SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z CALIBRATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PRECISION MEASURING CORP Groesbeck Hwy. Fraser, MI Robert Meyer Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z TROXLER ELECTRONICS LABORATORIES, INC. James Pratt Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Accredited Laboratory

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

CERTIFICATE OF ACCREDITATION ISO/IEC 17025:2005 ANSI/NCSL Z (R2002)

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

TG GUIDELINES CONCERNING CALIBRATION INTERVALS AND RECALIBRATION

METROLOGY LAB. I DEVICES BASED ON VERNIER SCALE

ENGINEERING TECHNICAL REPORT

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

CALIBRATION CERTIFICATE # 500

UKAS Accredited Electrical & Mechanical Calibration Services (Laboratory and On-site)

2014 Programme of Training Courses in Measurement & Calibration

I N N O V A T I O N C O N T I N U E S... International Patent Filed in 45 Leading Countries

MET-101 Introduction to Metrology

GUIDANCE FOR THE APPLICATION OF EQUIPMENT CALIBRATION AND TRACEABILITY OF MEASUREMENTS ON INSPECTION BODIES

MTS Restan. Automatic System for Residual Stress Measurement by Hole-Drilling

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Interlaboratory comparison in the pressure range from 0 to 2 MPa for accredited calibration laboratories

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

KENYA ACCREDITATION SERVICE

Precision pressure sensor Basic version Model CPT6020

BRINGING YOU THE SINCE 1980

Method of Test for Flat & Elongated Particles

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF PRESSURE METROLOGY

GMC-I Service GmbH Calibration Center

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SUMMARY... 2 II. SCOPE... 3 III. LIST OF ABBREVIATIONS AND UNITS... 3 IV.

Standard Operating Procedure Measuring & Testing Equipment

K V A L I F I K. Our accreditation number: NAH /2015. Valid to:

DFX II Series. Digital Force Gauge

WaterSense Specification for Spray Sprinkler Bodies. Version 1.0

How to evaluate pressure measurement specifications

AVIATION MAINTENANCE TECHNOLOGY REQUIRED TOOL LIST

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

Inspection and Acceptance of Asphalt Mix Design Laboratories

Accreditation for In-Service Inspection of Transportable Pressure Receptacles (TPRs)

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Pneumatic High-Speed Pressure Controller Model CPC3000

Experiment 13: Make-Up Lab for 1408/1420

Pressure is our Business

SEMETS3-17 Checking and calibrating mechanical inspection equipment

Technical Procedure for Instrument Calibration and Maintenance

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

Accreditation programme for calibration laboratories NAR KL Edition 1

B ADDENDUM # 1

BESTOOL GAGE CATALOG

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

TECHNICAL REPORT. TB Series Ball Valve. Report No: ILDTR Revision: 0 Total Pages: 19 Date: 14/02/12

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Gas mixtures. Individual solutions specifically for your application

CRITERIA FOR LABORATORY ACCREDITATION IN MASS METROLOGY

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

Technical Bulletin 57: Cut Testing for Wire Rope. Test Set-up. Pubilshed: October 2017

Specifications for Synchronized Sensor Pipe Condition Assessment (AS PROVIDED BY REDZONE ROBOTICS)

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

Title: INSTRUMENT AND EQUIPMENT DOCUMENTATION AND RECORDS

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF MASS METROLOGY

General Accreditation Guidance. User checks and maintenance of laboratory balances

EN ISO/IEC Technical Requirements

Procedia Engineering Procedia Engineering 2 (2010)

Density of Brass: Accuracy and Precision

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

SATEC COMPRESSION MACHINE Standard Operating Procedure

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

Dimensionair Air Gages Air Plugs. Features. Plug identification. Ordering Information Millimar. Air Gaging Instruments

Lab 7 Rotational Equilibrium - Torques

TORQUE WRENCHES CONTENTS MANUAL TORQUE MULTIPLIERS POWERED TORQUE MULTIPLIERS TORQUE MEASUREMENT INSTRUMENTS HYDRAULIC TOOL CALIBRATION FIXTURES

WHEATLEY Series 500 Swing Check Valve

Date of Shipment: Xxxxx 00, 20xx 3402c National Institute of Advanced Industrial Science and Technology National Metrology Institute of

P3000 Deadweight Tester Setup, Part 1: Limited Partial Correction Method

New ANSI Fall Protection Standards

Thread Gages Tolerances

Conductor Bushings Series 8174

How to Measure R7.1. Reference. I. Linear dimensions

Deadweight Tester / Pressure Balance High pressure up to 5,000 bar / 70,000 psi CPB5000-HP. Applications. Special features. Description. Rel.

INSPECTION FOCUS ON:

ARCHIMEDES PRINCIPLE AND THE COMPUTATION OF BUOYANT FORCES. Alexis Rodriguez-Carlson

NMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013

Inspection and Approval of Asphalt Mix Design Laboratories

threaded rod Keystock Diamond Case Linear Shafting strapping seals tools

Proficiency Testing for Surface Roughness Standard and Groove Depth Standard

CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration

Transcription:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 LEDFORD GAGE LAB, INC. 227 Industrial Dr. Mulvane, KS 67110 Blaine Johnson Phone: 316 777 9300 CALIBRATION Valid To: December 31, 2019 Certificate Number: 1560.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1 : I. Dimensional Parameter/Equipment Range CMC 2, 4 ( ) Comments Gage Blocks Up to 4 in (4.3 + 1.6L) in Mechanical comparator, twin head Micrometers 50 in Graduation 100 in Graduation Up to 6 in (62 + 0.9L) in (86 + 2.L) in Gage blocks 590 in Calipers Dial, Digital, Vernier 500 in Graduation Up to 12 in (620 + 1.4L) in (580 + 4L) in Gage blocks Gage Pins (0.01 to 1) in 27 in Supermicrometer (A2LA Cert. No. 1560.01) 01/02/2018 Page 1 of 4

Parameter/Equipment Range CMC 2, 4 ( ) Comments Optical Comparators 3 Linearity Up to 6 in (170 + 6L) in Glass master scales Indicators Dial, Digital Test Type 20 in Graduation 50 in Graduation 100 in Graduation 500 in Graduation Up to 1 in 24 in 48 in 69 in 290 in 580 in Plug Gages Plain, Cylindrical Threaded, 60 o Up to 10 in (26 + 1.6L) in Pitch Diameter Major Diameter 140 in 32 in Supermicrometer Ring Gages Plain Threaded, 60 o Up to 10 in (26 + 2L) in Pitch Diameter 100 in 300 in Set plug masters Labconcept Trimos Universal Measuring Machines 3 Length Up to 80 in (13 + 0.2L) in Optodyne laser system (A2LA Cert. No. 1560.01) 01/02/2018 Page 2 of 4

II. Mechanical Parameter/Equipment Range CMC 2, 5 ( ) Comments Indirect Verification of Rockwell Hardness Testers 3 HRC (< 35) HRC ( 35 and < 60) HRC ( 60) HRC 0.48 HRC 0.51 HRC 0.42 HRC ASTM E18 HRBW (< 60) HRBW ( 60 and < 80) HRBW ( 80) HRBW 0.55 HRBW 0.58 HRBW 0.92 HRBW HREW (< 84) HREW ( 84 and < 93) HREW ( 93) HREW 0.48 HREW 0.59 HREW 0.61 HREW Torque Wrenches Snap Type (5 to 50) in ozf (20 to 200) in ozf 0.078 % + 0.45 in ozf 0.11 % + 0.86 in.ozf CDI series 5000 torque transducers (5 to 50) in lbf 0.048 % + 0.54 in lbf (40 to 400) in lbf 0.11 % + 1.8 in lbf (100 to 1000) in lbf 0.21 % + 1.5 in lbf (25 to 250) ft lbf 0.097 % + 1.3 ft lbf (60 to 600) ft lbf (100 to 1000) ft lbf 0.14 % + 2 ft lbf 0.14 % + 3.1 ft lbf Dial and Beam (5 to 50) in ozf (20 to 200) in ozf (5 to 50) in lbf 0.024 % + 1.1 in ozf 0.065 % + 1.7 in ozf 0.052 % + 0.5 in lbf (40 to 400) in lbf (100 to 1000) in lbf 0.11 % + 1.8 in lbf 0.14 % + 3.1 ft lbf (25 to 250) ft lbf 0.046 % + 2 ft lbf (60 to 600) ft lbf 0.078 % + 2.3 ft lbf (100 to 1000) ft lbf 0.16 % + 2.6 ft lbf (A2LA Cert. No. 1560.01) 01/02/2018 Page 3 of 4

1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration and this laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these calibrations. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches 5 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted. (A2LA Cert. No. 1560.01) 01/02/2018 Page 4 of 4

Accredited Laboratory A2LA has accredited LEDFORD GAGE LAB, INC. Mulvane, KS for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of ANSI/NCSLI Z540-1-1994 and R205 Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 2 nd day of January 2018. President and CEO For the Accreditation Council Certificate Number 1560.01 Valid to December 31, 2019 For the calibrations to which this accreditation applies, please refer to the laboratory s Calibration Scope of Accreditation.