FULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE

Similar documents
Solenoid Valves used in Safety Instrumented Systems

SPR - Pneumatic Spool Valve

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

DeZURIK. KSV Knife Gate Valve. Safety Manual

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual

Solenoid Valves For Gas Service FP02G & FP05G

Pneumatic QEV. SIL Safety Manual SIL SM Compiled By : G. Elliott, Date: 8/19/2015. Innovative and Reliable Valve & Pump Solutions

Bespoke Hydraulic Manifold Assembly

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions

Hydraulic (Subsea) Shuttle Valves

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

Neles trunnion mounted ball valve Series D Rev. 2. Safety Manual

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

Jamesbury Pneumatic Rack and Pinion Actuator

EMERGENCY SHUT-DOWN RELIABILITY ADVANTAGE

Section 1: Multiple Choice

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

Safety manual for Fisher GX Control Valve and Actuator

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

High performance disc valves Series Type BA, BK, BW, BM, BN, BO, BE, BH Rev Safety Manual

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

L&T Valves Limited SAFETY INTEGRITY LEVEL (SIL) VERIFICATION FOR HIGH INTEGRITY PRESSURE PROTECTION SYSTEM (HIPPS) Report No.

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Section 1: Multiple Choice Explained EXAMPLE

SIL explained. Understanding the use of valve actuators in SIL rated safety instrumented systems ACTUATION

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

Failure Modes, Effects and Diagnostic Analysis

Understanding the How, Why, and What of a Safety Integrity Level (SIL)

High Integrity Pressure Protection Systems HIPPS

Valve Communication Solutions. Safety instrumented systems

Safety Manual VEGAVIB series 60

The Key Variables Needed for PFDavg Calculation

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Failure Modes, Effects and Diagnostic Analysis

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

Technical Data. Dimensions

Rosemount 2130 Level Switch

SIL Safety Manual for Fisherr ED, ES, ET, EZ, HP, or HPA Valves with 657 / 667 Actuator

Failure Modes, Effects and Diagnostic Analysis

Technical Data. Dimensions

Technical Data. Dimensions

Every things under control High-Integrity Pressure Protection System (HIPPS)

Gas Hydraulic Valve Operator

Technical Data. General specifications Switching element function Rated operating distance s n 1.5 mm

Safety Manual VEGAVIB series 60

PressureGuard. Self-Contained Hydraulic Emergency Shutdown Systems For Rotary or Non API 6A Linear Valves

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Achieving Compliance in Hardware Fault Tolerance

Intrinsically safe solenoid valves on/off controls - ATEX certification

Failure Modes, Effects and Diagnostic Analysis

Electro-Pneumatic Converter YT-940 SERIES

OPERATION MANUAL PNEUMATIC VALVES

AMT-Ex Dewpoint Transmitter

OIL+GAS PRODUCTS AND THEIR APPLICATIONS

Technical Data. General specifications. Rated operating distance s n 2 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Safety Manual OPTISWITCH series relay (DPDT)

Failure Modes, Effects and Diagnostic Analysis

Ultima. X Series Gas Monitor

Technical Data. General specifications. Rated operating distance s n 5 mm

Failure Modes, Effects and Diagnostic Analysis

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

H250 M9 Supplementary instructions

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Failure Modes, Effects and Diagnostic Analysis

Technical Data. Dimensions

Valvex Valves for Mining Applications

SERVOTOUGH Oxy (1900)

Reliability of Safety-Critical Systems Chapter 4. Testing and Maintenance

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Pressure & Temperature Switches

Technical Data. Dimensions

Inductive slot sensor

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm

VS18/26 with PROFINET and EtherNet/IP Interface. ATEX Installation Instructions

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

COMPLIANCE with IEC EN and IEC EN 61511

Torque Tube TB300 Digital Transmitters

THE NATURAL CHOICE. High end valves for the natural gas value chain. Inspired By Challenge

Technical Data. Dimensions

BERMAD Fire Protection Hydraulic Control Valves

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic

Failure Modes, Effects and Diagnostic Analysis

ELECTRIC ACTUATORS for continuous underwater use

Partial Stroke Testing for SRD991 and SRD960

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Technical Data. Dimensions

Special Documentation Liquiphant M/S with electronic insert FEL56 + Nivotester FTL325N

A Complete Solution For HIPPS

Data Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic

Micro Motion 7812 Fiscal Gas Density Meter

Pressure switch, Differential pressure switch and Thermostat RT-E

Failure Modes, Effects and Diagnostic Analysis

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

Transcription:

FULL STAINLESS STEEL EXPLOSION-PROOF SOLUTIONS OIL & GAS I OFFSHORE AND ONSHORE

ASCO Numatics ASCO Numatics is the world leader in design, manufacturer of solenoid valves and accessories for both offshore and onshore industries. Over many years, ASCO Numatics has increased its offshore and onshore capabilities to meet the most demanding process applications in the Oil & Gas sector. ASCO Numatics FULL STAINLESS STEEL EXPLOSION-PROOF range provides reliable solutions for high integrity applications such as HIPPS, emergency shut-down, gas pipelines, high temperature, cryogenic, corrosive and sour services (NACE compliance), where proven experience and safety are paramount. ASCO Numatics capability in the Oil & Gas industry includes solutions for actuation partial stroke testing (PST), less downtime through redundancy, diagnostics capability, easy accessibility for online-maintenance as well as explosion-proof/ SIL-capable certification. Our full stainless steel explosion-proof products are specifically designed to suit harsh offshore environments; eliminating explosion risks, providing longer operating lifespan, higher repeatability and reducing equipment down-time costs to achieve reliable performance and better profitability. The products also provide offshore & onshore customers with robust protection (IP65-67) against any potential ingress. ASCO Numatics products comply with the various regional regulatory and industrial safety standards such as SIL, ATEX, IECEx, CE, UL, FM, TIIS, TestSafe, Simtars, ITACS, CSA, NEPSI, KOSHA & NACE. ASCO Numatics has an extensive network of manufacturing, engineering, sales and distribution locations throughout Asia Pacific to respond swiftly to customers needs. With over 1 years experience worldwide, ASCO Numatics provides complete solutions and ensures the highest product quality and reliability in hazardous environments. The continuous efforts towards improvement, innovation and delivering better products for the industry make ASCO Numatics a reliable partner for customers. BENEFITING TODAY & TOMORROW

Stainless Steel Solenoid Valves 327 Standard Valve Low ambient & high ambient temperature, Manual override, ¼ 327 Redundant Valve.5 w 1 bar 3/2 Way Universal (Redundant) 1 bar 1.8 w Removable/ Lockable Manual Override, 3/2 Way Universal 1 bar Low power 1.8w, basic power 1 w Low ambient & high ambient temperature,, tamper proof 327 Intrinsically Safe Valve II1G Ex ia IIC T6 Ga, II2D Ex tb IIIC Db 1 bar Low power 1.5w, basic power 1 w 327 Removable Manual Override Valve 327 Manual Reset Valve 327 Offshore Valve 1 bar Low power 1.5w, basic power 1 w 327 Arctic Valve Manual override,, low ambient & high ambient temperature Direct acting for -5 deg C ambient All technical information shown in the above table, are only valid for selected valve & coil combinations. To find out the correct part number, please refer to the latest catalog datesheet. 3.6 w Low ambient & high ambient temperature, 1 bar 1 bar Low power 1.8w, basic power 1 w Manual override,

Stainless Steel Solenoid Valves 3/2 way NO 551, 552&553 Valve Pilot operated 3/2 & 5/2 Way UL/ CSA Class 1 Div 1 & 2, Group A, B, C, D (Type 7) Ex d, Ex m, Ex ia, Ex md, IIC T6 F & 1 bar 1 bar <5w 327 Latching Valve IP65 to 3/2 Way Universal ½ 2 ½ F & Special Feature Enclosure Type Rating 21 Valve 1 bar 3.6 w (1/4 ), 1 w (1/2 ) /.35 1 bar 6-16.8 w Manual override & Pilot Operated 3/2 Way, Universal & NC UL/ CSA Class 1 Div 1 & 2, Group A, B, C, D (Type 7) NACE MR 175 compliance & Pilot Operated IP66 ¼ F class 3/2 & 5/2 Way UL/ CSA Class 1 Div 1 & 2, Group A, B, C, D (Type 7) Ex d, Ex m, Ex ia, Ex md, IIC T6 Type 1, 2, 3, 3S, 4, 4X, 6 and 6P Harsh Environment Valve F & NACE Shielded Core (Universal) Low Power Valve 2 way NC & NO UL/ CSA Class 1 Div 1 & 2, Group A, B, C, D (Type 7)Ex d, Ex m, Ex md, IIC T6 Pilot operated Special Feature NACE Valve Design for fire deluge system.5w, 1.4 w, 1.8w, 11.2 w Namur, low ambient & high ambient temp &.35-1 bar.55 w, 1.4 w, 1.8w Manual reset, Low ambient & high ambient temp All technical information shown in the above table, are only valid for selected valve & coil combinations. To find out the correct part number, please refer to the latest catalog datesheet. 361 Offshore Valve 1 bar.55w, 1.3 w Pilot Operated 3/2 way UL/ CSA Class 1 Div 1 & 2, Group A, B, C, D (Type 7)Ex d, Ex m, Ex ia, IIC T6 IP65 to 67 ¼ F &.35-1 bar.55w, 1.8 w, 11.6 w Air operated, manual operated

Full Stainless Steel Filter Regulators & Accessories Together with the full stainless steel solenoid valves, ASCO Numatics filter regulator is designed to suit the most demanding environments. Both the external & internal construction is in full stainless steel material. The robust design enable longer lifespan, higher flow rate, 5 25 µm Port Size Flow Rate operator control. Complying with NACE MR 175 and ATEX II 2G/D IIC standards. Filter Capacity effective moisture removal and better pressure regulation with finer 342 Pressure Regulation & Filtration II 2G/D c IIC T1 C 245 443 l/min.5 1. bar NACE, Low Ambient, Auto Drain options Systems and Solutions For complete functional safety and enhanced reliability, ASCO Numatics developed systems and solutions to meet customers special requirement. Redundant Control System (RCS) The solenoid pilot valve system that focus on maximum reliability for most critical ESD valve in the process plant. Operated under 1oo1HS or 2oo2D mode and SIL 3 (capable), RCS achieves a higher level of Redundant Control for High Availability 3/2 way NC, NO. 5/2 way II 2G Ex d e mb IIC IP56 process safety and reliability by using a redundant, fault tolerant architecture with high diagnostic coverage and automatic solenoid F class valve testing & actuator partial stroke testing. A keyed bypass allows live maintenance of the solenoid without process interruption. RCS 1 bar 1.4w, 1.1w Bypass for on-line testing & easy maintenance 3/2 way NC, NO. 5/2 way Bypass Test Panel With a keyed bypass unit, on-line testing of solenoid valve and II2 GD EEx d IIC T6 replacement/maintenance of faulty solenoid valve can be done IP65-67 without interruption to the ongoing process. An optional feedback unit is available to provide status to the control room. Bypass Test Panel F & 1 bar.5w, 1.8w, 3.6w, 5.7w, 1.1w, 14w Actuator Control System (ACS) Modular design with solenoid valves, filter regulator and other 3/2 way NC, NO. 5/2 way accessories pre-fabricated in accordance to customer s requirement. Ex d, Ex md, Ex i It is light weight, compact and reduces installation time. It also helps IP65-67 to drive down fittings, tubings and even back-plate costs signifi- F & 1 bar cantly. ACS Modular System for Compact Usage.5w, 1.8w, 3.6w, 5.7w, 1.1w, 14w

ASCO Numatics IECEx I ATEX Certification Strengths: Ex Certificate / Certificat Zertifikat / ASC 1311 C5 Certificate / Certificat / Zertifikat / exida hereby confirms that the: The manufacturer may use the mark: Series 551, 552, and 553 Pilot Operated Inline Spool Valves Systematic Capability: SC 3 (SIL 3 Capable) ASCO Numatics Lucé, France SIL 2 @ HFT=; SIL 3 @ HFT = 1; Route 2H ASC 1311 C5 Random Capability: Type A Element PFDAVG and Architecture Constraints must be verified for each application Has been assessed per the relevant requirements of: IEC 6158 : 21 Parts 1-7 SC 3 (SIL 3 Capability): Series 551, 552, and and meets requirements providing a level of integrity to: Systematic Capability: SC 3 (SIL 3 Capable) Random Capability: The SIL limit imposed by the Architectural Constraints for each element. Random Capability: Type A Element Report: ASC Q1311 R3 V1R1 Assessment Report Valid until February 28, 216 Revision 1.1 March 25, 213 The product has met manufacturer design process requirements of Safety Integrity Level (SIL) 3. These are intended to achieve s ufficient integrity against systematic errors of design by the manufacturer. A Safety Instrumented (SIF) designed with this product must not be used at a SIL level higher than stated. IEC 6158 Failure Rates in FIT* SIL 2 @ HFT=; SIL 3 @ HFT = 1; Route 2H For valves used in a final element assembly, SIL must be verified for the specific application using the following failure rate data. PFDAVG and Architecture Constraints must be verified for each application Failure rates for the Series 551,552, and 553 Pilot Operated Spool Valves in FIT* Failure Category Safety : The Valve will move to the designed safe position when deenergized / energized within the specified safety time. 3/2 Single Application Restrictions: The unit must be properly designed into a Safety Instrumented per the Safety Manual requirements. Place embossed seal here for originals, lining it up at the bottom ANSI Accredited Program PRODUCT CERTIFICATION #14 sd su 178 dd du 347 3/2 Single NAMUR 273 371 3/2 Single, w/nf Operator 292 333 3/2 Single NAMUR, w/nf Operator 386 358 3/2 Redundant 25 5/2 Single 278 357 5/2 Single NAMUR 275 389 5/2 Single w/nf Operator 392 343 387 5/2 Single NAMUR, w/nf Operator 388 376 5/2 Redundant 265 397 Applications Evaluating Assessor Series 551/552/553 De-energize on trip, normally closed Spool Valves SIL Verification: The Safety Integrity Level (SIL) of an entire Safety Instrumented (SIF) must be verified via a calculation of PFDAVG considering redundant architectures, proof test interval, proof test effectiveness, any automatic diagnostics, average repair time and the specific failure rates of all products included in the SIF. Each subsystem must be checked to assure compliance with minimum hardware fault tolerance (HFT) requirements. The following documents are a mandatory part of certification: Assessment Report: ASC Q1311 R1 V1R1 Assessment Report Safety Manual: V9629, Rev B * FIT = 1 failure / 19 hours Certifying Assessor Page 1 of 2 Page 2 of 2 CONTACTS Asia Pacific Australia 61-2 - 9451-777 China 86-21 - 3338-73 India 91-44 - 3919-73 Japan 81-798 - 65-6361 Korea 82-234 - 83-157 New Zealand 64-9 - 478-192 Singapore 65-6556 - 11 Taiwan 886-2 - 8912-1233 Mail: APmarketing.asco@emerson.com ASCO Numatics Singapore Blk 48, Ang Mo Kio Avenue 1 # 4-17/22, TECHplace 1, Singapore 569625 Tel: 65 6556 11 Fax: 65 6556 11