Automation. Efficient, Secure and Powerful Automation for Density & Refractive Index

Similar documents
GDRP Hints & Tips. How to Achieve the Best Results Day-to-Day Refractive Index Measurement. Hints & Tips. Good Refractometry Practice Brochure

Density2Go. Hydrometers Pycnometers Digital Hydrometers. 3 Ways to Measure Density Know-How, Hints, and More

Automated Liquid Handling Station

Appendix D: SOP of INNOVA 1412 Photoacoustic Multi-Gas Monitor. Description and Principle of Operation

Tensiometer For the measurement of surface and interfacial tension

Tensiometer For the measurement of surface and interfacial tension

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Ultrasonic baths. XUB range of digital ultrasonic baths. XUBA range of analogue ultrasonic baths. Digitally controlled range with a choice of 5 baths

Easy with a modular concept for future expansion

Benefits. Rev.III_032018_Oxybaby 6.0_engl subject to technical alterations

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

Quantos Automated Dosing Solution Preparation Precise concentrations Process compliance Minimize out-of-specs

Application Note. Rapid performance verification of AZURA systems with refractive index detector. Summary. Introduction

NanoSight NS300. NanoSight NS300. Operation instructions. Laser Spectroscopy Labs, UCI

FAST EVAPORATION AT NORMAL PRESSURE

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

Pool and Spa. Water Testing

Safety Data Sheet according to Regulation (EC) No 1907/2006

SPECIFICATIONS PARTICLE SENSOR KS-18F Higashimotomachi, Kokubunji, Tokyo , Japan

Columbus Instruments

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

Armfield Distillation Column Operation Guidelines

Technical Procedure for General Laboratory Equipment

Improve Process Reliability

Read this first. Zetasizer nano series Self installation and Quick start guide MRK825-02

SPECIFICATIONS PARTICLE SENSOR KS-19F Higashimotomachi, Kokubunji, Tokyo , Japan

Dräger X-act 5000 Automatic Dräger Tube Pump

Mass Flow Controller (MFC) for Gases

ALR Product Catalog. Reactors for the World of Chemistry. 500 ml Reactor Sets. Accessories Spares

VIAFLO 96. Electronic 96 Channel Hand Held Pipettor

MV5: Automated concentration system

Multiphase MixMeter. MixMeter specification. System Specification. Introduction

Versatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler

Calcium Reactor. CalcFeeder PRO. User Manual 1.1a. Model. CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO

OPERATION OF LIQUID PARTICLE COUNTER. GP-B P0045 Rev -

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2

Accurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display: Quick connect spindles:

Setting a New Standard in Flash Chromatography Performance

Mass Flow Controller (MFC) for Gases

User Manual. Quantos Automated Dosing Powder Module

HI 2314 HI 2315 HI 23151

AUTOMATIC HOSE TEST UNIT, TYPE SPU

GAS ANALYSER OXYBABY M+ for O 2. or O 2 /CO 2. standard version

Code Basic module and level control complete with optionals code

AUTOMATIC VAPOR PRESSURE TESTER REID METHOD, DEMI SIZE MODEL AVP-30 INSTRUCTION MANUAL. Rev

Environmental Petrochemical, Pharmaceutical, Foods & Flavors, Chemicals, Personal Care, Forensics,...and more!

Pneumatic high-pressure controller Model CPC7000

AKTA pure 25 New Owner s Intro

UsER manual for Watersens ph -REDOX

Certified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS

User Manual. Quantos Automated Dosing Liquid Module

SECTION 1: Identification of the substance/mixture and of the company/undertaking

BASIC Z-STACK AND TIME SERIES SCAN ON THE ZEISS LIGHTSHEET Z. 1

Material Safety Data Sheet Vybar Art

High Pressure Asher HPA-S

Specifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2

6900 Maintenance Instruction System Flush

GAS ANALYSER OXYBABY 6.0 for O 2. or O 2 /CO 2. premium version

Instructions for Assembly, Installation, and Operation of the Gas Addition Kit Accessory with the CEM Discover Systems

SAFETY DATA SHEET. according to Regulation (EU) No. 453/ Identification of the substance/mixture and of the company/undertaking. None.

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

Ultrasonic level transmitter and indicator

The instrument will process the samples one by one till all the samples have been cleaned up.

Mass Flow Meter (MFM) for Gases

Rotary Viscometers Rotary viscosimeters ST-2020

BS ml Bottle Sampling Unit

Tips for Proper Pipette handling and Maintenance. D. Muruganand, Ph.D ILQA - Bangalore, Feb 2014

Used with Dissolution Tester for Fraction and Flow Measurements

Qi Litre Ultrasonic Cleaner

NEW: CO2 incubator with sterilizable sensor

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

1 Designation of the substance or mixture, respectively, and of the company

Best Practice for Calibrating LTH Conductivity Instruments

Instruction Manual Dräger MSI P7 and MSI P7 plus

These variables can be accessed by holding the UP button for 5 seconds.

BIOSTAT CultiBag RM Culturing Convenience

IMPROVING QUALITY THROUGH INNOVATION: A FULLY AUTOMATED SOLUBLE SALT METER

The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator

Equipment and Accessories. ROMIL LiQuiSure. Designed for High Purity Containment & Dispensing PURE CHEMISTRY

RH800 & 2000 BASIC OPERATIONS

FROG-4000 TM Chemical Analysis System

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

sorting solutions osx separator series

SAFETY DATA SHEET GREEN HMP

Operating Instructions METTLER TOLEDO Pipette Check Application for AX and MX/UMX Balances Version 1.xx

6800 Maintenance Instruction System Flush Procedure

CHM250 Calibration and Measurement Lab. Balance Calibration

Elcometer 138. Bresle Kit and Patches. Operating Instructions

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

OXYBABY - MOBILE HAND HELD GAS ANALYSER

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

User s Booklet for the Wyatt minidawn Light Scattering Instrumentation

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

Pneumatic high-pressure controller Model CPC7000

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

RADWAG Mass Comparators - ETERMA 2013 MASS COMPARATORS

Transcription:

Automation LiquiPhysics Automation Solutions SC1 / SC30 SC1H / SC30H InMotion FillPal Efficient, Secure and Powerful Automation for Density & Refractive Index

Overview Automation Of the whole Workflow Automation from a hardware point of view is more than just a pump which fills the measuring cell of the density meter or refractometer. The benefits of an automated system are more than just saving time and costs. LiquiPhysics Excellence allows the entire workflow to be automated for more reliable results, increased safety and no errors. Crude Oil or Beverages? Find the right Automation Solution to suit your Needs FillPal / DryPal Working principle: peristaltic pump (FillPal) and drying pump (DryPal) for single samples Use: sampling directly out of the bottle/container, for low viscosity samples. Either just oversampling or rinsing and drying of the cell after measurements (e.g. oily samples). Can also be used for by-pass at-line measurmet. High resistant tube version available (FillPal Chem ) Typical applications: Beverage analysis (FillPal Food) or chemicals e.g. solvents, acids etc. (FillPal Chem) Pre-measurement Sampling / measuring / cleaning LabX PC software: importing measurement task directly from LIMS/ERP System to the instrument and scheduling of tasks (e.g. daily calibration at 6 pm.) Biometric instrument login with LogStraight fingerprint reader SmartCodes : use barcodes for more than just the sample ID. Specify also the Method ID so that the correct method for each sample is automatically selected Prepare your samples (e.g. direct degasing of carbonated beverages) or keep them at the correct temperature Required operator time is reduced to a minimum: just place the vial/ beaker and get the results with a single click or barcode scan Increased throughput, particulary when several parameters are combined in one automated system (e.g. density, refractive index, ph and color) No more error-prone manual operations such as filling a density meter with a syringe. Even untrained operators always get the correct results! Highest possible protection of operators from vapors/toxic samples Automatic multiple determination increases result reliability Even the most difficult samples can be handled Automatic verification if measuring cell is perfectly clean InMotion Autosampler Working principle: Sample changer with peristaltic pump. Sample rack for up to 303 samples Use: Efficient sampling of low-viscous similar kindred samples that do not require intermediate cleaning of the measuring cell. High resistant peristaltic tube available Typical applications: Beverage analysis (Brix, ph), including automatic degassing of carbonated drinks. Chemicals such as solvents, antifreeze etc. SC1 / SC30 Automation Units Working principle: overpressure filling and fully automatic rinsing and drying of measuring cell(s). For single samples (SC1) or with sample magazine for 30 samples (SC30) Use: suitable for any kind of sample, be it highly viscous, highly volatile or difficult to clean Typical applications: Flavor and Fragrance industry (perfumes, essential oils), food (syrups, juice concentrates), Petro industry (light crude oils, refinded products, lubricants), cosmetics (creams etc.), chemical industry (solvents, acids, bases, etc.) Post-measurement Immediate QC results: product database with stored result limits and automatic result evaluation (pass / fail) Any kind of report is possible (strip printer, network printer, PDF, Excel) Easy data export to LIMS system LabX PC software: full 21 CFR 11 compliance (secure storage of data in SQL database, audit trail and electronic signatures), biderection intergration to ELN, LIMS or SAP SC1H / SC30H heated Automation Units Working principle: overpressure filling and fully automatic rinsing and drying of single samples (SC1H) or with sample magazine for 30 samples (SC30H) Use: suitable for density measurement of extremely viscous samples and samples which are solid are room temperature Typical applications: Petro industry (heavy crude oils, bitumen, waxes, paraffin ) cosmetics (lipsticks), food (honey) 2 3

SC1 and SC30 Powerful Automation For any kind of Sample Whether for single sample automation (SC1) or as a sample changer (SC30) the powerful sampling by overpressure allows highly viscous products to be sampled and avoids evaporation of volatile sample compounds. Several instruments (density meter, refractometer, ph / conductivity meter, photospectrometer, titrator, polarimeter etc.) can be combined to a multiparameter measuring system automated with SC1 or SC30. Sampling, contamination free sample recovery if needed, rinsing and drying of all cells and tubes is done fully automatically. Learn more about the simultaneous measurement of density, refractive index, ph and color. www.mt.com/liquiphysics-multiparameter Easy & error free Powerful cleaning Increased throughput The parameters are determined by simply placing the vial and starting the measurement with OneClick on the touch screen display of the density meter or refractometer. A built-in or handheld barcode reader identifies each sample and automatically starts the corresponding analysis. The highly effective turbulent cleaning, where the rinsing liquids are mixed with a high proportion of air, ensures fast rinsing cycles and helps to save rinsing solvents. As little as 8 ml of acetone or ethanol can then be sufficient as a second rinsing liquid. Save up to 70% labor time and increase throughput by 50% with automated multiparameter systems. All parameters (density, RI, color etc.) are determined simultaneously in all instruments and cleaning is done only once for the whole system with the SC1/SC30. See a video of the SC1 and SC30 in use: 4 5

SC1H and SC30H Heated Power For highest Viscosities Concerned about measuring density of heavy crude oils, bitumen, lubricating greases or waxes? Or the density of lipstick? The powerful SC1H (single sample) and SC30H (sample changer) heated automation units can completely automate the density measurement of highly viscous products or even samples that are solid at room temperature. The automated measuring system also protects operators from direct contact with toxic solvents or vapors and from handling hot syringes. High occupational safety at low operational costs. Learn more about the analytical instruments from METTLER TOLEDO for the petro industry. www.mt.com/analytical-petro Reliable results Health Protection Contact free operation Bubbles are impossible to see in pitch-black petro samples. An automatic two-fold measurement excludes the presence of bubbles and ensures the results obtained are consistently reliable. LiquiPhysics density meters convert measured values to required reference temperature and output values (e.g. API at 15 C). When measuring petroleum products, hexane and toluene are good for cleaning, but exposure can be harmful. SC automation units protect operators from direct contact with toxic solvents or vapors. The toxic and smelly waste is collected in a separate container, which can be equipped with the LevelSens to eliminate the risk of overfilling. No mouse to connect, no button to click: Gloves protect your skin as the ErgoSens protects your instrument. There is no need to remove protective gloves as the measurement can be started without touching anything. Moving a hand over the ErgoSens, an infrared sensor for hands-free operation, is all that s needed. Check the video to see how an SC1H is used for measuring highly viscous bitumen samples 6 7

InMotion Flex, Pro and Max Maximum Productivity In Beverage Analysis The InMotion TM Autosampler series is the perfect efficient solution for the beverage industry or for other low-viscous samples where oversampling is sufficient, i.e. no intermediate cleaning of the measuring cell is required. Different beaker sizes and up to 303 sample positions offer easy handling and high throughput. Optional stirrer and ph measurement for fruit juices and automatic degassing of carbonated beverages ensure efficient workflows. Learn more about the analysis of beverages with the InMotion autosamplers. www.mt.com/inmotion-beverage Brix and ph in beverages Easy to use Modular and tailored to your samples With the overhead Compact Stirrer, juices are properly homogenized and reliable ph results are ensured. It can be used in combination with the DryPal air pump to efficiently degas carbonated beverages prior to analysis of Brix, ph and even acidity in the same system. With the PowerShower it s a matter of a single click on the touchscreen to thoroughly flush the ph electrode, stirrer and sampling tube. Rinsing of the refractometer / density meter and a Test (calibration, check) with water can be done with a single click. Every lab and sample has its own demands. Build your autosampler according to your sample needs. Use the CoverUp lid handling system to protect your samples and operators (e.g. measurement of solvents) as well as a barcode reader for automatic ID and/or analysis method recognition. Check the video to see an efficient beverge analysis 8 9

Technical Specifications Specifications FillPal InMotion SC1 Food Chem Flex Pro Max 51326000 51337027 51337028 30094291* 30094292* 30094293* max. viscosity [mpa s] 1'000 1'000 30'000 (at pumping temperature) Chemical resistance SC30 51327000 organic solvents Acetone, ethanol ok Acetone, ethanol ok SC1H 51326400 acids no ok (most) ok with optional resistant tubing ok (samples like HBr or HCl only with optional Hastelloy needle) bases ok ok ok with optional resistant tubing ok Sampling suction (peristaltic pump) Overpressure (pump is in contact with dry air only) Automatic rinsing no yes with optional PowerShower yes, with 2 rinsing liquids after every measurement (additional rinsing liquids can be incorporated with the TV6 valve) Drying DryPal required DryPal required automatic Time for filling, measuing 1 to 5 min. (depending on instrument and method settings) Time for filling, measuring, rinsing, drying 3 to 10 min (depending on No. of parameters, sample viscosity, method settings) Sample recovery no yes yes, 100% contamination free Sample vials any type 25 ml (glass), 80 (PP), 100 ml (glass or PP) 6, 9 and 20 ml (glass, 20 ml also PP) 20 ml (glass or PP) N of samples / racks 1 (or at-line use with defined interval) 50 x 25 ml (30094124) 27 x 80 ml (30094125) 18 x 100 ml (30094126) 182 x 25 ml (30094129) 69 x 80 ml (30094130) 34 x 100 ml (30094131) 303 x 25 ml (30094134) 113 x 80 ml (30094135) 55 x 100 ml (30094136) SC30H 51327500 1 30 (6 and 9 ml used with adapter) 1 30 Minimal sample volume approx. 20 ml approx. 3 ml (for density and RI and ph at least 6 ml) 6-10 ml Temperature ambient ambient optional water bath rack for 100 ml beakers optional water bath rack for 80 & 100 ml beakers ambient ambient ambient 90 C (samples with a melting point of up to 60 C can be handled, e.g. paraffin, edible fats, cosmetics etc.). DM, RM (plus DX or RX), ph / conductivity, Instruments / Parameters DM, RM, ph / conductivity DM, RM, ph / conductivity DM color, others (controlled via RS-232) Dimensions W*D*H [mm] 255 x 160 x 85 420 x 534 x 563 420 x 568 x 56 239 x 310 x 342 582 x 392 x 402 400 x 355 x 450 610 x 455 x 500 Weight [kg] 2 12.1 13.7 14.5 9.5 17 19.7 34 *together with the InMotion Flex, Pro or Max base, a rack kit has to be ordered. See order numbers in section 'No. of samples / racks' Options and Accessories InMotion DryPal Drying Pump (51337029) High resistant ChemSure tube for SPR200 sampling pump (30094297) Overhead compact stirrer (51109150) Barcode Reader (30094235) CoverUp Flex for 80mL and 100mL (30094252), 10 pcs lids 80mL (30094274), 100mL (30094275) CoverUp Pro incl. lids for 80mL (30094253), 100mL (30094254) PowerShower pump SD660 (30094165) Rinse tube PowerShower Flex (30094167), Pro/Max (30094226) SC1 / SC30 ScanStraight built-in barcode reader - not for H versions (51337185) PPU Power Purge Unit, for faster cleaning and drying - in H version included (51327365) External drain valve, for samples with solid particles (51327346) Sampling needle made of Hastelloy C22 (51327420) Common Options LevelSens, sensor to prevent waste container overfilling (51109853) ErgoSens, optical infrared sensor for hands-free operation (11132601) 10 11

Learn more about our LiquiPhysics density meters and refractometers, find application notes, videos and educational material at: www.density.com www.refractometry.com www.mt.com For more information Mettler-Toledo AG, Analytical CH-8603 Schwerzenbach, Switzerland Tel. +41 44 806 77 11 Fax +41 44 806 73 50 Subject to technical changes 07/2014 Mettler-Toledo AG, 30213087 MarCom Analytical Quality certificate. Development, production, and inspection as per ISO9001. Environmental Management System as per ISO14001. «European Conformity». This mark indicates that our products meet EU guidelines.