User's manual A CHEMICAL OXYGEN SELF-CONTAINED SELF-RESCUER FOR ESCAPE

Similar documents
USER'S. manual. Ci-30KS S-30 MP1 A CHEMICAL OXYGEN SELF-CONTAINED SELF-RESCUER FOR ESCAPE

MSA AUER SSR 90 [K60]

Operating Manual MSA SSR 30/100 / MSA SSR 30/100 B EN K/20/S. Order No /01. MSAsafety.com

MSA AUER SSR 30/100 MSA AUER SSR 30/100 B

APPLICATION & LIMITATIONS:

Operation manual. K-S30 Chemical Oxygen Self-rescuer. Version No.: rev.01. Issue date:

Fire Escape Hood OPERATION AND INSTRUCTIONS

STAGE I: FORMATION ( )

OCENCO M-20.3 Capacity 1 - Closed Circuit Escape Respirator (CCER) Emergency Escape Breathing Device (EEBD)

Entry to these spaces must be rigorously controlled to prevent serious injury or death.

Respiratory Protection. Program

Respiratory Protection

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

Ocenco Incorporated. M-20 Self Contained Self Rescuer Instruction Manual

Model XSMKIT. Operations and Instructions WARNING

CleanAIR ARES CA-83. welding leather hood. Contents. 1 General information 2 Use 3 Technical specification 4 Maintenance 5 List of parts 6 Approvals

COLUMBUS STATE COMMUNITY COLLEGE EMPLOYEE SAFETY MANUAL

INSTRUCTION MANUAL FOR EBA MINUTE SELF-CONTAINED SELF RESCUER (SCSR) Manual Number: NH13747 Revision: A, ECN 2384 September 7, 2001

Self-Rescue Equipment and Skill Development for Mine Escape

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Organic Vapor/P95, Disposable

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

BREATHE SAFELY: The Proper Use of Respiratory Protection

TABLE OF CONTENTS PART 2 - CONFINED SPACES

Filter cartridge protection class A2 Organic vapours, with boiling point above 65 C, to 50X OEL or 1000 ppm, whichever is the lower.

6A.004 SCBA MAINTENANCE. Policy Number. Page 1 of 5 SCOPE

Material Safety Data Sheet

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

RESPIRATORY PROTECTIVE EQUIPMENT ADVICE FOR WORKERS

INSTRUCTION MANUAL EBA-75 CLOSED-CIRCUIT ESCAPE RESPIRATOR (CCER) CAPACITY 3

Yoke Block Instruction Manual

Respiratory Protection for Producers

University of Alabama Office of Environmental Health and Safety. Respirator Protection Training

"RESPIRATORY PROTECTION AND SAFETY"

60 Minutes Self Contained Self Rescuer. Donning Procedures for Person-Wearable Self Contained Self Rescuer

SIGMACAP ZINC SILICATE PIGMENT Version 1 Print Date Dec 2002

Phalanx Alpha Phalanx Beta and Ultra Elite

PRODUCT HEALTH AND SAFETY DATA

Safety Data Sheet. according to Regulation (EC) No 1907/2006. Freezer BR

PremAire INSTRUCTIONS FOR VORTEX TUBE MODE OF OPERATION

A. Evaluation of the written program

Personal Protective Equipment 29 CFR 1926

RESPIRATORY PROTECTION PROGRAM OSHA Respiratory Protection

Australian/New Zealand Standard

BRAKE WINCH RUP 503-[T/BT] EQUIPMENT FOR LIFTING LOADS. AT 053-[T/BT] xx

BGC HOLDINGS LTD RESPIRATORY PROTECTIVE EQUIPMENT (RPE) POLICY

3/8" Dr. Air Butterfly Impact Wrench

MATERIAL SAFETY DATA SHEET. : Palm Kernel Expeller

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Respiratory Protection Program

Yoke Block Instruction Manual

SAFETY DATA SHEET SOLUFEED TEMAG + HPE

Siphon vessel / Priming aid

J800 HOPE BUOYANCY COMPENSATOR OWNER S MANUAL

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Owner's Manual SMA2000 Series

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY Respiratory Protection Policy 03/20/15 Last Revision

Operating manual for descender and rescue lifting devicesafescape

Safety Data Sheet according to Regulation (EC) No. 1907/2006 (REACH) with its amendment Regulation (EU) 2015/830

MINIATURA PAINT SPRAY HELMETS

Cal/OSHA T8 CCR 1536 Cal/OSHA T8 CCR 4799 Cal/OSHA T8 CCR 4845 Cal/OSHA T8 CCR 4848

Respiratory Protection Program 29CFR

VFlex 9105/9105S Particulate Respirator N95

Drawn up by: / RK Revision: 01 Reviewed: Page: 1 of 23 HI-SR 540 USA. Operating instruction SR 540 Face Shield

Dräger PARAT Escape Hoods

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Respiratory Protection Self-Inspection Checklist

SAFETY AND HEALTH IN THE USE OF CHEMICALS AT WORK

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

Compact Ball Valves ASAHI AV VALVES. Contents. User s Manual. (Page) (1) Be sure to read the following warranty clauses of our product 1

Respiratory Protection Self Inspection Checklist

Ontario Operations PMP - Daily Safety Message. Respirator Safety

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Particulate Respirator N95

LPG SAFETY INFORMATION. Kwik-Gas. Safety Manual. Less talk more energy

Respirator Fit Testing DEPARTMENT OF LABOR Information on the Requirements Types of Respirators & Filters

Safety Data Sheet. 1. Identification of the Substance/Preparation and the Company Undertaking. Polypipe Terrain Soluble Lubricant

In addition to the responsibility for managing the elements of the respiratory protection program, he/she will be responsible for:

Company: Concrete Patterning Supplies Limited

Boytorun Kimya Sanayi A.Ş.

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

MATERIAL SAFETY DATA SHEET

M5400 Operators Manual

Safety Data Sheet according to Regulation (EC) No. 1907/2006 (REACH) with its amendment Regulation (EU) 2015/830

RESCUE LIFTING DEVICE RUP 503-[...] AT 053-[...] xx

Astro Sandblast Helmet

HEALTH & SAFETY DATA SHEET AS-90 WELDERS MULTI-USE FLUID IDENTIFICATION OF THE SUBSTANCE/PREPARATION SPECIFICATION & INTENDED USE:

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

r (bar) Air Volume(L) Approval Service Life TPED 15

Health and Safety Data Sheet

Protective device that covers the nose and mouth or the entire face or head to guard the wearer against hazardous atmospheres

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

30T A/Manual Hydraulic Shop Press

SAFETY DATA SHEET Resiblock Indian Sandstone Sealer Invisible

Safety and operating instructions

Needle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2

MATERIAL SAFETY DATA SHEET WATER GUARD, INC.

SAFETY DATA SHEET INDUSTRIAL EP COMPOUND HEAVY DUTY GEAR LUBRICANTS Revision Date:

TOWN OF LINCOLN ARENA FACILITIES OPERATIONAL SAFETY POLICY

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Compressed Gas Safety Standard

Transcription:

User's manual A CHEMICAL OXYGEN SELF-CONTAINED SELF-RESCUER FOR ESCAPE

ROXY 30 (SANS 1737:2008) CONTENTS DEZEGA DESIGNATION... 3 SAFETY PRECAUTIONS... 4 TECHNICAL DATA... 5 PRIOR TO USE... 6 DESIGN... 7 CARRYING METHOD... 8 RECOMMENDATIONS FOR USING, RECORDKEEPING AND HANDLING... 8 OPERATING PRINCIPLE... 9 DONNING PROCEDURE... 10 IMPORTANT ESCAPE RULES... 13 TRAINING... 14 SERVICE AND MAINTENANCE INSPECTION... 15 DISPOSAL... 16 MARKING AND SEALING... 18 RULES FOR STORAGE AND TRANSPORTATION... 19 WARRANTY... 21 ANNEX А... 22 ANNEX В... 23 2

DEZEGA ROXY 30 (SANS 1737:2008) Any use of the chemical oxygen self-contained self-rescuer requires full understanding and strict observation of this «User s manual». Only in this case using ROXY 30 guarantees safety and protection of the respiratory system. The chemical oxygen self-contained self-rescuer is only to be used for the purposes specified here. Original equipment manufacturer supplies «User s manual» in English or Russian. For providing of «User`s manual» in the official language of the country of destination, contact our local office, distributor or authorized representative. DESIGNATION «User s manual» is intended for study of device and requirements for everyday carrying, donning and operation of chemical oxygen self-contained self-rescuer. Self-contained self-rescuer (hereinafter SCSR) ROXY 30 is a belt worn breathing apparatus to exit from the danger zone in the event exposure to an irrespirable atmosphere. ROXY 30 satisfies all requirements of SANS 1737:2008. Name of ROXY 30 consists of: «ROXY» means name of self-contained self-rescuer; «30» means rated duration when testing in accordance with SANS 1737:2008 at breathing rate 35 l/min. ROXY 30 is designed and suitable for everyday carrying on the waist belt and for storage in rescue chambers or changeover stations that are placed on routes out of danger zone in mines, as well as in tunnels. ROXY 30 is used for protection of respiratory system and eyes in case of underground workers escape from irrespirable environments due to fire, explosion, and sudden release of gas or coal dust or lacking of oxygen. ROXY 30 may be used in other applications by agreement with manufacturer, where there is a risk of unsuitable for breathing environment. It is prohibited to use ROXY 30 during any physical performance, for example for underground firefighting. 3

ROXY 30 (SANS 1737:2008) DEZEGA SCSR is ready for use device in mines of different hazard categories: prone to sudden outbursts of coal and gases, mines with aggressive production environment with acid mine drainage and water with high concentration of corrosion-active components: chloride and sulfate ions. ROXY 30 has no restrictions for use and exploitation due to any medical or physiological conditions of user. SAFETY PRECAUTIONS SCSR should be protected from mechanical damages, which can break the case, lid, seal, cartridge and other components. It is prohibited to sit on self-contained self-rescuer. Do not leave close to working machines or equipment. Do not expose to heat. Open SCSR only for proper use donning and escape in case of emergency. Keep unsealed and used SCSR away from liquid or solid flammable materials. Damaged SCSRs where oxygen-containing product has direct contact with ambient atmosphere shall be immediately withdrawn from service, delivered to the surface of mine and disposed in accordance with Disposal. Self-rescuer should be protected from combustibles and other flammable materials. It is also not allowed to keep used SCSRs with the ones that are in storage. DANGEROUS! If self-rescuer is damaged, the oxygen containing product can cause ignition of coal, wood or other flammable materials. 4

DEZEGA ROXY 30 (SANS 1737:2008) TECHNICAL DATA Rated duration in accordance with SANS 1737:2008 - at 35 l/min (escaping from dangerous environment) 30 1 min - at 50 l/min (heavy physical activity) 18 min Breathing resistance at 35 l/min, max 1,0 kpa Breathing resistance at 50 l/min, max 1,5 kpa Total breathing resistance at 35 l/min, max 1,6 kpa Inhaled gas temperature, max 65 С Temperature on the surface of the case at 35 l/min, max 90 С Temperature on the surface of the case at 50 l/min, max 100 С Temperature on the surface of regenerative cartridge at 35 l/min, 150 C max Temperature on the surface of regenerative cartridge at 50 l/min, 180 C max Volume of oxygen in the inhaled gas, min 21% Average volume of CO 2 in the inhaled gas 1,5% Maximum content of CO 2 in the inhaled air 3% Volume of breathing bag, no less than 5 l Weight 2,0 kg Dimensions: - Height - Length - Width 176 mm 182 mm 85 mm Temperature for usage -5 +60 С Relative humidity up to 100% Ambient pressure up to 133,3 kpa Service life 5 years 2 Shelf life 6 years 1. Depending on respiration rate, physical and medical conditions of wearer rated duration may be increased. 2. In case of observing operating procedures of current User s manual 5

ROXY 30 (SANS 1737:2008) PRIOR TO USE DEZEGA ROXY 30 shall be checked prior to daily using: sealing of lid and case is not damaged; cover and lock lever are not damaged; seal and safety pin are not damaged; lid and case are not damaged and have no cracks, holes or splits; belt loops are not damaged and fixed on the case; moisture indicator is blue and not damaged. ROXY 30 shall be immediately withdrawn from the service if at least one of indicated requirements are not satisfied Regular visual inspection of moisture indicator allows to control normal operating condition of SCSR without special equipment. Blue colour of indicator is a sign of normal operating condition. 6 WITHDRAW ACCEPT If moisture indicator change its colour to pink and/or white, ROXY 30 shall be checked using a leak testing machine (UPG or analogue) by positive pressure 50 kpa (500 mm w.c.). If pressure drop is less than 400 Pa (40 mm w.c.) within 15 sec, ROXY 30 may be used up to 10 days. After the expiry of 10 days, ROXY 30 shall be withdrawn from the service. If pressure drop is more than 400 Pa (40 mm w.c.) within 15 sec, then ROXY 30 shall be immediately be withdrawn from the service. Withdrawn SCSRs shall be placed into the individual tightly closed plastic bag and sent to the authorized service center or representative for a decision about further using.

DESIGN DEZEGA ROXY 30 (SANS 1737:2008) 8 1 2 3 9 10 11 12 1 4 5 6 7 13 14 15 16 17 18 19 20 1. Upper lock lever 2. Lid 3. Back cover 4. Moisture indicator 5. Goggles 6. Regenerative cartridge 7. Breathing bag 8. Seal 9. Lower lock lewer 10. Safety pin 11. Marking 12. Belt loops 13. Sealing 14. Heat shield 15. Breathing hose 16. Neck strap 17. Plug 18. Chest strap 19. Nose clip 20. Mouthpiece 7

ROXY 30 (SANS 1737:2008) CARRYING METHOD DEZEGA Everyday on a waist belt. It is recommended to use a specially designed waist belt DEZEGA-Belt. RECOMMENDATIONS FOR USING, RECORDKEEPING AND HANDLING Prior to putting into service it is necessary to check ROXY 30 for leakage using UPG (or other, if specified) in accordance with «Prior to use». Appropriate unique number for deployed SCSR and record this information according to template form (Annex A). SCSR shall be used by each worker individually. Reserved (not individual) SCSRs are recommended to record in the template form (Annex B). Service life will be calculated from the date of manufacturing if there is no information about SCSR date of commissioning in accordance with «Annex A». Take SCSR from lamp room and perform a visual check in accordance with Prior to use prior to descending into the mine. It is prohibited to store and leave ROXY 30 close to heat-radiating devices, wash by water and use as support arrangement and sitting. It is allowed to clean SCSR by wet cloth. 8

DEZEGA ROXY 30 (SANS 1737:2008) OPERATING PRINCIPLE To start the reaction of oxygen release and absorption of carbon dioxide it is necessary to do few exhalations through mouthpiece. Exhaled air goes through the mouthpiece and heat and moisture exchanger via the breathing hose to the regenerative cartridge. In the regenerative cartridge, the exhaled gas is purified from carbon dioxide, enriched by oxygen and then goes into the breathing bag. Surplus breathing gas is removed from breathing bag via relief valve. ROXY 30 has a pendulum scheme of airflow. When user makes an inhalation, the breathing gas goes backwards: from breathing bag through the cartridge via breathing tube to the heat and moisture exchanger, mouthpiece and to the user s respiratory system. The absorption of carbon dioxide and production of oxygen in regenerative cartridge is exothermic (producing heat). This temperature increase will be felt by the wearer on the casings and in the inhaled gas. Warming of case and inhaled gas indicate normal operation of SCSR. 9

ROXY 30 (SANS 1737:2008) DONNING PROCEDURE DEZEGA In case of emergency immediately don the SCSR. To activate Roxy 30 do the following: Step 1: - rotate the Roxy 30 on your waist belt to the front of your body; - kneel down; Step 2: - slightly rise SCSR with both hands, remove safety pin with middle fingers of both hands by moving toward you and break the seal; 10

DEZEGA ROXY 30 (SANS 1737:2008) Step 3: - hold the SCSR with one hand, detach the lock lever with another hand lifting it down and throw the lock lever away; - lift off the lid and remove the self-rescuer from the case; - turn the lid over, take the red side of neck strap in hand, detach the self-rescuer from the lid and throw the lid away; Step 4: - remove helmet; - put on the neck strap; 11

ROXY 30 (SANS 1737:2008) DEZEGA Step 5: - remove plug from the mouthpiece and straighten the breathing hose; - handle the mouthpiece with both hands, move close to the mouth, exhale several times into SCSR s mouthpiece till breathing bag fully inflates and relief valve opens; - put the mouthpiece into your mouth so that its plates are positioned between lips and gums, clench the tooth grips with your teeth; - place the nose clip on your nostrils; You are already isolated from the surrounding atmosphere! Step 6: - put on the protective goggles; - put on helmet; - continue to breathe calmly through your mouth; - adjust the neck strap avoiding stretching of breathing hose and feeling the weight of SCSR in the mouth; - wrap the long side of the chest strap around your body and fasten it to the short side of the chest strap; - adjust the length of the neck and chest straps if necessary, do not overly tighten; - keep calm and escape from the hazardous area. 12

DEZEGA ROXY 30 (SANS 1737:2008) When adjusting the neck strap length hold the self-rescuer so that the mouthpiece is not pulled out from the mouth by the weight of the case. The total time of ROXY 30 donning should take no more than 15 seconds. IMPORTANT ESCAPE RULES leave the emergency site walking evenly. Running and fast walking are not recommended because it may tear your breathe and need more amount of oxygen. walk slower or stop in case of any breathing difficulty, recover normal breathing rhythm and then continue walking. plan your way and chose shortest way to the whiff of fresh air or to the refuge or rescue chamber. keep mouthpiece tight between teeth and lips. inhaled breathing gas is warm and dry; it shows normal working condition of SCSR. Unusual taste of inhaled gas is safe and permissible. do not squeeze of breathing bag and protect from mechanical damages: it may cause oxygen loss. It is not allowed to take out mouthpiece or talk through it, remove nose clip or inhale the surrounding air before getting to the safe place. in case of neediness to vomit or remove saliva from mouth cavity, then squeeze breathing tube when breathing bag is completely filled and remove mouthpiece from mouth. It is prohibited to vomit and splitting into mouthpiece and breathing tube. Next inhalation and exhalation perform via mouthpiece. Do not inhale gases from ambient irrespirable atmosphere. Gradual heating of case sign about normal working condition of SCSR. : depends on respiratory load and allowable to user dressed in cotton garment in the end of rated duration. 13

ROXY 30 (SANS 1737:2008) DEZEGA ROXY 30 is for single use only. Do not reuse it after leaving the dangerous zone and doffing. After reaching the place of safety, remove mouthpiece from the mouth and nose clip and put SCSR aside away from combustibles. Do not lump SCSRs together. After that, deliver SCSR to the lamp room for further disposal in accordance with «Disposal». TRAINING Training is obligatory. ROXY 30 can be used only by trained users and users who complete practical training of donning and using SCSR. Training should performed in accordance with the safety regulations on mine and recommendations stated in this User s manual. It is recommended to perform first training under the supervision of qualified instructors in training room. Training program includes studying this User s manual as well as practical training of donning SCSR, using Training device with imitative cartridge. Total time of donning SCSR shall be less than 15 seconds. Attainments of breathing with SCSR need regular training and consolidation of knowledge. Insufficient training may cause panic in case of emergency and inhalation of dangerous gases from irrespirable atmosphere. To avoid panic reaction we strongly recommend performing training using Training device when recruiting and then once per 2 years. Training device with training regenerative cartridge completely imitate donning and breathing conditions of real SCSR: increase of temperature of inhaled gas, breathing resistance, increase of O 2 and CO 2 concentrations. Practical training can be held in classroom, smoke gallery, training gallery or mine. 14

DEZEGA ROXY 30 (SANS 1737:2008) SERVICE AND MAINTENANCE INSPECTION No special technical service is required for storage and operation of Roxy 30. Maintenance inspection consists of: daily controls; periodical controls with participation of executives from ventilation and mine occupational safety departments. Daily control is a visual inspection in accordance with Prior to use and visual inspection at the end of shift. Daily control at the end of shift include: cleaning of SCSR from dust and dirt with the use of wet cloth; visual inspection of moisture indicator; continuity of case and lid, as well as continuity of all external components and details. Periodical control of deployed SCSR should be performed once per 3 (three) months, for SCSR cashed underground once per 6 (six) months. Periodic control includes: visual inspection of case and lid and continuity of all external details and components. for SCSR with moisture indicator visual check of indicator s colour. Normal operation colour is blue. SCSR is not leaktight if indicator changes colour to pink and/or white. leak test using leak testing machine UPG with positive pressure 5 kpa (500 mm w.c.). SCSR is leaktight and suitable for using if pressure drop in device chamber is lower than 400 Pa (40 mm w.c.) within 15 sec. SCSRs, which didn`t pass leak test, shall be immediately withdrawn from service, placed into individual tightly closed plastic bag and sent to the authorized service center or authorized representative for decision about further using. SCSRs that were withdrawn from service should be delivered to the service center in 10 days. 15

ROXY 30 (SANS 1737:2008) DEZEGA It is recommended to store and register date and results of periodical controls and routine repairs of each SCSR in lamp room within service life of unit. Service life is guaranteed only in case of regular performing of daily and periodical maintenance inspection and service as well as service maintenance in authorized service center if necessary. Damaged SCSRs, unable to undergo service maintenance, must be disposed and utilized in accordance with «Utilization». DISPOSAL ROXY 30 is a subject of obligatory disposal. Strongly forbidden to combust, throw away as a garbage or in municipal or industrial disposal sites and leave underground as well as perform disposing on own authority or commit to the unauthorized organizations. Damaged SCSR, where chemical oxygen (КО 2 ) has direct contact with ambient atmosphere, shall be immediately delivered to the mine s surface and neutralized disassembled: with dismounted case, lid, breathing bag and breathing tube. Disconnect cartridge from case and submerse it by branch tube upwards into pin or other tank with water for 5-10 cm lower of water level. After ending of quenching reaction (ending of oxygen bubbling) shake apparatus and submerse it in the water again, repeat it 3-4 times. Then, apparatus with regenerative cartridge and other elements shall be sent to authorized organization for disposal. Neutralization of regenerative cartridge should be held according to rules of safety and with the use of personal protective equipment: protective rubber gloves and glasses, filtering respirator, rubber footwear and protective clothes. Neutralize formed alkaline solution with 3 % acid, for example, hydrochloric acid (HCl) and drain remaining fluid into a special place of deposit. If damaged SCSR, in which KO 2 has direct contact with ambient atmosphere, is polluted with combustive and lubricating materials then quenching with water is not allowed. Polluted SCSR shall be sent for disposal immediately. When it is impossible to immediately send polluted SCSR for disposing then it should be organized safe storage of such apparatus outside the lamp room. 16

DEZEGA ROXY 30 (SANS 1737:2008) Rejected SCSRs because of: inability to undergo service maintenance, mechanical damages, destruction, unsealing, opening, exhausting, expired lifetime, using as intended, shall be withdrawn from service and disposed. Disposal should be performed in accordance with local legislation and recommendations indicated in this User s manual. Organizations which perform disposal should have: formal license for disposal of SCSR and neutralizing of chemical oxygen (class of hazard 5.1); official authorization letter (certificate) from original equipment manufacturer with regulations and permit for utilization. SCSR s, decommissioned for disposal shall be placed in special dry storing room and kept at least 1 m away from heating devices. Avoid contacts of decommissioned SCSR with water, oil, organic liquids and new SCSRs. 17

ROXY 30 (SANS 1737:2008) MARKING AND SEALING DEZEGA ROXY 30 is marked on the regenerative cartridge, case, breathing bag with the following information: Case: On external side: trademark «DEZEGA» and product index «ROXY 30»; On wearer side: trademark «DEZEGA», product index «ROXY 30», number of standard SANS 1737:2008, rated duration «30 min», serial number in the format of SSSS P MM YYYY where: SSSS sequential serial number; Р letter of producer: T Turkey, U Ukraine, R Russia MM YYYY production date in the format of month-year, inscription «Designed in RSA», which means place of design, and «Made in Turkey» place of production. Picture of donning procedure. On lateral side of case: serial number in the format of SSSS P MM YYYY. Regenerative cartridge day, month and year of cartridge production; Breathing bag serial number in the format of ХХХХ month and year of production. 18

DEZEGA ROXY 30 (SANS 1737:2008) Package marking include: handling signs: «Handle with care, fragile»; «Protect from heat»; «Keep dry»; «This side up»; warning sign «Do not throw»; main, additional and informational inscriptions; marking with the name of SCSR «ROXY 30» as well as indication of hazardous cargo (5.1) are allowed. ROXY 30 is sealed by the original equipment manufacturer or authorized service center. Seal contains trade mark. Seal should be kept intact during entire shelf life. The seal can be removed only while donning the self-rescue. RULES FOR STORAGE AND TRANSPORTATION SCSR must be stored indoors at ambient temperature from +5 C to +40 C and up to 80% relative humidity (at temperature 25 С). Ambient air should not contain pollution of aggressive gases, which may occur corrosion of materials. Boxes with SCSR shall be protected from direct sunlight exposure and keep at least 1 m away from heating devices. SCSR between shifts shall be stored in lamp room on shelves at ambient air from +5 C to +40 C and up to 100% relative humidity (at temperature 25 С). It is prohibited to throw on the floor SCSR and heap together. It is prohibited to store suitable SCSR with used. SCSR of collective storage shall be placed in sealed containers, located on exit routes in mines or in tunnels. SCSR can be transported in the closed and dry compartments of any kind of transport at ambient temperature from 50 C to +50 C and up to 100% relative humidity (at temperature +25 C) separately from flammable and aggressive materials. 19

ROXY 30 (SANS 1737:2008) DEZEGA In case of transportation by air a freight compartment of the aircraft should be airtight and heated. Transporting of SCSR is performed according to rules of transportation, applied to the current type of transport. DANGEROUS! A self-contained self-rescuer ROXY 30 should be transported, stored and used only according to the rules, described in this «User s manual». Any violations of this manual can cause failures in operation of SCSR which can lead to a serious injury or cause death. 20

DEZEGA ROXY 30 (SANS 1737:2008) WARRANTY Original equipment manufacturer warranties appropriates performance characteristics of ROXY 30 while meeting of transportation, using and storing rules indicated in this User s manual. Total warranty period of all joints of SCSR and its working parameters is 12 (eighteen) months from date of commissioning, but no more than 18 months from date of production. Additional warranty information is indicated in purchasing contract. Warranty does not cover SCSR with damaged outer joints and case caused by violation of conditions indicated in this «User s manual». Original equipment manufacturer and keeper of original design documentation reserves the right to change design applied to SCSR for the purpose of improvement of technical and service characteristics as well as service maintenance. DEZEGA SP GÜVENLİK ÜRÜNLERİ SANAYİ VE TİCARET ANONİM ŞİR- KETİ EGE SERBEST BÖLGESİ ZAFER SB MAH. NİLÜFER SK.NO:30 GAZİEMİR, İZMİR Tel. Fax. press@dezega.com www.dezega.com 201606.ROXY30.SANS.RSA.EN 21

ROXY 30 (SANS 1737:2008) DEZEGA Surname, Name Employee Code Position Workshop Mine registration log book for self-contained self-rescuers (Name) No of SCSR Date OEM s Mine s SCSR s manufacturing Commission-ning Decommis-sioning Par 1. Personal SCSR Par 2. SCSRs in changeover stations Par 3. Reserved SCSR ANNEX А Shipment for disposal, of act 22

DEZEGA ROXY 30 (SANS 1737:2008) ANNEX B Mine registration log book for reserved self-contained self-rescuers for mine workers and outside organizations Employee Code Position Serial No of SCSR Name, Surname Company (name) Date SCSR Using SCSR Returns 23