Hip Air Operated Valves

Similar documents
Index 7.1. Page R2 12/99

Index 7.1. Page R2 12/99

General Information valve design valve selector guide catalog numbering system warranty terms

High Pressure Equipment Taper Seal Valves, Fittings and Tubing

Air Operated Hydraulic Pumping Systems to 50,000 psi

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Specialty Products. Specialty Products Index

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

High Pressure Equipment Pressure Vessels and Reactors Index

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

Go to Table of Contents. Ball and Plug Valves

Ball Valves Subsea Series

High Pressure Equipment 2 - Medium Pressure Valves, Fittings and Tubing 20,000 psi service

Precision and Instrument Regulators 1/4" port size

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Chlorinator. MODEL C-731 (Floor Mounted)

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

PRO-50 Instrument Supply Regulator

Control Valve : The Final Control Element. Nimish Shah

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

Choosing the right miniature instrument and control valve is a snap

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

CASH VALVE TYPE KP BACK PRESSURE VALVES

Model 1800 PFM Series Regulator. Technical Bulletin

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and 8900

THE BP-690 SERIES. Operating and Service Manual. Series includes all variants of BP-LF/MF-690/691

V43 Pressure Actuated Water Regulating Valve

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

Installation, Operation and Maintenance Manual for Back Pressure Regulator

MANUAL BE SERIES Test Benches

High Pressure Check Valves

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Pressure Sensing Valve - Model 4023

MEGR-1627 Instruction Manual

Safety Blocks Brochure

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

Buying more than 11 gauges? Call Lesman for additional discounts.

Valve Proving System VDK 200 A S02

Pneumatic Powered - Plunger Pumps

Valve Proving System VDK 200 A S06*

SINGLE VALVE WITH LOW-FLOW BYPASS

PVQ 13 A2 R SE 1 S 20 C-11 D

MEGR-1912 Instruction Manual

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Description Advanced Features Typical Applications

1800CPB2 Service Regulators

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

Total Pressure Regulator Solutions.

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

1800CPB2 Pilot-Loaded Service Regulators

Series 100 Slam Shut Valve. Technical Bulletin

shutoff valves 900 Series psig Manual Shutoff Valves

Brooks Flow Controllers for Gas and Liquid Service Model FC 8744, Series FC 8800 and FC 8900

Operation Manual Piston Sensed Gas Pressure Regulators

Proportional Relief Valves

Solenoid valves, two-step on/off Type PMLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Series 2G Diaphragm Actuators

BACK PRESSURE / SUSTAINING

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Float Operated Level Controllers

General. Rugged, Reliable with Value-added Features. Pipe Sizes. Temperature Limits. Spring Ranges. Buried Service. Increased Outlet Pipe Sizes

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

BACK PRESSURE / SUSTAINING

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

Hydrogen Valves, Fittings and Tubing

Schroeder Check Test Point System

Models: C62/63/64-A/D

Pressure Dump Valve Service Kit for Series 2300 Units

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

Pressure Equalising Valves Model , for Differential Pressure Gauges

Suggested Installation & Operating Instructions for Sidewinder Pumps

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

Petro-Chemical & Analyzer Sampling Systems

INSTRUMENTATION VALVES

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Petro-Chemical & Analyzer Sampling Systems

SECTION BUTTERFLY VALVES

SG TF. Q = 963 Cv (P1 - P2)(P1 + P2) TECHNICAL INFORMATION. Flow Q (GPM)

JR Series. Gas Pressure Reducing Valve GAS PRESSURE REDUCING VALVE

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

INDUSTRIAL EXCESS ESS FLOW VALVES

Pressure Dump Valve Service Kit for Series 3000 Units

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

Instruction Manual Pressure Relief Valve and Rupture Disc Chlorine or Sulfur Dioxide, Series 869

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Section 3000 CONVEYOR CHAIN LUBRICATION SCHEMATIC...39 AIR OPERATED SPRAY DISPENSERS - CENTRAL ACRYLIC RESERVOIR Section 3000 Index

GILMONT ACCUCAL FLOWMETERS

Tank Blanketing Pressure Regulators RHPS Series

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Propor tional Re lief Valve s

VESSEL & REACTOR VALVES. VS Series SPRAY & RINSE VALVES PROCESS VALVES

Transcription:

Hydraulic & Offshore Supplies Hip Air Operated s YOUR GATEWAY TO GLOBAL SUPPLY HOSE ASSEMBLIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE

Air Operated s High Pressure Equipment Company offers five lines of air operators to accommodate remote operation of pressure valves up to 00,000 psi. Various models of diaphragm and piston operated valves are available in both normally open and normally closed models, and can be controlled by air regulator, electrical solenoid or low pressure manual valve. The Remetco line of air operated metering valves provides remote operation for fine metering applications. Index Page Mini-Hippo Piston Air Operators..............7.. Hipco Diaphragm Air Operators.................7.2 Remarco Diaphragm Air Operators.................7. Hippo Piston Air Operators.....7.. Remetco Piston Air Operated Fine Metering s..........7.4 R2 2/ 7.

Mini-Hippo Piston Air Operators for Remote Operation To 6,000 psi Mini-Hippo Air Operators are available for both normally open service (spring to open/air to close) and for normally closed service (air to open/spring to close). These piston air operators provide remote automatic on/off operation of valves and can be controlled by means of an air regulator, an electrical solenoid, or a manual low pressure valve in the user s air supply line. Air inlet is NPT. Air pressure requirement ranges from 0 to 0 psi. The Mini-Hippo air operators may be supplied with the valves and operating pressures shown in table. To order simply specify catalog number of valve and type operation required. EXAMPLES: Mini-Hippo 0- (normally closed) Mini-Hippo 0-2AF6 (normally open) Mini-Hippo 0-AF4 (normally open/ normally closed) " Diameter Piston Air Operators Open (Spring To Open / Air To Close) Maximum Operating Approximate AIr Pressure Pressure to Seat 0-**AF2 6,000 psi psi 0-**AF4 6,000 psi psi 0-**AF6 6,000 psi psi 0-** 6,000 psi psi 0-** 6,000 psi psi 0-**HF 6,000 psi psi Closed (Air To Open / Spring To Close) Maximum Operating Pressure ** Standard Patterns (reference Page.4) Minimum Approximate Approximate Adjusting Air Pressure Air Pressure Screw to Unseat to Fully Torque Open 0-**AF4 6,000 psi in. lb. 0 psi 0 psi 0-**AF6 6,000 psi in. lb. 0 psi 0 psi 0-** 6,000 psi in. lb. 0 psi 0 psi 0-** 6,000 psi in. lb. 0 psi 0 psi 0-**HF 6,000 psi in. lb. 0 psi 0 psi OPTIONS: Stems & Seats... Carbide (for cyclic service)............... 7-4 (for cyclic service) Bodies..... Hastelloy C, Hastelloy B............... Inconel 600, Inconel 62............... Incoloy 800, Incoloy 82............... Titanium Grade 2, Titanium 6AL4V............... temperatures from -42 F............... to,200 F (medium and high Open Closed 7.. R4 2/02

Hipco Diaphragm Air Operators for Remote Operation To Hipco Air Operators are available for both normally open service (spring to open/air to close) and for normally closed service (air to open/spring to close). These diaphragm air operators provide remote automatic on/off operation of valves and can be controlled by means of an air regulator, an electrical solenoid, or a manual low pressure valve in the user s air supply line. Air inlet is NPT. The Hipco air operators may be supplied with the valves and operating pressures shown in table. To order simply specify catalog number of valve and type operation required. EXAMPLES: Hipco 0- (normally closed) Hipco 0-2NFB (normally open) Hipco 0-AF4 (normally open/normally closed) OPTIONS: Stems & Seats... Carbide (for cyclic service)............... 7-4 (for cyclic service) Bodies..... Hastelloy C, Hastelloy B............... Inconel 600, Inconel 62............... Incoloy 800, Incoloy 82............... Titanium Grade 2,............. Titanium 6AL4V............... temperatures from -42 F to...............,200 F (medium and high Open 6 7 Diameter Diaphragm Air Operators Closed Air Operated s Open (Spring To Open / Air To Close) Maximum Operating Approximate AIr Pressure Pressure to Seat 0-**AF4 0,000 psi psi 0-**AF6 0,000 psi psi 0-**NFA 0,000 psi psi 0-**NFB 0,000 psi psi 0-**NFC 0,000 psi psi F-**NFA,000 psi 8 psi F-**NFB,000 psi 8 psi F-**NFC 0,000 psi 00 psi F-**NFD 0,000 psi 00 psi 20-**LF4 20,000 psi 20-**LF6,000 psi 8 psi 20-**LF 0,000 psi 00 psi 0-** 0,000 psi 0-** 0,000 psi 8 psi 0-**HF 0,000 psi 8 psi 40-**HF 0,000 psi 8 psi 60-** 70 psi 60-** 70 psi 60-**HF 70 psi Closed (Air To Open / Spring To Close) Maximum Operating Pressure ** Standard Patterns (reference Page.4) Minimum Approximate Approximate Adjusting Air Pressure Air Pressure Screw to Unseat to Fully Torque Open 0-**AF4 0,000 psi 20 in. lb. 0 psi 4 psi 0-**AF6 0,000 psi 20 in. lb. 0 psi 4 psi 0-**NFA 0,000 psi 20 in. lb. 0 psi 4 psi 0-**NFB 0,000 psi 20 in. lb. 0 psi 4 psi 0-**NFC 0,000 psi 20 in. lb. 0 psi 4 psi F-**NFA,000 psi 60 in. lb. 80 psi 00 psi F-**NFB,000 psi 60 in. lb. 80 psi 00 psi F-**NFC 0,000 psi 7 in. lb. psi 00 psi F-**NFD 0,000 psi 7 in. lb. psi 00 psi 20-**LF4 20,000 psi 40 in. lb. psi 0 psi 20-**LF6,000 psi 60 in. lb. 80 psi 00 psi 20-**LF 0,000 psi 7 in. lb. psi 00 psi 0-** 0,000 psi 40 in. lb. psi 7 psi 0-** 0,000 psi 60 in. lb. 80 psi 00 psi 0-**HF 0,000 psi 60 in. lb. 80 psi 00 psi 40-**HF 0,000 psi 60 in. lb. 80 psi 00 psi 60-** 0 in. lb. 8 psi 60-** 0 in. lb. 8 psi 60-**HF 0 in. lb. 8 psi High Pressure Equipment Company R4 2/02 P.O. Box 8248 222 Linden Ave. Erie, PA 60 U.S.A. Phone: (84) 88-2028 -800-28-7447 Fax: (84) 88-607 E-Mail: sales@highpressure.com 7.2

Remarco Diaphragm Operated s for Remote Operation To 00,000 psi Remarco air operated valves are available for both normally open service (spring to open/air to close) and for normally closed service (air to open/spring to close). These diaphragm operated valves provide remote operation up to 00,000 psi by means of an air input supply ranging from 2 to 0 psi to the air actuator. An electrical solenoid valve for the air supply is provided with all Remarco valves and is mounted directly to the valve. The standard solenoid is 20 volt, 60 cycle, watts with NPT air inlet. (Other voltages available at additional charge consult factory). The solenoid is normally closed and when energized allows air into the diaphragm casing to activate the valve. In the event of an electrical or air line failure, the valve will return to its normal position. The Remarco valve features removable stem seats. bodies are 6 stainless steel. stems are hardened 7-4PH stainless steel. Standard packing on the 0,000 psi and Remarco valves is Teflon O-ring with Buna-N, Viton, or Silicone, available at no additional cost. Open 7 Diameter Diaphragm Air Operators Closed Open (Spring To Open / Air To Close) D0R2LFR D20R2LFR D0R2R D0R2R D0R2HFR D0R2HFR D60R2R D60R2R D60R2HFR D00R2XF4R D00R2XF6R Maximum Operating Pressure 0,000 psi 20,000 psi 0,000 psi 0,000 psi 0,000 psi 0,000 psi 00,000 psi 00,000 psi 7 psi psi psi psi 0 psi 0 psi Closed (Air To Open / Spring To Close) SD0R2LFR SD20R2LFR SD0R2R SD0R2R SD0R2HFR SD0R2HFR SD60R2R SD60R2R SD60R2HFR SD00R2XF4R SD00R2XF6R 0,000 psi 20,000 psi 0,000 psi 0,000 psi 0,000 psi 0,000 psi 00,000 psi 00,000 psi 40 ft. lb. 0 ft. lb. 0 ft. lb. psi 70 psi psi 0 psi 0 psi 0 psi 8 psi 8 psi 0 psi 0 psi 7 psi 7 psi 7 psi 0 psi 00 psi 00 psi /6" /6" /6" /6" /6" /6" /6" /6" /6" /6" LF LF HF HF HF XF4 XF6 LF LF HF HF HF XF4 XF6 /6" /6" /6" /6" /6" /6" /6" /6" /6" /6" /6" /6".08" Tubing Approximate Connections Size Air Pressure Orifice to Seat O.D. I.D. Approximate Approximate Tubing Maximum Lock Nut Air Pressure Air Pressure Connections Size Operating Torque to Unseat to Fully Orifice Pressure Setting Open O.D. I.D. OPTIONS: /6" /6" /6" /6" /6" /6" /6" /6".08" /6" /6" /6" /6" /6" /6" Stems & Seats... Carbide (for cyclic service) Bodies..... Hastelloy C, Hastelloy B............... Inconel 600, Inconel 62............... Incoloy 800, Incoloy 82............... Titanium Grade 2, Titanium 6AL4V............... temperatures from -42 F............... to,200 F (medium and high 7. R4 2/02

Remetco Piston Operated Fine Metering s For Liquids or Gases Precise control with fast response is possible in fine metering applications to with Remetco s. Pinpoint accuracy and repeatability are assured by a unique stem travel control device working in concert with a Conoflow operator, which is actuated by an input air pressure on only psi. Body material is Type 6 stainless steel, with both stem and removable seat of 7-4PH. The stem tip is ground to a included taper, with orifice sizes as listed in the ordering table. Installation requires only connection to an air supply of 20 to 00 psi. This is connected both to the supply air connection and to the instrument air inlet. The latter is regulated between and psi to actuate the valve to the desired position. Regulation is effected by the user s instrument or by the optional instrument panel at lower left. Thus the valve is in its full open position with a psi air input and in the closed position with a psi air input. Failsafe operation. In standard configuration, the valve OPENS upon failure of the air supply. It may also be supplied to close upon air failure, to open upon an increase in air signal, or any combination of these specifications. Remote Positioner RVP. Optional instrument panel shown at bottom can be ordered as an accessory. It is a manually operated remote air signal valve positioner which permits positioning the stem at any desired point within the travel of the stem. The dial indicator is graduated into 00 increments; thus each dial increment moves the stem 0.02". Standard inlet and outlet connections to the Remetco are for /6" OD coned and threaded tubing. Adapters may be supplied for other tubing sizes upon request. Shutoff not recommended. While this valve is capable of on-off operation, it is designed as a fine metering instrument. To assure maximum stem life, a manual on-off valve should be used in the line upstream of the Remetco. To order, use assembly number in table and specify if operation is to be other than the standard closure upon air failure. Add RVP as suffix if remote air signal valve positioner is desired. Ordering Table Assembly Pressure Orifice Number Rating Size 0M-2HFR 0,000 psi 0M-2HFR 0,000 psi 60M-2HFR /6" OPTIONS: Stems & Seats... Carbide (for cyclic service) Bodies..... Hastelloy-C, Hastelloy B............... Inconel 600, Inconel 62............... Incoloy 800, Incoloy 82............... Titanium Grade 2, Titanium GAL4V............... temperatures from -42 F............... to,200 F (medium and high 7" 22" Remote Stem Positioner RVP above permits remote positioning of valve stem in increments of 0.02". To order, add suffix RVP to base order number. 7.4 R2 2/