Installation/Care/Use Manual

Similar documents
INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

Installation and Use Manual

Owners Manual. Models 4420BF1U & 4420BF1L Floor Mounted Bi-Level Bottle Filler Tubular Fountain

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

Halsey Taylor Owners Manual

Halsey Taylor Owners Manual

PAGE (Rev. A - 06/17)

Owners Manual Models 4430BF3, 4430BF2 & 4430BF1 Floor Mounted Tri-Level Bottle Filling Tubular Fountain

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Pressure Independent Control Series

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTALLATION AND OPERATION MANUAL CHEMICAL BYPASS FEEDER General Instructions Regarding All Models

Installation, Operation and Maintenance Manual for Back Pressure Regulator

GILMONT ACCUCAL FLOWMETERS

Installation, Operation, and Maintenance Manual

LK4420BFFR - FTN, 4420BFFR - FTN. Owners Manual

Medical Gas Control Panel

INSTALLATION and OPERATION INSTRUCTIONS

Bermad Model:

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Operation Manual Air Saver Unit ASV5000 Series

O&M Receiving and Inspection. Storage of Water Treatment Media

Shut-Off Valves and Valve Boxes

BUTTERFLY VALVES Series 800

CO2 Tank Conversion Kit P.N , P.N , and P.N

Installation Instructions

Installation, Operation & Maintenance Manual for Flo-Max Coupler Bracket Model FM150

Dual Solenoid Gas Valve Installation

Installing ASI Umbilical Delivery Systems

INSTRUCTION MANUAL. January 23, 2003, Revision 0

Constant Pressure Crude Oil Container Model CPCCP

ASSE International Product (Seal) Listing Program

ROTATING DISK VALVES INSTALLATION AND MAINTENANCE 1. SCOPE 3 2. INFORMATION ON USAGE 3 3. VALVE TYPES 3 4. OPERATORS 5 5. VALVE CONSTRUCTION 6

REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL

Air Intake Snorkel Kit

LEAK TROUBLESHOOTING

Installation, Operation, and Maintenance Manual

Assembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Operation Manual. PEGAS NovoTap, PEGAS NovoTap+

BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS

Pressure Dump Valve Service Kit for Series 3000 Units

INSTALLATION INSTRUCTIONS

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

AcornVac Vacuum Plumbing Systems - Trouble Shooting Guide

PP-1, PP-1W, PP-2, & PP-3

Tridak Model 1060 User Guide. Syringe Filling System

Installation Instructions

SUMMITTM 400 & 600. Natural Gas Barbecues. Step-By-Step Guide

Gas Lines. Technical Manual. Sumitomo (SHI) Cryogenics of America, Inc Vultee Street Allentown, PA U.S.A.

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Installation, Operation, and Maintenance Manual

INSTALLATION INSTRUCTIONS

Installation Operating Instructions for Simple Duplex Manual Manifolds PX-TSD Series

Bulletin /06/2012 Supersedes 10/23/00. Installation of John Crane Type 73 Inflatable Mechanical Seal. Page 01 of 10

GM-7000 Series CE Approved Gas Control Valve

KENNEDY VALVE OPERATION & MAINTENANCE MANUAL

BPB26-1 AND SSPB26-1 PATIO BASE INSTALLATION INSTRUCTIONS

TECHNICAL DATA. Page 1 of 12

HIGH RATE BASKET STRAINER

VAPOMATIC ANESTHETIC VAPORIZER

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

INSTALLATION GUIDELINES

Inert Air (N2) Systems Manual

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

INSTALLATION INSTRUCTIONS

OPERATION MANUAL Please read this Operation Manual carefully before use, and file for future reference.

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

TECHNICAL DATA. Trimpac 244a. September 16, 2013

NGP-250/500 Nitrogen Generator Quick Start Guide

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation Troubleshooting Maintenance Instructions Installation / Start-up

Installation Instructions

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Float Operated Level Controllers

VB-7211 Series. Application. Features. Applicable Literature. 1/2" to 1-1/4" Union End NPT Stem Up Open, Two-Way Valves General Instructions

Anti-flood device Model B-1

INSTALLATION AND OPERATION INSTRUCTIONS

Model: 43T. Bermad Pressure Relief Valve

PRODUCT SERIES: A-SF-3000BD

VB-7323 Series. Application. Features. Applicable Literature. 1/2 to 2 Screwed NPT Three-Way Diverting Valves General Instructions

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

Carter Option X Valve connector assembly. Maintenance manual

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

High Pressure Inlet Kits for CONCOA BlendMites and BlendMasters

310 SERIES TILT-TO-LOAD ROTATOR. The Specialist In Drum Handling Equipment

PEDESTAL MOUNTED EMERGENCY EYE & EYE/FACE WASH

AKIT1901LM (Metal levers) AKIT1901XM (Cross Handles)

SERVICE MANUAL SALAMANDER BROILERS RADIANT AND INFRARED 36RB 36IRB VULCAN C36RB C36IRB WOLF

KERSPLASH POOL CLIMBING WALL INSTALLATION INSTRUCTIONS

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

Transcription:

Installation/Care/Use Manual EMASM Surface Mount Bottle Filling Station IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL. TOOLS/ITEMS REQUIRED BUT NOT SUPPLIED - SERVICE STOP VALVE WITH 3/8" COMPRESSION OUTLET - FASTENERS FOR WALL TYPE (5 REQ D.) - SLIP JOINT DRAIN UNION OR COMPRESSION CLAMP - 5/32" HEX-WRENCH Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH ALL PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. FOLLOW ALL WARNINGS AND CAUTIONS CAREFULLY. After installation, leave these instructions with the customer for future reference. Warnings 1. Use with clean, clear, fresh potable drinking water only! Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before the system. 2. These products are designed to operate on 20 to 105 psig supply line pressure. If inlet pressure is above 105 psig, a pressure regulator must be installed in supply line. Any damage caused by reason of connecting this product to supply line pressure lower than 20 psig or higher than 105 psig is not covered by warranty. Page 1

ROUGH-IN EMASM ADA STAND ALONE STAND ALONE IMPORTANT! INSTALLATION NOTES: Ensure wall is structurally sound to bear the loads imparted by the Surface Mount Bottle Filler. /16 X 3/4 11mm X 19mm OBROUND HOLE (6) "C" 18mm 18mm 3/8 8mm O (6) BOLT 22 559mm FILTER USED ONLY IN LMASMB UNITS 6 1/4 159mm 3/8" 9.5mm WATER INLET 3 "A" 6mm 1-1/4" 31.mm DRAIN "B" 6 152mm MINIMUM CLEARANCE 64 3/8 1635mm 40 1/2 1029mm 45 5/8 44 1159mm 1118mm 48 1219mm 46 1/2 1182mm 42 1/8 1069mm OF BUTTON 38 1/2 9mm 2 686mm 4 102mm ADA DEPTH LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION ; 1/2" IPS MAXIMUM PIPE SIZE. SERVICE STOP VALVE NOT FURNISHED. B = RECOMMENDED WASTE LOCATION. WASTE SHOWN IN WALL BUT MAY BE BEHIND WALL. OUTLET 1-1/4 O.D. (TRAP NOT FURNISHED) C =/16" X 3/4" OBROUND HOLES FOR FASTENING BACKPLATE TO WALL. FIG. 1 OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN IN TUBE IS SECURED PUSH IN COLLET TUBE TO ATTACH IN IN POSITION TO RELEASE TUBE A B C PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE FIG. 3 Page 2

ROUGH-IN EMASM ADA ABOVE COOLER STAND ALONE IMPORTANT! INSTALLATION NOTES: Ensure wall is structurally sound to bear the loads imparted by the Surface Mount Bottle Filler. /16 X 3/4 11mm X 19mm OBROUND HOLE (6) "C" 18mm 1 /8 454mm 18mm 3/8 8mm O (6) BOLT 25 /8 22 658mm 559mm FILTER USED ONLY IN LMASMB UNITS 6 1/4 159mm 3/8" 9.5mm WATER INLET "A" 3 6mm 1-1/4" 6 31.mm 152mm DRAIN MINIMUM "B" CLEARANCE 64 3/8 1634mm 40 1/2 1029mm 45 5/8 1159mm 44 1118mm 48 1219mm 46 1/2 1182mm 42 1/8 1069mm OF BUTTON 38 1/2 9mm 2 686mm ADA HEIGHT WATER COOLER 4 102mm ADA DEPTH LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION ; 1/2" IPS MAXIMUM PIPE SIZE. SERVICE STOP VALVE NOT FURNISHED. B = RECOMMENDED WASTE LOCATION. WASTE SHOWN IN WALL BUT MAY BE BEHIND WALL. OUTLET 1-1/4 O.D. (TRAP NOT FURNISHED) C =/16" X 3/4" OBROUND HOLES FOR FASTENING BACKPLATE TO WALL. FIG. 2 Page 3

INSTALLATION INSTRUCTIONS Pre-Installation (reference Rough-In, Fig. 1 and Fig. 2) 1. Ensure Wall is structurally sound to bear the loads imparted by the EMASM Bottle Filler (On-Wall Bottle Filler). If necessary, install a Wall Support Carrier (not supplied). 2. Ensure Water Supply Line and Drain Line are sized and located as specified the Rough-in diagram. 3. Attach Service Stop Valve (not supplied) to Water Supply line orienting the 3/8"O.D. female compression outlet horizontally to the left. Purge water line and test for leakage. Correct any leakage. 4. Ensure package contains the following components: TOP SCREWS TOP COVER INSULATED WATERLINE OUTER WRAPPER DISPENSING NOZZLE ALCOVE DRAIN TRAY BACK PANEL BOTTOM COVER INSTALLER TO SUPPLY: SHUT OFF VALVE BOTTOM SCREWS FRONT VIEW REAR VIEW EMASM UNIT SHOWN Wall Mounting (reference Rough-In, Fig. 1) 1. Remove Top Cover from Bottle Filler by removing two (2) screws from top of unit. Use a 5/32" hex wrench (not supplied). 2. Remove Bottom Cover from Bottle Filler by removing two (2) screws from bottom of unit. Use a 5/32" hex wrench (not supplied). 3. With the Top and Bottom Covers removed, the Back panel is now free to be removed from Bottle Filler. 4. Fasten Back Panel to structurally secure wall through five /16" obround holes with fasteners appropriate for wall type. Locate Back Panel as specified in Rough-In. If necessary, attach to Wall Support Carrier (not supplied). 5. Ensure Back Panel is not obstructed by the roughed-in Water and Drain Lines. If Back Panel is prevented from seating properly, reposition Water and/or Drain Lines slightly until the Bottom Cover fits easily. 6. Before hanging the On-Wall Bottle Filler, ensure the Insulated Waterline is routed inside of the Wrapper If outside the Wrapper, reposition to inside or else the unit cannot be installed properly.. Hang the Bottle Filler onto the Back Panel, aligning two tabs into the top of the Back Panel. 8. Secure Bottle Filler to Back Panel by replacing Top Cover on top of unit and fastening with two (2) supplied screws. 9. Replace the Bottom Cover on bottom of the unit and fasten in place with two (2) supplied screws. Page 4

Plumbing Connections Ensure lines and ports remain clean and free of contaminants during assembly. Purge each component if necessary. To ensure quick-connect connections seal properly, follow instructions per Figure 2. Connect Plumbing Lines 1. Connect water supply line to unit: 2. Connect the 3/8"O.D. Copper tube from the in-line strainer to the 3/8" to the Service Stop Valve. 3. Connect the 1-1/4"O.D. Drain Tray Outlet to the in-wall Drain Line using a Slip Joint Drain Union or compression clamp (not supplied). Tighten all connections water tight. 4. Turn water supply on, inspect for leaks and correct any leaks before continuing. Instruction for Use 1. Place container under the dispenser nozzle and depress the actuator button. Hold until container is filled to the level desired. 2. To stop water flow, release actuator button. Pull container away from dispenser nozzle. REPLACEMENT PARTS PART NO. 100000163 98546C DESCRIPTION 1.0 GPM REGULATOR KIT- EMASM AERATOR KIT REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 PRINTED IN U.S.A. FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK, IL 60523 630.54.8484 Page 5