INSTRUCTION MANUAL Auto Purge System

Similar documents
SVEA II GSM Connector User Manual

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual

NTF-230 OPERATION MANUAL

RAM 4021-DPX Operation Manual

AutoChanger Installation & User Guide Issue 2

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

D10S/D20S Wall/Post Mount Inflator Quick Start Manual

Operating Instructions Part No

Performa Cv Twin Alternating and High Flow Systems. Manual Supplement

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

accidents which arise due to non-observance of these instructions and the safety information herein.

200 PSI COMPRESSORS - MODEL NUMBERS

INSTRUCTION MANUAL. Thanks for purchasing our airbrush compressor and please read this

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

100C Air Compressor Kit

200 PSI FAST-FILL AIR SOURCE KIT

IMPORTANT SAFETY INSTRUCTIONS

Laboratory Mortar Mixer (Testing)

ECL Comfort 110, application 131 (valid as of software version 2.00)

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Stirring Water Bath. Instruction Manual

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

PURGEX X Purge Controller E Version. User s Manual

AIR COMPRESSOR 12 V DIRECT DRIVE MULTI-FUNCTION INSTRUCTION MANUAL. Model no

12V AIR STATION ALL-IN-ONE

INSTRUCTION MANUAL Pressure Relief Device LPT

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies

OPERATION MANUAL NTF-15

MODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

NGP-250/500 Nitrogen Generator Quick Start Guide

571 Series Medical TM. IntelliSwitch Electronic Switchover

G2W PRO ROBOT. User Manual. paddlepalace.com

RAM 4021 Operation Manual

NIV EAU MATIC ST User Manual Made in Canada

200 PSI HIGH-FLOW AIR SOURCE KIT

NTF-515. Operation Manual

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

User Manual GRI- 1500Li

Version-E E100930

PurgEx. X Purge Controller N Version. User s Manual

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

User Manual. Quantos Automated Dosing Liquid Module

Inert Air (N2) Systems Manual

444C DUAL PERFORMANCE VALUE PACK

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

COMPRESSOR AND INFLATOR WITH TORCH

Operation Instruction Manual

Bante820 Portable Dissolved Oxygen Meter Instruction Manual

400C & 450C DUAL PERFORMANCE VALUE PACKS

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

PORTABLE WORK LIGHT MODEL NO: CL6FS OPERATION INSTRUCTIONS PART NO: GC0315

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

STREAMLINE SHOP SERIES MODEL OPERATION & PARTS MANUAL

CCT-7320/ROC-2313 Reverse Osmosis Controller

OPERATION MANUAL NTF-60 Plus

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

Automatic Twin Greasing System

E Cube Lift Model: ECU Installation Instructions

OPERATION AND MAINTENANCE INSTRUCTION MANUAL

BY GREGGERSEN CATA LOG

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

MODEL NUMBER: AS18-2 USER GUIDE

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Operations Manual. Internal automatic Pressure control for orbital tube welding. By Exel Orbital Systems, Inc. Page

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

Glove Box Installation Manual

Fiber Cable Puller with Tuf-Lugger lite

MODEL 100 NITROGEN INFLATION CART

Dual Solenoid Gas Valve Installation

Inverse Prop. Pressure-Relief Cart., Size 2 4

CENTRAL GAS SUPPLY SYSTEMS : CYLINDER BATTERIES AND HIGH PRESSURE HOSES

Apollo Safety Features

PURGEX X Purge Controller D Version

DIRECTIONS FOR USE / ASSEMBLING

TWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

92831 TEL: (714) FAX:

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0250A4-T4-W4, ICE0400A3-T3-W3 MODEL - ICE0500A3-T3-W3-R4, ICE0606A3-T3-W3-R4 Includes 50Hz.

CARTRIDGE FILTERS. Models: CF50, CF75, CF100, CF150,

MP15 Jockey Pump Controller

IMPORTANT SAFETY INSTRUCTIONS

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

1. Functional description. Application program usage. 1.1 General. 1.2 Behavior on bus voltage loss and bus voltage. 1.

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

BUBBLER CONTROL SYSTEM

Operating instructions Electrical switching facility pco

KERN EG/EW Version /02

5 Channel Calibrator

Installation & Maintenance Manual. Economy Manifold

Transcription:

INSTRUCTION MANUAL Auto Purge System

content 1. Safety instructions 2. Description 3. Assembly and installation 4. Delivery items 5. Technical data 6. CE-Document 1. Safety instructions Read the safety instructions carefull to prevent possible danger and damage to the N²- System. 1. In case of using nitrogen the room has to be sufficient ventilated 2. The power supply should only be connected with the right type of socket or adapter. 3. Beware that the power supply cable doesn t get damaged as a result of been run over or otherwise be damaged. 4. Beware of influences of the surrounding area. Don t use the equipment in a moist or wet surrounding. 5. Don t over stress the equipment. Use the Auto-Flow-System only for the indicated voltage and pressure or pressure range. 6. Remove the plug from the socked before opening. 7. Don t connect dangerous gasses or solvents. 8. Avoid unappropiated use. 9. Make sure that the main switch is on off when the plug is connected with the outlet socket. 10. The screws used for the connection off the Auto-Flow-Systems may not be locked or adjusted.. 11. The signal cables may only be connected with door contact cables from Totech dry-cabinets Any changes made that are not listed in the safety instructions maunal as well as individual made changes, the warranty will void. The safety instructions and the mentioned precautions are to be read carefully and should be kept near the Auto-Flow-System. Ignoring safety instructions can cause accidents, injuries or health problems. The Totech Auto-Flow-System is in accordance with the EG conformation statements and the safety regulations. Should you have any questions about the use of our N²- System please contact us.

2. Description The Auto-Flow-System is developed to use as in combination with a Totech drying cabinet. The apparatus is used for the quick removal of moisture in the cabinet after the doors have been opened. The drying proces is realized by using recycled dried air of nitrogen (N²), which is add automatically after the doors have been closed. The amount of recycling can be selected by the user depends on the volume of the cabinet and the humidity factor Two parameters are available. The amount needed can be regulated with the valve (1) up to 100 l/min. The amount of air/nitrogen can be read out on the engaged flowmeter. The recycling time of the digital timer can be individually set within a time range between 0-99 minutes. The exchanged amount of air/nitrogen volume for each door is calculated by the amount in liter pro minute multiplied with the set amount. At the same time the Auto-Flow-System has a permanent recycling cycle independent on the opening of the door. Using the Standby-flow valve (2) this feature can be set and read out. To compensate pressure differences the apparatus is equipt with ist own regulator. 4 3 1 2 6 5

The apparatus is equipt with an alarm buzzer which will be activated if the door is opened for more than 1 minute (60 seconds). If the door is closed the alarm will be disactivated. 3. Assembly and installation The assembly of the apparatus is only to be realized on the right side of the cabinet. On the right side of the cabinet are two holes with a diameter of 16 mm. Remove the nuts and washers from the apparatus (5). Mount the apparatus on the cabinet. The signal cable (6) has to be connected with the doorcontact cable. The air/nitrogen connection can be made by connecting a pressuretube on the nippel located on the backside of the Auto-Flow-System. After that the airpressure of dry oilfree air or nitrogen with a maximum of 600kPa (6 bar) can be exicuted. Warning: in case of using nitrogen you have to make sure that sufficient ventilation is available. Make sure that the voltage is in accordance with the given voltage indicated on the apparatus and the main swith (4) is switched off. In case of the right voltage the apparatus can be connected with the power-supply. Swith the apparatus on with the switch (4). After the apparatus is swithed on, a test is automatically executed. The indicator in the switch will be turned on and shows that the apparatus is ready for use (Flashing shows that the system is in recycling mode and the preset time is running). Is the timer (3) set for 00, the recycling mode is deactivated. By setting the codeswitch with the + and - pushbuttens the desired recycling time can be realized up till 99 minutes. After the doors have been closed the preset value of the amount of air is activated for the set time of the timer (3). This will be indicated by flashing of the signal light located in the switch. Opening of the doors will stop the systems functions and the preset time is restored. After the door has been closed the proces starts again. As a result that Nitrogen is responsable for the continuously driving out of oxigen, the system is equipt with a standby-flow function. The permanent recycling with low volume is started supplementary with the automatic recycling after opening the door. The permanent amount of nitrogen can be set and read out with the right flowmeter (2). In case that this option won t be used the option can be switched of.

4. Delivery items - Auto-Flow apparatus - Manual - Power cable 5. Technical data Voltage: 90 240 VAC N² connection: 8 mm hose connection N² connection pressure: 1 6 bar N² Standby- quantity: 0 25 L/min N² (Purge): 0 100 L/min (Purge-Time): 0 99 min 6. CE-document With this document we confirm: Totech Europe BV Linge 28 8252 PJ Dronten Auto Purge System is conform with the safety- and health regulations by EG-directives as mentioned below: EN55011: 1998+A1:1999+A2:2002 EN61000-6-2:2001 2006/95/EG 2004/108/EG Totech Europe B.V. Gerhard Kurpiela, Technical Manager