HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

Similar documents
Blood Pressure Monitor

Blood Pressure Monitor

Blood Pressure Monitor

Blood Pressure Monitor

Blood Pressure Monitor

Semi-Automatic Blood Pressure Monitor with Memory

INSTRUCTIONS. Manual Home Blood Pressure Monitor MODEL Stethoscope Chestpiece. Cuff. Bulb

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

STANDARD OPERATING PROCEDURE ARTSANA MERCURY SPHYGMOMANOMETER

Digital Blood Pressure Monitor. Model UA-705. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni 1WMPD B

Model UB-328. Wrist Digital Blood Pressure Monitor. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Auto Arm Blood Pressure Monitor

Aneroid Sphygmomanometer. Use, Care, & Maintenance

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

CONTENTS SPECIFICATIONS GENERAL INFORMATION RECOMMENDED USE OPERATING PRINCIPLE TIPS ON TAKING YOUR BLOOD PRESSURE 3-4 BATTERY INSTALLATION

Digital Blood Pressure Monitor. Model UA-787

Sports Wrist Digital Blood Pressure Monitor Item #

USE, CARE & MAINTENANCE DIAGNOSTIX TM 972 MERCURIAL BLOOD PRESSURE INSTRUMENT

TECHNICAL CHARACTERISTIC CT 071

Model AUTOMATIC UPPER ARM Blood Pressure Monitor

DIAGNOSTIX TM 922 MERCURIAL BLOOD PRESSURE INSTRUMENT. Use, Care, & Maintenance

INSTRUCTION MANUAL MANUAL INFLATION BLOOD PRESSURE MONITOR

UA-851THW/UA-851TMW/UA-851THX Wireless Automatic Blood Pressure Monitor Users Manual

Blood Pressure Monitor

MANUAL BLOOD PRESSURE MONITOR BPM 168B Contents Blood Pressure Monitor Intended Use What is blood pressure?

REF CH-302B IDENTIFICATION OF PARTS

BLOOD PRESSURE SENSOR BT17i USER S GUIDE

English Español Português Italiano Deutch Français INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR MODEL CH-656C. - Eng 1 -

User Manual. Hopkins IMPACT Digital Wrist BP RELATED ITEMS. Item #526014

Contents. Safety Notice. Wrist Type

MODEL CH-432B INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR. - Eng 1 - English Español Português Deutch. Italiano Français CH-432B

Fully Fuzzy Auto Digital Wrist Blood Pressure Monitor. tensio control. INSTRUCTION MANUAL Model GP-6220

Introduction. Table of Contents. Automatic Wrist Blood Pressure Monitor With Voice-Guided Operation. Model No.: BP5K

ADC. Sphygmomanometer Accessories. Directions for Use, Care, & Maintenance AMERICAN DIAGNOSTIC CORPORATION

Talking Wrist Style Blood Pressure Monitor Model INS-LAB-RevB08

Diagnostix TM Aneroids

REF CH-602B IDENTIFICATION OF PARTS

Digital Blood Pressure Monitor for the Upper Arm INSTRUCTION MANUAL

Talking Wrist TypeBlood Pressure Monitor. Talking Wrist Type Blood Pressure Monitor Model: BPW810. User Manual

Digital Blood Pressure Monitor Model UA-621 Instruction Manual

VER: A00. Model No:BA2010

Model UA-705. Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

Instruction Manual. Auto Inflate Blood Pressure Monitor

Oregon Scientific Wrist Blood Pressure Monitor (BPW211)

BLOOD PRESSURE SENSOR 0377i

PAPR Flow Tester. instructions. part no WARNING

3.1.3 Weight. Frequency. Weight is obtained at the baseline examination and annually. Equipment

INSTRUCTION MANUAL. Automatic Blood Pressure Monitor with Fit Cuff. =Fit Cuff=!"#$% IA1B. Model

Operating Instructions Instrucciones de funcionamiento

Oregon Scientific Wrist Blood Pressure Monitor (BPW120)

Ambient Weather GL150-TH Nautical Thermometer Hygrometer (ComfortMeter) User Manual

MEDICARE 60. Semi-automatic upper arm blood pressure monitor. Instruction manual

Circulation and Respiration: Vital Signs Student Version

Objectives: Assisting with Medication, Checking vital Signs

Installation Instructions

5 series Blood Pressure Monitor

Ambient Weather GL150-B Nautical Barometer User Manual

The RICH LIFE Project: Blood Pressure Training Certification Checklists

Model UA Digital Blood Pressure Monitor 使用手冊翻譯. Instruction Manual. Manuel d instructions. Manual de Instrucciones. Manuale di Istruzioni

ESTABLISHED OVER 150 YEARS FROM Accuracy starts in the name SPHYGMOMANOMETERS

Digital Wrist. Blood Pressure Monitor Advanced Wrist Monitor Instruction Manual

premium wrist blood pressure monitor

Lab #2: Blood pressure and peripheral circulation

Gauge Pressure, Absolute Pressure, and Pressure Measurement

Owner s Guide. ElevateSUP.com

Noninvasive Blood Pressure Measurement. D. J. McMahon rev cewood

General Warnings! A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead

WIKA INSTRUMENT CORPORATION

Omron Blood Pressure Monitor Need Manual Bp760 Automatic

D i g i ta l. B l ood Pressure M o n i t o r Advanced Blood Pre s s u re Monitor I n s t ruction Manual

Fully Automatic Blood Pressure Monitor

INSTALLATION AND OPERATING INSTRUCTIONS

DPC-30 DPC-100. Reference Manual

Instruction Manual. Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS ) Model HEM-650 ESPAÑOL ENGLISH

PR4 Installation, Operation & Maintenance Instructions (DOT Certification Included)

PHY100 s Lab: The Relationship Between Liquid Pressure and Depth as it applies to Blood Pressure. Course & Sec:

Blood Pressure Measurement made Easier and More Accurate!

MAGNETIC CYCLING TRAINER SF-B0419 USER MANUAL

Rev. B. Operating Instructions

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER COMPRESSOR For your personal safety please read, understand and follow the information provided in

256 Pneumatic Pressure Indicator

Vet-Temp Ear Thermometer Frequently Asked Questions

MyControl Bathing System Signature Series

Digital. Models 6021, 6022, 6023 User s Manual. Advanced Blood Pressure Monitors

PBT1100 POWER BANDING TOOL

Saturday, July 12, 14 GRAND DIVE

B.C.D. Buoyancy Compensator Device User Manual

Natural Gas to L.P. Gas Conversion Kit

6 & 8 Bubble Panel Installation Manual

ROUND ASSEMBLY. Positioning

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Content

CELEBRATING 150 YEARS Accuracy starts in the name SPHYGMOMANOMETERS

WHAT IS INCLUDED. Chamber. Silicone, patch, and auxiliary valve. White click on valve to help inflate bolsters. Thumb drive with set up instructions

BLOOD PRESSURE SIMULATOR LF01095U INSTRUCTION MANUAL

BIOPAK 240R MAINTENANCE TOOL KIT. TOOL KIT PART NUMBER: B Revision A

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

DuPont Personal Protection Instruction Manual for Universal Pressure Test Kit No

Lesson 12: Fluid statics, Continuity equation (Sections ) Chapter 9 Fluids

Transcription:

HOME BLOOD PRESSURE KIT INSTRUCTIONS TRILINGUAL INSTRUCTION GUIDE MODEL UA-100

IMPORTANT INFORMATION Please read this important information before using your monitor. Please remember that only a medical practitioner is qualified to interpret your blood pressure measurements. Use of this device should not replace regular medical examinations. Have your physician review the procedure for using this device. He or she will want to verify blood pressure measurements before prescribing or adjusting medications. Consult your physician if you have any doubt about your readings. Should a mechanical problem occur, contact A&D Medical. Clean the monitor and cuff with a dry, soft cloth or a cloth dampened with water and a mild detergent. Never use alcohol, benzene, thinner or other harsh chemicals to clean monitor or cuff. Precautions This Blood Pressure monitor is designed to be used at home or in a doctor s/nurse s office, by those who are eighteen (18) years and older, to monitor blood pressure (systolic and diastolic) and pulse rate. Caution: This product contains natural rubber latex which may cause allergic reactions.

TM TABLE OF CONTENTS BLOOD PRESSURE KIT COMPONENTS............... E-2 ASSEMBLY INSTRUCTIONS....................... E-3 Congratulations on purchasing a state-of-the-art LifeSource blood pressure monitor one of the most technologically advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. Physicians agree that daily self-monitoring of blood pressure is an important step individuals can take to maintain cardiovascular health and prevent the serious consequences associated with undetected and untreated hypertension. A&D Medical has been manufacturing high quality healthcare products for over 20 years. We are committed to providing you and your family with monitoring devices that provide the utmost in accuracy and convenience. TAKING YOUR BLOOD PRESSURE.................. E-3 TWO-PARTY METHOD........................... E-6 ABOUT BLOOD PRESSURE....................... E-7 BLOOD PRESSURE RECORD...................... E-9 MAINTENANCE INSTRUCTIONS................... E-10 CHECKING FOR ACCURACY..................... E-11 WARRANTY AND CONTACT INFORMATION........... E-12 FRENCH INSTRUCTIONS.......................... F-1 SPANISH INSTRUCTIONS......................... S-1 E-1

HOME BLOOD PRESSURE KIT COMPONENTS ASSEMBLY INSTRUCTIONS Vinyl Carrying Case Calibration Screwdriver Stethoscope Head Cuff D-Ring 1. Place cuff with arrow pointing towards you. 2. Make sure cuff end has been inserted through the D-Ring. 3. Insert single end of the Y-Tube into stethoscope head. 4. Insert each arm of the Y-Tube into each bottom end of the binaurals. 5. Insert air release valve into left bladder tube. 6. Insert manometer into right bladder tube. Y-Tube Cuff Right Bladder Tube Ear tips TAKING YOUR BLOOD PRESSURE Left Bladder Tube Manometer List of Components: Binaurals Inflation Bulb Air Release Valve Tips for Blood Pressure Monitoring: Relax for about 5 to 10 minutes before measurement. Remove constricting clothing and place cuff on bare arm. Unless your physician recommends otherwise, use left arm to measure pressure. Ear tips Binaurals Inflation Bulb Air Release Valve Manometer Left Bladder Tube Right Bladder Tube Y-Tube Cuff D-Ring Cuff Stethoscope Head Vinyl Carrying Case Calibration Screwdriver E-2 E-3

TAKING YOUR BLOOD PRESSURE TAKING YOUR BLOOD PRESSURE Now you are ready. Follow these simple steps: 1. Sit comfortably with your left arm resting on a flat surface so that the center of your upper arm is at the same height as your heart. 2. Lay left arm on the table with palm up. Place the cuff on upper arm with the tube facing downward and toward the inside of your arm. Fasten cuff securely with hook and loop fastener strap. 3. The cuff should be snug but not too tight. You should be able to insert two fingers between the cuff and your arm. 4. With your palm facing up, place the stethoscope head one-inch above the bend of the elbow on the inside of the arm. This is where the main artery is located. 5. Insert the ear tips of the stethoscope into your ears. Adjust by turning ear tips to fit comfortably in your ears. 6. Hold the manometer in your left hand and the inflation bulb in your right hand. 7. Close the air release valve on the bulb by turning the valve clockwise. 8. Inflate the cuff by repeatedly squeezing the bulb with your right hand. Listen to the pulse beat while inflating the cuff. 9. Watch the gauge. When you can no longer hear the pulse beat, raise the pressure an additional 30 mmhg. NOTE: Do not inflate the cuff above 280 mmhg. You may injure yourself or damage the equipment. If you are uncertain about the proper cuff inflation level, consult your physician. 10. After reaching your inflation level, slowly deflate the cuff by opening the air release valve. To open the air release valve, turn it counter-clockwise so that the pressure drops 2-4 mmhg per second. The needle on the manometer should drop an average of one to two marks every second. NOTE: Pressurizing the cuff shuts off all blood flow to the arm. Do not leave it fully inflated any longer than absolutely necessary. E-4 E-5

TAKING YOUR BLOOD PRESSURE ABOUT BLOOD PRESSURE 11. After opening the air release valve, listen carefully for a pulse beat. The moment you hear the first thumping sounds of your pulse beat, note the reading on the gauge. This is your systolic blood pressure measurement. 12. When you can no longer hear any sounds, read the gauge. This is your diastolic blood pressure measurement. 13. Remove cuff and make note of your blood pressure on the blood pressure record located on page E-9. NOTE: To be certain your technique was good and the readings were as accurate as possible, wait 10-15 minutes and repeat the procedure. Two-party method 1. If you plan on taking someone else s blood pressure, have the person whose blood pressure is to be taken to rest and relax at least 15 minutes beforehand. 2. Have the person extend his or her left arm toward you, palm up. Be sure the arm rests at the same level as the heart. 3. Position the cuff as indicated in the self-taking instructions. 4. Attach the manometer to the loop on the cuff, so that it is clearly visible to you. 5. Perform Steps 1-13 in Taking Your Blood Pressure. If possible, have your physician watch your technique to be sure it is correct. What Is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts; diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmhg). What Affects Blood Pressure? Blood pressure is affected by many factors: age, weight, time of day, activity level, climate, altitude and season. Certain activities can significantly alter one s blood pressure. Walking can raise systolic pressure by 12 mmhg and diastolic pressure by 5.5 mmhg. Sleeping can decrease systolic blood pressure by as much as 10 mmhg. Taking your blood pressure repeatedly without waiting an interval of 5 to 10 minutes between readings, or without raising your arm to allow blood to flow back to the heart, can also affect it. E-6 E-7

ABOUT BLOOD PRESSURE TM In addition to these factors, diet beverages containing caffeine or alcohol, certain medications, emotional stress and even tight-fitting clothes can make a difference in the readings. What Causes Variations In Blood Pressure? An individual s blood pressure varies greatly from day to day and season to season. For hypersensitive individuals, these variations are even more pronounced. Normally, blood pressure rises during work or play and falls to its lowest levels during sleep. Assessing High Blood Pressure The following standards for assessing high blood pressure (without regard to age) have been established by the National Institutes of Health JNCVI. Category Systolic (mmhg) Diastolic (mmhg) Optimal <120 <80 Normal <130 <85 High Normal 130-139 85 89 Hypertension Stage 1 140 159 90 99 Stage 2 160 179 100 109 Stage 3 180 110 E-8 E-9

MAINTENANCE INSTRUCTIONS CHECKING FOR ACCURACY Basic Care of Your Home Blood Pressure Kit With proper care, your Home Blood Pressure Kit will provide many years of reliable service. To insure a well functioning unit, follow these basic rules: Handle the pressure manometer with care. Do not drop or jar. The needle should indicate zero when cuff is fully deflated. Always deflate cuff before storing. Avoid hitting objects against surface of stethoscope. Store all items, including instruction booklet, in the convenient storage case provided. A&D Medical has checked your blood pressure unit to assure reliability and accuracy prior to shipment. However, as with any sensitive instrument subject to repeated use, we recommend your blood pressure unit be checked periodically for proper calibration to ensure accurate blood pressure readings. How to Check your Home Blood Pressure Kit for Accuracy 1. Detach manometer from bladder tube. Hold manometer in a vertical position. 2. If the needle on the dial rests within the zero indicator on the face plate, your unit is guaranteed to be accurate. 3. If the needle rests outside the zero indicator, it should be recalibrated. 4. To recalibrate, insert the small screwdriver into the hose connector end of the manometer. Turn the screw driver in either direction without going all the way around the dial to get the needle back to the zero indicator. 5. If the unit cannot be recalibrated using this method, please contact A&D Medical at 1-888-726-9966. Two-Year Calibration Warranty A&D Medical warrants, to the first retail purchaser of the Manometer (the Product), free accuracy adjustment for a period of two years if the Product becomes inaccurate under normal conditions of use. See enclosed warranty card for complete details. E-10 E-11

CONTACT INFORMATION Our products are designed and manufactured using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and treatment options. Our full product line includes: Heart Rate Monitors Digital Blood Pressure Monitors Aneroid Blood Pressure Kits Blood Pressure Cuffs Digital Thermometers Stethoscopes This LifeSource blood pressure product is covered by a twoyear warranty. See warranty card for details. VISIT OUR WEBSITE AT WWW.LIFESOURCEONLINE.COM FOR WARRANTY REGISTRATION. For more information regarding use, care or servicing of your blood pressure monitor, contact: A&D Medical A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 LifeSource Health Line (Toll-Free): 1-888-726-9966 www.lifesourceonline.com Canadian residents, please contact: Auto Control Medical 206A boul. Brunswick Pointe-Claire, Quebec H9R 5P9 Canada (Toll-Free): 1-800-463-5414 www.autocontrol.com LifeSource is a trademark of A&D Medical. 2002 A&D Medical. Specifications subject to change without notice. All rights reserved. UA-100 printed in Taiwan 02/02. E-12