EXPERIMENTAL ANALYSIS OF FIN TUBE AND BARE TUBE TYPE TUBE-IN-TUBE HEAT EXCHANGER

Similar documents
ANALYSIS OF HEAT TRANSFER THROUGH EXTERNAL FINS USING CFD TOOL

Experimental Analysis on Vortex Tube Refrigerator Using Different Conical Valve Angles

EXPERIMENTAL PERFORMANCE ANALYSIS OF VORTEX TUBE FOR VARIOUS PARAMETERS

DESIGN AND ANALYSIS OF DIFFERENT TYPES OF FIN CONFIGURATIONS USING ANSYS

Performance Improvement of Ranque-Hilsch Vortex Tube by Varying inside Surface Roughness of Hot Tube

OPTIMIZATION OF RECUPERATER FIN GEOMETRY FOR MICRO GAS TURBINE

ISSN: Page 410

A. M. Dalavi, Mahesh Jadhav, Yasin Shaikh, Avinash Patil (Department of Mechanical Engineering, Symbiosis Institute of Technology, India)

Performance Evaluation of Inverted Triangular Notch and Trapezoidal Plate Fins with Natural Convection

Micro Channel Recuperator for a Reverse Brayton Cycle Cryocooler

Effect of Hot End Obstruction and Nozzle on the Performance of Vortex Tube

A Numerical Study of the Performance of a Heat Exchanger for a Miniature Joule-Thomson Refrigerator

FABRICATION AND OPTIMIZATION OF PERFORMANCE OF VORTEX TUBE PARAMETERS

An Experimental Performance Study of Vortex Tube Refrigeration System

REVIEW ON FLUID-ELASTIC INSTABILITY IN FINNED TUBE ARRAYS

EXPERIMENTAL ANALYSIS OF FLOW OVER SYMMETRICAL AEROFOIL Mayank Pawar 1, Zankhan Sonara 2 1,2

STRESS ANALYSIS OF PRESSURE VESSEL WITH DIFFERENT END CONNECTIONS

Influence of Ambient Temperature on Performance of a Joule-Thomson Refrigerator

COMPUTATIONAL FLUID DYNAMIC ANALYSIS OF AIRFOIL NACA0015

A COMPARATIVE STUDY OF MIX FLOW PUMP IMPELLER CFD ANALYSIS AND EXPERIMENTAL DATA OF SUBMERSIBLE PUMP

[Laad* et al., 5.(6): June, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

ADVANCES in NATURAL and APPLIED SCIENCES

Modification and experimental research on vortex tube

An Efficient Vortex Tube With Max C.O.P

Address for Correspondence

Design and Structural Analysis of Cylindrical Shell

International Journal on Emerging Technologies 4(2): 21-26(2013) ISSN No. (Print) : ISSN No. (Online) :

Earlier Lecture. In the earlier lecture, we have seen Kapitza & Heylandt systems which are the modifications of the Claude System.

CFD analysis & Experimental Investigation of Shell & Tube Type Heat Exchanger with modified Slotted Baffles

External Tank- Drag Reduction Methods and Flow Analysis

AIR EJECTOR WITH A DIFFUSER THAT INCLUDES BOUNDARY LAYER SUCTION

Experimental Investigation on Stirling type Thermally Coupled Three Stage Pulse tube Cryocoolers with U type Configuration

Experimental Analysis of Inclined Narrow Plate-Fins Heat Sink under Natural Convection

Cooling Characteristics of GM-type Pulse Tube Refrigerator with Neon as Working Gas

Steam generator tube rupture analysis using dynamic simulation

Investigation of Stresses in Ring Stiffened Circular Cylinder

Figure 1 Schematic of opposing air bearing concept

WP2 Fire test for toxicity of fire effluents

Vibration-Free Joule-Thomson Cryocoolers for Distributed Microcooling

Visual Observation of Nucleate Boiling and Sliding Phenomena of Boiling Bubbles on a Horizontal Tube Heater

Design, Static Structural & Model Analysis of Water Ring Vacuum Pump Impeller

2.1 Introduction to pressure vessels

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

An Investigation of Liquid Injection in Refrigeration Screw Compressors

CFD ANALYSIS AND COMPARISON USING ANSYS AND STAR-CCM+ OF MODEL AEROFOIL SELIG 1223

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

Experimental Determination of Temperature and Pressure Profile of Oil Film of Elliptical Journal Bearing

Performance Analysis of a Helium Turboexpander for Cryogenic Applications with a Process Modeling Tool: Aspen HYSYS

Fabrication and Experimental Analysis of a Vortex Tube Refrigeration system

Computational Analysis of Cavity Effect over Aircraft Wing

Characteristics of Decompression Tank Internally Pressurized With Water Using OpenFOAM Syamsuri 1, a

DEVELOPMENT OF HIGH ALTITUDE TEST FACILITY FOR COLD JET SIMULATION

CFD Study of Solid Wind Tunnel Wall Effects on Wing Characteristics

CFD Simulation and Experimental Validation of a Diaphragm Pressure Wave Generator

PUSHOVER ANALYSIS OF STEEL STRUCTURE Santosh shet 1, Dr.Akshatha shetty 2 1

Performance Visualization of Bubble Sort in Worst Case Using R Programming in Personal Computer

DEVELOPMENT OF TWO OPPOSING NOZZLE VORTEX TUBE USING AIR AS WORKING FLUID

Volume 2, Issue 5, May- 2015, Impact Factor: Structural Analysis of Formula One Racing Car

Modeling and Investigation of Change in Working Parameters on the Performance of the Vortex Tube with CFD Analysis

CFD Flow Analysis of a Refrigerant inside Adiabatic Capillary Tube

Investigation on Divergent Exit Curvature Effect on Nozzle Pressure Ratio of Supersonic Convergent Divergent Nozzle

FEA ANALYSIS OF PRESSURE VESSEL WITHDIFFERENT TYPE OF END CONNECTIONS

Helium-Liquefaction by Cryocooler for High-Field Magnet Cooling

A COMPARATIVE STUDY OF PARAFFIN WAX

The Effect of Impeller Width on the Location of BEP in a Centrifugal Pump

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

Experimental Method to Analyse Limit Load in Pressure Vessel

CFD Analysis and Experimental Study on Impeller of Centrifugal Pump Alpeshkumar R Patel 1 Neeraj Dubey 2

Hermetic Compressor With Improved Motor Cooling

Australian Journal of Basic and Applied Sciences. Pressure Distribution of Fluid Flow through Triangular and Square Cylinders

Experimental Investigation on Transient Response of Two Stage Pressure Relief Valve

Experiment 8: Minor Losses

Design and Analysis of Reactor Dish Vessel

EXPERIMENTAL INVESTIGATION OF WAKE SURVEY OVER A CYLINDER WITH DIFFERENT SURFACE PROFILES

Two-way Fluid Structure Interaction (FSI) Analysis on the Suction Valve Dynamics of a Hermetic Reciprocating Compressor

HYDROGEN FAST FILLING TO A TYPE IV TANK DEVELOPED FOR MOTORCYCLES

CFD Analysis of Supersonic Nozzle with Varying Divergent Profile

CFD Analysis ofwind Turbine Airfoil at Various Angles of Attack

A Research on the Airflow Efficiency Analysis according to the Variation of the Geometry Tolerance of the Sirocco Fan Cut-off for Air Purifier

THE INFLUENCE OF INCONDENSIBLE GASES ON THE REFRIGERATION CAPACITY OF THE RELIQUEFACTION PLANT DURING ETHYLENE CARRIAGE BY SEA

Removing nitrogen. Nitrogen rejection applications can be divided into two categories

Development of Two Opposing Nozzle Vortex Tube Using Air as Working Fluid

Your Global Partner for Heat Exchanger and Boiler Tubes

CFD Analysis of Giromill Type Vertical Axis Wind Turbine

ZIN Technologies PHi Engineering Support. PHi-RPT CFD Analysis of Large Bubble Mixing. June 26, 2006

Serving. Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines Bulk Gas Plants

OPTIMIZATION OF SINGLE STAGE AXIAL FLOW COMPRESSOR FOR DIFFERENT ROTATIONAL SPEED USING CFD

Efficiency Improvement of Rotary Compressor by Improving the Discharge path through Simulation

Effect of Coiled Capillary Tube Pitch on Vapour Compression Refrigeration System Performance

Serving. Petrochemicals Power Semiconductor Waste Treatment Oil & Gas Transmission Lines Bulk Gas Plants

Influence of rounding corners on unsteady flow and heat transfer around a square cylinder

Optimization of Air compressor Motor speed for Reducing Power Consumption

Helium Mass Spectrometric Leak Detection In Large Size Process Plants

Aerodynamic Design, Fabrication and Testing of Wind Turbine Rotor Blades

Optimization of rotor profiles for energy efficiency by using chamber-based screw model

Brewery Vessels. #Britishmade #Britishbeer

Effect of Nozzle Twisted Lance on Jet Behavior and Spitting Rate in Top Blown Process

Flow and Mixing in the Liquid between Bubbles

Experimental Investigation and Modification of Ranque Hilsch Vortex Tube

The Usage of Propeller Tunnels For Higher Efficiency and Lower Vibration. M. Burak Şamşul

Transcription:

EXPERIMENTAL ANALYSIS OF FIN TUBE AND BARE TUBE TYPE TUBE-IN-TUBE HEAT EXCHANGER Kamalesh S. Kulkarni Assistant Professor, Department of Mechanical Engineering, VACOE, Ahmednagar, India Ravindra M. Ghodke Assistant Professor, Department of Mechanical Engineering, VACOE, Ahmednagar, India ABSTRACT Heat exchangers are the devices that facilitate the exchange of heat between the two fluids that are at different temperatures while keeping them from mixing with each other. In bare tube heat exchanger, the heat transfer rate is minimum so in order to increase the heat transfer rate different types of fins are used. The rate of heat transfer depends on the surface area of the fin. Rectangular and circular type fins are popular choices for transferring the heat from the primary surface of heat exchanger. In this paper, heat transfer rate and fin effectiveness for rectangular and circular fins were analysed for parallel flow and counter flow arrangement and comparison is done with bare tube (tube without fin) heat exchanger. Performance of rectangular fin is efficient than the circular fin. KEYWORDS Heat exchanger, types of fins, material used, LMTD, heat transfer rate, and fin effectiveness. INTRODUCTION Heat exchanger is a device which is used in most of the engineering applications. In conventional heat transfer equipments the heat is transfer between the two fluids which are separated by the surface. Typical examples of these equipments are refrigeration, vehicle engine, chemical processing plant, nuclear fuel storage tanks etc. In general, the heat transfer is takes place from inner tubes carrying the stream of hot fluid to stream of cold fluid by attaching the fins on the outer periphery of inner tube []. The rate of heat transfer depends on the surface area of the fin. The selection of any particular type of fin mainly depends on the geometry of the primary surface. Circular fins are mostly used for primary surface of cylindrical geometry for enhancing the rate of heat transfer. It is well known that the rate of heat transfer from the fin reduces as the length of the fin increases, therefore there is no utilisation of heat transfer surface to transfer the heat from the hot fluid to cold fluid. For this reason, the researcher has to work continuously for determining the optimum fin shape that will give the maximum heat transfer rate for specified fin volume or minimize the fin volume for a given heat transfer rate. N. Nagarani [] did the experimental analysis on annular circular and elliptical fins heat exchanger and concluded that rate of heat transfer is from elliptic fin is more than that of the circular fin. It has been shown that the fin efficiency is higher for elliptic fin than the circular fin. Sikindar Baba.Md, Nagakishore.S,Prof.M.Bhagvanth [3] has done the work on two- stage air compressor and concluded that the heat transfer rate of heat exchanger using fins is more than that of bare tube heat exchanger. Also M.R. Jafari Nasr and A.T. Zoghi [] had concluded that the by using Low finned tube rather plain tubes, not only can the performance of the heat exchanger be improved but also the number of shells required for a given can be reduced. Vekariyamukesh V., G. R. Selokar and Amitesh Paul [5]reported that the aluminium material used for the fin reduces the cost of raw material and also improves the product performance. However from the forgoing literature review shows that no combined work is attempted so far. So in this paper, aluminium material is used for the rectangular and circular fin. The objective of to find out heat transfer rate and fin efficiency of rectangular and circular fin and comparison is made with heat exchanger without fin. P a g e

EXPERIMENTAL ANALYSIS Novateur Publication s Figure shows the pictorial view of experimental setup used in the present study for the estimation of heat transfer on the rectangular fin attached in first tube and circular fin attached in second tube. The last one is bare tube heat exchanger. The rectangular and circular fin made of aluminium having thermal conductivity 3 W/mK. In this experimental setup the outer tube is made of stainless steel and inner tube is made of aluminium material. The primary as well as secondary fluid is water. There is one heater to heat up the water. The hot water is passing through the inner tube and the cold water is passing through the outer tube. There is flow arrangement provided in such a way that we can operate heat exchanger for parallel flow as well as counter flow. The fin dimensions for rectangular fin is 5mm*5mm*75mm and the diameter of circular fin is 8mmso that cross-sectional area is approximately same for both the fins. The readings are taken for different inlet temperatures of hot fluid like 75 C, 7 C and 65 C and inlet temperature of cold fluid is kept atmospheric and readings are tabulated for both fins and tube without fins also for parallel flow and counter flow. Figure. Pictorial view of experimental setup RESULT AND DISCUSSION Readings are taken on the experimental setup with different temperature conditions for parallel flow and counter flow and heat transfer rate and fin effectiveness is calculated for the rectangular and circular fin for the same flow arrangement. Table. Result table for counter flow Sr. No. Types of fin Temperatures T T t t LMTD ( C) Heat transfer rate(kw) Fin effectiveness. Rectangular. Circular 3. Without Fin 75 6 34 45 7.95.6866.376 7 58 34 43 6.5.978.857 65 55 34 4.47.794.666 75 59 34 44 7.89.44.5 7 57 34 4 5.4.9536.48 65 55 34 4.47.794.666 75 6 34 4 3.43.9536-7 6 34 4 7.99.794-65 57 34 4 3.99.465 - P a g e

Table. Result table for parallel flow Sr. No. Types of fin Temperatures T T t t LMTD ( C) Heat transfer rate(kw) Fin effectiveness. Rectangular. Circular 3. Without Fin 75 6 34 43 7.6.978.857 7 59 34 4 5.3.9536.335 65 58 34 4 3.9.465 75 64 34 4 3.5.9536.48 7 6 34 4 7..794.65 65 54 34 39.4..5 75 65 34 4 3.74.794-7 6 34 4 7.83.467-65 55 34 38 3.3.9768 - Heat Transfer Rate in kw 3.5.5.6866.44.978.9536.9536.794.794.794.465 T=75 t=34 T=7 t=34 T=65 t=34 Rectangular Circular Bare type Figure. Graph of Heat Transfer Rate for counter flow Heat Transfer Rate in kw.5.5.978.9536.9536.734.734.467.465..9768 T=75 t=34 T=7 t=34 T=65 t=34 Rectangular Circular Bare Type Figure 3. Graph of Heat Transfer Rate for Parallel Flow 3 P a g e

As shown in figure and figure 3 the heat transfer rate is taken on the Y-axis and the inlet temperature conditions of hot and cold fluid is taken on the X-axis. The figure is for the counter flow and figure 3 is for the parallel flow. The heat transfer rate is greater in the rectangular fin which is.6866 kw in counter flow and.978 kw in parallel flow. The heat transfer rate is increased by.4 %. The inlet temperature of hot fluid is changed as 75 C, 7 C, 65 C and heat transfer is plotted on chart. Fin Effectiveness.5.376.5.857.48.666.66 T=75, t=34 T=7, t=34 T=65, t=34 Rectangular Fin Circular Fin Figure 4. Graph of Fin Effectiveness in counter flow Fin Effectiveness.5.857.335.48.65.66 T=75, t=34 T=7, t=34 T=65, t=34 Rectangular Fin Circular Fin Figure 5. Graph of Fin Effectiveness in parallel flow Figure 4 and figure 5 shows the comparison of fin effectiveness in counter flow and parallel flow respectively. From the analysis the fin effectiveness is more for rectangular fin than the circular fin at different temperature conditions. CONCLUSION It is observed that the heat transfer rate is higher in counter flow than that of the parallel flow as can be seen from the figure and figure 3 that the driving force for heat transfer is constant in counter flow unlike parallel flow in which the driving force constantly decreases along with the length. It is observed that fin effectiveness of the rectangular fin is greater than the circular type of fin. The Log Mean Temperature Difference of tube without using fin is greater than the others but effect of reduced surface area dominates thereby nullifying the effect of increased log mean temperature difference resulting in lower heat transfer rate than the others. 4 P a g e

REFERENCES [] M.R. Jafari Nasr and A.T. Zoghi. (3). Full analysis of low finned tube heat exchangers. IJE TRANSACTIONS A: Basics Vol. 6, No. 3 (September 3) 7-3 [] N. Nagarani (). Experimental heat transferanalysis on annular circular and elliptical fins. International Journal of Engineering Science and TechnologyVol. (7),, 839-845. [3] Sikindar Baba.Md, Nagakishore.S, Prof.M.Bhagvanth (4). Thermal Analysis on a Finned Tube Heat Exchanger of a Two Stage Air Compressor. International journal for research in applied science and engineering technology (ijraset)vol. Issue V, May 4 ISSN: 3-9653. [4] Shiv Kumar Rathore and Ajeet Bergaley (). Comparative analysis of finned tube and bared tube type shell and tube heat exchanger. International Journal of Engineering and Innovative Technology (IJEIT) Volume, Issue, July [5] Vekariyamukesh V., G. R. Selokar and Amitesh Paul (). Optimization and Design of Heat Exchanger with Different Materials. IJMEMS, 5() January-June, pp. 37-4. [6] Y.G. Park and A. M. Jacobi (). Air-side performance characteristics of round- and flattube heat exchangers: a literature review, analysis and comparison. 5 P a g e