acculink platinum zv zoning system

Similar documents
HAP e-help. Obtaining Consistent Results Using HAP and the ASHRAE 62MZ Ventilation Rate Procedure Spreadsheet. Introduction

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) MECH-1-A

Evaporator (DX) Freon Applications 1 12 Tons MHF

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

HCD HIGH CAPACITY DRUM LOUVER

Outside Air Nonresidential HVAC Stakeholder Meeting #2 California Statewide Utility Codes and Standards Program

CLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE

SECTION TESTING ADJUSTING AND BALANCING FOR HVAC

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

VAV SYSTEM INDOOR AIR QUALITY CONSIDERATIONS FOR OFFICE SPACES

RICK FAUSEL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Sampling Equipment Catalog. MicroPurge Low-Flow Pump Control

SECTION 11 VACUUM GRIPPER

HumiSys HF High Flow RH Generator

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

DESIGN OF AN EFFECTIVE LOW PRESSURE VAV AIR DISTRIBUTION SYSTEM

LENNOX SLP98UHV DIAGNOSTIC CODES

ENVIRONMENTAL CONTROL SYSTEM (ECS)

DANGER WARNING IMPORTANT

APPLYING VARIABLE SPEED PRESSURE LIMITING CONTROL DRIVER FIRE PUMPS. SEC Project No

6. EXPERIMENTAL METHOD. A primary result of the current research effort is the design of an experimental

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

AE R1 February 2015

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

CO 2. (R744) Service Station Presentation. Contents. Goals Basic functions Specification Recovery R477 Vacuum Charge Safety Other features Prototype

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

REQUIREMENTS AND HAND-OVER DOCUMENTATION FOR ENERGY-OPTIMAL DEMAND-CONTROLLED VENTILATION

The Advancement of Pressure Independent Technology

P14 Series Pressure Actuated Mechanical Sequencer

INTERPRETATION IC OF ANSI/ASHRAE STANDARD VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

Tradition & Technology

Mooney * Noise Controller Installation, Operation, and Maintenance Manual

Discharge Relief Valve Operation & Maint.

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

Operator: Save these instructions for future use!

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

OC Panel High Limit Aquastat Kit, Manual Reset p/n

DeZURIK. KSV Knife Gate Valve. Safety Manual

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Excellent Duct Systems Require Design, Not Guesswork!

WARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only

Powers Controls D Day-Night Thermostats

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

INSTALLATION INSTRUCTIONS FOR SSI WIDEBAND DIFFUSER

Natural Gas to L.P. Gas Conversion Kit

Model PSI Compressor with 3-Gallon Air Tank 12VDC

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

- From 2005 year model, replacing with RM250 with 2-stroke engine, RM-Z450 with 4-stroke engine was introduced in the market. - From 2008 year model,

36H SERIES Combination Gas Valve

Let s examine the evolution and application of some of the more popular types. Cascading Pressure Type

GM Series Dual-Block Multi-Function Gas Control Valves

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

MRO Oil-Air Ratio Regulator

INSTALLATION & OPERATION MANUAL. Dual Duct VAV Terminals. Redefine your comfort zone.

ACV-10 Automatic Control Valve

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S

BACK PRESSURE / SUSTAINING

G96 Series BASOTROL Dual Operator Valve

Barcol-Air BRM Radiant Module

V48 Series 3-Way Pressure-Actuated Water-Regulating Valves With Union Fittings

Leak-Free Load-Control Valve SAE ½ psi flange

DOMESTIC HOT WATER TEMPERATURE CONTROL with SAFEGUARD

Natural Gas to L.P. Gas Conversion Kit

BACK PRESSURE / SUSTAINING

TECHNICAL DATA. Q = C v P S

STRUCTURE S-65 PURPOSE SPILLWAY OPERATION

SINGLE VALVE WITH LOW-FLOW BYPASS

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

BUBBLER CONTROL SYSTEM

Type 3 - PSA Nitrogen Generation System

Genie Supreme Model 123 Installation & Operation Instructions

Data Sheet Issue A

Preparation and Installation of the Sanitary BDI-FLX Sensor and Connection to the BDI-FLX Interface Cable

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

TECHNICAL DATA. Q = C v P S

AC : A LABORATORY EXERCISE TO DEMONSTRATE HOW TO EXPERIMENTALLY DETERMINE THE OPERATING POINT FOR A FAN

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

Autocalibration Systems For In Situ Oxygen Analyzers

R E D I C O N T R O L S

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

AIR CONDITIONING AND PRESSURIZATION CONTROLS AND INDICATORS

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

/ /

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

NGP-250/500 Nitrogen Generator Quick Start Guide

Operator: Save these instructions for future use!

TECHNICAL DATA. Q = C v P S

Chilled beam iq Star WEGA II

Measuring range Δp (span = 100%) Pa

G92 Series BASOTROL Automatic Pilot Gas Valve

Genie Supreme TM Model 123HP Installation & Operation Instructions

Transcription:

acculink platinum zv zoning system Components: AZONE950AC52ZA ZZONEPNLAC52ZA AZONE940 ZZONEEZPAC52ZB Platinum 950 Control Zone Panel Kit up to 4 zones Included: Discharge Air Temp sensor Static Pressure Transducer Transducer enclose 2- Static pressure Probes Clear tubing 8ft Zone Sensor with display (wired) Zone Expander 5-8 Zones Zone Dampers Up to 4 dampers per zone 24 VAC Modulating Available in Round, Retro-Fit Round & Rectangular Bottom or Side mount NOTE: Actuator is always located on the second dimension of the model # Example: ZDAMPSMMA42A will have the actuator mounted on the 2 side Three wire connection-8 gauge.5va damper actuator with 60 second travel time 8 in lbs of torque Manual gear release Screw terminal blocks 97-98% Leak proof rating See Quick Reference Guide for available sizes

thermal zones on a single equipment zone system (i.e. Don t apply zoning to a group of rooms or zones requiring simultaneous cooling and heating from a single non-multi zoned equipment system.) 2. A room-by-room and a zone-by-zone heating and cooling load calculation is required in order to determine the quantity of conditioned air necessary for each room and each zone as well as to size equipment. Use ACCA s Manual J or an equivalent procedure to determine equipment sizing and room (zone) airflow quantities. ACCA Manual J 8th Edition Version 2.00 provides two separate load calculations to assist with zoning design: a) The average block load condition is used to size the HVAC system. b) The hourly peak load condition is used to design the branch duct system in zoning applications. Since the load conditions change throughout the day, the branch duct system must be sized large enough handle and absorb peak load conditions. The duct dampers will reduce air flow during reduced load conditions. 3. Do not oversize equipment. Equipment sensible and latent capacities should meet at least 95% of the load calculation requirements at the design conditions. ACCA s Manual J 8th Edition Version 2.00 and J8AE version.00 in Section0-4 recommends matching the calculated load values by ±5%. Oversized equipment compounds the excess air dilemma and increases the complexity of maintaining equipment control as well as comfort control. The equipment selection should match the heat load calculation as closely as possible. Multi capacity and variable speed equipment is recommended since the system modulates to better meet the needs of the individual calling zones and minimize excess air. 4. When possible, utilize equipment with airflow and BTUH capacity control. Staged equipment affords a major reduction in delivered airflow and equipment BTUH on lower stage(s) while at reduced loads. These reductions are designed into the equipment by the manufacturer and may decrease the excess air and the need for additional control methods while increasing the design and system flexibility. Using staged equipment with airflow and capacity reductions designed into the equipment by the manufacturer simplifies the excess air control dilemma. 5. Zone size and the number of zones are dependent and contingent on the home floor plan layout, number of stories, equipment capacity, airflow control and the type of

heating equipment. All zones should also be fairly equal in size to minimize excess air issues (any zone sized less than 25% will be automatically set as a non-voting zone). Please refer to Table - recommended maximum number of zones in the Excess Air section of this document. 6. Damper placement should be as far away as possible from the supply outlets to minimize noise and improve the air pattern. Dampers generate turbulence and noise when throttled. 7. Supply Diffuser / Registers should be selected at 60 to 70% of design airflow when using fully modulating dampers. The supply diffusers / registers need to be selected and optimized for mid-range performance. The majority of operational time will require 45 to 75% of the Manual J design CFM maximum. The limited time at minimum or maximum airflow requirements must be analyzed but should not over ride the mid-range operational requirements. The manufacturers data should be analyzed to assure the registers will provide sufficient throw, performance and room mixing at 40% to 50% airflow, while noise levels and drafts should be verified at design requirements of 00%. 8. Return Duct requirements: One or more returns per zone are required for optimum results. When one return per zone is not possible, the return air travel path from other zones should not pass near another zone s thermostat (or sensor). The return air path can influence sensing capabilities within the zone. Remember that there must be sufficient return air capability or flow through the zone and near the zone thermostat / sensor to allow the thermostat / sensor to adequately sense the zone conditions. caution Exceeding the equpment design limitations may force the safety limits to cycle during normal run cycles, thus causing equipment damage and potential loss of operation. C. Excess Air Management. Platinum ZV zoning manages excess air without the need for a bypass damper or position stops in the supply dampers. The first method of managing excess air is to eliminate or greatly reduce the excess. a) Equipment Stage Control

) On equipment with multi-stage capacity the 950 control will only deliver the stage of capacity that the calling zones can manage. The sum of the calling zones sizes must be greater than the current stage before allowing the system to stage up. b) Air Flow Reduction ) For cooling or compressor heating applications the air flow can be reduced by up to 30%. This air flow reduction does not apply to gas/oil heat or during electric heat operation.if the Platinum ZV control still calculates excess air, then the excess air will be managed via the relief strategy. c) Relief Strategy Note: The minimum damper position during relief and normal operation is 25% open Strategy Manage excess air though the calling zones by delivering more capacity than the zones are currently requesting Strategy 2 Once all calling zones dampers are 00% open and excess air remains, the excess will be delivered evenly to the zones that are in the same calling mode but have no demand Strategy 3 Once all calling zone dampers are 00% open and all non-calling same mode zone dampers are 00%, and excess air remains, the excess will be deliv ered evenly to the zones which are in the opposite mode of operation Reference Table for recommended maximum number of zones based on system type. Platinum ZV zoning relief strategy is effective in managing excess air when implemented on a properly applied system. Below is a short list of issues which can cause the relief strategy to over condition the non-calling zones: a) Zone sizes are disproportionate (large and small zones in the same system) b) Too many zones for the applied system (installed system lacks staging or air flow reduction capabilities) c) Branch duct system is not sized to handle expected load conditions in heating and cooling mode.

Listed below are the recommended limitations for number of zones Table Recommended Maximum Number of Zones Based on System Type Outdor UnitType Compressor Stages Heating type Heating Stages Maximum Zones gas heat 2 4 gas heat modulating 6 none electric heat all stages 4 oil heat 3 hot water 8 4 2 none 8 variable 8 2 variable electric all stages 4 2 4 2 modulating 6 natural / LP variable 2 4 variable moduilating 6 4 2 hot water 8 variable 8 3 oil 2 3 For more explanation of the Platinum ZV zoning system please reference publication CNT-APM00-EN - Zoning Application Manual CNT-APG004-EN Page 5 May 203