not mix alkaline, standard (carbon-zinc), or rechargeable (Ni-Cd, Ni-MH, etc) batteries.

SPECIFICATION. Product Name : MA450 Storm 5in1 Permanent Mount Antenna LTE MIMO*2 + WIFI MIMO*2 + GNSS

Aquatic Rescue Command Center

Additel 780 Series Pressure Controller

Residential Meters. Available innov8 Outputs 900 MHz Radio Virtual Network 3W Standard AMR 2W AMR 2W Standard Touchpad Scalable Pulse 4-20mA SCADA

Flow and Energy Measurement F-5400 THERMAL MASS FLOW METER

Doc. no.dit om005 PRODUCT NAME. IO-Link/ELECTRO-PNEUMATIC REGULATOR. MODEL / Series / Product Number ITV*0*0-IO****-X395

MEDIA 2 OPERATIONS MANUAL

5 series Blood Pressure Monitor

CADWELL INDUSTRIES, INC. TEST REPORT FOR THE ELECTRONEURODIAGNOSTIC MONITORING SYSTEM, EASY WIRELESS EEG

SMART Carbon Monoxide Analyzer. User Manual

Configuring Bidirectional Forwarding Detection for BGP

Transcription:

Certification Exhibit FCC ID: R7PIWRS4 FCC Rule Part: 15.247 ACS Report Number: 09-0412.W03.11.A Manufacturer: Cellnet Technology Inc. Model: Gridstream DCIWR Manual 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598

Gridstream Series IV IWR Radio Data Sheet General The Gridstream Series IV Integrated WanGate Radio (IWR) provides a basis for a powerful RF wireless mesh network for remote data collection. The radio provides full two-way peer-to-peer communication to all devices within the network. The Gridstream Series IV IWR also offers advanced functionality, such as individual message prioritization, additional memory for localized intelligence, and a programming language Device Control Word (DCW) used to provide interface and control to distributed automation equipment. The Gridstream Series IV IWR has one RS-232 serial port for the LAN Packet Port (LPP) and one RS-232/485 serial port for the Transparent Packet Port (TPP). The LAN Packet Protocol Port is used to communicate to devices that use the Gridstream IWR LAN Packet Protocol, such as a PC with configuration or diagnostic software. The Transparent Packet Port is a general-purpose data port that is used to transport byte-oriented data, such as DNP 3.0, Modbus, or DF1. Figure 1. Gridstream Series IV IWR Radio Landis+Gyr Confidential Information 98-0064 Rev AB 1

Gridstream Series IV IWR Radio Data Sheet Landis+Gyr Gridstream Series IV IWR Radio Usage The Gridstream Series IV IWR Radio, P/N 26-1309, was engineered specifically for varied needs of residential and commercial applications. It enables access to the RF mesh network using a standard RS-232 connection. Useful features of the Gridstream Series IV IWR Radio include: User-friendly interface via RadioShop for configuring the Gridstream Series IV IWR Radio. The interface provides: Current status information Logical configurations for: LPP port TPP port Simultaneous connections per RS-232 interface by: LPP applications TPP applications 2 98-0064 Rev AB Landis+Gyr Confidential Information

Landis+Gyr Gridstream Series IV IWR Radio Data Sheet Regulatory Compliance FCC (Part 15.247) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Landis+Gyr for compliance could void the user s authority to operate the equipment. FCC Class B This equipment has been tested and found to comply with the limits for Class B digital service, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residental installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to connect the interference by one or more of the following measures: Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technican for help RF Exposure The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 22cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Landis+Gyr Confidential Information 98-0064 Rev AB 3

Gridstream Series IV IWR Radio Data Sheet Landis+Gyr Gridstream Series IV IWR Radio Specifications Electrical (General) Table 1. General Series IV IWR Specification Input Voltage Range Input Current (in transmitting mode) Input Current (in receiving mode) RF Frequency Range Channel Spacing RF Data Rate 6-28VDC 320 ma typical (12 VDC operation) 38 ma typical (12 VDC operation) 902-928 MHz 100 khz, 300 khz (depending on mode) 9.6-38.4 Kbps (100 khz channels), 9.6-115.2 Kbps (300 khz channels) Receiver Sensitivity (at 10% packet error rate) Co-channel rejection Adjacent Channel Rejection Alternate Channel Rejection -112 dbm (9.6 Kbps), -102 dbm (115.2 Kbps) typical 10 db Typical 30 db Typical 45 db Typical Transmitter Output Power (at Antenna Connector) Modulation Type Modulation Index Out-of-band Spurious Emissions 126 mw (21 dbm)/316 mw (25 dbm)/1 Watt (30 dbm) 2-FSK, GFSK 1 <-70 dbc Antenna Requirements Type Gain Vertically polarized, omnidirectional < 5 dbi Processing CPU Clock Speed SRAM Memory FLASH Memory M16C/65P 14.7456 MHz 47 kbytes internal + 512 kbytes external 768 kbytes internal + 1 Mbytes external Data Ports/Formats Serial Interface Protocol Parity Data Bits Stop Bits Duplex LAN Packet Port RS-232C; DB9 female; 1200 to 115,200 bps Gridstream LAN Packet Protocol None 8 1 Full Transparent Port RS-232C/RS-485; DB9 Female; 300 to 38,400 bps Any Asynchronous Byte-Oriented Protocol None 7or8 1or2 Full 4 98-0064 Rev AB Landis+Gyr Confidential Information

Landis+Gyr Gridstream Series IV IWR Radio Data Sheet Table 1. General Series IV IWR Specification(Continued) Mechanical Enclosure Power Connection Dimensions Weight Antenna Operating Temperature Range Storage Temperature Range Extruded Aluminum Molex Mini-fit 4.250 W x 5.770 D x 1.720 H 1.10 lbs SMA Type, Female -40 to 85 C -40 to 85 C Contact Information: Technical Support: 1.888.390.5733 Internet: www.landisgyr.com E-mail: solutionsupport.na@landisgyr.com Landis+Gyr Confidential Information 98-0064 Rev AB 5

Gridstream Series IV IWR Radio Data Sheet Landis+Gyr 6 98-0064 Rev AB Landis+Gyr Confidential Information