POOL WATER MAINTENANCE SYSTEMS WALLACE & TIERNAN PRODUCTS AND SERVICES

Similar documents
V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

The best water for your pool from a single source.

It s safe for swimmers to take the plunge with ProMinent Tailor-made complete solutions for pure pleasure in the pool

fact file use of UV in swimming pools The use of UV for destruction of combined chlorine Ing A Beyer, Ing H Worner and BaE R van Lierop

MANAGEMENT IN WATER.

DELTA UV RESIDENTIAL ULTRAVIOLET DISINFECTION SYSTEMS

Title of presentation

11. Aquasalt. Aquasalt Aquasalt 440. Salt electrolysis demonstration 442. Spare parts and Accessories 443. Chemical Products

Pool and Spa. Water Testing

DELTA-UV ULTRAVIOLET DISINFECTION SYSTEMS

hth EASIFLO SYSTEM New Generation for 2015 Feeder specifications hth EASIFLO The perfect solution for treatment of commercial swimming pools

V10K GAS FEED SYSTEM

Capital Controls Series NXT3000 Modular design gas feed system with self-contained automatic switchover capability.

SALT CHLORINATOR RANGE CATALOGUE

S A W A Y G E N E R A L T R A D I N G L L C. Page 1- FLOATING DISPENSERS CHLORINE AND ph TEST KIT TEST KIT REFILL BOTTLE 123

EasyLine Continuous Gas Analyzers. So smart, they re simple

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

UsER manual for Watersens ph -REDOX

CAPITAL CONTROLS SERIES NXT3000

1- CHLORINE 2- NEUTRALIZER 3- BROMINE 4- FLOCCULANT. 5- ph MINUS. 6- ph PLUS 7- WASP REPELLENT 8- NET'BORD 9- ALGAECIDE 10- WINTERIZING

CORI-FLOW PRECISION MASS FLOW METER / CONTROLLER FOR LIQUIDS AND GASES

CCS240 and CCS241. Technical Information. Sensors for chlorine dioxide Amperometric, membrane-covered sensors for installation in the CCA250 assembly

CRYSTAR FT CERAMIC MEMBRANE FILTERS for pool water preparation

KREEPY KRAULY. Anytime from anywhere on earth. Pool monitoring and control system.

AUTOMATIC HOSE TEST UNIT, TYPE SPU

VACCUPERM Vacuum chlorine gas dosing systems

swimming pool technology

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

These variables can be accessed by holding the UP button for 5 seconds.

KRONES filling systems for beer Filling of glass containers and cans

SWIMMING POOLS. Catalogue 2017

PRC CO ² -LASER PRESENTATION

Cleaning robots for swimming pools - fully automatic, persistent and powerful YOUR PARTNER FOR SWIMMING POOL HYGIENE

G.B. Collins Engineering, P.A. Comments to Proposed Code Modification SW7074-A1

HumiSys HF High Flow RH Generator

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

Real-time gas analysis and software for the management of bioprocessing

MEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Guide to DPD Testing in Pools and Spas. Application Support Information

Nothing's as cool, as a freshwater pool. easychem 770 ORP and ph Controller for Pools and Spas with Timer Output for Pool Pump

Countrywide Pools Northam

Press Release. Friction Stir Welding: Grenzebach extends its portfolio

Waste Management System.

deltaflowc deltaflowc Venturi or Probe

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

Ingersoll Rand. X-Series System Automation

SAFE. The ChemfloPlus s Smart LCD display shows you the condition of your pool water and what ChemfloPlus is doing about it.

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Improve Process Reliability

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Precision Mass Flow Meters / Controllers for Liquids and Gases

Traysealer T 100. Tray packaging in the smallest space

Model 601CV. Mass Flow Controller. Product Features:

SRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

ABB MEASUREMENT & ANALYTICS. Continuous gas analyzers EL3060 The specialists for hazardous areas

BI-680 Online Dissolved Oxygen Controller Instruction Manual

NZQA registered unit standard version 2 Page 1 of 5

Gas Analysis Isn t Exactly Your Only Priority? Luckily For You, It s Ours. SIPROCESS GA700 effortless gas analytics from Siemens. siemens.

EASYTOUCH. Because automation makes it all so simple. pentairpool.com

Pool and Spa Operator Handbook, Highlight

BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER

Gas Injection Systems

...makes sense! Combined CO 2 /O 2 analyzers. Monitor your process in real-time: OUR CER. BlueSens.com

sorting solutions osx separator series

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Sanitizers. Sanitizers. Sanitizers for Pools & Spas

Tensiometer For the measurement of surface and interfacial tension

BUYER S GUIDE AQUAlogger 530WTD

VACOMASS. The modular air supply system in wastewater treatment plants

Bernhard Thomas September EnCal 3000 prochain Energy in Gas with ROI

LFE OEM TCD - Thermal Conductivity Detector

Exceptional Experience

UT 3000 Mercury Ultratracer

Porter Analytical & Industrial Products

GRUNDFOS CRE range. Customised pump solutions Optimised for water treatment

Tensiometer For the measurement of surface and interfacial tension

Quick Installation Guide Doc nr.: C Date:

Manual. Online Degasser DDG-75. Manual Degasser DDG-75 April DURATEC Analysentechnik GmbH Rheinauer Strasse 4 DE Hockenheim Germany

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

The WIRTGEN GROUP User Magazine // N o 05. WIRTGEN GROUP solutions for automation and process optimization: On the leading edge

Ruskinn Hypoxia and Anoxia Workstations. innovation in incubation

OMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.

Ozone PLUS Germicidal UV Advanced Oxidation Process (AOP) A Synergistic Sanitation Approach for Residential Pools

CHLORINE DIOXIDE GENERATOR

973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS

ADVANCED OXIDATION PROCESS

Commandant United States Coast Guard

Code Basic module and level control complete with optionals code

Highest Quality. Gas Chlorination Systems

deltaflowc deltaflowc Gas Massflowmeter Venturi- and Probe Type

Safety Standards for Canadian Swimming Pools and Waterfronts Swimming Pool Standard

Micro Motion 3098 Gas Specific Gravity Meter

ACV-10 Automatic Control Valve

ONH836 Series: Oxygen/Nitrogen/Hydrogen by Inert Gas Fusion

Title: Standard Operating Procedure for Measurement of Ethylene (C 2 H 4 ) in Ambient Air by Reduced Gas Detection (RGD)

Transcription:

POOL WATER MAINTENANCE SYSTEMS WALLACE & TIERNAN PRODUCTS AND SERVICES

EVOQUA WATER TECHNOLOGIES FACILITIES IN EUROPE GERMANY, GÜNZBURG Evoqua Water Technologies GmbH Auf der Weide 10 89312 Günzburg Phone: +49 8221 904 0 wtger@evoqua.com GREAT BRITAIN, SEVENOAKS Evoqua Water Technologies Ltd. Phone: +44 1 732 771777 info.uk@evoqua.com Evoqua Water Technologies is one of the world s leading providers for water treatment equipment and service. The extensive portfolio includes the Wallace & Tiernan product line with complete solutions for disinfection, chemical feeding, measurement and control systems. About 240 employees work in the facility in Guenzburg. It is center of research & development, production plant and sales and service facility as well. FRANCE, CHAVILLE Evoqua Water Technologies GmbH Phone: +33 1 41 15 92 20 wtfra@evoqua.com AUSTRIA/CEE, GRAZ Evoqua Water Technologies GmbH Phone: +43 664 8855 5464 Ljubinka.Stanisavljevic@evoqua.com TEAMLEADER AQUATICS/POOL WATER SALES IN GÜNZBURG Guenter Conrad Phone: +49 8221 904 210 guenter.h.conrad@evoqua.com Services Spares/Repairs, in house training, training in Guenzburg spares.gz.de@evoqua.com service.gz.de@evoqua.com Po

LAWS AND REGULATIONS Pursuant to section 11 of the German Infection Protection Act, swimming pool water in public pools or commercial operations must be of a high enough quality so that its use is not associated with harming human health through pathogens. To meet this requirement, it is necessary to treat and disinfect swimming pool water. Chlorine and inorganic compounds of chlorine are used as disinfectants. The disinfectant concentrations may not represent a health risk for swimmers or staff. According to DIN 19643, Part 1 Treatment of water of swimming pools and baths, trihalomethanes are unavoidable secondary reaction products of chlorination and, same as the combined chlorine, are considered health hazards. Free chlorine and ph values must be measured, controlled, and recorded continuously according to DIN 19643. This means that automatically controlled dosing systems for the chlorination and ph adjustment must be installed for each swimming and spa pool (exception: cold water plunge pool with content < 2 m³). The redox voltage must be measured and logged continuously using stationary measuring instruments. DIN 19643 IN DETAIL free chlorine pool water in warm water whirlpools combined chlorine in cold water plunge pools < 2 m 3 THMs 0.3-0.6 mg/l 0.7-1.0 mg/l 0.2 mg/l no limits max. 0.020 mg/l ph value, sweet water 6.5-7,5 ph value, sea water 6.5-7.8 redox voltage (ORP), sweet water redox voltage (ORP), sea water min. 750 resp. 770 mv min. 700 resp. 720 mv THE INFECTION PROTECTION ACT AND DIN 19654 ARE BINDING FOR GERMANY. PLEASE NOTE THE RESPECTIVE PROVISIONS IN THE INDIVIDUAL COUNTRIES. SWIMMING POOL SPLASH WATER TANK POOL MANAGEMENT SYSTEM CHLORINATION PH VALUE CORRECTION FREQUENCY CONVERTER FOR ECON POOL- CONTROL ACTIVATED POWDERED CARBON DOSING FLOCCULANT DOSING FILTER UV SYSTEM SLUDGE WATER- RECYCLING- UNIT SLUDGE WATER TANK VARIOUS POSSIBILITIES TO USE WALLACE & TIERNAN PRODUCTS IN POOL WATER APPLICATIONS

EXACT DOSING DUE TO V-NOTCH PROVEN GAS FEED SYSTEMS THE ORIGIN OF THE NAME WALLACE & TIERNAN It has been more than a hundred years ago that the namesakes Charles F. Wallace and Martin F. Tiernan discovered the disinfecting effect of chlorine in water. Still today, Wallace & Tiernan chlorine gas dosing systems are the epitome of safety and accuracy around the globe. All the while the principle has remained the same. Wallace & Tiernan chlorine gas dosing units function based on the full vacuum principle. The V10k full vacuum dosing system is also suitable for dosing carbon dioxide (CO 2 ) to lower ph values. The unit is designed for capacities up to 10 kg/h and features numerous configuration options. The Wallace & Tiernan V-notch control orifice is used successfully worldwide and offers a large control range, very good reproducibility and high dosing accuracy. Pressure/vacuum controllers mounted directly to the gas tank or manifold reduce the pressurized gas to a process vacuum. The pressure/vacuum controller is available in power levels of 4 kg/h, 10 kg/h and higher. SERVICES FOR DISINFECTION SYSTEMS Evoqua Water Technologies not only offers a wide range of systems and devices for water treatment and disinfection, but also a suite of related service offerings. Services for disinfection systems On-site service Service contracts Repairs Technical consulting Use of original spare parts Safety audits performed by qualified personnel Manufacturer service From maintenance on installed systems to optimisation and upgrades, whether for treatment and dosing systems, electrolysis systems, UV disinfection units or measuring and control devices, the comprehensive service toolkit distinguishes Evoqua Water Technologies as partner of choice. V10K FEEDER WITH MANUAL CONTROL

SMALLEST DIOX-A SYSTEM FOR 3 G/H CLO2 ELECTROLYSER CELL OF OSEC B-PAK DISINFECTION METHODS CHLORINE DIOXIDE IN POOL WATER The occurrence of legionellae in pool water is a problem that must be taken seriously. Water used for showering is affected primarily. This water is part of the drinking water system and as such subject to the same rules and regulations. Whirlpools, other water-spraying systems and pool water filters play an important role as well. Since the occurrence of legionellae may result in serious consequences including closure of the bath or pool facility, it is important to implement precautionary and preventative measures. Chlorine dioxide is successfully used for fighting and preventing legionellae. The available treatment and dosing units produce chlorine dioxide starting at 3 g/h and are integrated into the warm water system. The corresponding measuring and control unit offers additional control options. Environment-friendly Experienced technologies: whether UV systems, chlorine dioxide generation and dosing, electrolysers or ultrafiltration for recycling of sludge water recycling OSEC SERIES Sodium hypochlorite is an effective alternate disinfectant wherever fill water has a low acid capacity (carbonate hardness) or if the use of chlorine gas is unadvisable or to be avoided. Since commercially available sodium hypochlorite solutions have a limited shelf life, resulting in loss of active chlorine content, sodium hypochlorite should be generated directly onsite with an electrolysis process. The starting materials are sodium chloride solution (common salt) or in case of salt water pools ocean water. Tubular cell electrolysers The OSEC -B and OSEC B-Pak (brine) and OSEC-S (sea water) systems function as undivided, single-flow electrolysis cells without membranes. The concentration of the prepared sodium hypochlorite solution amounts to approx. 2 g/l active chlorine when using ocean water and approx. 6 to 8 g/l active chlorine when using brine. Membrane electrolysers The OSEC-A unit is designed for smaller pools and generates 12, 25 or 50 g/h chlorine based on the membrane process. The OSEC-NXT chlorine membrane electrolysis system is offered in a power range from 6 kg to 60 kg of chlorine per day. Constant electrode materials, a chlorine free brine solution container and a process that does not recycle brine are the main differences to commonly available chlorine membrane electrolysis systems. It consists of user-friendly touch panel controls and an integrated power control. The underlying process employed by these systems is considered the safest and most economical of all processes used to produce chlorine.

SAVING WITH TECHNOLOGY UFOX 10: SAVINGS THROUGH ULTRA FILTRATIONS The Wallace & Tiernan UFOX sludge water recycling unit recycles filter backwash water in swimming pools. Ultra filtration is the central treatment stage carried out with two UF modules. This recycled water may be used as pool or back wash tank refill water or grey water. The UFOX 10 system treats up to 10 square meters of water per day. Daily, automatically function and integrity tests as well as self-optimizing rinse intervals keep the operation safe. Assuming that the cost for fresh water and wastewater as well as energy amounts to approx. 4 /m 3, a UFOX system can save up to 15,000 annually. Rinsing the pool filter results in sludge water, which is collected in sludge water tanks first and then routed into the sewer. When the UFOX system is used, this water does not go to waste. Instead, most of it is returned to the pool process along with the thermal energy it still carries. The UFOX system is a multi-stage system and ensures that the collected filtrate can be transferred to the overflow tank. The number of water treatment stages required depends on the composition of the sludge water to be treated. Ultra filtration is the central treatment stage; in addition, the UFOX system also contains a pre-filtration and disinfection stage. UV FOR NOTICEABLY IMPROVED WATER QUALITY UV systems are used in pools primarily for the reduction of combined chlorine, chloramines or ozone, respectively. This effect is achieved only with polychromatic lamps based on the medium pressure principle and emitting a corresponding broad wavelength spectrum. These types of lamps are integrated into the Barrier M units. Fewer chloramines in the water also result in an improved pool environment. The Barrier M UV systems for volume flows up to 1000 m 3 /h impresses with its hydrodynamic chamber. The electronic ballast equipment provides the highest possible efficiency to be achieved. The irradiance to be adjusted with pinpoint accuracy using an infinitely variable controller, lets you to optimize the quantity of UV radiation delivered. Evoqua provides high quality lamps and components to extend their life-cycle and reduce costs on their UV disinfection systems. The Barrier M unit is easy to install, maintain and clean. An UV sensor and cleaning mechanism are available as additional equipment. BARRIER M SYSTEM UFOX UNIT

WE MAKE SURE YOU ARE ECONOMIC Contact us to find out how much you could be saving right now: We gladly advise you. The investments will pay for themselves within a very short time, while providing the means to achieve savings. Moreover, you will be employing the latest, modern technology: For optimized operations and safe water fun.

JETPAK ACTIVATED CARBON DOSING SYSTEM Various additives are used in swimming pools to condition water. The types of additives depend on the applied treatment technology and fill water. Wallace & Tiernan systems dose accurately and safely. Please contact us for assistance with technical process questions. SYSTEMS TO CORRECT PH-VALUE According to DIN 19643, ph values are among the hygiene assistance parameters and should be between 6.5 and 7.6. The acid capacity of the water, measured as KS 4,3, is a parameter that affects many procedural steps of the water treatment process. This value should be at least 0.7 mol/m 3, especially for flocculation. Depending on the condition of the raw water, the utilized disinfection method, and the treatment process, different measures to condition the water are used. These include the addition of the following: Marble gravel for neutralization Sodium bicarbonate for hardening Additives to raise/lower ph values (e.g. sulfuric acid, sodium hydroxide) Carbonic acid for neutralization If the chlorine activated process is used, marble gravel is the most economical means to minimize a drop in ph. It stabilizes the acid capacity and helps to achieve good flocculation results. Sodium bicarbonate is also used to increase the capacity of the acid. The Wallace & Tiernan dosing system is a twochamber system: It is geared towards the slow dissolution rate of sodium bicarbonate in water. An additional water softener unit is recommended for hard water. The dosing system can be linked to the control of ph value correction and disinfectant. POWDERED ACTIVATED CARBON DOSING SYSTEMS Powdered activated carbon or a UV system can be used as an adsorption step to adhere with the combined chlorine values prescribed by DIN 19643. Both alternatives are usually more economical than supplying a greater amount of fresh water. Powdered activated carbon is even the substance of choice when the primary objective is to eliminate trihalomethanes. Powdered activated carbon has been proven to improve pool water quality significantly. This means less secondary reaction products of the chlorination process as well as a higher oxidizability of the water. The compact JETPAK powdered activated carbon dosing system uses a special injector and supplies up to three dosing points with the prepared suspension. ACCURATE DOSING OF FLUID SUBSTANCES Evoqua Water Technologies provides sophisticated concepts for the dosing of liquid chemicals, including storage fixtures, dosing station, control unit, as well as the lines to the application points. The Chem-Ad series A to D diaphragm pumps cover a capacity range from 0.2 to 750 l/h. The Chem-Ad VPP/ VPP-E/VPP-S peristaltic dosing pumps meter even small quantities with a level of accuracy and work reliably with degassing liquids such as sodium hypochlorite used as a disinfectant.

DEPOLOX POOL E 700 P POOL MANAGEMENT SYSTEM FREE CHLORINE DISPLAY WITH LINE DIAGRAM WALLACE & TIERNAN ANALYZERS & CONTROLLERS MEASURING AND CONTROL SYSTEMS DESIGNED FOR ANY SWIMMING POOL SIZE: ALWAYS MATCHING NEEDS AND REQUIREMENTS PERFECTLY Pool Management with DEPOLOX Pool E 700 P system The DEPOLOX Pool E 700 P system is the central measuring, control, and regulating unit for public pools. It measures and controls such hygiene assistance parameters as free chlorine and combined chlorine, ph value, redox voltage, and conductivity. Preset applications can be adjusted to meet on-site conditions. The multi function system is usually able to control the addition of chlorine, as well as the ph correction and the flocculant dosing, the UV or the powder activated carbon unit. Additional functions such as economic operating mode reduce the circulation rate if the measured values correspond with DIN 19643 specifications. The redox-based chlorine overfeed control adjusts to the current needs and reduces operating costs. This CEDOX control considers the redox voltage, which expresses the water quality as a composite parameter, as a second control parameter parallel to the chlorine value. This means that the added chlorine is sufficient but no more than required. This saves consumables while still complying with DIN requirements. For the time being the precursor DEPOLOX Pool system is still available PCS plus unit - Well-built and compact Compact and practical, the PCS plus system measures the most important parameters consisting of free chlorine, ph value, redox voltage and temperature. It is available as a standalone unit or complete system with integrated tube dosing pumps. The dual measuring of free chlorine is also possible with the PCS plus unit, for example, when two pool basins are connected to one filter circuit. SFC series SFC series devices are available for the measurement and control of individual parameters. For example, the disinfection of the sludge water tank is controlled with this precise measurement and control technology. GMS plus gas detection system The GMS plus system can be used wherever gases such as chlorine, chlorine dioxide, or ozone are generated, stored and metered. The reliable dual channel measuring system monitors gas concentration and temperature of up to two measuring locations. It uses the tried and tested Chloratekt sensors to measure chlorine, chlorine dioxide, and ozone; other sensors with ma output can be connected as well to measure other gases. Photometer - simple and with perfect timing In conjunction with the P42 i-cal photometer, the DEPOLOX Pool system can be calibrated in real-time using an IR time-stamp function. This function ensures that the calibration is carried out exactly in relation to the measured value at the time of the zero calibration. This optimizes the measurement and control quality of the device and makes it especially accurate. Input errors are not possible. In addition, the photometer P15 plus unit is available to measure the most important water treatment parameters such as chlorine and ph value quickly, reliably and precisely.

PCS PLUS SYSTEM WITH TWO FLOW CELL MODULES FOR DOUBLE MEASUREMENT OF FREE CHLORINE DATA MANAGEMENT PRODUCTS FOR INTEGRATION, VISUALIZATION AND CONTROL Internet-capable with Process Monitoring System The Wallace & Tiernan Process Monitoring System consists of a data management device that is independent of the operating system and makes it possible to collect and visualize data of equipment and devices connected to the RS 485 bus. Four password-protected user levels control access to operational data via PC, laptop or Smartphone. Use universal standards with OPC OPC (OLE, Object Linking and Embedding, for Process Control) is a uniform, networked, Windows -based software standard for interaction in the area of process automation technologies. It allows complete data transfer across different levels (from field to control center level) and provides maximum flexibility and independence for the user. The Wallace & Tiernan OPC Server easily connects all RS 485 devices to Windows-based visualization systems. The interface supports bidirectional data flow, i.e., the OPC client can both read and write process data. WALLACE & TIERNAN PROCESS MONITORING SYSTEM Linking with higher-level controllers For the measurement and control systems DEPOLOX Pool E 700 P, DEPOLOX Pool and the devices of the SFC series Evoqua Water Technologies offers fieldbus converters to connect to the most prevalent fieldbus systems: Data exchange between various, manufacturer independent devices is thus possible using the standardized fieldbus systems Profibus DP, PROFINET IO, or Modbus TCP. BARGRAPH VIEW

TRADITION CONNECTS NEW NAME RELIES ON RENOWNED BRANDS Evoqua Water Technologies revives Wallace & Tiernan - the renowned global brand for water treatment and disinfection. The company history is especially evident in the technical rooms of many pools because the equipment is proven and durable. Evoqua continues this tradition with new products as well. You can rely on it. Auf der Weide 10, 89312 Günzburg, Germany +49 (8221) 904-0 www.evoqua.com Barrier, Chem-Ad, Chloratekt, DEPOLOX, OSEC, V10k and Wallace & Tiernan are trademarks of Evoqua, its subsidiaries or affiliates, in some countries. MODBUS is a trademark of Schneider Automation, Inc. PROFIBUS and PROFINET are trademarks of Profibus International. Windows is a trademark of Microsoft Corporation. All information presented herein is believed reliable and in accordance with accepted engineering practices. Evoqua makes no warranties as to the completeness of this information. Users are responsible for evaluating individual product suitability for specific applications. Evoqua assumes no liability whatsoever for any special, indirect or consequential damages arising from the sale, resale or misuse of its products. 2014 Evoqua Water Technologies GmbH Subject to change without notice WT.001.110.000.DE.BR.1214