QUICK START GUIDE CB-950 DATA BUOY PLATFORM

Similar documents
QUICK START GUIDE CB-450 DATA BUOY PLATFORM

QUICK START GUIDE CB-150 DATA BUOY PLATFORM

CB-150 Data Buoy Quick Start Guide

CB-40 Data Buoy Quick Start Guide

CB-50 Data Buoy Quick Start Guide

ENVIRONMENTAL DATA BUOYS

Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL -

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

High-performance submersible pressure transmitter For level measurement Model LH-10

CLIENT NAME: LOCATION: CALM BUOY INSPECTION:

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

OEM Manual. MODEL ½ Digit DRUM SCALE

I.H.S INSTALLATION INSTRUCTIONS

Assembly Instructions. -Cantilever Boat Lifts

SonoMeter 30 Energy Meters

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure Measurement Single-range transmitters for general applications

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

GasSense NDIR User Manual

Low Wind High Yields Series

JUMO dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

Depth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition

WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination

MODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

CSBUOY-DT INSTRUCTION MANUAL

Ocean Observatories Initiative. Coastal & Global Scale Nodes. Hydrogen Safety. OOI Surface Mooring Hydrogen Safety Review

Expert Hydrostatic Level Transmitters

INSTRUCTION MANUAL. January 23, 2003, Revision 0

BUYER S GUIDE AQUAlogger 520

Technical Information Conducal CLY421

NOVALYNX CORPORATION MODEL ANALOG OUTPUT EVAPORATION GAUGE INSTRUCTION MANUAL

RPS900W Redundant Power Supply. Installation Guide.

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

Advantage Lockers & Bike

SITRANS P measuring instruments for pressure

5 Channel Calibrator

Installation, operating and maintenance Instructions for Seemag bypass level indicator

TRANSDUCER KIT 2 INSTALLATION INSTRUCTIONS

NHR-X-X Encore Feed Hoppers

Table of Contents 1 Introduction 2 Technical specifications 3 Included in the delivery 4 Function description 5 Mounting Nortek AOS buoy

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

Model PDT Dewpoint Transmitter

NHR Powder Feed Hopper

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

AUTO PUMP STATUS CENTER

SDX Submersible Depth Transmitter User Manual

Preferred Instruments Danbury, CT USA

User s Guide. Vacuum Controller for liquid delivery systems

FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL

Stand-Alone Bubble Detection System

BUYER S GUIDE AQUAlogger 530WTD

Columbus Instruments

EcoPRO-Series 4-20mA SUBMERSIBLE PRESSURE TRANSMITTER INSTRUCTIONS

AMS 2710 PCB pressure sensor module with V output

Pressure Dump Valve Service Kit for Series 3000 Units

Foundation Products. Poured In Ground Anchor Bolts E1 - E4. Structural Foundations E5 - E12. Copyright 2016 s Industry Inc. SIE-RA-CMP EN

INSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD.

Pressure Dump Valve Service Kit for Series 2300 Units

KEG PUMP. Range of Electric Keg Pumps

Model MTB-ASME Vertical Bladder Tanks

Pressure Measurement Single-range transmitters for general applications

Encore PE 50-lb Feed Hopper

Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks

dtrans O2 01 Two-wire Transmitter for dissolved oxygen (DO)

RM-80 respiration monitor

Climatic Independent Level Sensor LAR

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

DPC-30 DPC-100. Reference Manual

TECHNICAL DATA. Trimpac 257a. September 16, 2013

Lectric Cycles Mid-Drive Electric Motor Installation

SDX Submersible Depth Transmitter User Manual

Security and confidence at height.

GV Standard X-Vent. Setup, Commissioning & Installation Guide

Horizontal Bladder Tanks

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

C-Flow Coriolis Mass Flow Meters

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Variable Area Flow Meters

GG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual

Vertical and Horizontal Bladder Tanks

EPP4 Pressure Regulator Basic G 1/4"

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

Alphasense 4-20 ma transmitters offer convenience and easy maintenance for toxic sensors:

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

Z, Y, and X PURGE INDICATORS / CONTROLLERS

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

Plok. Rapid Mating Multi-Pin Industrial Connector. Amphenol Industrial Sine Systems * Pyle Connectors Corporation

Air Bubbler Depth Gauge DG2200 Installation and Reference Manual

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

Procedure Troubleshooting the Interconnect Cables

Model 10E Enviro-Line Environmental Pressurization System Installation & Operation Manual

Transcription:

What s Included (1) Buoy hull with data well, 950 lb buoyancy (1) Buoy tower (3) 40W Solar panels (1) Data well lid (isic-cb or pass-through) (3) Top-side lifting eyes (3) Bottom-side mooring eyes (1) Instrument cage, large Common Accessories isic-cb data logger enclosure RTU-R/C/I telemetry module CB-A05-2 battery harness/regulator assembly, (2) x 28 A-Hr batteries CB-A05-3 battery harness/regulator assembly, (3) x 28 A-Hr batteries M650H-Y LED beacon RA-4180-1 mini radar reflector 916M 6 sensor deployment pipes CB-PW-AC-60W battery charger Assembly Overview Figure 1: CB-950 Data Buoy Overview The NexSens CB-950 data buoy platform is constructed with a closed cell, cross-linked polyethylene foam hull with polyurea coating that provides 950 lb buoyancy. The buoy has a corrosion resistant, stainless steel internal frame with topside lifting eyes and subsurface mooring eyes for connection of single-point and multipoint mooring systems. An integrated data well located within the buoy hull accommodates batteries and electronics. The data well lid is available as a NexSens isic-cb data logger assembly or as a standard lid with pass-through fittings for use with user-supplied electronics. Internal batteries are recharged by (3) 30-Watt solar panels mounted on the buoy tower, which also supports an optional LED beacon, radar reflector, and RTU-R/C/I radio, cellular or Iridium satellite telemetry module. The main components of the CB-950 data buoy platform are assembled at the time of shipment. Installation of accessories may be required. Quick instructions are provided in this guide. Visit the online Knowledge Base for more information (see Additional Information section). Instrument Cage The instrument cage is connected to the buoy using a CB-CCA cage clamp accessory. Reference the instructions provided with the clamp for installation. Welding the cage and/or installing additional security straps is also recommended for use in rough water. Figure 2: Cage with CB-CCA Clamp 1

Solar Tower The top plate of the solar tower has hole patterns designed for mounting of an M650 beacon, RTU- R/C/I telemetry module, RA-4180-1 mini radar reflector, and/or a weather sensor mount. These devices are typically mounted on the tower in the factory prior to shipment. Make any changes or additions prior to installation of the tower onto the buoy. Figure 5: Locking Pin and Tower Mount Hub Figure 3: Tower with Beacon and Radar Reflector Deployment Pipe Figure 6: Installed Tower The bottom of the buoy hull includes (3) 6 female threaded couplings for connection of NexSens 916M deployment pipe assemblies or other PVC fittings. To use these ports, simply thread each deployment pipe securely into one of the available couplings. Figure 4: Tower with Beacon and RTU-C Module When the tower is ready to be mounted, remove the locking pin from each of the three tower mounting hubs on top of the buoy hull. Place the tower legs into the hubs and secure the locking pins. Instruments deployed in 916M pipes can easily be accessed for calibration and maintenance by removing the port cover plate from the top of the buoy hull. Use a 5/16 Allen/hex key to remove the set of screws on the cover plate. 2

Wiring & Device Connections NexSens isic-cb Data Well Lid each other if both are connected to P0. RS-485 and SDI-12 ports are shared throughout the bus. For systems using NexSens electronics for data acquisition and telemetry, the isic data logger is housed in an isic-cb enclosure that provides a watertight seal over the data well. The bottom of the isic-cb has a power plug that connects to a CB-A05-2/3 battery/solar regulator assembly. The top of the isic-cb enclosure has a series of UW ports for connection of solar panels, sensors, communication devices, and external power supplies to the isic. The available ports and functions are: - (5) SENSOR (P0/P1/P2): NexSens sensorbus architecture includes wiring for SDI-12, RS- 232 and RS-485 devices. For compatibility, sensors must have a factory-installed UW plug connector. The sensor ports are wired as follows: (2) P0: 12V full power, shared RS-232 port. (2) P1: 12V switch power, shared RS-232 port. (1) P2: 12V switch power, unique RS-232 port. - (1) COM: Communications port for isic data logger configuration and data acquisition through UW-USB-232P-NP cable or RTU-R/C/I radio, cellular, or Iridium satellite telemetry module. - (1) SOLAR: 6-pin input for solar panel to apply system power and charge internal battery. Solar cable or a specialized UW plug with jumper (P/N UW-JUMPER) must be connected to SOLAR port to power the isic. - (1) VENT: Gortex vent for relief of outgassing pressure during recharge of batteries located in the data well. In heavy wave conditions, this vent can be plumbed with tubing to the top of the tower. The sharing of RS-232 ports on P0 and P1 means that only one non-addressable device can be connected at a time. For example, two devices with RS-232 NMEA0183 output will interfere with Figure 7: isic-cb Enclosure Devices with analog outputs (e.g. 4-20 ma, 0-2.5 VDC) may be connected to the isic-cb through a mv-rs485 adapter, which converts the analog signal to RS-485 Modbus. The mv-rs485 adapter must be programmed for the specific sensor connected. See the instructions provided with the adapter for more information. Figure 8: mv-rs485 Adapter 3

Table 1 shows the sensorbus signal for each pin on the UW receptacle ports of the isic-cb. The pins are numbered based on the diagram in Figure 9 (plug pins are 1-4, socket pins are 5-8). The table also lists the corresponding wire color for a UW plug to flying lead cable connected to a port (see Figure 10). The system battery voltage can be checked externally by placing the leads of a voltmeter on pins 4 (red) and 7 (black) of a P0 or COM port. Table 1: UW Receptacle sensorbus Wiring UW Receptacle Pin Wire Color sensorbus Signal 1 Green RS-485 A 2 Blue RS-485 B 3 Brown SDI-12 4 Red 12V Power 5 White 5V Power 6 Yellow RS-232 Rx 7 Black GND 8 Orange RS-232 Tx Figure 10: UW Plug to Flying Lead Cable Pass-Through Data Well Lid For applications with user-supplied sensors, data loggers, telemetry modules and/or batteries, the CB-950 data buoy is provided with a data well lid with a set of plugs and pass-through fittings for securing user-supplied instrument cables. The lid includes the following ports: - (6) PASS-THROUGH: Blank UW receptacles supplied with a set of plugs for sealing unused ports and a set of fittings for securing instrument cables going into the data well. - (1) SOLAR: 6-pin port for connection of solar panel assembly. Includes connector inside data well for use with optional CB-A05-2/3 battery/solar regulator harness. For use with user-supplied battery/regulator systems, see Solar Power Wiring. - (1) VENT: Gortex vent for relief of outgassing pressure during recharge of batteries located in the data well. Tighten the fittings securely around cables routed into the data well to maintain the watertight seal. Plug all ports that are not used. Figure 9: UW Connector Pinout 4

For a more robust connection at the data well plate, the pass-through ports may be fitted with UW-BULK bulkhead receptacle connectors. The UW-BULK assembly has the same pinout as isic- CB sensor ports (see Table 1), but the cable terminates in flying leads for integration with a user-supplied data logger. The device connected must have a factory-installed UW connector. Figure 11: UW-Bulkhead Connector Assembly Solar Power Wiring Figure 12 shows a schematic drawing for the wiring of the CB-950 power supply. The system includes (3) 30-watt solar panels that connect through the SOLAR port on the data well plate to the CB-A05-2/3 or user-supplied battery/solar regulator harness. A wire lead is provided to supply 12V DC power to electronics inside the data well (red = +12V, black = GND). Figure 12: Wiring Schematic *NOTE: The 12V power supply leads for user supplied electronics will only supply power when the solar panel is plugged into the SOLAR port on the data well lid, even if a battery is connected inside the data well. To supply battery power without plugging in the solar panel, a special UW plug with internal jumper is available (P/N UW- JUMPER). For systems with user-supplied battery and solar regulator, the battery and regulator can be connected through the 4-pin Molex connector or by cutting the wires at section A-A in Figure 12 and splicing the connections. In these situations, reference the signals listed in Table 2. 5

Table 2: Wiring for user-supplied battery/regulator Signal Wire Color +12V Red GND Black Solar input Yellow Charge output Orange cage. Figure 13 shows an example of a buoy system with a short section of chain added. The buoy data well is not rated for submersion, so proper ballast weight is critical to ensure that the buoy does not overturn, including when the buoy is subjected to additional loading (e.g. high wind/waves, periodic snow/ice loads, etc.). Ballast Weight and Stability To prevent overturning of a CB-950 buoy system and to ensure that it is stable in the water, a minimum ballast weight of 125 lbs. is needed for calm deployment locations and more in rough waters. The center of gravity of the buoy is somewhere near the water surface without instruments connected. Any weight added above the water surface must be appropriately counterbalanced by adding ballast weight below the surface. The larger the distance from the location of added weight to the center of gravity, the greater the effect on the stability of the buoy will be. For example, if a weather sensor is mounted 36 above the water surface, it will cause more instability than if it were mounted 24 above the surface and, as a result, would require more subsurface ballast weight to counterbalance the buoy. Conversely, a ballast weight added further below the surface will provide a greater stabilizing effect than the same size weight mounted closer to the surface. An instrument cage mounted to the buoy frame helps to stabilize the buoy and provides a deeper location for mounting additional weight. For single-point mooring configurations, mooring chain and lines connected to the bottom of the cage may provide adequate ballast. For multipoint configurations, the mooring hardware does not contribute to the ballast weight. Before deployment of a CB-950 system, some experimentation may be required to properly balance the buoy. If needed, add ½ chain (~2.3lb/ft) or other weight to the bottom of the Figure 13: CB-950 Data Buoy with Ballast Chain Saltwater Deployment Sacrificial zinc anodes should be used whenever a buoy is deployed in a saltwater environment to prevent corrosion. These zinc anodes must be inspected and replaced as needed. 6

Mooring Configurations This section contains only general information on the available mooring options for CB-950 data buoys. To develop an effective mooring strategy, a variety of application-specific criteria (water level fluctuations, currents and wave action, debris loads, etc.) must be thoroughly reviewed prior to deployment. NexSens does not endorse any particular mooring strategy for any specific application. Single-Point Mooring Single-point moorings are used in calm waters when monitoring sensors are attached to the instrument cage or housed in deployment pipes. The sensors are thus protected and less vulnerable to damage caused by subsurface debris, high currents, and entanglement from anchor lines. In a single-point configuration, a stainless steel mooring line connects the buoy directly to a bottom chain and anchor. At normal pool/stage, the mooring line should be taut, with most of the bottom chain resting on the floor of the water body. As the water level increases and the buoy rises, the bottom chain is lifted from the floor. Two-Point Mooring Two-point moorings are commonly used when monitoring sensors are deployed in the water column below the buoy. In this setup, the mooring lines are pulled taut away from the buoy, freeing the water column for a suspended sensor line. In most two-point configurations, mooring lines connect the data buoy to small marine marker floats, often located on the water surface. These marker floats are shackled to another mooring line that runs to the floor and connects to a bottom chain and anchor assembly. Additional subsurface marker floats may also be used in some applications. As in single-point systems, the bottom chain prevents buoy submersion as the water level fluctuates. Figure 15: Typical Two-Point Mooring Configuration Figure 14: Typical Single-Point Mooring Configuration 7

Safe Deployment Personnel safety is the number one priority when deploying a data buoy. Use of proper equipment (work boat, lifting rig, gloves, safety footwear, etc.) is essential to safely deploy any buoy system. Buoy systems are heavy and personnel can quickly become entangled with mooring lines and anchors. Safety and flotation gear should be worn at all times when working on or near the water. Remember to perform a complete system test on shore prior to deployment. Learning the nuances of the system is much better handled on shore or in a lab rather than in the field. Specifications Hull Dimensions: 42 (106.70cm) outside diameter; 26 (66.04cm) tall Tower Dimensions: 45 (114.30cm) tall, 7/8 tubular Data Well Dimensions: 10.3 (26.16cm) inside diameter; 25.5 (64.77cm) tall Weight: 285 lbs. (129.27 kg) Buoyancy: 950 lbs. (430.91 kg) Hull Material: Cross-linked polyethylene foam with polyurea coating & stainless steel deck Tower/Hardware Material: 304 stainless steel Other Material: Galvanized ballast chain Mooring Attachments: 1- or 2-point, ¾ eye nut Solar Power: (3) 40-watt, 12VDC solar panels Additional Information Additional information and complete instructions for the CB-950 data buoy platforms are available in the NexSens online Knowledge Base: http://www.nexsens.com/knowledge-base http://www.nexsens.com/category/knowledgebase/data-buoys/cb-950-buoy 8