OPERATION. Thank You. General Operation. Lowering the Lift. Raising the Lift. Safety Tips

Similar documents
BY HYDROHOIST BOATLIFTS

BY HYDROHOIST BOATLIFTS

Installation and service should be performed by a qualified service professional.

LOGO TO COME PLEASE PROVIDE. Ballast & Tower. Operator s Manual

[ ] 10 YEAR HULL WARRANTY [ ] GEL COAT: [ ] RESIN: [ ] FIBERGLASS [ ] VACUUM BAGGING:

Endo-Flush Order # ZUTR30004 OPERATION MANUAL. Zutron Medical, LLC W 98 th St #40-27 Lenexa, KS Phone Fax

Model PSI Compressor with 3-Gallon Air Tank 12VDC

S/Y MORSKI ZEKAN TECHNICAL INFORMATION

444C DUAL PERFORMANCE VALUE PACK

CONTENTS AIRBERTH OWNER S MANUAL I 3

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

BS2000 MOTOR ELECTRONICS, INC. PROTECTION INSTRUCTION MANUAL. (407) Phone: Website:

Transom. Stern. Starboard side. Stem between planing and displacement hulls. Sample. page

OIL IN NAVIGABLE WATERS REGULATIONS [L.N. 101 of 1968.] under sections 5 and 7. [22nd April, 1968] [Comrnencernent.]

400C & 450C DUAL PERFORMANCE VALUE PACKS

Manual Leveling Control Installation/Operation

CLIENT NAME: LOCATION: CALM BUOY INSPECTION:

GETZ EQUIPMENT INNOVATORS PART NO.: 9G59554 MODEL: MS 36 SC-R HYDROSTATIC TEST PUMP

R E D I C O N T R O L S

SP-110 Autopilot OPERATION

Chapter 2. Before You Get Underway. Copyright Coast Guard Auxiliary Association, Inc.

24L OIL FREE AIR COMPRESSOR MODEL NO: TIGER 7/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS10/13

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

This document to be used with Hurley traditional Davits

VERTICAL AIR COMPRESSORS

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

There is an Adobe PDF file available, detailing the HP Nissan Outboard Motor.

Miss Joy Boat Manual

The following is a walk-around that should be done on each day of use before starting the airboat.

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

VERTICAL AIR COMPRESSORS

License to Keel Boat Manual

SAILTEC, INC CONGER COURT, OSHKOSH, WI USA

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Instruction sheet for Hydraulic Cylinder

Air Tractor Preventative Maintenance Manual And Troubleshooting

ASSIGNMENT 3. Textbook Assignment: Water System, Trim and Drain System, Air Systems, and Main Hydraulic System Chapters 9-12.

5.0 INSPECTING, FILLING AND LABELING SMALL CYLINDERS

Installation, Operating, Maintenance and Safety Instructions for. Pressurised water systems for boats

COMPRESSOR MANUAL. (888)

Fishing Vessel Stability

Siting and Installation Manual

OPERATION AND MAINTENANCE MANUAL

Tire Inflation Cage Kit For servicing only single piece automotive, and most light truck tire/wheel assemblies

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Progression 24LD Stern Drive

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

DURAS INFLATABLE BOAT OWNER'S MANUAL

Budget Range Operators Handbook

MODEL 840 AIR HYDRAULIC PUMP INSTRUCTION

100L AIR COMPRESSOR MODEL NO: TIGER 16/1010 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Welcome aboard, here are some of the basics and FAQs you ll want to know in Operating.

Installation of Your SprayMaster System

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

HYDRAULIC CYLINDER TEST

2,500/4,000 LB Easy Riser Vertical Cable Feighner Lift

HPICAL Operation & Data Logging Procedures. Click spacebar to advance through slides 1

accidents which arise due to non-observance of these instructions and the safety information herein.

THE VORTEX SLIDE OWNER S MANUAL

TECHNICAL DATA. Q = C v P S

USER S INFORMATION MANUAL

AMS SUPER SILENT COMPRESSOR USER & MAINTENANCE GUIDE

National Marine Manufacturers Association

PRESSURE ADJUSTMENT Main pressure adjustment

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Armfield Distillation Column Operation Guidelines

Underwater Housing for Canon EOS M

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

INSTALLATION, OPERATION AND SERVICE MANUAL ABS AIR BAG LIFT

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

Livewell/Baitwell Pumps. Livewell/Aerator

24L AIR COMPRESSOR MODEL NO: TIGER 11/250 PART NO: OPERATION & MAINTENANCE INSTRUCTIONS LS01/13

Sunrise Fountain Water Wonders Assembly & Mounting Instructions

OPERATION INSTRUCTIONS Form 6899-TE, Four-Post Lift Rack. MODELS L451 and L454 (all model variations) Copyright 2014 Hunter Engineering Company

Mooredale Sailing Club 351 Queen St. E P.O. Box Toronto, ON M5A 1Y8. MSC Motorboat User Guide

NORTH RIVER OUTBOARD BOAT MODELS MAINTENANCE AND OPERATION

Miss Joy Boat Manual

CORPORATE HEADQUARTERS WESTERN SALES AND MANUFACTURING PLANT P.O.

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Discharge Relief Valve Operation & Maint.

Sterisil Ac+ Installation & Operating Manual

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

COMPRESSOR OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: WARRIOR 55 PART NO: (110V) , (230V) , LS0512

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

System Pressure Manager Standard & System Pressure Manager Plus

Glove Box Installation Manual

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Halsey Taylor Owners Manual STOP!

SPECIFICATIONS TABLE Maximum Air Pressure 115 PSI Air Tank Capacity 20 Gallons

COBIA 201 CC WELCOME. O w n e r s M a n u a l

9BCPD24/9BCPD36-TFH BUBBLE TUBE PODIUM INSTRUCTIONS 2017

03/07/2014 V

Lab #1 Pressure: Bubblers and Water Balloons CEE 331 Fall 2003

GETZ EQUIPMENT INNOVATORS PART No. 4G59678 CARBON DIOXIDE MINI PUMP FOR EXTINGUISHER SERVICE (Revised )

200 PSI COMPRESSORS - MODEL NUMBERS

Hammar LifeJacket Inflator

Transcription:

Thank You OPERATION We would like to a moment to thank you for purchasing a HarborHoist TM G1.5 lift. We believe our lifts are the easiest to use on the market today, and know that your new lift will give you many years of trouble free service. The following pages will provide you the necessary information for maintaining your new lift, as well as instructions on it s use. Your new HarborHoist TM G1.5 lift is the result of extensive research, design and development in environments where corrosion, marine growth, and severe weather encourage lifting boats out of the water to help protect your investment. As the leader in the industry, the HarborHoist TM G1.5 lift offers features provided exclusively by HydroHoist Marine Group. General Operation Familiarize yourself with the Control Box. We have created a simple to use 3 BUTTON user interface, consisting of a raise, stop, and lower button, and simple power indicator led. These are the basic components for the operating the HarborHoist TM G1.5 lift. Internal to the Control are state of the art valve controls and circuitry that will insure that your lift comes up level each and every time you lift your boat from the water. Lowering the Lift 1) Make sure the Power LED is illuminated 2) Press the lower button. This will open the valves. 3) Allow the lift to submerge (Walkways will remain above water) 4) Untie lift safety lines from boat 5) Everyone may board the boat after the boat clears the lift Raising the Lift 1) Float boat into established pick up position on lift 2) Tie off safety lines to the boat 3) Everyone must exit the boat before lifting. 4) Press raise button 5) Once the lift is fully raised, air bubbles will be visible exiting from all tanks. 6) Press Stop on Control 7) If the lift needs to be leveled once it is in the raised position, press the yellow level button and the lift will automatically level to lift. Safety Tips Test GFI on a monthly basis Keep Children away Do not overload the lift. Do not allow yourself to be distracted or walk away from the lift during operation.

Safety Tips Cont d Make sure bilge pump is set for automatic or remove the drain plug while lifted. Significant water accumulation in the bilge may overload the lift. Make sure any ballast tanks are empty before lifting the boat. Lift is not designed for lifting people. No persons should be under the boat while it is in the suspended position. Weight must be distributed equally side to side and bow to stern before lifting, Otherwise the boat will not center properly and appear to be crooked on the lift. TEST RESET INDICATOR LIGHT

INITIAL CONTROL SET-UP PRIOR TO LIFT OPERATION AND/OR ATTEMPTING TO LOAD A BOAT: STEP 1: Determine the control position of the boat: Starboard or Port A: While facing the control if the front of the boat is to the right, it is Starboard. B: While facing the control if the front of the boat is to the left, it is Port. STEP 2: Program the control in relation to boat placement A: For a Starboard control placement: press STOP and UP at the same time until the Starboard LED lights. For a Port control placement: press STOP and DOWN at the same time until the Port LED lights. B: When the corresponding LED light (starboard/port) remains on, the control is set. C: PRECAUTIONARY NOTE: If the valves actuate (open), press STOP and begin again. STEP 3: Program the control level A: Press the UP button; this will raise the lift to its highest point. B: Each tank must be bubbling from the relief hole before hitting STOP. If a tank does not bubble out hit STOP and zero the control. -To zero the control, push and hold the UP and DOWN buttons at the same time until the 5 valve LED s flash. -Press UP, and allow additional time for all tanks to bubble from the relief holes; only then press STOP. -To zero the control, push and hold the UP and DOWN buttons at the same time until the 5 valve LED s flash. C: Your lift is now set and ready to use.

Preventative Maintenance Because of the harsh environments in which the HarborHoist TM G1.5 can be installed, it is very important to inspect your HarborHoist TM occasionally to ensure it is at peak performance. On a monthly basis inspect the following: 1) GFI trips and resets properly when the TEST and RESET buttons are pressed. 2) All air hoses are firmly attached and there are no apparent leaks present. 3) All the aluminum components are structurally sound and no heavy corrosion is visible. 4) The wood hull pads are structurally sound with no severe cracking. 5) All mounting / attachment brackets are secure. 6) If rope mooring is used, inspect the ropes for any issues that may compromise there integrity. Most importantly, run your blower fan at least once a month even during the off season. Press the Raise button on the control and let it run about a minute to help keep the motor contacts and brushes clean. 800.825.3379 boatlift.com 915 West Blue Starr Drive Claremore, OK 74017