Fully Fuzzy Auto Digital Wrist Blood Pressure Monitor. tensio control. INSTRUCTION MANUAL Model GP-6220

Similar documents
Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

Auto Arm Blood Pressure Monitor

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

REF CH-602B IDENTIFICATION OF PARTS

Sports Wrist Digital Blood Pressure Monitor Item #

Talking Wrist TypeBlood Pressure Monitor. Talking Wrist Type Blood Pressure Monitor Model: BPW810. User Manual

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

REF CH-302B IDENTIFICATION OF PARTS

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Contents. Safety Notice. Wrist Type

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Talking Wrist Style Blood Pressure Monitor Model INS-LAB-RevB08

Oregon Scientific Wrist Blood Pressure Monitor (BPW211)

English Español Português Italiano Deutch Français INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH-656C. - Eng 1 -

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

Semi-Automatic Blood Pressure Monitor with Memory

Digital Blood Pressure Monitor. Model UA-705. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni 1WMPD B

Digital Blood Pressure Monitor. Model UA-787

MODEL CH-432B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. - Eng 1 - English Español Português Deutch. Italiano Français CH-432B

6833_INSTRUCTIONS MANUAL DIGITAL WIRST BLOOD PRESSURE

Oregon Scientific Wrist Blood Pressure Monitor (BPW120)

Fully Automatic Blood Pressure Monitor

Owner s Manual. EZ Health TM Platinum Talking Automatic Wrist Blood Pressure Monitor ABP-A3

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Instruction Manual. Auto Inflate Blood Pressure Monitor

GoWISE USA R Blood Pressure Monitor Wrist Type. Instruction Manual

MEDICARE 60. Semi-automatic upper arm blood pressure monitor. Instruction manual

Operating Instructions Instrucciones de funcionamiento

VER: A00. Model No:BA2010

TD-3140 Blood Pressure Monitor. Owner s Manual

Instruction Manual. Automatic Blood Pressure Monitor for Arm - Voice Prompt Function Announces Measured Values HB-ZA310V

Wrist Type Blood Pressure Monitor

MODEL CH-485E INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. English Español Português Deutsch. English Español Português Deutch Français

SBC 21. Electromagnetic Compatibility Information

TD-3140 Blood Pressure Monitor. Owner s Manual

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

Blood Pressure Monitor

Blood Pressure Monitor

premium wrist blood pressure monitor

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Owner s Manual & Safety Instructions

VIDEO TUTORIAL: greatergoods.com/0605

5 series Blood Pressure Monitor

Instructions. Upper Arm Blood Pressure. Model EW3153

User Manual DMD1001. Arm Type. Digital Blood Pressure Monitor. version:1.0

User Manual DMD1001. Arm Type. Digital Blood Pressure Monitor. version:1.0

Content

Model M3 Intellisense

Check following components!

Blood Pressure Monitor

Module No GETTING ACQUAINTED GENERAL GUIDE TIMEKEEPING

Instruction Manual. Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS ) Model HEM-650 ESPAÑOL ENGLISH

Blood Pressure Monitor

Instructions for use. 3year. Wrist MOBIL BASIS. The monitor for first users To be used on the wrist. Also suitable for: WARRANTY. Clinically validated

Blood Pressure Monitor

Device Equivalence Evaluation Form

Model UA-705. Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Contents. Helpline No. UK/Northern Ireland , Rep. Ireland Web Support Model Number:

Instruction Manual. Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

Blood Pressure Monitor

Model MIT Elite Plus

Wrist Blood Pressure Monitor Model R2

INSTRUCTION MANUAL DIGITAL BLOOD PRESSURE MONITOR

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Instruction Manual Mode d emploi Gebrauchsanweisung Manuale di istruzioni Manual de instrucciones Gebruiksaanwijzing

Device Equivalence Evaluation Form Comparison of the Omron RS2 (HEM 6121 E) with the Omron RS3 (HEM 6130 E)

REF CH-308B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR IDENTICATION OF PARTS Eng 1 - Exhaust button Air connector Pumping bulb tube

Blood Pressure Monitor Instruction Manual

Fully Automatic ihealth Track Connected Arm Blood Pressure Monitor USER MANUAL

INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR

Blood Pressure Monitor

VGP-4300-G. Travel Pulse. Blood Pressure Monitor for Travel

PHY100 s Lab: The Relationship Between Liquid Pressure and Depth as it applies to Blood Pressure. Course & Sec:

User Manual DMD1001 1

Owner's Manual. Wrist-type Fully Automatic Blood Pressure Monitor. Contents. Safety Notice. Model BP2116. Document No. Version: REV

Digital Blood Pressure Monitor Model UA-621 Instruction Manual

Blood Pressure Monitor Instruction Manual

705CP-II. Automatic Blood Pressure Monitor & Printer. Mode d emploi page 67 Istruzioni per l uso pagina 89

3.1.3 Weight. Frequency. Weight is obtained at the baseline examination and annually. Equipment

Declaration of Equivalence Form

User Manual. Wrist Blood Pressure Monitor. Wrist Type

Declaration of Equivalence Form

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form

INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR

Instruction Manual. S&S Tradings

Model UA Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Digital Ear Thermometer

ProSeries 2. Blood Pressure Monitor. Quick Start Guide. A complete user guide is available at vitasigns.com

LD6. Digital Blood Pressure Monitor Instruction Manual

Declaration of Equivalence Form

User Manual. Blood Pressure Monitor. Arm Type

BM 26 ENGLISH. Blood pressure monitor Instructions for use... 2

ACCUSTRIDE ACCUSTRIDEFM. Digital Clip-on Pedometer WC153. Digital Clip-on Pedometer WC154 ENGLISH

Digital Wrist. Blood Pressure Monitor Advanced Wrist Monitor Instruction Manual

SECTION B of Declaration of Blood Pressure Measuring Device Equivalence

Declaration of Equivalence Form

Transcription:

Fully Fuzzy Auto Digital Wrist Blood Pressure Monitor tensio control INSTRUCTION MANUAL Model GP-6220 Manufactured by: Geratherm Medical AG Fahrenheitstraße 1 98716 Geschwenda Germany Phone: +49 (0) 36205 98-0 Fax: +49 (0) 36205 98-116 E-Mail: info@geratherm.com www.geratherm.com

CAUTION 1. Consult your physician to verify your blood pressure range before using this device at home. 2. If the cuff causes any discomfort during measurement, press the power key to turn off the device immediately. 3. Pull off the velcro strap to detach the cuff if the pressure is over 300 mm Hg and the cuff does not deflate automatically. Blood pressure measurements obtained with this unit are equivalent to those obtained by a trained person using the cuff/stethoscope auscultation method. This blood pressure monitor complies with the regulations set out in EU Council Guideline 93/42/EEC of 14th June 1993 concerning Medical Products and with the DIN EN 1060-1 standard (Non-invasive blood pressure monitors/part 1, general requirements) and DIN EN 1060-3 (Non-invasive blood pressure monitors/part 3, supplementary requirements for electro-mechanical blood pressure monitors). A quality management system in compliance with EN ISO 13485 ensures that the required quality criteria are met. WARRANTY: Three years from the date of purchase. 1 -

INFORMATION YOU SHOULD KNOW BEFORE OPERATING THE DEVICE What is blood pressure? A force is created by the heart as the ventricle forcibly ejects blood into the blood vessels and through the vascular system. Another force is created by the arteries as they resist the blood flow. Blood pressure is the result of these two forces. What are systolic and diastolic pressures? Systolic pressure represents the highest pressure at the height of the heart s contraction. Diastolic pressure is the lowest pressure when the heart is resting. Is my blood pressure normal? See the following blood pressure classification chart released by the WHO (World Health Organization) for evaluation of your blood pressure level. What about low blood pressure? Generally speaking, a lower blood pressure reading is better unless it causes some uncomfortable symptoms such as fainting and/or lightheadedness. Fluctuation and variation in blood pressure 2 -

Fluctuation and variation in blood pressure The following chart shows possible blood pressure fluctuations during a 24-hour period. Hypertension Boundary Lower Normal The following factors will influence blood pressure measurement results and cause variations: Bathing, Breathing, Conversation, Meals, Smoking, Exercise, Drinking Alcohol, Moving, Thoughts, Mental tension, Temperature change, etc. 3 -

ABOUT THE DEVICE Memory Botton LCD display Battery Cover Power Button The cuff is designed to fit wrist sizes between 13.6 and 19.5 cm (5.35 to 7.68 inch). 4 -

ACHTUNG EXPLANATION OF DISPLAYS Date Memory Low Battery Indicator Pulse Indicator IPD (Irregular Pulse Detection) ACHTUNG PREPARATION FOR USE Systolic Diastolic Pulse Rate Installing/Replacing Batteries 1. Press lightly on the arrow and slide the battery cover in the direction of the arrow. 2. Insert the batteries into the battery compartment matching correct polarities + and -. Note: Replace both batteries if the low battery indicator appears. Remove the batteries if the device will not be used for a long period of time. It is recommended that the same type of alkaline batteries be used to avoid incompatibility. 5 -

Attaching the Pressure Cuff 1. Free the left wrist of any clothing etc. and wrap the cuff directly around it. The display should be positioned on the palm side of the wrist. 2. Fasten the cuff. Make sure it is not too tight. The cuff s upper edge should be approximately 1 cm (0.39 inch) from the palm line. 3. If it is not possible to measure on the left wrist, attach the cuff on the right wrist as shown in the figure. Measuring Posture 1. Sit upright and place your forearm onthe storage case so that the device is at heart level. Relax and measure in a natural position. 2. Measure and record blood pressure at the same time every day to establish your blood pressure pattern. 6 -

ACHTUNG HOW TO OPERATE THE DEVICE 1. Setting the Clock Enter the clock setting mode by pressing and holding the MEMORY button for over three seconds. The display will show a flashing year. Press the POWER button to adjust the year when it is flashing. Then click the MEMORY button again, a month will appear and flash to be adjusted, and then date, hour, and minute will follow as you press and release the MEMORY button. To Adjust the Clock Press the POWER button to adjust the month, date, hour and minute when they are flashing. 2. Measuring Blood Pressure Press and release the POWER button to start measuring automatically. When the measurement is finished, the Initial display Pumping Measuring and buzzer sounds display will show the measured blood pressure and pulse rate. Press the POWER button to turn off the device. Otherwise the device will automatically turn off after 150 seconds. Note: If the symbol appears, it means the unit has detected irregular pulse during measurement. If the symbol appears regularly please consult a qualified physician for professional advice. 7 -

3. Recalling Stored Values 3.1 Press and release the MEMORY key to recall the last reading. (Example: no. 35 in the memory). The display will show the stored pressure and pulse rate in alternation. 3.2 Press the MEMORY button to go to previous stored values. 4. Erasing Stored Values You may erase one or all records in the memory. To delete one record: Step 1: Press and release MEMORY button to display stored values. Press and release MEMORY button again to choose the record that you wish to delete. Step 2: Press and hold the POWER button until the display shows del. Step 3: Press and hold the POWER button. After three beeps are heard, the selected record is deleted. To delete all stored values: Follow steps 1 and 2 above. Step 3: Press the MEMORY button again and the display shows del ALL. Step 4: Press and hold the POWER button. After three beeps are heard, all records are deleted. 8 -

BETRIEB ACHTUNG CARE AND DES MAINTENANCE GERÄTES Do not drop the device. Do not modify or disassemble the body or the wrist cuff. Do not twist the wrist cuff. Avoid thinner, benzene, and other harsh cleaners. Use a cloth moistened with water or neutral detergent to clean the body of the device and thenwipe it dry. Keep the device in a suitable place. Avoid high temperatures direct sunlight, high humidity, and dust. 9 - Remove the batteries if the device will not be used for a long time. Do not press the PO- WER button if the cuff has not been properly wrapped around the wrist.

BETRIEB ACHTUNG ERROR MESSAGES DES GERÄTES Message Correction The pressure measured was lower than 20 mm Hg. Please measure again. The pressure measured was higher than 300 mm Hg. Please measure again. Pumping error. Please check cuff and try again. The pressure can not be measured due to signal noise. Please measure again. The pumping pressure is higher than 300 mm Hg. Please measure again. or No display Low battery. Please check and, if necessary, replace the 2 batteries. 10 -

ACHTUNG SPECIFICATIONS Display System Measuring Method Liquid Crystal Display Oscillometric Power Source 2 alkaline AAA type batteries (1.5 V) Measuring Range Accuracy Inflation Pressure Exhaust Memory Display Low Battery Indicator Auto Power-Off Battery Life 20-300 mm Hg; 40-200 beats/minute ± 3 mm Hg ± 5% pulse rate Automatic with integrated electrical pump Solenoid valve 85 sets LCD (year/date/time, pressure and pulse) Yes After 150 s w/o any operation Around 250 operations Operating Environment +10 - +40 C; RH < 85% Storage Environment -20 - +50 C; RH < 85% Dimensions 76 x 76 x 38 mm (W x D x H) Weight Around 133g (includingbatteries) 11 -

Specifications are subject to change for improvement without notice. Calibration is recommended every two years. 12 -