Technical Information Oxymax COS22D/COS22

Similar documents
Oxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving

Oxymax COS22/22D. Technical Information

Oxymax H COS21D. Technical Information

Oxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor

Oxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications

Oxymax COS61/COS61D. Technical Information

COM280. Technical Information. Oxygen measurement Battery-driven pocket meter for dissolved oxygen measurement

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Operating Instructions Oxymax COS22D

Technical Information Conducal CLY421

Technical Information Cleanfit CUA451

Indumax CLS54D. Operating Instructions

STERILIZABLE DISSOLVED OXYGEN SENSORS

Dissolved Oxygen and measurement possibilities. Berno Lüpkes, 15 th March 2017

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

SITRANS P measuring instruments for pressure

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

ph measuring system for hygienic process applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Pressure Measurement Single-range transmitters for general applications

Oxygen Measurement Systems High Reliability and Wide Application Coverage

Precision pressure sensor Basic version Model CPT6020

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

Operating Instructions. Oxymax COS51D. Digital sensor for dissolved oxygen With Memosens technology BA00413C/07/EN/

STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE

Pressure Measurement Single-range transmitters for general applications

OUS31. Technical Information

RTX 1000H Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control. Features

Contactless. Digital. MEMOSENS. The Industry Standard for Sensors

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

High-performance submersible pressure transmitter For level measurement Model LH-20

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

How to specify a product. Process Sensors and Mechanical Instruments

High-performance submersible pressure transmitter For level measurement Model LH-20

SITRANS. Pressure transmitter SITRANS P, Z series for gauge and absolute pressure. Introduction. Safety instructions 2.

General Specifications

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Pneumatic high-pressure controller Model CPC7000

Operating manual. TA 197 Oxi. Dissolved Oxygen Depth Armature

DISSOLVED OXYGEN SENSOR BT34i

Operating Instructions. Oxymax W COS41. Dissolved oxygen sensor. BA284C/07/en/

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

x act i Precision- Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

High-performance submersible pressure transmitter For level measurement Model LH-20

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

JUMO dtrans p30 Pressure Transmitter

UNIK 5600/5700 Marine Certified Pressure Sensing Platform

High-performance submersible pressure transmitter For level measurement Model LH-10

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

SS32L Dissolved O 2 Probe

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure Transmitter P41

Improve Process Reliability

Technical Data. Dimensions

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

L3 Pressure and Level transmitter

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

OPTIBAR P 1010 C Technical Datasheet

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

FAS-W. Features. Applications. Automatic condensation hygrometer

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Pool and Spa. Water Testing

9700 Transmitter Submersible hydrostatic level transmitter

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

Optical Dissolved Oxygen Meter

Armatures for analytical probes

ED 701 Hygenic Pressure Transmitter

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

Dextens Thermo Conductivity Sensors. Type 52101, 54101, 55101

Pneumatic high-pressure controller Model CPC7000

HI 2314 HI 2315 HI 23151

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Technical Data. General specifications. Rated operating distance s n 5 mm

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

ZUERCHER BRCeb/BSCeb Series

Turbimax CUS31. Technical Information

OxyProbe II Instruction Manual

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

Technical Data Sheet MF010-O-LC

EC214 EC215 - EC215R Bench Conductivity Meters

Dr. Thiedig DIGOX 5 CO 2. In-line measurement of CO 2 for constant product quality. Anlagen- und Analysentechnik

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

Operating Instructions Flowfit CUA252

Tank Blanketing Regulators

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

PRODUCT SHEET. Order probe only as RXPROBE02

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Differential Pressure Transmiter

The New PHD 4 Portable Helium Detector

Transmitter CS 21 Operation Manual

Expert Hydrostatic Level Transmitters

OXY Integral. INTERCON ENTERPRISES INC Tel: Fax: Internet:

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Transcription:

TI00446C/07/EN/04.15 71306865 Products Solutions Services Technical Information Oxymax COS22D/COS22 Digital or analog sensor for the measurement of oxygen Sensor with long-term stability for frequent sterilizations and autoclavability Application Pharmaceutics and biotechnology Process control in enzyme production Control of culture processing Beverage industry Chemical industry Water treatment Boiler feedwater WFI (water for injection) Inertization Residual oxygen measurement in processes Your benefits Sensor version suitable for pharmaceutical industry: Stainless steel 1.4435 (AISI 316L) Sterilizable and autoclavable Application-specific versions: Sensor for standard applications, e.g. for fermenter control Trace sensor, e.g. for use in the power station sector and for the beverage industry (CO2-compatible sensor) Very versatile: Standard process connection Pg 13.5 Installation possible in standard ph assemblies Short response time: t 98 < 60 s Integrated temperature sensor Other advantages of Memosens technology Maximum process safety thanks to non-contact, inductive signal transmission Data security thanks to digital data transmission Very easy to use as sensor data saved in the sensor Recording of sensor load data in the sensor enables predictive maintenance

Function and system design Measuring principle Application in gaseous media Measuring system The oxygen molecules that diffuse through the membrane are reduced at the cathode to hydroxide ions (OH-). At the anode, silver is oxidized to silver ions (Ag+) (this forms a silver halide layer). A current flows due to the electron donation at the cathode and the electron acceptance at the anode. Under constant conditions, this flow is proportional to the oxygen content of the medium. This current is converted in the transmitter and indicated on the display as an oxygen concentration in mg/l, µg/l, ppm, ppb or Vol%, as a saturation index in % SAT or as an oxygen partial pressure in hpa. The trace sensor version can be used in gaseous media, such as for inertizations and quality control in the trace range. Process monitoring in gaseous media can be performed with the standard sensor. The measured value is displayed in Vol% or as oxygen partial pressure in hpa. Sensors that are used in dry media consume more electrolyte and must therefore be maintained more frequently. A complete measuring system comprises: An Oxymax COS22 or Oxymax COS22D oxygen sensor A transmitter, see table An appropriate measuring cable, see table Optional: an assembly, e.g. permanent installation assembly CPA442, flow assembly CPA240, or retractable assembly CPA875 Transmitter COS22D- standard, trace COS22- standard COS22- trace Liquiline CM44x, cable: CYK10 - - Liquiline CM42, cable: CYK10 - - Liquisys COM2x3 -, cable: COK21 - Third-party provider Memosens partner Possible, cable: COK21 Possible, cable: COK21 4 1 3 2 1 Example of a measuring system with COS22D-*1 1 Liquiline CM42 2 Measuring cable CYK10 3 Digital oxygen sensor Oxymax COS22D-*1 4 Permanent installation assembly CPA442 A0022853 2 Endress+Hauser

1 2 4 3 2 Example of a measuring system with COS22-*1 1 Retractable assembly CPA875 2 Transmitter Liquisys COM253 3 Measuring cable COK21 4 Oxygen sensor COS22 A0024029 Dependability Reliability Memosens MEMO SENS Memosens makes your measuring point safer and more reliable: Non-contact, digital signal transmission enables optimum galvanic isolation Completely watertight Can even be connected under water No contact corrosion Measured value not affected by moisture. Correct transmission of even the smallest values, e.g. from amperometric sensors. Sensor can be calibrated in a lab, thus increasing the availability of the measuring point in the process Intrinsically safe electronics mean operation in hazardous areas is not a problem. Predictive maintenance thanks to recording of sensor data, e.g.: Total hours of operation Hours of operation with very high or very low measured values Hours of operation at high temperatures Number of steam sterilizations Sensor condition Maintainability Easy handling Sensors with Memosens technology have an integrated electronics unit that stores calibration data and other information (e.g. total operating hours and operating hours under extreme measuring conditions). Once the sensor has been connected, the sensor data are transferred automatically to the transmitter and used to calculate the current measured value. As the calibration data are stored Endress+Hauser 3

GN/YE Oxymax COS22D/COS22 in the sensor, the sensor can be calibrated and adjusted independently of the measuring point. The result: Easy calibration in the measuring lab under optimum external conditions increases the quality of the calibration. Pre-calibrated sensors can be replaced quickly and easily, resulting in a dramatic increase in the availability of the measuring point. Maintenance intervals can be defined based on all stored sensor load and calibration data and predictive maintenance is possible. The sensor history can be documented on external data carriers and in evaluation programs. Thus, the current application of the sensors can be made to depend on their previous history. Safety Data security thanks to digital data transmission Memosens technology digitizes the measured values in the sensor and transmits the data to the transmitter using a non-contact connection that is free from potential interference. The result: Automatic error message if sensor fails or connection between sensor and transmitter is interrupted Immediate error detection increases measuring point availability Input Measured values Measuring ranges Dissolved oxygen [mg/l, µg/l, ppm, ppb or % SAT or hpa] Temperature [ C, F] Measuring ranges apply for 20 (68 F) and 1013 hpa (15 psi) Measuring range Optimum operational range 1) COS22/22D-*1 COS22/22D-*3 COS22D-*4 0.01 to 60 mg/l 0 to 600 % SAT 0 to 1200 hpa (0 to 6 psi) 0 to 100 Vol% 0.001 to 10 mg/l 0 to 120 % SAT 0 to 250 hpa (0 to 6 psi) 0 to 25 Vol% 0.01 to 20 mg/l 0 to 200 % SAT 0 to 400 hpa (0 to 6 psi) 0 to 40 Vol% 0.001 to 2 mg/l 0 to 20 % SAT 0 to 40 hpa (0 to 6 psi) 0 to 4 Vol% 1) Applications in this range guarantee a long service life and minimum maintenance Power supply Electrical connection COS22D The electrical connection of the sensor to the transmitter is performed using the measuring cable CYK10. GY GND YE Com B GN WH BN Com A + 3 Measuring cable CYK10 A0024019 4 Endress+Hauser

COS22 A multi-core COK21 measuring cable is used for the electrical connection of the sensor to the transmitter. Assignment External shield Active internal shield (NTC temp. sensor) Cathode Anode NTC temp. sensor Terminal S 12 90 91 11 GN / YE YE PK BN BU 4 Measuring cable COK21 A0005583-EN The polarization voltage must be set at the transmitter as follows: Standard measuring range: -650mV Trace measuring range: -550mV The voltage is applied between the working electrode (cathode) and the reference electrode (anode). Performance characteristics Response time From air to nitrogen at reference operating conditions: t 90 : < 30 s t 98 : < 60 s Reference operating conditions Reference temperature: Reference pressure: Reference application: 25 C (77 F) 1013 hpa (15 psi) Air-saturated water Signal current in air COS22/22D-*1 (standard sensor): 40 to 100 na COS22/22D-*3, COS22D-*4 (trace sensor): 210 to 451 na Zero current COS22/22D-*1 (standard sensor): < 0.1 % of the signal current in air COS22/22D-*3, COS22D-*4 (trace sensor): < 0.03 % of the signal current in air Measured value resolution COS22/22D-*1 (standard sensor): 10 ppb in aqueous, 0.2 hpa or 0.02 Vol% in gaseous media COS22/22D-*3, COS22D-*4 (trace sensor): 1 ppb in aqueous, 0.02 hpa or 0.002 Vol% in gaseous media Corresponds to the recommended measured value resolution at the transmitter Maximum measured error COS22/22D-*1 (standard sensor): ±1 % of measuring range + 10 ppb * COS22/22D-*3, COS22D-*4 (trace sensor): ±1 % of measuring range + 1 ppb * * at reference operating conditions Long-term drift < 4 % per month in reference operating conditions 1 % per month in operation with reduced oxygen concentration (< 4 Vol% O 2 ) Influence of the medium pressure Pressure compensation not required Endress+Hauser 5

Polarization time COS22/22D-*1 (standard sensor): < 30 min for 98% signal value, 2 h for 100% COS22/22D-*3, COS22D-*4 (trace sensor): < 3 h for 98% signal value, 12 h for 100% Intrinsic oxygen consumption COS22/22D-*1 (standard sensor): COS22/22D-*3, COS22D-*4 (trace sensor): Approx. 20 ng/h in air at 25 C (77 F) Approx. 100 ng/h in air at 25 C (77 F Operating time of the electrolyte Temperature compensation Theoretical operating time at p O2 = 210 mbar and T=25 C (77 F) COS22/22D-*1 (standard sensor): COS22/22D-*3, COS22D-*4 (trace sensor): > 1.5 years > 3 months COS22D Compensation of the membrane properties takes place in the transmitter between -5 and 90 C (23 to 194 F); above 90 C (194 F), extrapolation takes place Measured variable as partial pressure [hpa] or in Vol%: -5 to 90 C (23 to 194 F) Measured variable as concentration [mg/l]: 0 to 80 C (32 to 176 F) Measured variable as saturation [%SAT]: -5 to 90 C (23 to 194 F) A B C -5 0 80 90 T [ C] 23 32 176 T [ F] 194 A0011887 COS22 Compensation of the membrane properties depending on the transmitter, recommended: 2.4 % per K Installation Installation instructions Installation in suitable assembly is required (depending on the application) NOTICE If the unit is installed without an assembly, there is the danger of rupturing cables or losing the sensor Do not install the sensor suspended from the cable! Installation angle Not permissible! Permissible angle of installation 10 10 Not permissible! 5 Permitted orientations A0005584-EN 6 Endress+Hauser

The sensor must be installed at an angle of inclination of 10 to 170 in an assembly, bracket or appropriate process connection. Recommended angle: 45, to prevent the formation of air bubbles. Inclination angles other than those mentioned are not permitted. Do not install the sensor overhead. Observe the instructions for installing sensors in the Operating Instructions for the assembly used. Environment Ambient temperature range COS22/22D-*1 /3: -5 to +135 C (23 to 275 F), non-freezing COS22D-*4: -5 to +50 C (23 to 120 F), non-freezing Storage temperature 5 to +50 C (20 to 120 F) at 95% relative humidity, non-condensing NOTICE Danger of sensor drying out Store the sensor with the watering cap only (filled with tap water). Degree of protection IP 68 (10 m (33 ft) head of water at 25 C (77 F) over 45 days, 1 mol/l KCl) Humidity 0 to 100%, COS22D: condensating, COS22: not condensating in area of T-82 connection Process Process temperature COS22/22D-*1 /3: -5 to +135 C (23 to 275 F), non-freezing COS22D-*4: -5 to +80 C (23 to 180 F), non-freezing Process pressure Ambient pressure... 12 bar (... 174 psi) absolute Temperature-pressure ratings p [psi] [bar] 174 12 87 6-5 0 80 135 T [ C] 2332 176 275 T [ F] A0028771-EN Minimum flow COS22/22D-*1 (standard sensor): 0.02 m/s (0.07 ft/s) COS22/22D-*3, COS22D-*4 (trace sensor): 0.1 m/s (0.33 ft/s) Chemical resistance Parts in contact with the medium are chemically resistant to: Diluted acids and alkalis Hot water and superheated steam up to max. 135 C (275 F) CO 2 up to 100 %, only with trace sensor COS22/22D-*3 Endress+Hauser 7

NOTICE Hydrogen sulfide and ammonia shorten the operating life of the sensor. Do not use the sensor in applications where it is exposed to hydrogen sulfide or ammonia vapors. Cross-sensitivity COS22/22D-*1/3 Molecular hydrogen causes false low readings and can, in a worst-case scenario, result in total failure of the sensor. No cross interference from hydrogen with the COS22D-*4 version. CIP compatibility Yes (COS22/22D-*1/3) SIP compatibility Yes, max. 140 C (284 F) (COS22/22D-*1/3) Autoclavability Yes, max. 140 C (284 F), max. 30 min. (COS22/22D-*1/3) Mechanical construction Design 1 2 3 4 5 9 8 7 6 A0011869 6 COS22D 1 2 3 4 5 9 8 7 6 A0011868 7 COS22 1 2 3 Plug-in head Thrust collar Sensor shaft 4 5 6 O-ring 8.5 x 1.5 mm Membrane body Shaft sleeve 7 8 9 Glass portion with anode and cathode Process seal 10.77 x 2.62 mm Process connection Pg 13.5 Dimensions 50 (1.97) 120 / 225 / 360 / 420 (4.72 / 8.86 / 14.2 / 16.5)* Pg 13,5 12-0.1 (0.47) A0011881 8 Dimensions in mm (inch) 8 Endress+Hauser

54 (2.13) 120 / 225 / 360 / 420 (4.72 / 8.86 / 14.2 / 16.5)* Pg 13,5 12-0.1 (0.47) A0011886 9 Dimensions in mm (inch) Flow assembly for sensors with Ø 12 mm (accessories) 28 (1.10) 39 (1.54) Ø6 (0.24) 160 (6.30) 30 (1.18) Ø6 (0.24) Ø 29 x 1.5 (1.14 x 0.06) A0015019 10 Dimensions in mm (inch) Weight Depending on the design (length) 0.2 kg (0.44 lbs) to 0.7 kg (1.54 lbs) Materials Parts in contact with medium Sensor shaft (depending on the version) Stainless steel 1.4435 (AISI 316L) Titanium Alloy C22 Electrode combination Process seal Process seal for ATEX/FM/CSA/NEPSI/TIIS Seals/O-rings Membrane body, sealing ring for shaft sleeve Membrane COS22/22D-*1/3: silver / platinum COS22D-*4: silver / gold VITON (FDA-compliant) VITON (not FDA-compliant) VITON (FDA-compliant) Perfluoroelastomer with USP88 Class VI Silicone (FDA-compliant, in compliance with USP87/88 class VI), PTFE, steel mesh Process connection Pg 13.5 Surface roughness R a < 0.38 µm Temperature sensor NTC 22 kω Endress+Hauser 9

Electrolyte COS22/22D-*1 (standard sensor): Slightly alkaline electrolyte COS22/22D-*3 (trace sensor): Neutral electrolyte COS22D-*4 (trace sensor, gold): Slightly alkaline electrolyte Certificates and approvals mark Declaration of Conformity The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EC directives. The manufacturer confirms successful testing of the product by affixing to it the mark. Ex approvals Version COS22D-BA ATEX II 1G / IECEx Ex ia IIC T3/T4/T6 Ga FM/CSA IS/NI Cl.1 Div.1 GP: A-D Version COS22D-NA NEPSI Ex ia IIC T3/T4/T6 Ga Version COS22D-TA TIIS Ex ib IIC T4 Material certificates Manufacturer declaration of FDA compatibility The manufacturer declares the use of FDA-listed materials. Ask your Sales Center for the certificates. Product COS22/22D-****22 COS22Z-*2*2 COS22/22D-****23 COS22Z-*2*3 FDA certificate for Membrane, O-rings, process seal Membrane, O-rings, process seal Membrane, O-rings Membrane, O-rings Hazardous area versions For operation in FDA processes, another FDA-approved seal must be installed before the process seal (e.g. CPA442). Doing so will sufficiently separate the process from the Ex connection. Material test certificate A test certificate 3.1 in accordance with EN10204 is supplied depending on the version ( Product Configurator on the product page). EHEDG Compliance with EHEDG's criteria for hygienic design TÜV Rheinland, Apeldorn, Netherlands Certificate type: Type EL Class I Ordering information Product page www.endress.com/cos22 www.endress.com/cos22d 10 Endress+Hauser

Product Configurator Scope of delivery The navigation area is located on the right of the product page. 1. Under "Device support" click "Configure your selected product". The Configurator opens in a separate window. 2. Select all the options to configure the device in line with your requirements. In this way, you receive a valid and complete order code for the device. 3. Export the order code as a PDF or Excel file. To do so, click the appropriate button at the top of the screen. The scope of delivery comprises: Oxygen sensor with watering cap (filled with tap water) for protecting the membrane Electrolyte, 1 bottle, 10 ml (0.34 fl.oz.) Tool to push out the membrane body Brief Operating Instructions Accessories The following are the most important accessories available at the time this documentation was issued. For accessories not listed here, please contact your service or sales office. Assemblies (selection) Cleanfit CPA875 Retractable process assembly for sterile and hygienic applications For in-line measurement with standard 12 mm sensors for parameters such as ph, ORP and oxygen Product Configurator on the product page: www.endress.com/cpa875 Technical Information TI01168C Flowfit CPA240 ph/redox flow assembly for processes with stringent requirements Product Configurator on the product page: www.endress.com/cpa240 Technical Information TI00179C Unifit CPA442 Installation assembly for food, biotechnology and pharmaceutics With EHEDG and 3A certificate Product Configurator on the product page: www.endress.com/cpa442 Technical Information TI00306C Cleanfit CPA450 Manual retractable assembly for installing 120 mm sensors in tanks and pipes Product Configurator on the product page: www.endress.com/cpa450 Technical Information TI00183C Flow assembly For sensors with Ø 12 mm and length 120 mm Compact stainless steel assembly with low sampling volume Order No. Order No.: 71042404 Measuring cable Cable for COS22D CYK10 Memosens data cable For digital sensors with Memosens technology Product Configurator on the product page: www.endress.com/cyk10 Technical Information TI00118C Endress+Hauser 11

Memosens data cable CYK11 Extension cable for digital sensors with Memosens protocol Product Configurator on the product page: www.endress.com/cyk11 Technical Information TI00118C Cable for COS22 COK21 Cable length 3 m (9.8 ft) Order No. 51505870 Cable length 10 m (33 ft) Order No. 51505868 Zero-point gel COY8 Zero-point gel for oxygen sensors Oxygen-depleting gel for test purposes Product Configurator on the product page: www.endress.com/coy8 Technical Information TI01244C Maintenance kit COS22Z Service Kit, COS22 and COS22D Ordering information: www.endress.com/cos22d under "Accessories/spare parts" www.addresses.endress.com